MAURY USCG vessel records Sign in
← All vessels

CROWN GARNET

CROWN GARNET is a 1996 freight ship. The Coast Guard has recorded 44 inspections since 1997, most recently in November 2022, along with 29 deficiencies and 8 operational controls.

Records from 1997 to 2022. Most recent: inspection, 22 November 2022.

Built
1996
Last inspected
22 November 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9128049 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
450647
Flag
BAHAMAS, THE
—
Maury page id
psix-450647

Inspections, by type

…with no type recorded27
Years with a record 16 calendar years (1997–2022)
The 44 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it10519 - Convention (Subpart B), Gross Ton
5406 - Convention (Subpart B), Net Ton
10332 - Dead Weight, Metric Ton
16522 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 44

22 November 2022 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7598289
17 November 2022 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7596293
3 February 2022 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7390125
2 February 2022 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7389403
3 February 2020 PSC A
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6901615
1 August 2011 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4101836
17 January 2011 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3926477
17 January 2011 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3927734
18 January 2010 Deficiency Check · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3665553
15 April 2008 Loadline Exam · PII Safety Exam · ISPS II Exam · Ballast Water Examination · ILO-147 Exam · MARPOL Annex I Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3184396
11 June 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2958086
28 May 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2943842
1 May 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2919772
19 April 2007 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2910761
8 February 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2869011
14 March 2006 PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2600848
22 November 2005 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2539252
22 November 2005 Random ISPS/MTSA/PSC
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2539255
4 November 2005 ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2528646
21 September 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2497735
21 September 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2498579
20 September 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2497484
24 February 2005 Re-Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2298516
7 July 2004 ISPS II Exam
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2124566
26 May 2004 ISPS II Exam · MARPOL Annex I Examination · Annual Inspection · Ballast Water Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1940423
11 April 2003 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1772065
4 March 2003 Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1746641
17 July 2002 MARPOL Annex I Examination · Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1645823
6 December 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 296107
7 September 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 293611
9 July 2001 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1067415
8 June 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 290863
1 May 2000 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 277907
9 September 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 729795
31 August 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 24104
31 August 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 432390
30 April 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 428192
20 July 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 418309
6 July 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 417614
16 January 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 411994
24 July 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 406040
14 May 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 403717
29 January 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 399996
10 January 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 399268

Deficiency record · 29

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 February 2022 Resolved
74 SOLAS (04) II/1/45.5.5 Cables and wiring shall be installed and supported in such a manner as to avoid chaffing or other damage. PSCO observed excessive wastage along deck conduit line and cable boxes. Multiple holes, cracks and temporary repairs allowed for water ingress.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 April 2022
Resolution: Class has approved proper repairs of conduit line. USCG has reviewed RMS Class report. No further action required.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 3 February 2020 Resolved
74 SOLAS (97) III/44.2.2 - Every totally enclosed lifeboat shall be provided with a rigid watertight enclosure which completely encloses the lifeboat. The enclosure shall be so arranged that: access to the lifeboat is provided by the hatches which can be closed to make the lifeboat watertight. PSCO observed three one inch cracks and bowing on hatch collar of starboard lifeboat. A fire hose pressure test proved the lifeboat to not be watertight.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2020
Resolution: ABS Work Order: 4120543. The three (3) cracks of one (1) inch each on the starboard lifeboat and associated hatch collar bowing were repaired by an external specialist recognized by ABS; the hatch was pressure tested with a fire hose, all SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 3 February 2020 Resolved
74 SOLAS (97) III/41.8.9 - Except where otherise stated, the normal equipment of every lifeboat shall consist of: watertight receptacles containing a total of 3 liter of fresh water for each person the lifeboat is permitted to accomodate. PSCO observed one 1 litter package of water leaking. Vessel does not have any spare, SOLAS approved packages of fresh water.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2020
Resolution: ABS Work Order 4120543. The vessel had procured spare SOLAS approved fresh water packages such that the full complement of personnel permitted by the lifeboat are accommodated with the required amount of fresh water.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 February 2020 Resolved
74 SOLAS (97) II - 2/47.2 - Doors required to be self-closing shall not be fitted with hold-back doors. PSCO observed 03 class "a" doors with hold-back devices in place.
Action required: 10 - Deficiency Rectified
Resolved 3 February 2020
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 18 January 2010 Resolved
Toilet in hospital space inoperable.
Due 18 January 2010
Resolved 18 January 2010
Resolution: Toilet is operable.
Electrical › Electric Generation Source (service) › Panelboard
Issued 18 January 2010 Resolved
Area behind main switchboard shall be free of storage.
Due 18 January 2010
Resolved 18 January 2010
Resolution: Area has been cleared of storage.
Fire Fighting › Means of Escape › Doorways
Issued 18 January 2010 Resolved
Emergency escape door in engine room not closing completely.
Due 18 January 2010
Resolved 18 January 2010
Resolution: Emergency escape door has been repaired.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 19 April 2007 Resolved
Fire door leading from the Machinery room to the main deck is not capable of self closing. Adjust this and any other fire door fitted in boundary bulkheads of machinary spaces of category A to self- close
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 April 2007
Resolved 11 June 2007
Resolution: Fire door leading from machinery room to the main deck has been overhauled and is now working satisfactory. Other fire doors inspected and found in good working order.
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 21 September 2005 Resolved
21Sep05: During vsl departure from San Juan, vsl reported Main Engine Governor System failure.
Action required: 705 - Other - as specified
Due 21 September 2005
Resolved 21 September 2005
Resolution: 21Sep05: Vsl granted permission to depart with temporary repairs and on the condition that permanent repairs would be made at NPOC. 28Sep05: Rcvd Class report attesting to the permanent repairs of M/E Governor system.
Engineering › Steering Gear System › Power Unit
Issued 21 September 2005 Resolved
21Sep05: During vsl departure from San Juan, vsl reported loss of main steering control at wheel house.
Action required: 705 - Other - as specified
Due 21 September 2005
Resolved 28 September 2005
Resolution: 21Sep05: Vsl granted permission to depart with temporary repairs and on the condition that permanent repairs would be made at NPOC. 28Sep05: Rcvd Class report attesting to the permanent repairs of main Steering system.
Navigation › Piloting/Steering › Gyro Compass
Issued 20 September 2005 Resolved
Gyro Compass deemed inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 September 2005
Resolved 21 September 2005
Resolution: Received certified tech report from CRT Communications stating that gyro over heated, they exchanged fluid and mercury plus insulator. Gyro n good working condition.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 4 March 2003 Resolved
Renew/replace brackets at fire station #18 prior to 18 March 2003. LEGACY COMPONENT DESC: Mounting Bracket
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 March 2003
Resolved 11 April 2003
Resolution: Brackets at fire station #18 were renewed/replaced.
Navigation › Piloting/Steering
Issued 4 March 2003 Resolved
Provide copy of Inland Rules of the Road as per 33 CFR 164.33 prior to next U.S. port. LEGACY COMPONENT DESC: Inland Navigation Rules
Action required: 15 - Rectify deficiencies by next port
Resolved 11 April 2003
Resolution: Inland Rules of the Road have been provided.
Construction/Loadline
Issued 7 September 2001 Resolved
FIX/REPLACE WATER TIGHT DOOR TO ACCESS SHIP,S HOSPITAL. THE DOOR IS WARPED.PROVIDE CLASS REPORT TO LOCAL [name withheld] JUAN.
Condition: Unknown
Due 6 December 2001
Resolved 6 December 2001
Fire Fighting
Issued 7 September 2001 Resolved
PROVIDE CLASS REPORT TO LOCAL [name withheld] JUAN, STATING THAT THE CREW CAN PERFORM THE REQUIRED INSPECTION AND TEST TO FIRE EXTINGUISHERS INCLUDING THE ANNUAL INSPECTION.
Condition: Unknown
Due 6 December 2001
Resolved 6 December 2001
Fire Fighting
Issued 8 June 2001 Resolved
Repair latches on fire door in engine room. Provide signed statement and class report to local OCMI prior to 08JUL01.
Condition: Unknown
Due 9 July 2001
Resolved 9 July 2001
Construction/Loadline
Issued 8 June 2001 Resolved
Provide Class Report of damage in way of frame 135(forty feet forward of loadline, starboard side). Provide report to OCMI before 08JUL01.
Condition: Unknown
Due 9 July 2001
Resolved 9 July 2001
Fire Fighting
Issued 8 June 2001 Resolved
Stencil emergency instructions and location for paint locker sprinkler_x001C_ valve and remote shut down for emergancy generator fuel tank outside of space. Provide signed statement and class report of repairs to local OCMI by 08JUL01.
Condition: Unknown
Due 9 July 2001
Resolved 9 July 2001
Navigation
Issued 31 August 1999 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 31 August 1999
Resolved 1 September 1999
Engineering
Issued 31 August 1999 Resolved
PROPULSION MACHINERY NOT FULLY CONTROLLABLE FROM NAVIGATION BRIDGE. (SOLAS 74 AMENDED II-1-49) REPAIR TO "SAT OF CLASS" PRIOR TO NEXT U.S PORT. VSL'SAUTOMATED COMPUTER FOR EXECUTING BRIDGE COMMANDS "UNRELIABLE". VSL USING 24MANNING OF ENG ROOM TO EXECUTE BRIDGE COMMANDS MANUALLY.
Condition: Unknown
Due 4 September 1999
Resolved 10 September 1999
Engineering
Issued 16 January 1998 Resolved
INSTALL PERMANENT PERSONEL GUARD FOR MAIN ENGINE TURNING GEAR. TO SATISFACTION OF CLASS SOCIETY. PROVIDE LOCAL COAST GUARD WITH SATISFACTORYCLASS SOCIETY SURVEYOR'S REPORT.
Condition: Unknown
Due 20 July 1998
Resolved 20 July 1998
Lifesaving
Issued 16 January 1998 Resolved
PLACE NONCONDUCTIVE MATTING IN FRONT OF EMERGENCY GENERATOR SWITCHBOARDS. TO SATISFACTION OF CLASS SOCIETY. PROVIDE LOCAL COAST GUARD WITH SATISFACTORY SURVEYORS REPORT.
Condition: Unknown
Due 20 July 1998
Resolved 20 July 1998
Electrical
Issued 14 May 1997 Resolved
VESSEL MUST PROVIDE COVERS ON LIGHT FIXTURES IN CREW STATE ROOMS AS REQUIRED BY ILO 147.
Condition: Unknown
Due 24 July 1997
Resolved 24 July 1997
Electrical
Issued 29 January 1997 Resolved
VESSEL MUST PROVIDE COVERS ON LIGHT FIXTURES IN CREW STATE ROOMS AS REQUIRED BY ILO 147.
Condition: Unknown
Due 15 May 1997
Resolved 2 April 1997
Fire Fighting
Issued 10 January 1997 Resolved
VESSEL MUST MARK ALL VENTILATION HEADS WITH SPACE SUPPLIED AND HANDLE DIRECTION OF CLOSURE AS REQUIRED BY SOLAS 74 II. CORRECT PRIOR TO NEXT U.S PORT.
Condition: Unknown
Due 3 February 1997
Resolved 3 February 1997
Fire Fighting
Issued 10 January 1997 Resolved
VESSEL MUST PROVIDE A FIREPROOF TAG LINE BY ALL FIRE SUITS AS REQUIRED BY SOLAS 74. CORRECT PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 3 February 1997
Resolved 3 February 1997
Electrical
Issued 10 January 1997 Resolved
VESSEL MUST PROVIDE COVERS ON LIGHT FIXTURES IN CREW STATE ROOMS AS REQUIRED BY ILO 147. CORRECT PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 3 February 1997
Resolved 3 February 1997
Unknown
Issued 10 January 1997 Resolved
VESSEL INSTALL CHAFING GEAR OVER THE FIRE MAIN IN WAY OF THE ACCOMADATION LADDER WIRES, SOLAS 74 II-1/43. CORRECT PRIOR TO ENTRY INTO NEXT U.S. PORT.
Condition: Unknown
Due 3 February 1997
Resolved 3 February 1997
Electrical
Issued 10 January 1997 Resolved
VESSEL MUST PROVE PROPER OPERATION OF EMERGENCY GENERATOR AS REQUIRED BY SOLAS 74 II. CORRECT PRIOR TO ENTRY INTO NEXT U.S. PORT.
Condition: Unknown
Due 3 February 1997
Resolved 3 February 1997

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.