MAURY USCG vessel records Sign in
← All vessels

FOSTER PARKER

FOSTER PARKER is a 1965 unclassified. The Coast Guard has recorded 14 inspections since 1982, most recently in June 1987, along with 24 deficiencies.

Records from 1982 to 1987. Most recent: inspection, 1 June 1987.

Built
1965
Last inspected
1 June 1987
Documentation
Invalid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-45040

Inspections, by type

…with no type recorded11
Years with a record 5 calendar years (1982–1987)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 39 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)350.0 ft × 100.0 ft × 24.3 ft
Registered tonnagegross 5,317 / net 5,317
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · HOUSTON, TX, UNITED STATES · built 1965
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNot recorded
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationInvalid
Service, as the file records itUnclassified
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it5317 - Regulatory (Subpart C or D), Gross Ton
5317 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 14

1 June 1987 Administrative
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1339068
17 December 1986 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1019560
25 November 1986 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1019177
31 October 1986 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1320048
27 October 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1326182
10 September 1986 Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1276061
16 July 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1297094
27 March 1986 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 998166
15 March 1986 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 991904
13 September 1985 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1302336
18 May 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1288415
7 January 1985 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1284125
14 August 1984 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 973720
9 July 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1275479

Deficiency record · 24

Engineering
Issued 17 December 1986 Resolved
PRIOR TO PLACING VESSEL IN NAVIGATION DEMONSTRATE PROPER OPERATION OF MACHINERY SPACE OILY WATER SEPARATING SYSTEM TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 18 May 1987
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 31 October 1986 Resolved
MAKE PERMANENT REPAIRS TO THE GENERAL SERVICE AIR COMPRESSOR AND DEMONSTRATE PROPER OPERATION OF AIR RECEIVER SAFETY RELIEF VALVE.
Condition: Unknown
Due 31 October 1986
Resolved 31 October 1986
Unknown
Issued 10 September 1986 Resolved
MAKE PERMANENT REPAIRS TO GENERAL SERVICE AIR COMPRESSOR AND DEMONSTRATE PROPER OPERATION OF AIR RECEIVER SAFETY RELIEF VALVE.
Condition: Unknown
Due 10 September 1986
Resolved 10 September 1986
Unknown
Issued 10 September 1986 Resolved
PRESENT THE FOLLOWING AIR RECEIVERS FOR COAST GUARD INTERNAL INSP: THREE (3) SHIPS SERV., THREE (3) VOLUME AIR, TWO (2) STARTING AIR AND ONE (1) DIESEL START.
Condition: Unknown
Due 10 September 1986
Resolved 10 September 1986
Unknown
Issued 16 July 1986 Resolved
LABEL REMOTE FUEL OIL SHUTOFFS.
Condition: Unknown
Due 16 July 1986
Resolved 16 July 1986
Unknown
Issued 16 July 1986 Resolved
DEMONSTRATE SATISFACTORY OPERATION OF RELIEF VALVES ON NINE (9) AIR RECEIVERS.
Condition: Unknown
Due 16 July 1986
Resolved 16 July 1986
Electrical
Issued 16 July 1986 Resolved
PROVE PROPER OPERATION OF #1 AND #2 SHIP'S SERVICE GENERATORS IN PARALLEL.
Condition: Unknown
Due 16 July 1986
Resolved 16 July 1986
Electrical
Issued 16 July 1986 Resolved
DEMONSTRATE PROPER OPERATION OF REVERSE POWER RELAYS ON BOTH SHIP'S SERVICEGENERATORS.
Condition: Unknown
Due 16 July 1986
Resolved 16 July 1986
Electrical
Issued 16 July 1986 Resolved
DEMONSTRATE PROPER OPERATION OF #1 AND #2 SHIP'S SERVICE GENERATOR OVER- SPEED TRIPS.
Condition: Unknown
Due 16 July 1986
Resolved 16 July 1986
Navigation
Issued 16 July 1986 Resolved
REPAIR STERN LIGHT WIRING.
Condition: Unknown
Due 16 July 1986
Resolved 16 July 1986
Unknown
Issued 16 July 1986 Resolved
HYDROSTATICALLY TEST FIRE TUBE BOILER TO 1.25X MAWP.
Condition: Unknown
Due 16 July 1986
Resolved 16 July 1986
Electrical
Issued 16 July 1986 Resolved
PROVIDE GUARD FOR #1 SHIP SERVICE GENERATOR SHAFT.
Condition: Unknown
Due 16 July 1986
Resolved 16 July 1986
Construction/Loadline
Issued 16 July 1986 Resolved
PLUG HOLES IN WATERTIGHT BULKHEADS THROUGHOUT ENGINE AND BOILER ROOMS.
Condition: Unknown
Due 16 July 1986
Resolved 16 July 1986
Documentation
Issued 16 July 1986 Resolved
PROVIDE IOPP CERTIFICATE FOR ENDORSEMENT.
Condition: Unknown
Due 30 August 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 15 March 1986 Resolved
MAKE PERMANENT REPAIRS TO THE TEMPORARY REPAIRS MADE TO THE NO. 2 STBD BOW RAKE COMPARTMENT EXTERNAL HULL PLATING. REPAIRS TO BE MADE BACK TO ORIGINAL INCLUDING ALL INTERNAL ASSOCIATED FRAMING MEMBERS. ALL REPAIRS SHALL BE MADE TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Unknown
Issued 18 May 1985 Resolved
TEST THE ALARMS, REVERSE CURRENT RELAYS, AND OVERSPEED TRIPS ON ALL GENERATORS.
Condition: Unknown
Due 18 May 1985
Resolved 18 May 1985
Unknown
Issued 18 May 1985 Resolved
TEST THE OPERATION OF THE ANCHOR WINDLASS.
Condition: Unknown
Due 18 May 1985
Resolved 18 May 1985
Unknown
Issued 18 May 1985 Resolved
CROP AND RENEW APPROXIMATELY 6' X 3' X 7/16" AREA OF TANK TOPS IN THE PUMP ROOM.
Condition: Unknown
Due 18 May 1985
Resolved 18 May 1985
Unknown
Issued 14 August 1984 Resolved
CONDUCT A 1/4 MAWP HYDROSTATIC TEST OF THREE VOLUME AIR RECEIVERS.
Condition: Unknown
Due 14 August 1984
Resolved 14 August 1984
Unknown
Issued 14 August 1984 Resolved
PLACE ONBOARD VESSEL ONE SET OF OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 14 August 1984
Resolved 14 August 1984
Unknown
Issued 14 August 1984 Resolved
REPALCE "PUSH-ON" TYPE FUEL HOSES ON A DIESEL ENGINES WITH WIRE RE-INFORCEDFLEXIBLE HOSE.
Condition: Unknown
Due 14 August 1984
Resolved 14 August 1984
Unknown
Issued 14 August 1984 Resolved
STENCIL VESSEL'S NAME ON ALL FIRE HOSES.
Condition: Unknown
Due 14 August 1984
Resolved 14 August 1984
Unknown
Issued 14 August 1984 Resolved
REPAIR AND CONDUCT OPERATIONAL TEST OF ALL GENERAL ALARM CONTACTORS.
Condition: Unknown
Due 14 August 1984
Resolved 14 August 1984
Unknown
Issued 14 August 1984 Resolved
REVISE OR UPDATE FIRE CONTROL PLAN TO CONFORM EQUIPMENT ON VESSEL.
Condition: Unknown
Due 14 August 1984
Resolved 14 August 1984

Ownership record