13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 October 2025
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. MI found fuel leak on the port MDE. Fix leak and notify local OCMI. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 October 2025
Resolution: Fuel leak on the port MDE has been corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 October 2025
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines at the tank connection. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. The vessel's port fuel shutoff valve broke during test. Vessel has repaired fuel shutoff but still needs to be tested which is scheduled for 16OCT25. 46 CFR 182.455(b)(4)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 October 2025
Resolution: Pull cable has been corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 October 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. MI found electrical outlet missing the face cover in the engine room. Replace face cover and notify local OCMI. 46 CFR 183.200(c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2025
Resolved 16 October 2025
Resolution: Electrical outlet's face cover has been replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 October 2025
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. MI found through hull valve in the laz uncapped. Cap valve and notify local OCMI. 46 CFR 182.200
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2025
Resolved 16 October 2025
Resolution: Uncapped valve now has a cap.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 17 July 2024
Resolved
Generator belt guard was found to be not fully secured, permanently bolt guard to the generator.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 August 2024
Resolution: Guard was properly bolted to the generator.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 July 2024
Resolved
Label life jacket storage to indicate adult or child.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 August 2024
Resolution: Life jacket stowage was properly labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 July 2024
Resolved
Line on ring buoy was found deteriorated, replace line.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 August 2024
Resolution: Line was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 20 October 2023
Resolved
All vessels except non-self-propelled vessels shall be provided with suitable steering apparatus. The steering rod connecting the Port and Starboard rudder sheared. Conduct approved repairs and notify the OCMI to witness operational test. 46 CFR 183.30-1 (OLD T)
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2023
Resolved 25 October 2023
Resolution: Attended vessel and witness steering test, all sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 August 2023
Resolved
Steering systems must be properly mounted/secured and ready to be tested by USCG Marine Inspectors at each initial/subsequent inspection for certification. Primary steering ram was not properly mounted causing potential steering casualty while system is engaged. Must make necessary repair to the satisfaction of the USCG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2023
Resolution: Witnessed satisfactory test.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 August 2023
Resolved
Light on ring life buoy was inoperable. Vessel is restricted to day time operations until it is repaired.
Action required: 705 - Other - as specified
Resolved 22 August 2023
Resolution: Witnessed satisfactory test.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 11 August 2023
Resolved
Vessels Communications Act Safety Radio Certificate expired on June 11, 2023.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 August 2023
Resolution: Vessel acquired a new (valid) certificate.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 August 2023
Resolved
All griddles, broilers, and deep fat fryers must be fitted with a grease extraction hood in compliance with 181.425. A grease extraction hood must meet UL 710 or other standard specified by the Commandant. A grease
extraction hood must be equipped with a dry or wet chemical fire extinguishing system meeting NFPA 17 or other standard specified by the Commandant, and must be listed by an independent laboratory recognized by the Commandant. Install grease extraction hood equipped with a dry or wet chemical fire extinguishing system to the satisfaction of an attending marine inspector. In accordance with CID policy letter #20, and PFM 1-99
alternative arrangements may be allowed if the vessel maintains and logs a (At a minimum) quarterly cleaning and inspection schedule. The vessel did not have a cleaning and inspection program.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 September 2023
Resolution: Plan in place.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 11 August 2023
Resolved
A device must be provided to automatically shut down power ventilation serving the protected space and engines that draw intake air from the protected space prior to the release of the extinguishing agent into the space. Both port and starboard vent fans do not shut down upon release of CO2.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 August 2023
Resolution: The fans were wired into the engine shutdowns. A satisfactory test was witnessed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 August 2023
Resolved
Vital system piping shall be composed of ferrous materials. The suction and discharge pipes connected to the installed bilge pump are PVC.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 August 2023
Resolution: Metallic piping was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 August 2023
Resolved
A visual indicator must be provided at the operating station to indicate when ANY automatic bilge pump is operating. The vessel has numerous electric submersible bilge pumps installed and the indicator panel in wheel house was found inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 September 2023
Resolution: Bilge indicators found operable.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 August 2023
Resolved
Electrical plans were reviewed and approved for the vessel in 2021 by Sector San Diego. Numerous modifications have been made to the engine room panel and wheel house panel without USCC approval or plan review. Submit new plans for review.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 September 2023
Resolution: plans submitted and reviewed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 August 2023
Resolved
Electrical outlet with USB in the charger in the wheel house was found burnt and poses a fire hazard. Replace outlet.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 August 2023
Resolution: Replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 August 2023
Resolved
Provide double hose clamps for generator sea strainer connections.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 August 2023
Resolution: Double hose clamps were installed.
07 - Fire Safety › N/A - No Subsystem › Crew alarm
Issued 11 August 2023
Resolved
Prove proper operation of watch alarm system. Roving watch alarm was inoperable. The Operator/Captain did not know how to log in to even test it.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2023
Resolution: Witnessed satisfactory test.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 August 2023
Resolved
Remove dead ended cable starboard side engine room forward, labeled RSW.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 August 2023
Resolution: Cable was removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 August 2023
Resolved
Replace starboard main engine raw water hose, hose was found collapsed and kinked. Provide new hose with double hose clamps.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 August 2023
Resolution: Replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 August 2023
Resolved
Remove dead ended cable, between main engines, forward, port side.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 August 2023
Resolution: Cable was removed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 11 August 2023
Resolved
Provide all deck hatches with chain / retaining device.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 August 2023
Resolution: Hatch chains were reconnected.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 11 August 2023
Resolved
Provide permanent means to secure all vent openings for engine compartment. 03 on aft end of house, 04 on raised engine room hatch access.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 August 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 August 2023
Resolved
Remove dead ended cable in area forward of wheel house console. Cable is located by pump, port side, near bilge.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 August 2023
Resolution: Cable removed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 August 2023
Resolved
Provide junction box for electrical connections found in wheel house counsel. Cable splice with wire nuts were found on the port / upper side.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 August 2023
Resolution: Installed.= junction box.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 11 August 2023
Resolved
Prove proper operation of public address system.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 August 2023
Resolution: Witnessed satisfactory test.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 August 2023
Resolved
Provide electrical outlet with cover, located forward end of bunk space / port side.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 August 2023
Resolution: New cover installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 August 2023
Resolved
Properly mount automatic heat detector for CO2 system.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 August 2023
Resolution: Properly secured in place.
02 - Structural Conditions › N/A - No Subsystem › Permanent means of access
Issued 11 August 2023
Resolved
Provide forward escape hatch with proper labeling, 2" letters "EMERGENCY EXIT, KEEP CLEAR"
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 August 2023
Resolution: New sign installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 August 2023
Resolved
Electrical power for the anchor windlass was found with taped splice in the cable in the forward void. Provide electrical connections with a proper junction box.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 August 2023
Resolution: 02 junction boxes installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 August 2023
Resolved
Complete all items from CG-835 issued on 8/1/23. Open defs are #6, #9, and #16.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 August 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 July 2023
Resolved
Starboard marine gear experiencing intermittent clutch failures. Identify source of failure, repair and provide operational test with CG oversight.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2023
Resolution: Conducted COI renewal and repaired engine issues. See activity 7764359
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 July 2023
Resolved
Portable and installed fire equipment was found with expired fire servicing records. Provide all portable and installed fire extinguishing equipment with annual servicing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2023
Resolution: Equipment was serviced.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 29 July 2023
Resolved
Generator belts and pulleys were found open and without a guard. Provide engine with proper guard to prevent personnel injury.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2023
Resolution: Guard was installed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 29 July 2023
Resolved
Generator salt water cooling piping was found with PVC fittings and non-approved flexible hose. Provide generator vital system piping with approved fittings, hoses, and clamping.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2023
Resolution: PVC removed and metal piping installed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 29 July 2023
Resolved
Starboard reduction gear foundation mounting bolts were found to missing and never re-installed after recent gear work. Provide reduction gear with adequate fastening to engine bed frames.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2023
Resolution: Foundation bolts were installed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 29 July 2023
Resolved
Starboard reduction gear lube oil cooling hose (type SAE J-1942) was found with a flared copper fitting. Provide vital system with proper SAE J-1475 fitting.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2023
Resolution: Correct fitting was installed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 29 July 2023
Resolved
Generator fuel lines were found with replacement lines installed and without proper support brackets. Install fuel line support clamps in accordance with engine manufacture.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2023
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 29 July 2023
Resolved
Starboard reduction gear cooler was found unmounted and unsecured. Properly mount red gear cooler.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2023
Resolution: Cooler was mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 29 July 2023
Resolved
Generator sea strainer was found unmounted and unsecured. Properly mount sea strainer.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2023
Resolution: Strainer was mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 July 2023
Resolved
Numerous electrical panels were found with missing breakers and unidentified circuits. Provide labeling for all circuits and properly enclose electrical panels.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 July 2023
Resolved
Battery disconnect switch between main engines was found unmounted. Properly secure/mount switch.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2023
Resolution: Switch was mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 July 2023
Resolved
Bilge pump connection terminal between main engines was found unmounted. Properly secure/mount terminal.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2023
Resolution: Connection was mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 29 July 2023
Resolved
Port main engine salt water cooling hose was found chaffing against engine mount. Prove hose is still serviceable and provide chafe protection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2023
Resolution: Chafe protection was provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 July 2023
Resolved
Machinery start batteries were found unsecured and without battery box covers. Properly mount and secure covers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2023
Resolution: All batteries were mounted and covered.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 July 2023
Resolved
Multiple dead ended cables were found in the engine room. Remove dead ended cables or terminate inside a junction box.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2023
Resolution: Cables were removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 July 2023
Resolved
Saltwater pump / motor electrical junction box was found unsecured and not watertight. Properly secure electrical junction box.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2023
Resolution: Junction box was sealed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 29 July 2023
Resolved
Multiple modular smoke detectors were found uninstalled and/or disabled. Re-install all smoke detectors and prove proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 August 2023
Resolution: Witnessed satisfactory test of smoke detectors. All detectors were integrated as per the interim rule.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 July 2022
Resolved
Vessel owner or operator must comply with lifesaving arrangements located in part 180 of this chapter. A rescue boat or suitable rescue arrangement must be provided to the satisfaction of the [name withheld] to the OCMI that the ladder used during MOB could successfully allow a crew member to recover an unconscious passenger or replace the lifesaving device.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 September 2022
Resolution: Witnessed satisfactory test with rescue ladder utilizing an OSCAR dummy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 July 2022
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens of 30x30 corrosion resistant mesh or flame arresters.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2022
Resolved 6 September 2022
Resolution: Vessel acquired 30x30 mesh and installed.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 27 July 2022
Resolved
Provide current FCC station license for marine radio
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2022
Resolved 9 September 2022
Resolution: Received copy of new document.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 July 2022
Resolved
Plans for the installation and use of monitoring devices to ensure the wakefulness of the watchmen were due to the OCMI 90 days after publication of the interim rule published December 27, 2021. Plans must be submitted to the OCMI.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 August 2022
Resolution: Received plans via email.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 30 April 2021
Resolved
Prove proper operation of high water alarm visual indicator for steering and machinery space. Both visual indicators illuminate at station #5 (steering space) on the bridge, machinery space should have a visual indicator at station #4.
Action required: 705 - Other - as specified
Due 18 May 2021
Resolved 18 May 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 April 2021
Resolved
Mount fixed bilge pump to pedestal to prevent shifting. 46CFR183.320
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2021
Resolved 18 May 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 April 2021
Resolved
Remove PVC and non-rigid hose from bilge system. Install rigid non-metallic hoses and metallic connections (check valves/stop valves/unions) along with double hose clamps throughout entire bilge system. 46CFR182.40-1 and 46CFR182.40-5 (Old-T)
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2021
Resolved 18 May 2021
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 30 April 2021
Resolved
Install valve handle on port fuel tank, forward connection shutoff valve.
Action required: 705 - Other - as specified
Due 30 May 2021
Resolved 18 May 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 April 2021
Resolved
Install battery box covers on port side machinery space.
Action required: 705 - Other - as specified
Resolved 18 May 2021
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 30 April 2021
Resolved
Must show enrollment into Drug and Alcohol Prevention Program for all crew members.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2021
Resolution: All documentation provided to MI: [name withheld]
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 30 April 2021
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2021
Resolved 25 May 2021
Resolution: Documenation provided to MI: [name withheld]
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 April 2021
Resolved
Provide 07 USCG approved life jackets. Passenger count reduced by 07 until deficiency is rectified.
Action required: 705 - Other - as specified
Resolved 18 May 2021
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 April 2021
Resolved
Install corrosion resistant clip for Ring Life Buoy water light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2021
Resolved 18 May 2021
09 - Working and Living Conditions › 092 - Working Conditions › Danger areas
Issued 30 April 2021
Resolved
Secure oxygen cylinder located next to life raft.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2021
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 30 April 2021
Resolved
Must get underway with CG Marine Inspectors present and conduct drills.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2021
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 February 2021
Resolved
Each hatch used as an emergency means of escape must be capable of being opened by one person, from either side, in both light and dark conditions. The method of opening must be obvious, rapid and of adequate strength. Emergency exit from below deck found sealed shut by marine sealant. Hatch opening internal T-handle found extremely difficult to turn by one person. Remove all sealant, conduct maintenance, hose test hatch seal and mark T-handle opening direction of turn.
Condition: Improper Installation
Action required: 30 - Ship detained
Due 25 February 2021
Resolved 10 March 2021
Resolution: Verified by [name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 February 2021
Resolved
Repairs or alterations to the vessel equipment (electrical wiring) must not be made without the approval of the cognizant OCMI, except during an emergency. During dry dock examination, at least 6 alterations to electrical system were found in progress. Owner stated new wiring and outlets were being installed. Vessel has outstanding CG-835V due 14JAN2020 for submission of electrical one-line drawing to OCMI. Provide complete electrical one-line diagram of all A/C electrical circuts (new & existing) for review/approval.
Condition: Invalid
Action required: 30 - Ship detained
Due 25 February 2021
Resolved 18 May 2021
Resolution: Electrical Plan submitted and successfully reviewed and approved by OCMI: [name withheld]
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 February 2021
Resolved
Properly secure fixed gas fire extinguishing bottle. Bottle was found unsupported.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 February 2021
Resolved 5 March 2021
Resolution: Verified by [name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 25 February 2021
Resolved
Provide generator salt water piping with ferrous materials. Generator piping was found with PVC piping installed.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 25 February 2021
Resolved 10 March 2021
Resolution: Verified by [name withheld]
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 25 February 2021
Resolved
Prove proper operation of the starboard main engine's fuel system. Engine was found with fuel soaked absorbent cloth wrapped around the piping and residual fuel settled on the fuel pump assembly.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 25 February 2021
Resolved 18 May 2021
Resolution: Vessel successfully underway for drills and sea trial: [name withheld]
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 June 2020
Resolved
Prove operations of main engines, generator, bilge alarms, and emergency lighting.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 2 June 2020
Resolved 19 June 2020
Resolution: Tests conducted in presence of attending MI: Mosley
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 June 2020
Resolved
Provide covers to distribution panels in engine space.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 2 June 2020
Resolved 18 June 2020
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 2 June 2020
Resolved
Must have all radios inspected by FCC license inspector and and receive current FCC Radio Safety Certificate.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 June 2020
Resolved 18 June 2020
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 2 June 2020
Resolved
Prove proper operations of radar.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 June 2020
Resolved 18 June 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 June 2020
Resolved
Prove proper operations of all around and mast navigation lights.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 June 2020
Resolved 16 June 2020
Resolution: Attending MI witnessed operation of nav light, [name withheld]
11 - Life Saving Appliances › N/A - No Subsystem › Emergency equipment for 2-way comm.
Issued 2 June 2020
Resolved
Properly mount EPIRB.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 2 June 2020
Resolved 16 June 2020
Resolution: Attending MI witnessed rectification of def, [name withheld]
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 June 2020
Resolved
Cap all dead end wiring aboard vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2020
Resolved 19 June 2020
Resolution: Verified by attending MI: Mosley
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 June 2020
Resolved
Replace bad retro reflective tape and lights on life jackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2020
Resolved 19 June 2020
Resolution: Verified by attending MI: Mosley
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 June 2020
Resolved
Provide machinery guards over shafts and generator serpentine belt.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2020
Resolved 19 June 2020
Resolution: Machinery guards have been provided, but need to move back an inch, Mosley
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 June 2020
Resolved
Replace piping in thru-hull to transom
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2020
Resolved 19 June 2020
Resolution: Verified by attending MI: Mosley
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 June 2020
Resolved
Reinstall handrails at entrances on port and starboard side.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2020
Resolved 16 June 2020
Resolution: Def corrected and witnessed by attending [name withheld]
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 June 2020
Resolved
Properly install lagging on port main exhaust.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2020
Resolved 19 June 2020
Resolution: Verified by attending MI: Mosley
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 June 2020
Resolved
Provide lagging specifications on starboard exhaust.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2020
Resolved 19 June 2020
Resolution: Verified by attending MI: Mosley
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 June 2020
Resolved
Change out weld cable on port and starboard batteries.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2020
Resolved 19 June 2020
Resolution: Verified by attending MI: Mosley
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 June 2020
Resolved
Properly bond fuel-fill on starboard tank.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2020
Resolved 19 June 2020
Resolution: Verified by attending MI: Mosley
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 June 2020
Resolved
Air intake filters must be properly installed on main diesel engines and generator sets.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2020
Resolved 30 June 2020
Resolution: PIC sent via email...[name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 October 2019
Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps. Due 14Jan2020.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 January 2020
Resolved 14 April 2021
Resolution: Verified by [name withheld]
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 14 October 2019
Resolved
While underway or drifting at sea, every vessel shall at all times maintain a proper look-out by sight and hearing. The designated watchmen required by 46 CFR 185.410 cannot preform both roving patrolling and look-out watch simultaneously. Vessel has been instructed to operate with a look-out and watchman while conducting drift operations. Cleared on the spot.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 14 October 2019
Resolved 14 October 2019
Resolution: Educated operator.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 October 2019
Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from passenger and crew accommodation spaces below the main deck. Vessel did not have lighting at forward escape hatch. Install emergency lighting at forward escape hatch. Due 14Nov2019.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2019
Resolved 2 June 2020
Resolution: Def cleared during COI exam, [name withheld]
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 October 2019
Resolved
Install smoke detector in galley space. Due 14Nov2019.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2019
Resolved 2 June 2020
Resolution: Smoke detector installed witnessed by MI
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 October 2019
Resolved
Install the following:
1. Doors on breaker panels as identified,
2. Cover on breaker in accommodation closet,
3. Remove tape from breaker panels and install proper blanks.
Due 14Nov2019.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2019
Resolved 2 June 2020
Resolution: Def cleared during COI exam on 02JUN2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 October 2019
Resolved
Relocate outlet adjacent to air conditioning unit in accommodation space such that condensate from the air conditioning unit does not drip into the outlet. Due 14Nov2019.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2019
Resolved 2 June 2020
Resolution: New instalation witnessed by MI
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 14 October 2019
Resolved
All escape hatches and emergency exits used as means of escape must be marked on both sides in clearly legible letters that says "EMERGENCY EXIT, KEEP CLEAR". Emergency exit hatch from accommodation space was not marked on the top side on the main deck. Mark emergency escape as directed. Due 14Nov2019.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2019
Resolved 2 June 2020
Resolution: Witnessed by MI
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 14 October 2019
Resolved
Install valve handle on head suction valve. Due 14Nov2019.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2019
Resolved 2 June 2020
Resolution: Witnessed by MI
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 14 October 2019
Resolved
Replace broken bridge window. Due 14Nov2019.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2019
Resolved 2 June 2020
Resolution: Witnessed by MI
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 October 2019
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with §80.59 once every five years. Provide copy of safety certificate. Due 14Nov2019. Ref: 47CFR§80.903
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2019
Resolved 2 June 2020
Resolution: Deficiency was not rectified as of 02JUN2020 during the COI exam. Def was reissued on new 835V with no sail. See MISLE Activity #6963797 for details.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 June 2019
Resolved
Properly mount steering ram (4 bolts and bracket) to ensure free movement. Replace port side jockey bar mounting pin to fail safe mode (rotate 180 degrees).
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 June 2019
Resolved
Repair exhaust leak on starboard main engine.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 June 2019
Resolved
Repair 06 defective life jackets (1 light and 5 clips).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2019
Resolved 3 July 2019
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 25 June 2019
Resolved
Provide second master's credentials.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2019
Resolved 16 July 2019
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 25 June 2019
Resolved
Provide proof of Certificate of Documentation renewal application.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 July 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 June 2019
Resolved
Provide valid FFC Radio Safety Telephony Certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2019
Resolved 14 October 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 June 2019
Resolved
Replace welding cable on batteries with battery cable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2019
Resolved 3 July 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 June 2019
Resolved
Prove proper operation of high water alarms (visual and audio).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2019
Resolved 16 July 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 June 2019
Resolved
Install bonding wire at flex hose tank cross connections on port side fuel tank array.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2019
Resolved 16 July 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 June 2019
Resolved
Install blank over motor controller opening.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2019
Resolved 16 July 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 June 2019
Resolved
Install blanks over open circuit breaker panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2019
Resolved 16 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 June 2019
Resolved
Install lagging on starboard main engine exhaust up to jacket water inlet.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2019
Resolved 3 July 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 June 2019
Resolved
Install wire in panel board in engine room (aft bulkhead).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2019
Resolved 16 July 2019
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 25 June 2019
Resolved
Install gasket material around ventilation covers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2019
Resolved 16 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 June 2019
Resolved
Mount sea strainers with bracket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2019
Resolved 16 July 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 June 2019
Resolved
Mount compressed gas cylinder to permanent structure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2019
Resolved 16 July 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 June 2019
Resolved
Provide waste management plan that is specific to the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2019
Resolved 16 July 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 June 2019
Resolved
Vessel is overdue for annual inspection. Complete satisfactory annual inspection with USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2019
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 19 June 2019
Resolved
Provide FCC Marine Radio Operator Permits for licensed crew members.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2019
Resolved 16 July 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 21 June 2018
Resolved
Prove proper operational on forward watertight hatch and captive chain
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2018
Resolved 24 July 2018
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 June 2018
Resolved
Install cover on pilothouse 110 panel
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2018
Resolved 24 July 2018
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 June 2018
Resolved
Install cover on crew berthing 110 light
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2018
Resolved 24 July 2018
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 21 June 2018
Resolved
Prove proper operation on P & S E/R vents
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2018
Resolved 24 July 2018
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 June 2018
Resolved
Properly install 04 battery box covers
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2018
Resolved 24 July 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 June 2018
Resolved
Install double non corrosive hose clamps on flexible hose on berthing bilge pumping.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2018
Resolved 24 July 2018
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 21 June 2018
Resolved
Install current hydrostatic release mechanism on liferaft
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2018
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 June 2018
Resolved
Clean galley oven (fire hazard due to grease build up)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2018
Resolved 24 July 2018
04 - Emergency Systems › N/A - No Subsystem › Low level lighting in corridors
Issued 5 June 2018
Resolved
Install additional emergency light outside the crew berthing
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2018
Resolved 24 July 2018
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 5 June 2018
Resolved
Install cap on 2" valve in engine room
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2018
Resolved 24 July 2018