MAURY USCG vessel records Sign in
← All vessels

EMILY PG

EMILY PG is a 1996 tank ship. The Coast Guard has recorded 26 inspections since 1997, most recently in September 2018, along with 21 deficiencies and 7 operational controls.

Records from 1997 to 2018. Most recent: inspection, 23 September 2018.

Built
1996
Last inspected
23 September 2018
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9130470 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
450336
Flag
ISLE OF MAN
—
Maury page id
psix-450336

Inspections, by type

…with no type recorded12
Years with a record 11 calendar years (1997–2018)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it1892 - Convention (Subpart B), Net Ton
6249 - Dead Weight, Ton
8156 - Displacement, Ton
3627 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 26

23 September 2018 Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6544008
14 May 2017 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6144631
13 September 2011 COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4140098
8 February 2011 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3941228
8 October 2010 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3859664
18 September 2010 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3849678
7 January 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3660437
3 December 2009 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3644224
15 July 2009 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3535521
7 April 2009 Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3456472
23 September 2008 Ballast Water Examination · MARPOL Annex I Examination · Loadline Exam · MARPOL Annex V Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3330726
6 April 2007 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2902822
28 April 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2635523
25 April 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2633300
9 January 2006 COC-TVE Annual · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2563755
6 May 2005 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2350976
19 September 2004 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2199449
18 September 2004 MARPOL Annex I Examination · COC-TVE Renew
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2194327
18 September 2004 ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2199018
11 September 2004 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2193228
14 December 1997 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 410745
14 December 1997 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 411771
14 December 1997 Tank Vessel Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 779520
25 March 1997 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 401996
12 March 1997 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 401496
2 January 1997 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 398914

Deficiency record · 21

Lifesaving › Launching Appliances › Davit
Issued 13 September 2011 Resolved
Rescue boat wire parted after limit switch and motor controller failed. Switch and controller repaired and operational. Renew wire and prove operation to satisfaction of flag or a recognized organization prior to departure.
Action required: 705 - Other - as specified
Due 13 September 2011
Resolved 13 September 2011
Resolution: Repairs approved by class.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 18 September 2010 Resolved
1570 The operator of each self propelled vessel 12 meters or more in length shall carry on board and maintain a copy of Inland Navigational Rules Act of 1980. Vessel does not have a copy of Inland Navigational Rules. 33aCFR 88.05 50C
Action required: 705 - Other - as specified
Due 18 October 2010
Resolved 8 October 2010
Resolution: Recieved conformation that vessel had purchased and recieved Inland Rules of the Road.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 18 September 2010 Resolved
1730 The OWS was inoperable due to worn parts. Prior to operating the OWS and before 18OCT2010 make permanent repairs to OWS to satisfaction of attending USCG Inspector. 50C
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 October 2010
Resolved 8 October 2010
Resolution: Recieved class report attesting to repairs and also recieved new IOPP with updated OWS.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 28 April 2006 Resolved
Echo Depth Sounding Device inoperative. Vessel received Letter of Deviation for departure.
Action required: 705 - Other - as specified
Due 7 June 2006
Resolved 29 July 2006
Resolution: Master send a letter stating that they installed a new echo depth sounder and that is fully operational.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 18 September 2004 Resolved
Door has been removed from between engine room workshop and engine room storeroom. Update fire control plan to reflect removal of door or replace door, to the satisfaction of class prior to next U.S. port.
Action required: 15 - Rectify deficiencies by next port
Resolved 20 September 2004
Resolution: Door has been replaced.
Deck/Cargo › Cargo Stowage › General
Issued 18 September 2004 Resolved
Remove flammable and commbustible liquids stored in drums on deck prior to cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2004
Resolution: Drums have been removed.
Deck/Cargo › Cargo Stowage › General
Issued 18 September 2004 Resolved
Remove washing machine from steering grear room prior to next U.S. port.
Action required: 15 - Rectify deficiencies by next port
Resolved 19 September 2004
Resolution: Washing machine has been removed.
Communications › Internal Communications System › Sound-powered Telephone
Issued 18 September 2004 Resolved
Repair means of communication through out the vessel. Prior to next U.S. port to the satisfaction of class. Until corrected provide alternate means of communication.
Action required: 15 - Rectify deficiencies by next port
Resolved 6 May 2005
Resolution: Communications tested satisfactory (aft steering wheel house)
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 18 September 2004 Resolved
Anchor chain to be renewed.
Action required: 705 - Other - as specified
Resolved 6 May 2005
Resolution: Sighted Lloyds Register Class report certifying vessel attended 6 October 2004. Port and starboard anchors and entire chain cable examined, ranged and calibrated. Chain reinstated with rule requirements
Construction/Loadline › Hull › Bracket
Issued 18 September 2004 Resolved
Bonding agent for coupling adjacent to #3 STBD tank to be earthed with stainless steel strip.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2004
Resolution: Bonding agent has been replaced.
Documentation › Certificates/Documents › IOPP Certificate
Issued 18 September 2004 Resolved
Make changes to the IOPP certifiacte to reflect the change from SOPEP to SMPEP.
Action required: 15 - Rectify deficiencies by next port
Resolved 6 May 2005
Resolution: Sighted correspondence from Isle of Man Marine Administration stating Certificate is in Compliance.
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 18 September 2004 Resolved
Make repairs to the SCBA valve that is malfunctioning. The number of SCBA's must match the safety equipment certificate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 September 2004
Resolution: Repair has been made.
Navigation › Collision/Grounding Avoidance › Radar
Issued 18 September 2004 Resolved
Make repairs to the port radar.
Action required: 15 - Rectify deficiencies by next port
Resolved 19 September 2004
Resolution: Rcvd tech report stating that the radar has been repaired.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 11 September 2004 Resolved
Make repairs to the echo depth sounding device. Rcvd letter from Flag state stating that it will be repaired at next drydock.
Action required: 705 - Other - as specified
Due 28 February 2005
Resolved 6 May 2005
Resolution: Witnessed satisfactory operation of depth sounder
Deck/Cargo
Issued 2 January 1997 Resolved
ATTACH BONDING STRAPS ON CARGO PIPING.
Condition: Unknown
Due 3 January 1997
Resolved 19 March 1997
Documentation
Issued 2 January 1997 Resolved
TO SOPEP AND VESSEL RESPONSE PLAN ADD USCG, AND DPNR (FOR U.S.V.I.) AND THEAPPROPRIATE AGENCIES FOR PUERTO RICO.
Condition: Unknown
Due 27 March 1997
Resolved 27 March 1997
Deck/Cargo
Issued 2 January 1997 Resolved
ON #1 STBD BULLET VALVE, MAKE PERNAMENT REPAIRS TO ALLOW FOR THE MANUAL OPERATION OF VALVE.
Condition: Unknown
Due 3 January 1997
Resolved 19 March 1997
Deck/Cargo
Issued 2 January 1997 Resolved
MARK HOSES IAW 33CFR154.500.
Condition: Unknown
Due 27 March 1997
Resolved 27 March 1997
Deck/Cargo
Issued 2 January 1997 Resolved
INSTALL STUD ON VAPOR CONTROL SYSTEM MANIFOLD.
Condition: Unknown
Due 3 January 1997
Resolved 19 March 1997
Deck/Cargo
Issued 2 January 1997 Resolved
MAKE PERNAMENT REPAIRS TO 98 PERCENT OVERFILL ALARM TO #1 PORT CARGO TANK.
Condition: Unknown
Due 3 January 1997
Resolved 19 March 1997
Deck/Cargo
Issued 2 January 1997 Resolved
PROVE PROPER OPERATION OF OIL DISCHARGE MONITORING UNIT. VESSEL IS NOT ALLOWED TO DISCHARGE BALLAST WATER UNTIL UNIT IS OPERATIONAL.
Condition: Unknown
Due 27 March 1997
Resolved 27 March 1997

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.