Records from 1996 to 2024. Most recent: inspection, 1 October 2024.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 30
1 October 2024
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8012332
3 October 2007
Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3070634
5 July 2007
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2984324
8 September 2006
In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2773180
23 June 2006
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2688946
21 March 2006
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2606617
28 January 2006
Deficiency Check · Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2575079
26 September 2005
Damage Survey · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2500601
1 July 2005
Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2410380
1 July 2005
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2411161
8 April 2004
Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2013046
8 April 2004
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2043739
27 February 2004
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2013039
21 May 2003
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1798033
14 May 2003
Simplified Stability Test
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1798343
20 February 2003
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1747489
20 December 2002
Drydock Extension
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1721584
7 March 2002
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1491913
6 June 2001
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1470320
30 June 2000
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1440350
10 May 1999
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1106844
3 May 1999
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1131570
10 March 1999
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1372540
1 March 1999
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1369105
12 January 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 696825
11 January 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1390900
10 June 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1451204
15 January 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1101630
24 December 1996
Hull Examination · Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1413094
11 June 1996
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1093972
Communications › Alarms/Indicators › General Alarm
Issued 23 June 2006
Resolved
Provide operational PA system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 October 2013
Resolution: Vessel has been out of service since 2006. Closing all open deficiencies due to administrative procedures.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 June 2006
Resolved
Stencil lifering with vessel name and repair inoperative light.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 October 2013
Resolution: Vessel has been out of service since 2006. Closing all open deficiencies due to administrative procedures.
Communications › Radio Communications › EPIRB
Issued 23 June 2006
Resolved
Renew EPIRB hydrostatic release and battery.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 October 2013
Resolution: Vessel has been out of service since 2006. Closing all open deficiencies due to administrative procedures.
Lifesaving › Lifefloat › Approval
Issued 23 June 2006
Resolved
Provice 4 new 22 person lifefloats or service current ones and provide missing oars and lights.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 October 2013
Resolution: Vessel has been out of service since 2006. Closing all open deficiencies due to administrative procedures.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 23 June 2006
Resolved
Provide lifesaving equipment log.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 October 2013
Resolution: Vessel has been out of service since 2006. Closing all open deficiencies due to administrative procedures.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 June 2006
Resolved
Provide adecuate first aid kit. (Current one too small).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 October 2013
Resolution: Vessel has been out of service since 2006. Closing all open deficiencies due to administrative procedures.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 23 June 2006
Resolved
Clean and install retroreflective tape on all faded lifejackets and segregate child lifejackets. And repair all lifejacket door hasps.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 October 2013
Resolution: Vessel has been out of service since 2006. Closing all open deficiencies due to administrative procedures.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 23 June 2006
Resolved
Repair both main engines exhaust leaks (currently leaking water on top of 24 v battery boxes)
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 October 2013
Resolution: Vessel has been out of service since 2006. Closing all open deficiencies due to administrative procedures.
Construction/Loadline › Hull › Bottom Plating
Issued 28 January 2006
Resolved
Transom extension deck; make permanent repairs to ensure watertight integrity. Submitt repair proposal.
Action required: 705 - Other - as specified
Resolved 3 March 2006
Construction/Loadline › Structures › Deck Plating
Issued 28 January 2006
Resolved
Passenger deck; make permanent repairs to ensure water does not penetrate to below deck. Submitt repair proposal. (small holes found on passenger deck above stbd engine room)
Action required: 705 - Other - as specified
Resolved 3 March 2006
Construction/Loadline › Structures › Machinery Space Opening
Issued 28 January 2006
Resolved
Renew all watertight hatch deck seals.
Action required: 705 - Other - as specified
Resolved 20 March 2006
Resolution: Vessel rep replaced sealing
Construction/Loadline › Hull › Hull Plating
Issued 28 January 2006
Resolved
Crop and renew, submitt repair proposal for marked hole, inner stbd aft hull.
Action required: 705 - Other - as specified
Resolved 3 March 2006
Construction/Loadline › Hull › Bottom Plating
Issued 28 January 2006
Resolved
Crop and renew, submitt repair proposal for bow section, underneath deck between port and stbd hull.
Action required: 705 - Other - as specified
Resolved 3 March 2006
Construction/Loadline › Penetrations › Pipe Flange
Issued 28 January 2006
Resolved
Renew the following bilge overboard discharge piping/through-hull fittings. Stbd eng room 02 each, Port eng room fwd 01 each, #3 void stbd side 01 each, stbd steering room 01 each.
Action required: 705 - Other - as specified
Resolved 3 March 2006
Engineering › Bilge Water Management System › Pump
Issued 28 January 2006
Resolved
Renew bilge suction wiring in port and stbd steering gear rooms.
Action required: 705 - Other - as specified
Resolved 20 March 2006
Resolution: Vessel rep replaced all wiring and added new bilge pumps
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 26 September 2005
Resolved
Provide missing exhaust insulation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 October 2005
Fire Fighting › Fire Pumps › Pressure
Issued 1 July 2005
Resolved
Repair fire main and test in the presence of a USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 July 2005
Electrical › Electrical Distribution System (service) › Switchboard
Issued 1 July 2005
Resolved
Repair broken cables in switchboard and proof proper operation of bilge pumps alarms to attending USCG Marine Inspector
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 July 2005
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 1 July 2005
Resolved
Repair buoyant apparatus strobe light and proof proper operation to USCG Marine Inspector.
Due 11 July 2005
Resolved 2 July 2005
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 1 July 2005
Resolved
Provide Coast Pilot/ tides, lights handbook to attending USCG Marine inspector.
Due 11 July 2005
Resolved 14 October 2005
Navigation › Piloting/Steering
Issued 21 May 2003
Resolved
Repair compass light prior to night operations LEGACY COMPONENT DESC: Magnetic Compass
Action required: 705 - Other - as specified
Resolved 23 May 2003
Lifesaving › Lifejacket/PFD (General)
Issued 21 May 2003
Resolved
Properly stow and lable stowage of all life jackets. Adult and Child life jackets must be stowed and marked separetly LEGACY COMPONENT DESC: Storage
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2003
Lifesaving › Lifeboat Equipment
Issued 21 May 2003
Resolved
Mark all life float oars with the vessels name. LEGACY COMPONENT DESC: Oar
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2003
Lifesaving › Buoyant Apparatus
Issued 21 May 2003
Resolved
Replace the 12 and 22 person lifefloats stowed on the starboard side of the pilot house.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2003
Resolved 23 May 2003
Lifesaving › Lifejacket/PFD (General)
Issued 21 May 2003
Resolved
Post life jacket donning procedures on upper deck. LEGACY COMPONENT DESC: Storage
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2003
Communications › Internal Communications System
Issued 21 May 2003
Resolved
Repair vessels public address system LEGACY COMPONENT DESC: Public Adress system
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2003
Engineering › Bilge Water Management System
Issued 21 May 2003
Resolved
Demonstrate proper operation of vessels bilge system LEGACY COMPONENT DESC: Eductor
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2003
Engineering › Bilge Water Management System
Issued 21 May 2003
Resolved
Label all suction valve lines for each compartment and post operation instructions. LEGACY COMPONENT DESC: Manifold
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2003
Resolved 23 May 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 21 May 2003
Resolved
Stow and label the compartment of the location of the First Aid Kit LEGACY COMPONENT DESC: Labeling
Action required: 705 - Other - as specified
Due 30 May 2003
Resolved 23 May 2003
Engineering
Issued 21 May 2003
Resolved
Remove excess cables and wire runs from engine space.
Due 6 June 2003
Resolved 8 April 2004
Resolution: Excess cables and wire runs were removed from engine space.
Electrical › Lighting (service)
Issued 20 December 2002
Resolved
Mount or remove engine space light fixutres that are hanging from overhead in both port and starbard engine space. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 20 January 2003
Resolved 22 May 2003
Engineering › Bilge Water Management System
Issued 20 December 2002
Resolved
Permanently mount both port and starboard aft engine room bilge pumps. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Due 20 January 2003
Resolved 22 May 2003
Electrical › Electric Supply System (service)
Issued 20 December 2002
Resolved
Install battery covers on batteries located aft of the engines in both port and starboard hull. LEGACY COMPONENT DESC: Battery Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2004
Resolution: Battery covers were install.
Electrical › Electrical Distribution System (service)
Issued 20 December 2002
Resolved
Replace all plastic wire ties throughout vessel with metal wire ties and hangers. LEGACY COMPONENT DESC: Wiring
Due 6 June 2003
Resolved 8 April 2004
Resolution: Plastic wire ties were replaced with metal wire ties.
Construction/Loadline › Penetrations
Issued 20 December 2002
Resolved
Inspect all water tight bulkhead pipe penetrations and weld those that do not have continues welds, throughout the vessel. LEGACY COMPONENT DESC: Pipe Flange
Due 20 January 2003
Resolved 22 May 2003
Fire Fighting › Fire Main
Issued 20 December 2002
Resolved
Replace valve handle on sea suction valve of starboard lazarette. LEGACY COMPONENT DESC: Valves
Condition: Unknown
Due 30 December 2002
Resolved 22 May 2003
Fire Fighting › Structural Fire Protection - General
Issued 20 December 2002
Resolved
Remove soot filled insulation in both engine rooms and replace with approved noncombustible material in accordance with 46 CFR 177.410 (c)(4) and 46 CFR 164.009. Replace insulation in areas where it has already fallen off. LEGACY COMPONENT DESC: Structural Bulkhead Construction
Condition: Improper/Lack of Maintenance
Due 20 January 2003
Resolved 22 May 2003
Electrical › Electrical Distribution System (service)
Issued 20 December 2002
Resolved
Properly attach grounding wires for starboard engine space fixed fire fighting system. LEGACY COMPONENT DESC: Grounding Conductor
Condition: Improper Installation
Due 20 January 2003
Resolved 22 May 2003
Construction/Loadline › Hull
Issued 20 December 2002
Resolved
Address the excessive amount of steel and rust acumulating in starboard engine room bilge in the vicinity of the rusting generator and its wasted steel foundation. LEGACY COMPONENT DESC: Bottom Plating
Condition: Improper/Lack of Maintenance
Due 20 January 2003
Resolved 22 May 2003
Documentation › Certificates/Documents
Issued 7 March 2002
Resolved
FCC Safety Cerificate is expired. Provide evidence of New FCC Safety Certificate. LEGACY COMPONENT DESC: FCC SSL
Due 7 April 2002
Resolved 22 May 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 7 March 2002
Resolved
Replace all expired medicines on vessel's First Aid Kit LEGACY COMPONENT DESC: First Aid Kit
Condition: Improper/Lack of Maintenance
Due 7 April 2002
Resolved 22 May 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 7 March 2002
Resolved
repair passenger seating accomodation, portside last seat, had abroken support and is missing one of the screws that fix the seat to the deck. LEGACY COMPONENT DESC: Seating Accomodations
Condition: Unknown
Due 7 April 2002
Resolved 22 May 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 7 March 2002
Resolved
Re-lable the maximum amount of passenger to be allowed on 2nd deck as per vessels stability letter. LEGACY COMPONENT DESC: 2nd Deck
Condition: Unknown
Due 5 June 2003
Resolved 8 April 2004
Resolution: The 2nd deck was re-lable as per vessel stability letter.
Lifesaving
Issued 6 June 2001
Resolved
Blank old AC overboard piping straboard side.
Condition: Unknown
Due 1 July 2001
Resolved 7 March 2002
Lifesaving
Issued 6 June 2001
Resolved
Provide handle for forward and aft doors.
Condition: Unknown
Due 1 July 2001
Resolved 22 May 2003
Lifesaving
Issued 6 June 2001
Resolved
Provide lifejacket donning placard for 2nd deck.
Condition: Unknown
Due 8 June 2001
Resolved 12 June 2001
Navigation
Issued 6 June 2001
Resolved
Poast emergency broadcast placard on bridge.
Condition: Unknown
Due 1 July 2001
Resolved 7 March 2002
Resolution: Outstanding requirement cleared during COI Inspection.
Engineering
Issued 6 June 2001
Resolved
Vibration on starboard shaft. Provide report on shaft condition and providerepairing option.
Condition: Unknown
Due 8 June 2001
Resolved 12 June 2001
Lifesaving
Issued 6 June 2001
Resolved
MArk aft door with the sign "Exit, Keep Clear".
Condition: Unknown
Due 1 July 2001
Resolved 12 June 2001
Electrical
Issued 30 June 2000
Resolved
Replace battery box covers for port and stbd main engines no later than 7 July, 2000.
Condition: Unknown
Due 7 July 2000
Resolved 3 July 2000
Engineering
Issued 30 June 2000
Resolved
Renew port and stbd main engine raw water suction hoses from strainer to raw water pump prior to carrying passengers.
Condition: Unknown
Due 3 July 2000
Resolved 3 July 2000
Lifesaving
Issued 30 June 2000
Resolved
PRIOR TO CARRYING PASSENGERS, REPAIR STROBE LIGHT FOR LIFEFLOAT #1
Condition: Unknown
Due 30 June 2000
Resolved 3 July 2000
Engineering
Issued 30 June 2000
Resolved
Repair leaking fuel hose connection at stbd main engine injection pump prior to carrying passengers.
Condition: Unknown
Due 3 July 2000
Resolved 3 July 2000
Electrical
Issued 30 June 2000
Resolved
Properly mount port engine battery selector switch prior to carrying passengers.
Condition: Unknown
Due 3 July 2000
Resolved 3 July 2000
Electrical
Issued 30 June 2000
Resolved
Remove all unused wiring on port and stbd main engines no later than 7 July, 2000.
Condition: Unknown
Due 7 July 2000
Resolved 3 July 2000
Engineering
Issued 30 June 2000
Resolved
PRIOR TO CARRYING PASSENGERS, REPAIR ENGINE SHUTDOWNS FOR PORT GENERATOR AND STBD MAIN ENGINE SO THAT ENGINES SHUTDOWN UPON DISCHARGE OF FIXED FIREFIGHTING SYSTEM.
Condition: Unknown
Due 30 June 2000
Resolved 3 July 2000
Construction/Loadline
Issued 30 June 2000
Resolved
Repair cracked/bent aft deck supports no later than 7 July, 2000.
Condition: Unknown
Due 30 July 2000
Resolved 7 March 2002
Lifesaving
Issued 30 June 2000
Resolved
Provide 6 CG approved day distress flares prior to carrying passengers.
Condition: Unknown
Due 3 July 2000
Resolved 3 July 2000
Navigation
Issued 30 June 2000
Resolved
Repair anchor light no later than 7 July, 2000. Vessel restricted to daytime operations only until repaired.
Condition: Unknown
Due 7 July 2000
Resolved 3 July 2000
Lifesaving
Issued 30 June 2000
Resolved
Provide additional 28 adult lifejackets for a total of 151 as per COI priorto carrying passengers.
Condition: Unknown
Due 3 July 2000
Resolved 3 July 2000
Fire Fighting
Issued 30 June 2000
Resolved
Provide additional B-I type CG approved fire extinguisher prior to carryingpassengers.
Condition: Unknown
Due 3 July 2000
Resolved 3 July 2000
Fire Fighting
Issued 30 June 2000
Resolved
Provide 1 B-II CG approved fire extinguisher at aft deck station prior to carrying passengers.
Condition: Unknown
Due 3 July 2000
Resolved 3 July 2000
Accommodation/Occupational Safety
Issued 30 June 2000
Resolved
Repair internal communications system or provide battery powered bull horn prior to carrying passengers.
Condition: Unknown
Due 3 July 2000
Resolved 3 July 2000
Engineering
Issued 30 June 2000
Resolved
Replace valve handle for port main engine raw water suction valve prior to carrying passengers.
Condition: Unknown
Due 3 July 2000
Resolved 3 July 2000
Engineering
Issued 30 June 2000
Resolved
Install lagging over port and stbd main engine turbocharger turbine housings, and exposed non-water cooled piping no later than 7 July, 2000.
Condition: Unknown
Due 7 July 2000
Resolved 3 July 2000
Construction/Loadline
Issued 30 June 2000
Resolved
Provide high bilge level alarms that are not interconnected to bilge pump float switches prior to carrying passengers.
Condition: Unknown
Due 3 July 2000
Resolved 3 July 2000
Engineering
Issued 30 June 2000
Resolved
Renew port electrical generator fuel return hose that meets the requirements of 46 CFR 182.720(e) prior to carrying passengers.
Condition: Unknown
Due 3 July 2000
Resolved 3 July 2000
Documentation
Issued 10 March 1999
Resolved
PROVIDE EVIDENCE OF FULL COMPLIANCE WITH CHEMICAL TESTING PROGRAM REQUIREMENTS PER 46 CFR PART 16.
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Construction/Loadline
Issued 1 March 1999
Resolved
REPAIR AND REWELD STBD AND PORT SIDE FUEL AND VENT BOXES CRACKS.
Condition: Unknown
Due 7 April 1999
Resolved 7 April 1999
Construction/Loadline
Issued 1 March 1999
Resolved
RENEW TRANSOM OUTBOARD BRACKETS AND REWELD AND CONTACT OFFICE FOR VISUAL_x001C_ INSPECTION.
Condition: Unknown
Due 7 April 1999
Resolved 7 April 1999
Documentation
Issued 11 January 1999
Resolved
VESSEL OPERATING BEYOND DRYDOCK HULL EXAM DATE. VESSEL TO BE HAULED OUT OF THE WATER AND PREPARE VESSEL FOR DRYDOCK INSPECTION I.A.W. 46CFR176.600.
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Documentation
Issued 11 January 1999
Resolved
REINSPECTION NOT CONDUCTED WITHIN REQUIRED TIME FRAME. MUST CONDUCT A FULL COI AND DRYDOCK INSPECTION TO REISSUE CERTIFICATE.
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999