← All vessels
SILVER GLORY
Freight Ship · Ro-Ro Cargo Ship class · Built 1990s · USCG Southeast District (CGD-SE) · Other hulls named SILVER GLORY
SILVER GLORY is a 1994 freight ship. The Coast Guard has recorded 34 inspections since 1996, most recently in March 2025, along with 13 deficiencies and 2 operational controls.
Records from 1996 to 2025. Most recent: inspection, 26 March 2025.
- Built
- 1994
- Last inspected
- 26 March 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 13 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9070474 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
H90A
450115
Flag
PANAMA
—
Maury page id
psix-450115
Inspections, by type
…with no type recorded12
Years with a record
18 calendar years (1996–2025)
The 34 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it13445 - Regulatory (Subpart C or D), Net Ton
13445 - Convention (Subpart B), Net Ton
44818 - Convention (Subpart B), Gross Ton
13308 - Dead Weight, Ton
44818 - Regulatory (Subpart C or D), Gross Ton
13445 - Convention (Subpart B), Net Ton
44818 - Convention (Subpart B), Gross Ton
13308 - Dead Weight, Ton
44818 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 34
26 March 2025
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8094815
26 March 2025
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8099888
17 March 2025
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8094792
11 August 2024
PSC A
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7977208
25 February 2021
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7146403
13 November 2020
PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7092372
15 July 2020
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7007324
2 June 2020
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6966503
1 June 2020
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6965538
1 June 2020
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6966496
30 October 2019
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6843675
15 December 2018
ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6594427
1 November 2017
ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6298822
21 September 2016
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6003666
19 March 2016
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5835324
30 July 2012
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4395760
2 November 2010
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3883512
1 November 2010
PII Safety Exam · ISPS I Exam · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3879114
1 November 2010
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3883088
31 October 2010
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3885179
29 October 2010
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3881042
18 December 2007
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3117869
7 September 2006
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2771729
12 May 2005
MARPOL Annex I Examination · Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2354001
13 May 2004
MARPOL Annex I Examination · Annual Inspection · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2066488
14 November 2003
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1945258
22 April 2003
Ballast Water Examination · Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1776041
17 November 2002
Ballast Water Examination · Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1704808
9 April 2002
Security Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1602993
6 March 2002
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1722702
6 March 2002
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1722711
27 February 2002
Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1488965
9 December 1999
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 435471
29 November 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 397907
Deficiency record · 13
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 March 2025
Resolved
Any required fixed fire detection [...] shall be capable of immediate operation at all times. Fire detector over ship's service generators was found inoperable.
74 SOLAS (97)
II-2/1.1
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 June 2020
Resolved
The location of the controls of any valve serving sea inlet shall be so sited as to allow adequate time for operation in case of influx of water to the space. Both the port and starboard sea chest valves are inoperable and cannot be secured to prevent the influx of water to the engine room. 74 Solas (04) CH II-1 Reg. 48.3 60 ac
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 1 June 2020
Resolved
Whenever there is a hazardous conditions either onboard a vessel or caused by a vessel or its operation, the master must notify the nearest US Coast Guard office. Both Port and starboard sea chest valves do not close or actuate, resulting in potential catastrophic flooding of engineering. 33 CFR 160.216(a) 60 a/c
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 1 June 2020
Resolved
The Company and the ship shall comply with the requirements of the International Safety Management Code. In meeting these requirements, the company should ensure that: any non-conformity is reported; appropriate corrective action is taken; and records of these activities are maintained. PSCO observed multiple SMS policy violations following the discovery of 04 inoperable sea chest valves on 18MAY2020:
1)As per the vessel's SMS, the Master is required to report to port authorities, vessel management and local agents any damage or defect that affects a vessel's seaworthiness. No notifications to the U.S. Coast Guard, vessel company or local agent were made regarding inoperable valves prior to arrival.
2) Per the vessel's SMS, the Chief Engineer is responsible for the efficient and reliable operation of all machinery equipment and installations, including notification to the company of any abnormalities. Chief Engineer did not document any issues related to the sea chest or its associated valves and made no notifications to the vessel's Master or company. Further, no corrective action was taken or documented. Based on objective evidence, PSCO recommends full ISM external audit. 74 SOLAS (14) IX/3.1 ISM Code 10.2
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 June 2020
Resolved
The condition of the ship and its equipment shall be maintained to confrom with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Both port and stbd sea chest valves have been in-operable since last dry dock (Sep 2019) and last class survey. 74Solas(14)CH I Reg. 11(a)
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 1 June 2020
Resolved
A self-contained emergency source of electrical power shall be provided. Emergency generator did not operate properly to provide emergency source of electrical power.
74Solas(04) II-1/43.1.1
Deck/Cargo › Holds/Tanks › Coaming
Issued 1 November 2010
Resolved
1240 AFT CARGO RAMP DOOR HYDRULIC LINE FAILED AND LEAKED APPROXIMATELY 25 GAL. RAMP UN-ABLE TO CLOSE DUE TO FAILURE. ILLC Annex I Reg 21. 17c
Stability › Weathertight Integrity › General
Issued 1 November 2010
Resolved
1270 ALL ACCESS OPENINGS IN BULKHEADS AT ENDS OF ENCLOSED SUPERSTRUCTURE SHALL BE FITTED WITH STEEL WEATHER TIGHT DOOR. MULTIPLE DOOR FRAMES ARE WASTED AND OR HOLED, AND UNABLE TO MAKE WEATHER TIGHT. ILLC Annex I Reg 12(1) 70a
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 7 September 2006
Resolved
Bunkering transfer procedures are incomplete, and do not meet the requirements of 33 CFR 155.750.
Documentation › Manuals/Policy Documentation › Instructions for On-board Maintenance (lifesaving)
Issued 7 September 2006
Resolved
Battery charger in port lifeboat does not match what type is in the maintenance and operation instruction manual onboard the lifeboat. Discrepancy needs to be corrected to the satisfaction of class after sailing foreign.
Documentation › Certificates/Documents › IOPP Certificate
Issued 7 September 2006
Resolved
IOPP certificate form A has incorrect information. The certificate has a keel laid date of April 27, 1997 and the vessel delivery date was November 28, 1994. A survey was completed by class on October 12, 2005. Correct prior to next U.S. port after sailing foreign.
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 14 November 2003
Resolved
Repair the refractory inside the incinerator where there is a hole, to the satisfaction of class. The hole extends the width of the refractory to the metal exterior SOLAS 74 amd I/II. LEGACY COMPONENT DESC: INCINERATOR
Personnel › Certificates/Documents/Licenses › License, Master
Issued 17 November 2002
Resolved
Master License expired 11 Nov 2002
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.