Records from 2007 to 2019. Most recent: inspection, 9 September 2019.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 September 2019
Resolved
Complete damage survey and make repairs to identified areas prior to the carriage of passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 October 2019
Resolution: COI surrendered, vessel to be destroyed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 30 July 2019
Resolved
Make anchor and stern navigation lights operational prior to operating at night.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 July 2019
Resolved 30 July 2019
Resolution: Verified operational.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 30 July 2019
Resolved
Mount fire pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2019
Resolved 8 October 2019
Resolution: COI surrendered, vessel to be destroyed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 30 July 2019
Resolved
Install double hose clamps on fire main flex hoses.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2019
Resolved 8 October 2019
Resolution: COI surrendered, vessel to be destroyed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 30 July 2019
Resolved
Install pressure gauge on discharge side of fire pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2019
Resolved 8 October 2019
Resolution: COI surrendered, vessel to be destroyed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 July 2019
Resolved
Install blanks in circuit breaker boxes (E/R & Galley).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2019
Resolved 8 October 2019
Resolution: COI surrendered, vessel to be destroyed.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 30 July 2019
Resolved
Provide ventilation closure devices for machinery space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2019
Resolved 8 October 2019
Resolution: COI surrendered, vessel to be destroyed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 July 2019
Resolved
Modify MOB ladder to allow for proper installation and install captive chain on ladder to prevent loss.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2019
Resolved 8 October 2019
Resolution: COI surrendered, vessel to be destroyed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 30 July 2019
Resolved
Plug/gag abandoned drain on port side aft machinery space through hull.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2019
Resolved 8 October 2019
Resolution: COI surrendered, vessel to be destroyed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 30 July 2019
Resolved
Tighten shaft packing on both shafts.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2019
Resolved 8 October 2019
Resolution: COI surrendered, vessel to be destroyed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 July 2019
Resolved
Repair coolant leak on port MDE.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2019
Resolved 8 October 2019
Resolution: COI surrendered, vessel to be destroyed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 July 2019
Resolved
Prove proper operation of bilge suction from the following spaces (1, 2, 3, 5)
Action required: 17 - Rectify deficiencies prior to departure
Due 23 July 2019
Resolved 30 July 2019
Resolution: Found operational
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 July 2019
Resolved
Install check valves in each bilge lines (1, 2, 3, 4, 5).
Action required: 17 - Rectify deficiencies prior to departure
Due 23 July 2019
Resolved 30 July 2019
Resolution: Check valves installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 July 2019
Resolved
Install screw-down valve in bilge line just aft of collision bulkhead.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 July 2019
Resolved 30 July 2019
Resolution: Installed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 July 2019
Resolved
Prove operation of fire main - repair defective valves and install spanner wrench.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 July 2019
Resolved 30 July 2019
Resolution: Repaired.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 23 July 2019
Resolved
Provide FCC Safety Radio Certs/Radio Operator permits.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 July 2019
Resolved 30 July 2019
Resolution: Provided.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 23 July 2019
Resolved
Replace all expired distress signals (x12)
Action required: 17 - Rectify deficiencies prior to departure
Due 23 July 2019
Resolved 30 July 2019
Resolution: Replaced 6 orange smoke and 6 rocket parachute
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 July 2019
Resolved
Ensure exhaust/water leak repaired on port exhaust pipe in steering space.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 July 2019
Resolved 30 July 2019
Resolution: crack on fiberglass repaired with fiberglass patch
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 July 2019
Resolved
Replace missing painter/weak link for life floats.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 July 2019
Resolved 30 July 2019
Resolution: Life floats removed, passenger count reduced to 50 persons total.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 July 2019
Resolved
Complete annual inspection and drills to satisfaction of attending marine inspector. (Post SPV Decal).
Action required: 17 - Rectify deficiencies prior to departure
Due 23 July 2019
Resolved 30 July 2019
Resolution: Inspection completed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 July 2019
Resolved
Prove proper operation of life-buoy light (1 of 2).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 August 2019
Resolved 30 July 2019
Resolution: Extra light removed from vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 July 2019
Resolved
Replace name marking/retro reflective material on life-jackets, life-buoys and life-floats as discussed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 August 2019
Resolved 30 July 2019
Resolution: Marked properly.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 July 2019
Resolved
Terminate dead-end wires in galley distribution panel and galley storage area.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 August 2019
Resolved 30 July 2019
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 July 2019
Resolved
Properly secure wiring to overhead or bulkhead in steering space (port side).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 August 2019
Resolved 30 July 2019
Resolution: Corrected.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 July 2019
Resolved
Log drills for MOB/Fire and EPIRB tests.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 August 2019
Resolved 30 July 2019
Resolution: Reviewed log entries.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 23 July 2019
Resolved
Provide charts for area of operations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 August 2019
Resolved 30 July 2019
Resolution: Provided onboard.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 23 July 2019
Resolved
Repair rudder angle indicator (off 15 degrees).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 August 2019
Resolved 30 July 2019
Resolution: Rudder angle indicator swings from 25P to 27S. Special note for dry-dock.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 23 July 2019
Resolved
Install captive chains or wire rope on all hatches exposed to the weather.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 August 2019
Resolved 30 July 2019
Resolution: Chains installed.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical first aid
Issued 23 July 2019
Resolved
Provide First Aid/CPR training cards for 50% of crew and master's MMC medical card/STCW training certificates.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 August 2019
Resolved 30 July 2019
Resolution: Provided.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 23 July 2019
Resolved
Repair magnetic compass light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 August 2019
Resolved 30 July 2019
Resolution: Repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 September 2018
Resolved
Both Port and STBD shaft packing glands are leaking beyond an acceptable rate of flow. Tighten packing to control rate of flow to an acceptable rate.
Action required: 10 - Deficiency Rectified
Due 24 September 2018
Resolved 24 September 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 September 2018
Resolved
Renew port main engine exhaust PEDRO hose.
Action required: 10 - Deficiency Rectified
Due 24 September 2018
Resolved 24 September 2018
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 20 September 2018
Resolved
Pump engine room bilge dry of oily/water mixture.
Action required: 10 - Deficiency Rectified
Due 24 September 2018
Resolved 24 September 2018
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 20 September 2018
Resolved
Port fuel oil wing tank return pipe currently has a temporary repair utilizing splash zone on a 90dg elbow and is currently weeping fuel. The elbow is located in the bilge area IVO R/G shaft coupling. Make permanent repairs to the satisfaction of the attending CHMI using approved pipe material. Repair by 01Nov2018. In the interim of repairs the tank shall be isolated and not used, to prevent fuel from leaking in to the bilge.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 November 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 August 2018
Resolved
Marine Casualty loss of main propulsion engines; clogged fuel filters.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 August 2018
Documentation › Logs/Records › Drug Test Records
Issued 11 June 2018
Resolved
Prove proper enrollment in chemical testing program for all crew.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 June 2018
Resolution: Vessel had negative test results for all crew members and application submitted to ASTS consortium.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 11 June 2018
Resolved
Prove proper maintenance of lifejacket lights.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2018
Resolved 15 June 2018
Resolution: All batteries replaced and logged in maintenance log.
Communications › Alarms/Indicators › High Water Alarm
Issued 11 June 2018
Resolved
Prove proper operation of bilge alarms.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 June 2018
Resolution: All switched replaced, proved proper operation, all sat.
Communications › Alarms/Indicators › Fire Alarm
Issued 11 June 2018
Resolved
Prove proper operation of al smoke detectors in passenger accommadations.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 June 2018
Resolution: All smoke alarms replaced, tested alarms, all sat.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 June 2018
Resolved
Prove operation of stern light
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 June 2018
Resolution: Bulb replaced, all sat.
Lifesaving › Lifefloat › Lifeline
Issued 11 June 2018
Resolved
Replace lifesaving line with 5/16" UV resistant.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2018
Resolved 8 October 2019
Resolution: COI surrendered, vessel to be destroyed.
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 30 March 2017
Resolved
Replace weak link on buoyant apparatus.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2017
Resolved 12 April 2017
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 30 March 2017
Resolved
Repair port deck house window.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 April 2017
Resolved 12 April 2017
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 29 August 2016
Resolved
Identify fuel oil leak on vessel to attending marine inspector.
Action required: 705 - Other - as specified
Due 27 September 2016
Resolved 17 October 2016
Resolution: Fuel oil leak identified as leak on Starboard tank.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 29 August 2016
Resolved
Submit plans for repairs for approval to teh attending marine inspector.
Action required: 705 - Other - as specified
Due 27 September 2016
Resolved 17 October 2016
Resolution: Plans submitted for repair of leak on fuel tank.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 29 August 2016
Resolved
Repair fuel leaks and demonstrate proper operation of the vessel fuel oil system.
Action required: 705 - Other - as specified
Due 27 September 2016
Resolved 30 November 2016
Resolution: New fuel tanks installed.