The 15 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 35 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.
Share this recordDownload vessel cardDownload QRMaury, US Coast Guard vessel record for CENTURY (ON 500019), retrieved 18 September 2026. mauryrecords.com/v/psix-45011.html
Documentation record
Tonnage as PSIX records it1289 - Regulatory (Subpart C or D), Gross Ton 1039 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 15
15 April 1991Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 917815
4 March 1991Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 995247
17 August 1990Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1230565
2 August 1990Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 933410
16 January 1990Re-Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 932071
18 October 1988COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 894041
23 February 1988Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1337217
18 November 1987Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1024954
30 March 1987Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1020221
5 February 1987Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1012130
16 December 1986Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1002206
16 September 1986COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1308202
13 August 1986Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1000671
21 May 1985Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1289071
24 April 1985Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 982897
INSTALL ELECTRICALLY DRIVEN FIRE/BILGE PUMP IN ADDITION TO STEAM DRIVEN PUMPS CURRENTLY ON BOARD.
Condition: Unknown
Due 17 February 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 2 August 1990Resolved
PROVE PROPER OPERATION OF THE #2 STEAM DRIVEN FIRE PUMP LOCATED ENGINEROOM STARBOARD.
Condition: Unknown
Due 7 September 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 18 November 1987Resolved
PROVIDE 3 MISSING PARACHUTE FLARES.
Condition: Unknown
Due 18 November 1987
Resolved 18 November 1987
Lifesaving
Issued 18 November 1987Resolved
COMPLETE SERVICING AND INSTALLATION OF INFLATABLE LIFERAFT. VESSEL MAY NOTBE OPERATED AS A MANNED BARGE UNTIL RAFT IS RETURNED.
Condition: Unknown
Due 18 November 1987
Resolved 18 November 1987
Navigation
Issued 18 November 1987Resolved
PROVIDE PROPER LIGHT BULBS IN ALL NAVIGATION LIGHT FIXTURES. ONLY 2 HAVE PROPER BULBS.
Condition: Unknown
Due 18 November 1987
Resolved 18 November 1987
Electrical
Issued 18 November 1987Resolved
PROVIDE MISSING GLOBES AND CAGES FOR INTERIOR LIGHTS AS FOLLOWS: (1) #4 MOLD - 4 GLOBES/2 CAGES. (2) PUMPROOM - 2 GLOBES (3) UPPER LEVEL BOILER SPACE - 2 GLOBES
Condition: Unknown
Due 18 November 1987
Resolved 18 November 1987
Fire Fighting
Issued 16 December 1986Resolved
REPAIR OR REPLACE THE FIRE PUMP LOCATED IN THE PUMPROOM, PUMP SHALL BE TESTED TO SATISFACTION OF ATTENDING INSPECTOR.
Condition: Unknown
Due 16 December 1986
Resolved 16 December 1986
Fire Fighting
Issued 16 December 1986Resolved
SUBMIT U.S. COAST GUARD FORM 2692 FOR FIRE PUMP FAILURE.
Condition: Unknown
Due 16 December 1986
Resolved 16 December 1986
Lifesaving
Issued 16 September 1986Resolved
PROVIDE 10 SURVIVAL SUITS APPROVED BY U.S. COAST GUARD UNDER 46 CFR 160.071.
Condition: Unknown
Due 16 September 1986
Resolved 16 September 1986
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.