← All vessels
CHINOOK MAIDEN
CHINOOK MAIDEN is a 1996 tank ship. The Coast Guard has recorded 26 inspections since 1997, most recently in May 2012, along with 23 deficiencies — 1 with no resolution recorded — and 2 operational controls.
Records from 1997 to 2012. Most recent: inspection, 17 May 2012.
- Built
- 1996
- Last inspected
- 17 May 2012
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 23 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9145841 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3FWD6
450212
Flag
PANAMA
—
Maury page id
psix-450212
Inspections, by type
…with no type recorded11
…past their stated due date1
Years with a record
11 calendar years (1997–2012)
The 26 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it11956 - Regulatory (Subpart C or D), Net Ton
27915 - Regulatory (Subpart C or D), Gross Ton
27915 - Convention (Subpart B), Gross Ton
45217 - Dead Weight, Ton
55262 - Displacement, Ton
27915 - Regulatory (Subpart C or D), Gross Ton
27915 - Convention (Subpart B), Gross Ton
45217 - Dead Weight, Ton
55262 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 26
17 May 2012
Deficiency Check · Ballast Water Examination · ISPS II Exam · COC-CHEM Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4312923
14 December 2010
Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3908282
14 December 2010
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3911151
13 February 2010
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3679660
13 February 2010
PI Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3679762
13 February 2010
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3680570
3 February 2010
Ballast Water Examination · ISPS II Exam · COC-CHEM Renew
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3672411
9 May 2008
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3202961
14 March 2008
ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · COC-CHEM Annual
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3161005
22 July 2007
Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2992655
13 March 2007
COC-CHEM Renew · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2886699
22 June 2006
ISPS II Exam · COC-CHEM Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2688537
21 June 2006
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2687591
18 June 2006
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2683106
28 February 2005
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2300830
21 February 2005
Ballast Water Examination · COC-CHEM Renew · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2296492
5 April 2003
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1768565
17 February 2002
In-Service Inspection · Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1487175
28 December 2001
Administrative Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1474371
5 September 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 293544
16 January 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 286083
16 January 2001
Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1057096
12 August 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 418938
20 May 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 416186
29 July 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 406069
29 July 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 781288
Deficiency record · 23
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 3 February 2010
Resolved
1899-
Vessel's deck seal has a cooling water leak located on the fillet weld on the underside of the Inert Gas intake pipe. Vessel is to repair to the satisfaction of class within 14 days and prior to loading cargo requiring Inert Gas.
SOLAS 97 Cha II-2 Reg 62 (10.3)
16 A/C
Engineering › Lubricating Oil Service System › Pump
Issued 3 February 2010
Resolved
0820-
Oil pump located in engine room has a impeller shaft seal leak with cardboard being used as deflectors which poses a fire and safety hazard. Vessel is to repair to the satisfaction of class within 14 days.
SOLAS 04 Cha II-1 Reg 26.1
16 A/C
Deck/Cargo › Inert Gas System › Scrubber Tower
Issued 9 May 2008
Resolved
Vsl bypassed the scrubber hi water alarm. Test of all other IGS alarms was witnessed during an expanded exam of cargo sys w/sat results. Vsl may not conduct cargo ops until discharge plan/proposal is submitted to the USCG addressing safety concerns re bypassed alarm, specifically the equivalent lvl of safety during dischrg and op of IGS sys. Plan/proposal must incl terminal agreement.
Deck/Cargo › Inert Gas System › Scrubber Tower
Issued 9 May 2008
Resolved
Vsl bypassed scrubber high level alarm. IGS had marginal performance producing between 5% and 8% oxygen in the sys before the deal seal. Vsl may not conduct cargo ops until the proper op of the IGS is verified in all modes of op including shutdown and alarms by an attending flag state rep (NKK)
Documentation › Certificates/Documents › Certificate of Compliance (Fish)
Issued 9 May 2008
Resolved
The vsl is to make ready for an expanded Port State Control Exam in the area of cargo system safety. The vessel's Certificate of Compliance will be held by the USCG until further notice. The vessel may not depart port.
Deck/Cargo › Cargo Stowage › General
Issued 9 May 2008
Resolved
Vsl was found transferring cargo with cargo tanks at oxygen levels between 11% and 18% placing the vessel and the port in a hazardous condition. MOCC for this cargo is 11%. Vsl crew did not recognize the need to cease cargo operation.
Operations/Management › Vessel Safety Management › Resources and Personnel
Issued 9 May 2008
Resolved
Vsl failed to follow the safety management system with regard to operation of the IGS procedu7res to be followed (see MOL Tankship Management (Europe Ltd) Manual No. 140, pg 4/7) by continuing to conduct cargo discharge.
Deck/Cargo › Cargo Stowage › General
Issued 9 May 2008
Resolved
Vessel is equipped with only 1 operable portable oxygen analyzer.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Combustible Gas Indicator
Issued 9 May 2008
Resolved
Vessel did not maintain appropriate recording of the oxygen content in the inert gas supply mains during IGS operations on 8-9 May 2008
Deck/Cargo › Inert Gas System › IGS Scrubber
Issued 9 May 2008
Resolved
A spare for the level switch for the pump stop was not onboard the level switch for the high lvl alarm was used to replace the scrubbing pump stop switch. A part has been found but there is currently no confirmed part arrival date. As per NKK, the IGS system is temporarily fixed to satisfaction of class. Per NKK permanent repairs must be made by 10JUL08.
Lifesaving › Embarkation Appliances/Stations › Side Ropes
Issued 13 March 2007
Resolved
Upon deployment, the Stbd lifeboat embarkation ladder broke due to neglect and rot.
Engineering › Steering Gear System › Pump
Issued 13 March 2007
Resolved
#2 steering pump in NFU from bridge would not answer to port command.
Engineering › Steering Gear System › Linkage
Issued 13 March 2007
Resolved
Rudder angle indicator linkage arm missing anti-vibration device
Engineering › Generator (propulsion/auxiliary-electric) › Cable
Issued 13 March 2007
Resolved
*OTHER* Governor linkage on all four generators missing anti-vibration device.
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 13 March 2007
Resolved
Emergency fire pump did not engage; packing started to smoke and pressure was slow to build (more than 5 minutes).
Lifesaving › Launching Appliances › Hand Gear
Issued 13 March 2007
Resolved
Both P&S lifeboat lowering actuator for the coxswain is not adjusted to allow lifeboat to fully deploy as wire rope linkage is fouled at lifeboat overhead opening.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 13 March 2007
Resolved
Vessel crew is using a checklist for unmanned space operation with the same control number as a different checklist in the SMS. The instructions for keeping the records are vague.
Documentation › Logs/Records › Oil Record Book
Issued 13 March 2007
Resolved
The oil record book shows that the oily water seperator has not been used since 09FEB07. The solinoid to the primary chamber is hot (very warm to the touch) indicating a fouled probe. Vessel was underway from approx. 21 days between 9FEB and 13MAR07. Perform operational test to the satisfaction of class.
Construction/Loadline
Issued 5 September 2001
Resolved
Loadline markings rusted and opposing color faded.
Engineering
Issued 12 June 2001
No resolution recorded
RECEIVED CLASS REPORT, EXTENDED COMPLIANCE DATE TO PERMANENTLY REPAIR LEAKING TEMPORARY REPAIR ON M/E LUBE OIL COOLER SALT WATER OUTLET PIPE.
Engineering
Issued 16 January 2001
Resolved
Permanently repair leaking temporary repair on M/E lube oil cooler S/W outlet pipe to satisfaction of class.
Deck/Cargo
Issued 29 July 1997
Resolved
Cargo pressure/vacuum valves not properly serviced. Provide documentation attesting to the proper testing and inspection of the pressure/vacuum relief valves IAW 33 CFR 156.170 prior to 29Aug97.
Lifesaving
Issued 29 July 1997
Resolved
EEBA's and SCBA's not serviced IAW IBC 14.2.6. Provide service reports forthe servicing of the EEBA's and SCBA's prior to 29Aug97.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.