Records from 1983 to 2009. Most recent: inspection, 20 July 2009.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 40
20 July 2009
Internal Structural Exam · Periodic Inspection · Hull Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3534618
13 November 2008
Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3361608
26 October 2007
Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3085510
25 July 2006
COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2718461
3 November 2005
Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2525843
10 June 2005
Administrative Inspection
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2385825
14 October 2004
Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2221428
17 May 2004
Hull Examination · Internal Structural Exam
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2070280
7 January 2004
Administrative Inspection
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1977653
25 August 2003
Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1887052
17 December 2002
Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1720201
9 August 2001
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1069491
17 July 2001
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1471929
28 June 2001
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1401510
25 August 1999
Deficiency Check · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1397236
2 August 1999
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1404796
11 June 1998
Deficiency Check · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1465406
14 August 1997
Re-Inspection · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1383674
17 October 1996
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 846267
12 June 1996
Hull Examination · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1371427
14 April 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1078017
10 November 1994
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1363142
7 December 1993
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 848997
10 November 1992
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1420676
29 May 1991
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 929384
2 October 1990
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 931454
30 August 1990
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1240571
26 June 1989
Deficiency Check · COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1341216
18 October 1988
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 888021
1 September 1988
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1348751
27 August 1987
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1004086
24 June 1986
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1303945
13 May 1986
Credit Drydock
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1303688
9 April 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 999349
15 February 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1283940
20 July 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1281496
22 June 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 974221
3 May 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 974183
9 March 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1276187
8 March 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 967094
Communications › Public Address System › Announcing Station
Issued 24 August 2009
Resolved
Install public address system per 46 CFR 184.610 (a) & (b)
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 September 2009
Resolved 24 September 2009
Resolution: Vessel procured and installed public address system meeting the requirements of 46 CFR 184.610.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 26 October 2007
Resolved
Provide proof of purchase for new charts (Replace Outdated Charts).
Due 26 October 2007
Resolved 27 October 2007
Resolution: Received fax receipt for purchase of new charts.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 26 October 2007
Resolved
Provide proof of current EPIRB registration (Replace Sticker).
Due 26 October 2007
Resolved 27 October 2007
Resolution: Received fax attesting to registration of vessels 406 EPIRB.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 17 December 2002
Resolved
Two extinguisers were discharged and needed to be serviced
Due 17 December 2002
Resolved 17 December 2002
Resolution: Crew replaced discharged extinguishers with two serviced extingishers.
Navigation › Piloting/Steering
Issued 17 December 2002
Resolved
Vessel did not have the most current edition of NAVRULS on board. LEGACY COMPONENT DESC: Inland Navigation Rules
Due 17 January 2003
Resolved 18 December 2002
Resolution: Obtained current version of NAVRULS.
Engineering › Steering Gear System
Issued 17 December 2002
Resolved
Rudder needed to be adjusted so that contact with rudder stop would cease. LEGACY COMPONENT DESC: Rudder
Due 17 January 2003
Resolved 18 December 2002
Resolution: Stops adjusted by crew.
Electrical › Lighting (service)
Issued 17 December 2002
Resolved
Crew was directed to replace melted plastic gloge over port MDE exhust. LEGACY COMPONENT DESC: Lighting Fixture
Due 17 December 2002
Resolved 17 December 2002
Resolution: Crew replaced plastic globe with a glass type globe and globe cage.
Engineering › Fuel Oil Service System › Valve, Control
Issued 17 December 2002
Resolved
Emergency fuel shut off valve was not properly labeled.
Due 17 December 2002
Resolved 17 December 2002
Resolution: Crew properly labeled emergency fuel shut-off valve.
Operations/Management › Equipment Service/Testing
Issued 17 December 2002
Resolved
Several WTD's were not properly labeled throughout the vessel.
Condition: Unknown
Due 17 December 2002
Resolved 17 December 2002
Resolution: Crew properly labeled WTD''s throughout the vessel.
Fire Fighting
Issued 17 July 2001
Resolved
Provide second axe per COI and stencil both axes with vessels name.
Condition: Unknown
Due 18 July 2001
Resolved 18 July 2001
Accommodation/Occupational Safety
Issued 17 July 2001
Resolved
Properly label all emergency exits "emergency exit keep clear".
Condition: Unknown
Due 17 July 2001
Resolved 17 July 2001
Navigation
Issued 17 July 2001
Resolved
Provide vessel with emergency broadcast placard in wheelhouse
Condition: Unknown
Due 18 July 2001
Resolved 18 July 2001
Construction/Loadline
Issued 17 July 2001
Resolved
Repair or replace gasket to rudder room, existing gasket has been painted.
Condition: Unknown
Due 17 July 2001
Resolved 17 July 2001
Electrical
Issued 25 August 1999
Resolved
Provide for emergency lighting to illuminate the stairway in the galley andpump room.
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Construction/Loadline
Issued 25 August 1999
Resolved
Provide a bilge alarm system to meet the requirements of 46CFR 182.530 for the engine room, aft steering and pump room. Vessel has a bilge alarm for the engine room but it does not meet new requirements.
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Electrical
Issued 11 June 1998
Resolved
REMOVE DISCONNECTED DEAD ENDED WIRES LOCATED ON BULK HEAD IN PORT PASSAGEWAY._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 July 1998
Resolved 19 July 1998
Engineering
Issued 11 June 1998
Resolved
INSTALL MACHINERY GUARDS ON FIRE PUMP MONITOR PRIME MOVER, STARBOARD GENERATOR, AND BOTH MDE'S._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 July 1998
Resolved 19 July 1998
Lifesaving
Issued 11 June 1998
Resolved
RENEW RUBBER MATTING IN FRONT OF SWITHBOARD AND INSTALL RUBBER MATTING BEHIND SWITHBOARD.
Condition: Unknown
Due 11 July 1998
Resolved 19 July 1998
Fire Fighting
Issued 11 June 1998
Resolved
TIGHTEN OR RENEW SHAFT PACKING ON FIRE MONITIOR PUMP DUE TO LEAKAGE.
Condition: Unknown
Due 11 July 1998
Resolved 19 July 1998
Construction/Loadline
Issued 14 August 1997
Resolved
Plug unused stuffing tubes in aft engine room bulkhead
Condition: Unknown
Due 18 August 1997
Resolved 29 September 1997
Electrical
Issued 14 August 1997
Resolved
secure loose wire in junction boxes located in diesel fire pump room overhead.
Condition: Unknown
Due 18 August 1997
Resolved 29 September 1997
Construction/Loadline
Issued 14 August 1997
Resolved
Renew CVK in steering gear room
Condition: Unknown
Due 18 August 1997
Resolved 29 September 1997
Construction/Loadline
Issued 14 August 1997
Resolved
Renew port corner wrapper and shell plate in way of frames 1 & 2 from aft in rudder room starboard side. (excessive deterioration & hole.)
Condition: Unknown
Due 18 August 1997
Resolved 29 September 1997
Electrical
Issued 14 August 1997
Resolved
Label switches iwo ports side of pilot house aft of breaker box.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Electrical
Issued 14 August 1997
Resolved
Install cover to stbd breaker box on pilot house
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Electrical
Issued 14 August 1997
Resolved
Label panel & renew indicating bulb in pilot house (for steering pump motor)
Condition: Unknown
Due 18 August 1997
Resolved 29 September 1997
Electrical
Issued 14 August 1997
Resolved
Label breakers in port breaker box (pilot house)
Condition: Unknown
Due 18 August 1997
Resolved 29 September 1997
Fire Fighting
Issued 14 August 1997
Resolved
Provide approval for fire extinguisher brackets.
Condition: Unknown
Due 18 August 1997
Resolved 29 September 1997
Construction/Loadline
Issued 14 August 1997
Resolved
Label dogging wheel or emergency escape scuttle in crews berthing
Condition: Unknown
Due 18 August 1997
Resolved 29 September 1997
Electrical
Issued 14 August 1997
Resolved
Label switchs in A.C. storage space.
Condition: Unknown
Due 18 August 1997
Resolved 29 September 1997
Navigation
Issued 14 August 1997
Resolved
Double nut or pin control arms
Condition: Unknown
Due 18 August 1997
Resolved 29 September 1997
Lifesaving
Issued 14 August 1997
Resolved
Install guards on sight glasses in engine room
Condition: Unknown
Due 18 August 1997
Resolved 29 September 1997
Construction/Loadline
Issued 14 August 1997
Resolved
Renew transverse frame #3 in way of stuffing boxes in engine room
Condition: Unknown
Due 14 August 1997
Resolved 29 September 1997
Engineering
Issued 14 August 1997
Resolved
Tighten engining mounting bolts on stbd main diesel enging
Condition: Unknown
Due 18 August 1997
Resolved 29 September 1997
Construction/Loadline
Issued 14 August 1997
Resolved
Adjust or regaskert engine room water tight door
Condition: Unknown
Due 18 August 1997
Resolved 29 September 1997
Electrical
Issued 14 August 1997
Resolved
Adjust overspeed trips on both ship service generators
Condition: Unknown
Due 18 August 1997
Resolved 29 September 1997
Fire Fighting
Issued 14 August 1997
Resolved
Install pressure gauge on fire pump
Condition: Unknown
Due 18 August 1997
Resolved 29 September 1997
Electrical
Issued 14 August 1997
Resolved
Secure amp meter on switch board
Condition: Unknown
Due 18 August 1997
Resolved 29 September 1997
Engineering
Issued 30 August 1990
Resolved
PROVIDE GUARDS FOR PROPULSION ENGINES EXPANSION TANK SIGHT GLASSES.
Condition: Unknown
Due 30 August 1990
Resolved 30 August 1990
Electrical
Issued 30 August 1990
Resolved
PROVIDE GLOBE AND GUARD FOR LIGHT FIXTURES IN MACHINERY SPACES, LOCATED ABOVE STBD PROPULSION ENGINE, STEERING SPACE.
Condition: Unknown
Due 30 August 1990
Resolved 30 August 1990
Construction/Loadline
Issued 30 August 1990
Resolved
MARK STERN OF VESSEL WITH NAME AND HAILING PORT.
Condition: Unknown
Due 30 August 1990
Resolved 30 August 1990
Navigation
Issued 30 August 1990
Resolved
PROVIDE ON BOARD VSL THE FOLLOWING PUBLICATIONS; 46CFR SUBCHAPTER 41-69, 90-139 & 33CFR 1-199; REQUIRED NOTICE TO MARINERS; LAWS GOVERNING MARINE INSPECTION(2COPIES); TIDE/CURRENT TABLES AND A CURRENT COMPASS DEVAITION TABLE.
Condition: Unknown
Due 30 August 1990
Resolved 30 August 1990
Electrical
Issued 30 August 1990
Resolved
PROVIDE MACHINERY SPACE WITH GENERAL ALARM BELL CAPABLE OF BEING HEARD ABOVE THE NOISE OF ALL OPERATING MACHINERY OR INSTALL A ROTATING LIGHT IN ALL SPACES.
Condition: Unknown
Due 30 August 1990
Resolved 30 August 1990
Construction/Loadline
Issued 30 August 1990
Resolved
ADJUST FORWARD MACHINERY SPACE WATER TIGHT DOOR TO ENSURE PROPER CLOSURE.
Condition: Unknown
Due 30 August 1990
Resolved 30 August 1990
Fire Fighting
Issued 1 September 1988
Resolved
REMOVE FLEXIBLE HOSE ON FIREMAIN PIPING AND INSTALL PERMANENT PIPING IN THE AUXILIARY MACHINERY SPACE.
Condition: Unknown
Due 1 September 1988
Resolved 1 September 1988
Navigation
Issued 1 September 1988
Resolved
PROVIDE MEANS TO ISOLATE ALTERNATE STEERING SYSTEM FROM MAIN STEERING SYSTEM.
Condition: Unknown
Due 1 September 1988
Resolved 1 September 1988
Electrical
Issued 1 September 1988
Resolved
PERMANENTLY INSTALL THE BATTERY CHARGER IN THE ENGINE ROOM USED FOR THE SHIP'S SERVICE GENERATOR STARTING BATTERY.
Condition: Unknown
Due 1 September 1988
Resolved 1 September 1988
Fire Fighting
Issued 1 September 1988
Resolved
PROVE DIESEL DRIVEN FIRE PUMP CANNOT EXCEED 25PSI ABOVE FIREMAIN PRESSURE. INSTALL RELIEF VALVE IF REQUIRED.
Condition: Unknown
Due 1 September 1988
Resolved 1 September 1988
Electrical
Issued 1 September 1988
Resolved
INSTALL AND TEST BULBS FOR THE ENGINE ROOM SWITCHBOARD GROUND DETECTION LIGHTS.
Condition: Unknown
Due 1 September 1988
Resolved 1 September 1988
Engineering
Issued 1 September 1988
Resolved
INSTALL AND TEST OVERSPEEDS ON PROPULSION MAINS.
Condition: Unknown
Due 1 September 1988
Resolved 1 September 1988
Unknown
Issued 1 September 1988
Resolved
INSTALL FIXED PIPING FOR FUEL OIL TRANSFER PUMPS IN THE ENGINE ROOM.
Condition: Unknown
Due 1 September 1988
Resolved 1 September 1988
Accommodation/Occupational Safety
Issued 24 June 1986
Resolved
REPAIR THE GENERAL ALARM BELL LOCATED IN THE ENGINE ROOM.
Condition: Unknown
Due 24 June 1986
Resolved 24 June 1986
Navigation
Issued 24 June 1986
Resolved
PROVIDE THE VESSEL WITH CURRENT EDITIONS OF THE U. S. COAST GUARD LIGHT LIST, VOLUME II AND NAVIGATIONAL RULES, INTERNATIONAL-INLAND.
Condition: Unknown
Due 24 June 1986
Resolved 24 June 1986
Unknown
Issued 22 June 1984
Resolved
REPAINT THE VESSEL NAME AND THE HAILING PORT ON THE STERN OF THE VESSEL IN LETTERS OF NOT LESS THAN FOUR INCHES.
Condition: Unknown
Due 22 June 1984
Resolved 22 June 1984
Unknown
Issued 22 June 1984
Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE PHYLLIS, DN500409.
Condition: Unknown
Due 22 June 1984
Resolved 22 June 1984
Unknown
Issued 3 May 1984
Resolved
PAINT THE VESSEL'S NAME AND HOMEPORT ON THE STERN.
Condition: Unknown
Due 3 May 1984
Resolved 3 May 1984
Lifesaving
Issued 3 May 1984
Resolved
VESSEL IS LIMITED TO 19 PERSONS ON BOARD UNTIL ONE ADDITIONAL PFD IS PROVIDED.
Condition: Unknown
Due 3 May 1984
Resolved 3 May 1984
Deck/Cargo
Issued 3 May 1984
Resolved
REPLACE THE DEFECTIVE END CAP ON THE ANCHOR WINDLASS OR MAKE MODIFICATIONS TO PREVENT PERSONNEL INJURY HAZARD.
Condition: Unknown
Due 3 May 1984
Resolved 3 May 1984
Navigation
Issued 3 May 1984
Resolved
EQUIP VESSEL WITH "NOT UNDER COMMAND" LIGHTS.
Condition: Unknown
Due 3 May 1984
Resolved 3 May 1984
Unknown
Issued 3 May 1984
Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE PHYLLIS, DN500409.
Condition: Unknown
Due 3 May 1984
Resolved 3 May 1984