← All vessels
CRISTINA K
CRISTINA K is a 1977 freight ship. The Coast Guard has recorded 22 inspections since 1997, most recently in February 2024, along with 109 deficiencies and 6 operational controls.
Records from 1997 to 2024. Most recent: inspection, 6 February 2024.
- Built
- 1977
- Last inspected
- 6 February 2024
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 109 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7612280 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
H9CU
450646
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-450646
Inspections, by type
…with no type recorded15
Years with a record
8 calendar years (1997–2024)
The 22 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it1773 - Convention (Subpart B), Gross Ton
995 - Convention (Subpart B), Net Ton
2384 - Dead Weight, Ton
995 - Convention (Subpart B), Net Ton
2384 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 22
6 February 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7861703
29 February 2004
Re-Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2015150
28 February 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2054352
27 February 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2014667
6 October 2003
Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1922017
8 September 2003
Deficiency Check
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1899750
17 June 2003
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1812888
11 September 2002
Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1674171
16 August 2002
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1662236
4 April 2002
Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1600894
30 October 2001
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 294973
19 October 2001
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 294849
28 September 2001
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 294227
14 May 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 428818
12 March 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 426385
27 October 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 210743
27 October 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 767731
10 February 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 412700
8 January 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 411602
4 March 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 401218
3 January 1997
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 399122
1 January 1997
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 398998
Deficiency record · 109
Personnel › Certificates/Documents/Licenses
Issued 29 February 2004
Resolved
Vessel's master does not have a valid flag state endorsement for GMDSS. Master must provide proof of application. 95 STCW I/2 LEGACY COMPONENT DESC: STCW Endorsement
Personnel › Training
Issued 29 February 2004
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 29 February 2004
Resolved
CO2 cylinder inspection stickers indicate bottles are overdue for inspection. Have certified technician conduct inspection of all CO2 cylinders.
Construction/Loadline › Structures › Superstructure
Issued 29 February 2004
Resolved
Base of superstructure is wasted on all decks throughout vessel. Make permanent/proper repairs to all wastage along base of superstructure throughout the vessel.
Construction/Loadline › Structures › Deck Plating
Issued 29 February 2004
Resolved
Material covering all decks above the main deck does not allow for the inspection of the steel and structural integrity. Several locations on deck are in question. Remove material to allow for proper inspection of the decks condition and structural integrity.
Construction/Loadline › Structures › Superstructure
Issued 29 February 2004
Resolved
Penetrations coming from the interior of superstructure are wasted. Make permanent/proper repairs to penetration.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 29 February 2004
Resolved
Circuit breakers on main switchboard are fully exposed. Provide covers for all exposed breakers on main switchboard.
Construction/Loadline › Hull › Side Shell
Issued 29 February 2004
Resolved
Damage sustained in the aft port quarter of the vessel. Make proper/permanent repairs to the damaged area.
Construction/Loadline › Structures › Door
Issued 29 February 2004
Resolved
Hatch combing for the emergency escape IWO the steering compartment is holed and wasted. Make permanent/proper repairs to hatch combing.
Construction/Loadline › Structures › Deck Plating
Issued 29 February 2004
Resolved
Overhead is holed and wasted throughout engine room. Some places are temporary repairs (Bondo, sheet metal inserts). Make permanent/proper repairs to all wasted areas.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 29 February 2004
Resolved
Sewage line is wasted. Make permanent/proper repairs to sewage line.
Construction/Loadline › Structures › Deck Plating
Issued 29 February 2004
Resolved
Have flag state representative attest to the proper repair to overhead in several ares in the engine room, steering flat, and refrigerator room.
Construction/Loadline › Hull › Side Shell
Issued 29 February 2004
Resolved
Improper repair made to hull. "Diamond Plate" was used to repair area of hull. Make permanent/proper repairs to where "Diamond Plate" was used.
Construction/Loadline › Hull › Hull Plating
Issued 29 February 2004
Resolved
Cement patches on the deck and along the hull in space IWO of the engine room just aft of the cargo hold. Remove cement and make permanent/proper repairs to deck area and hull.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 29 February 2004
Resolved
Belt guard missing on motor in the port side of the engine room. Provide belt guard for motor.
Deck/Cargo › Ballast
Issued 29 February 2004
Resolved
Ballast piping is holed and wasted in engine room. Two other ballast lines are holed in aft area of cargo hold, both port and starboard. Make permanent/proper repairs (crop and renew) ballast piping in holed and wasted areas. LEGACY COMPONENT DESC: Piping
Fire Fighting › Fire Pumps
Issued 29 February 2004
Resolved
Fire/Ballast pump in engine room has wooden plug insert. Make permanent/proper repairs to pump. LEGACY COMPONENT DESC: Casing
Fire Fighting › Fire Main
Issued 6 October 2003
Resolved
Fire pump lacks adequate pressure due to holes in fire main piping (iaw SOLAS 74 Amended/II-2/22) LEGACY COMPONENT DESC: Pressure
Engineering › Steering Gear System
Issued 6 October 2003
Resolved
Vessel has a 16 degree deviation between bridge reading and actual reading at the rudder post. LEGACY COMPONENT DESC: Rudder Angle Indicator
Pollution Prevention/Response › Prevention Equipment
Issued 6 October 2003
Resolved
Starboard side toilet discharges directly overboard. LEGACY COMPONENT DESC: Sewage System Piping
Construction/Loadline › Markings
Issued 6 October 2003
Resolved
Permanently affix ICLL marking iaw ICLL certificate (iaw ICLL 73/78/Annex I/Reg. 4,5,7, and 8)
Documentation › Manuals/Policy Documentation
Issued 6 October 2003
Resolved
Cargo Securing Manual not approved by flag state.
Documentation › Logs/Records
Issued 6 October 2003
Resolved
Garbage Record Book not in use. Vessel must log all entries required by iaw MARPOL 73/78 /ANNEX V/9. LEGACY COMPONENT DESC: Garbage Recordkeeping
Documentation › Logs/Records
Issued 6 October 2003
Resolved
No Ballast Water Management Plan or records onboard iaw 33 CFR 151.2040 and 151.2045. LEGACY COMPONENT DESC: Ballast Water Reporting Form
Pollution Prevention/Response › Prevention Equipment
Issued 6 October 2003
Resolved
Make permanent and proper repairs to port side fuel vent containments iaw MARPOL 73/78/Annex I/Reg. 9. LEGACY COMPONENT DESC: Fixed Containment
Navigation › Piloting/Steering
Issued 6 October 2003
Resolved
U.S. Coast Pilot [name withheld], Tidal Current Table, are not onboard or not up to date iaw 33 CFR 164.33.
Accommodation/Occupational Safety › Refrigeration (air conditioning)
Issued 6 October 2003
Resolved
Overhead in store room not weathertight iwo refrigeration system.
Construction/Loadline › Penetrations
Issued 6 October 2003
Resolved
Quick release valves not properly sealed iwo superstructure.
Lifesaving › Rescue Boat › Propulsion Starting System
Issued 6 October 2003
Resolved
Exposed hazard on rescue boat engine iwo of port and stbd side rescue boats. Engine has exposed rotating chain. Provide guard for exposed chain hazards.
Personnel › Manning/Qualifications
Issued 9 June 2003
Resolved
Vessel not manned IAW with safe manning document. Missing one chief mate and one able seaman. LEGACY COMPONENT DESC: Minimum Safe Manning
Fire Fighting › Fire Main
Issued 9 June 2003
Resolved
Firemain piping ruptured. Correct to the satisfaction of the certificate issuing authority prior to departure from port. No cargo operations authorized until repairs are made. LEGACY COMPONENT DESC: Condition
Personnel › Certificates/Documents/Licenses
Issued 11 September 2002
Resolved
Provide orginal STCW License/Documents for the 1 A/B (Watters) and 1 O/S Prior to sailing. LEGACY COMPONENT DESC: STCW Endorsement
Construction/Loadline › Structures
Issued 11 September 2002
Resolved
Properly repair the wasted superstructure on the aft boat deck below the door to the storage locker for the firemen's outfit. Repair to be completed to the satisfaction of th attening flag surveyor prior to 01OCT02 LEGACY COMPONENT DESC: Superstructure
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 11 September 2002
Resolved
Conduct required servicing for all liferafts and fire fighting extinguishers. Provide a copy of serviciing certificate and to the USCG prior to sailing. LEGACY COMPONENT DESC: Service
Lifesaving › Lifeboat
Issued 11 September 2002
Resolved
Provide proper lauching instructions for the liferafts. Lauching instruction must be for the liferaft currently on board the vessel. Complete prior to 01OCT02 to satisfaction of the USCG
Lifesaving › Lifeboat
Issued 11 September 2002
Resolved
Properly repair cracks in both lifeboats to the staisfaction of Flag prior to sailing. LEGACY COMPONENT DESC: Hull
Construction/Loadline › Penetrations
Issued 11 September 2002
Resolved
Properly repair the wasted gasket retainer for the stbd emergency escape trunk hatch cover leading to the engine room prior to 01OCT02 to the stisfaction of USCG. LEGACY COMPONENT DESC: Gasket
Pollution Prevention/Response › Prevention Equipment
Issued 11 September 2002
Resolved
Properly repair wasted containment around #2 stbd fuel oil vent prior to 01OCT02. LEGACY COMPONENT DESC: Coamings
Deck/Cargo › Mooring/Anchoring
Issued 11 September 2002
Resolved
Properly repair/replace the anchor stop for the stbd anchor to the satisfaction of the attending class surveyor prior to 01OCT02. LEGACY COMPONENT DESC: Winch
Deck/Cargo › Holds/Tanks
Issued 11 September 2002
Resolved
Conduct an internal structural exam of #5 port double bottom ballast tank and make proper repairs to the holed tank top to the satisfaction of the attending flag administration surveyor.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 11 September 2002
Resolved
Replace Turbo charger canisters for #1 and #2 ship generators to the satisfaction of the attending USCG Marine Inspector. LEGACY COMPONENT DESC: Turbocharger
Engineering › Diesel Engine (propulsion-electric)
Issued 11 September 2002
Resolved
Make permanent and proper repairs to lube oil leak on forward seal of #1 generator to satisfaction of the atending class surveyor.
Pollution Prevention/Response › Prevention Equipment
Issued 11 September 2002
Resolved
Make permanent and proper repairs to oily water separator and prove proper operation to USCG. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Engineering › Sea-water System (primary cooling)
Issued 11 September 2002
Resolved
Replace valve on raw water main cooling system (hole in valve just before heat exchanger) to the satisfaction of the attending USCG marine inspector. LEGACY COMPONENT DESC: Valve
Engineering › Bilge Water Management System
Issued 11 September 2002
Resolved
Properly label emergency suction valve in Engine Room to the satisfaction of the attending USCG inspector. LEGACY COMPONENT DESC: Valve
Documentation › Certificates/Documents
Issued 11 September 2002
Resolved
Provide a valid IOPP certificate and Form A. IOPP certificate has incorrect IMO number and Form A lists incorrect equipment under section w.e. LEGACY COMPONENT DESC: IOPP Certificate
Documentation › Certificates/Documents
Issued 11 September 2002
Resolved
Provide copies of ISM external audit under which company DOC and vessel SMC were issued.
Construction/Loadline › Hull
Issued 11 September 2002
Resolved
Properly install wheelhouse window in way of A/C unit such that the window is weathertight to the satisfaction of the flag surveyor.
Lifesaving › Launching Appliances
Issued 11 September 2002
Resolved
Replace the aft gripe hardware for the Port Lifeboat to the satisfaction of the attending Flag surveyor. LEGACY COMPONENT DESC: Padeye
Lifesaving › Launching Appliances
Issued 11 September 2002
Resolved
Properly repair or replace the tiller for the Port Lifeboat to the satisfaction of the attending Flag surveyor.
Documentation › Safety Management System
Issued 11 September 2002
Resolved
ISM Certs are not valid. The company does not meet the criteria for interim certs as provided for in chap 10 of SOLAS. By order of the COTP of Miami. The vessel, once released must depart US waters and provide proper full term ISM certs prior to next US port. LEGACY COMPONENT DESC: Company Responsibility/Authority Documentation
Lifesaving › Lifeboat Equipment
Issued 11 September 2002
Resolved
Lifeboat bowsing tackle and tricing pennants missing. Provide new hardware and conduct abandon ship drill to satisfaction of USCG prior to departing port of MIAMI.
Documentation
Issued 30 October 2001
Resolved
Master and Cheif Officer had fraudulent Panamanian licenses. Second and Third Engineer was not properly licensed.
Navigation
Issued 30 October 2001
Resolved
Missing local charts of the Calcaiseu Ship Channel.
Lifesaving
Issued 19 October 2001
Resolved
Provide proper ring buoy for bridge wing quick release, as per SOLAS 74/reg31.
Lifesaving
Issued 28 September 2001
Resolved
Identify all electrical labels and piping labels in english/spanish,_x001C_ correct prior to next U.S. voyage.
Engineering
Issued 28 September 2001
Resolved
Demonstrate operation of fuel oil transfer pump emergency shut down, as per33 CFR 155.450, prior to any fuel transfer in U.S. waters.
Fire Fighting
Issued 28 September 2001
Resolved
Replace lifebuoy lifeline, starboard side aft, with proper buoyant lifeline, as per SOLAS (amd) III-31/4.3, prior to departure.
Fire Fighting
Issued 28 September 2001
Resolved
Fire control plan inaccurate, need to be updated as per SOLAS (amd) II- 2/20.1. Prior to next U.S. voyage.
Fire Fighting
Issued 28 September 2001
Resolved
Firemans outfits (SCBA) stored in one location, not seperated as per SOLAS 74 (amd) II-3/17.4. Correct prior to departure.
Deck/Cargo
Issued 28 September 2001
Resolved
Renew wasted coaming for forepeak hatch, provide class report. Correct prior to departure.
Deck/Cargo
Issued 28 September 2001
Resolved
Repair wasted coaming for starboard forward cargo hold escape, provide class report. Correct prior to departure.
Construction/Loadline
Issued 28 September 2001
Resolved
Provide class society report as to the structual integrity of main deck starboard midship, in way of previous transverse fracture of longitudinal strength doubler and internal main deck fractures. Prior to departure.
Construction/Loadline
Issued 28 September 2001
Resolved
Provide class society report identifying wastage of main deck, forward of cargo hold hatch #1 (gauge report), prior to departure.
Construction/Loadline
Issued 28 September 2001
Resolved
Provide class report for ballast tank internal exam performed in Jacksonville, Fl in March, prior to departure.
Construction/Loadline
Issued 28 September 2001
Resolved
Make starboard forward door to hold watertight, prior to departure.
Accommodation/Occupational Safety
Issued 28 September 2001
Resolved
Demonstrate ventilation covers throughout the vessel are operable, prior todeparture.
Documentation
Issued 28 September 2001
Resolved
Provide class report for the temporary patch on machinery space emergency bilge piping, correct prior to departure.
Deck/Cargo
Issued 28 September 2001
Resolved
Provide positive closing, oil containment plugs, for deck coaming. Correctprior to fuel transfer in the U.S.
Electrical
Issued 28 September 2001
Resolved
Replace missing knobs and switches on main switch board, correct prior to departure.
Documentation
Issued 28 September 2001
Resolved
Provide class society survey reports, prior to departure.
Fire Fighting
Issued 28 September 2001
Resolved
Provide second fire pump in seperate space meeting SOLAS 60 Chapter II, regulation 65, prior to departure.
Lifesaving
Issued 28 September 2001
Resolved
Provide class report for acceptance of paint locker location in storage aftof machinery control room, prior to departure.
Deck/Cargo
Issued 28 September 2001
Resolved
Provide class society report for several wasted frames in cargo hold port aft lower section and renewal schedule, prior to departure.
Construction/Loadline
Issued 28 September 2001
Resolved
Provide class society report for renewal of 5 consecutive distorted gussetsport side overhead of forepeak, prior to departure.
Electrical
Issued 28 September 2001
Resolved
Provide class determination of additional emergency light at top of engine room, stairwell and evalute emergency lighting at each escape route and exit. Provide prior to departure.
Fire Fighting
Issued 28 September 2001
Resolved
Identify the required fire rated door for stairwell at officers deck and provide the door, prior to departure.
Navigation
Issued 28 September 2001
Resolved
Provide navigation chart 11417, prior to departure.
Fire Fighting
Issued 28 September 2001
Resolved
Provide fire hose station and combination nozzle port side aft lower machinery space, prior to departure.
Fire Fighting
Issued 28 September 2001
Resolved
Provide combination fire nozzle for machinery space upper level, prior to departure.
Lifesaving
Issued 12 March 1999
Resolved
Repair light on stbd smoke float on lifebuoy on bridge deck.
Documentation
Issued 12 March 1999
Resolved
Provide manual for the maintenance and operation of all firefighting equipment.
Lifesaving
Issued 12 March 1999
Resolved
Provide (2) required liferafts as required by SOLAS Safety Certificate and fax servicing report to the Marine Safety Office.
Lifesaving
Issued 12 March 1999
Resolved
Make port side lifebuoy on bridge capable of quick release.
Documentation
Issued 12 March 1999
Resolved
Provide Russian translation for SOLAS Training Manual.
Navigation
Issued 12 March 1999
Resolved
Provide proper operation of main and auxiliary steering gear.
Lifesaving
Issued 12 March 1999
Resolved
Provide line throwing apparatus.
Lifesaving
Issued 12 March 1999
Resolved
Replace/renew batteries for both port and stbd radar transponders.
Navigation
Issued 12 March 1999
Resolved
Provide Class Report (BV) addressing when vessel will be compliant with GMDSS requirements.
Navigation
Issued 8 January 1998
Resolved
PROVIDE LOCAL MIAMI CHART NUMBER 11468.
Fire Fighting
Issued 8 January 1998
Resolved
PROVIDE GASKET, BOLTS AND NUTS FOR INTERNATIONAL SHORE CONNECTION.
Fire Fighting
Issued 8 January 1998
Resolved
PROVIDE EMERGENCY FIRE PUMP AS REQUIRED BY SOLAS 60 CHAPTER II REGULATION 65.
Accommodation/Occupational Safety
Issued 1 January 1997
Resolved
ENGINE ROOM EMERGENCY ESCAPE EXIT BLOCKED WITH 5 GALLON PLASTIC DRUMS.
Electrical
Issued 1 January 1997
Resolved
MAIN ELECTRICAL SWITCH BOARDS IN ENGINE ROOM CONTOL STATION DO NOT HAVE REAR PANEL COVERS. THIS EXPOSES ANYONE BEHIND THE SWITCH BOARD TO ALL THE MAIN BREAKERS AND POWER BARS.
Electrical
Issued 1 January 1997
Resolved
PORT GENERATOR SET FUEL LINES IN CONTACT WITH EXAHUST MANIFOLD.
Engineering
Issued 1 January 1997
Resolved
MAIN ENGINE COOLING WATER PUMP LEAKING EXCESSIVELY.
Documentation
Issued 1 January 1997
Resolved
VESSEL'S SAFE MANNING CERTIFICATE IS A FAXED COPY. VESSEL HAS NOT YET RECEIVED THE ORIGINAL.
Navigation
Issued 1 January 1997
Resolved
VESSEL DID NOT HAVE A MANEUVERING FACT SHEET.
Engineering
Issued 1 January 1997
Resolved
VESSEL DOES NOT HAVE FLAME SCREENS ON ANY OF ITS FUEL OIL, BILGE SLOPS, OR LUBE OIL TANK VENTS. _x001C_ SEE MSM VOL II, CH 19, SECTION 19.D.7 FOR APPLICATION
Construction/Loadline
Issued 1 January 1997
Resolved
VESSELS SPARE ANCHOR LOCKER WASTED TO THE POINT THAT SEA WATER THAT ENTERS THE LOCKER LEAKS THROUGH THE DECK INTO THE ENGINE ROOM. OBSERVED AT LEAST TWO AREA WHERE SALT WATER WAS ENTERING THE ENGINE ROOM THROUGH THE OVERHEADAND FALLING ONTO THE PORT GENERATOR SET AND STARBOARD WALK WAY.
Navigation
Issued 1 January 1997
Resolved
VESSELS MAGNETIC COMPASS ILLUMINATION NOT WORKING.
Navigation
Issued 1 January 1997
Resolved
VESSEL DID NOT HAVE EMERGENCY STEERING GEAR INSTRUCTIONS POSTED ON THE BRIDGE.
Lifesaving
Issued 1 January 1997
Resolved
LIFEJACKET LIGHT EXPIRED ON 31JUN96. LIFEJACKET RETROREFLECTIVE TAPE FADEDAND WORN.
Electrical
Issued 1 January 1997
Resolved
PORT GENERATOR SET COOLING WATER DISCHARGE PIPE HAS A RUBBER COUPLING. CHIEF ENGINEER SAID THE RUBBER COUPLING WAS INSTALLED TO REDUCE VIBRATION.
Fire Fighting
Issued 1 January 1997
Resolved
FIRE HOSES HAVE SMALL LEAKS AND FIRE HOSE NOZZEL SPRAY ADJUSTING TIPS ARE CORRODED AND WILL NOT TURN.
Fire Fighting
Issued 1 January 1997
Resolved
FIRE CONTROL PLAN LEGEND NOT TRANSLATED TO ENGLISH OR FRENCH._x001C_ SOLAS CH II, REG 20_x001C_ _x001C_ _x001C_
Lifesaving
Issued 1 January 1997
Resolved
FIRE DRILL AND ABANDON SHIP DRILL NOT PERFOORMED TO THE SATISFACTION OF THEMARINE INSPECTORS. CREW DID NOT KNOW HOW TO USE SCBA'S SOME OF THE SCBA'S WERE STILL IN THE ORIGINAL SEALED PLATIC BAG. CREW WAS UNFAMILUR WITH LOWERING THE LIFE BOAT. IT TOOK 45 MINUTES TO GET THE BOAT IN THE WATER.
Documentation
Issued 1 January 1997
Resolved
VESSEL DOES NOT HAVE OIL TRANSFER PROCEDURES.
Engineering
Issued 1 January 1997
Resolved
VESSEL DID NOT HAVE ANY FIXED CONTAINERS OR ENCLOSED DECK AREAS FOR ANY OF ITS FUEL OIL, LUBE OIL, AND BILGE SLOPS TANK VENTS AND FILL PIPES. VESSEL IS 1773 GT BUILT IN 1977 AND IS REQUIRED TO PROVIDE 1 BARREL (42 GALLON) SMALL DISCHARGE CONTAINMENT AROUND EACH VENT MENTIONED ABOVE.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.