Records from 2016 to 2021. Most recent: inspection, 7 June 2021.
Documentation record
Registered dimensions (L × B × D)34.7 ft × 13.2 ft × 7.2 ft
Registered tonnagegross 22 / net 17
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSOUND MARINE WORKS · BELFAST ME, UNITED STATES · built 1997
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEW BEDFORD, MA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 17 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it17 - Simplified, Net Ton
22 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 9
7 June 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7205063
23 March 2020
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6928523
10 December 2019
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6871318
9 August 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6496291
26 April 2018
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6418008
4 August 2017
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6230029
20 June 2016
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 5913267
28 March 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5835138
16 March 2016
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5834340
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 December 2019
No resolution recorded
Complete COI renewal inspection.
Due 13 January 2021 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 August 2018
No resolution recorded
A vessel must have a properly functioning means of propulsion. Vessel's main diesel engine is not functioning as designed.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 October 2018 — due date passed with no resolution recorded
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 17 August 2018
No resolution recorded
A Vessel must be able to demonstrate the ability to conduct a fire drill. The vessel was unable to run it's main diesel engine prohibiting it from conducting a satisfactory fire drill.
Action required: 701 - Prior to carriage of passengers/cargo
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 17 August 2018
No resolution recorded
A Vessel must be able to demonstrate the ability to conduct a man overboard drill. The vessel was unable to get underway prohibiting it from conducting a satisfactory man overboard drill.
Action required: 701 - Prior to carriage of passengers/cargo
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 August 2018
Resolved
Vessel must have properly functioning bilge high level alarms. Vessels forward most high level alarm was found to be inoperative.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 June 2021
Resolution: See Activity Number 7205063
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 August 2018
No resolution recorded
Passenger vessel must maintain at least one ring buoy onboard for uses. Vessel was found to not have a adequate ring buoy for uses.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 17 August 2018
No resolution recorded
Vessel must have a serviceable life float ready for deployment on board. Vessel's life float was found to be in disrepair.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 29 June 2016
Resolved
The batteries in the water lights were expired. Replace batteries.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 June 2016
Resolved 29 June 2016
Resolution: Corrected on the spot.
Fire Fighting › Fire Bucket › Availability
Issued 29 June 2016
Resolved
Vessel doed not have required fire buckets. Provide fire buckets.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 June 2016
Resolved 29 June 2016
Resolution: Corrected on the spot.
Construction/Loadline › Hull › Bottom Plating
Issued 16 March 2016
Resolved
Prior to carrying passengers, complete the credit dry-dock and internal structural exams.
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 1 April 2016
Resolution: Completed drydock exam.