Records from 2005 to 2026. Most recent: inspection, 25 March 2026.
Inspection history · 30
25 March 2026
Deficiency Check · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8333993
21 December 2025
Administrative Inspection · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8286064
8 September 2025
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8179686
16 July 2025
Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8188423
16 July 2025
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8192814
10 September 2024
COI Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7996229
6 September 2023
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7789830
7 September 2022
Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7542587
28 July 2022
Damage Survey · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7524211
24 February 2022
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7430361
26 October 2021
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7343576
31 August 2021
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7275567
1 July 2021
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7242403
29 June 2021
Damage Survey · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7239321
7 May 2021
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7221751
6 May 2021
Damage Survey · Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7191272
29 December 2020
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7117269
15 November 2019
Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6848651
26 December 2018
Annual Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6602821
5 January 2018
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6333105
7 October 2017
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6289451
6 October 2017
Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6282865
6 June 2017
Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6167951
5 June 2017
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6168742
4 June 2017
Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6166851
11 May 2017
Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6144307
30 March 2017
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6109673
7 September 2016
Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5989875
6 April 2016
Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5859473
4 January 2016
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5786135
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 December 2025
Resolved
The construction and arrangement of a vessel must allow the safe operations of the vessel in accordance with the terms of the COI giving consideration to provisions for a seaworthy hull, protections against fire, means of escape in case of sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passenger's and crew. Vessel made a report of running aground. Vessel shall not operate until Coast Guard vessel assessment is complete, provide a repair plan, make repairs as per approved repair plan, and Coast Guard Marine Inspector finalizes repairs.
46 CFR 177.100
Action required: 705 - Other - as specified
Resolved 6 January 2026
Resolution: Completed damage survey. Minor defects found in port hull, no further action required.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 September 2025
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. MI found excess oil in the engine room bilge on both port and starboard side. Clean all oil from bilges and notify local OCMI once complete.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 September 2025
Resolution: Received photo of clean bilge. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 September 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Dead end wires found in engine compartment. Remove dead end wiring and update electrical plans.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2025
Resolved 8 October 2025
Resolution: Received photo from POC. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 September 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Dead end wires found in in wheelhouse in several different locations. Remove all dead end wiring and update electrical plans.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2025
Resolved 29 September 2025
Resolution: Received photo of clean bilge. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 September 2025
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessel's life ring buoy was missing retroreflective tape and the vessel name. Add reflective tape and vessel name to life ring.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2025
Resolved 8 October 2025
Resolution: Received photo from POC. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 September 2025
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Bilge pump indicator at helm not operational. All bilge alarms and indicators where located on different alarm panels on the helm. Combined all alarms and indicators into one easy to see and properly label panel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 September 2025
Resolved 8 October 2025
Resolution: Received photo from POC. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 September 2025
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Labeling of life jacket stowage is not separate or marked directly on the location of the life jackets. Provide proper labeling and stowage of life jackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2025
Resolved 8 October 2025
Resolution: Received photo from POC. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 September 2025
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent extent necessary to determine that they are in suitable condition and fit for the service intended. MI noticed port side steering hose was being stressed as the vessel maneuvered. Find a way to relive stress on the steering hose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2025
Resolved 8 October 2025
Resolution: Received photo from POC. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 September 2024
Resolved
Port Aft spaces bilge alarm was inoperable due to a cut wire. Vessel must repair within 48 hours, until vessel repairs bilge alarm, vessels must provide a roving watch to check for water ingresshalfway through the 30 minute commute. Vessel must keep the bilge pump on auto until repaired to the satisfaction of the MI.
Action required: 705 - Other - as specified
Resolved 10 September 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 September 2024
Resolved
The bilge pump discharge line was leaking due to a broken hose clamp at a rate that deemed the pump obselete. The operator repaired the connection using one hose clamp but will be required to install a second hose clamp and / or replace the hose.
9/10/24 Vessel operator installed a second hose clamp and replaced the hose.
Action required: 10 - Deficiency Rectified
Resolved 10 September 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 September 2024
Resolved
Portable fire extinguisher was found on the upper deck in a locked box. Although the Captain stated they had the keys in the wheelhouse and the plexiglass could be broken, this was not a set up that made it readily accessible. Make extinguisher readily accessible.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2024
Resolved 10 September 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 September 2023
Resolved
Improper battery installation and support.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2023
Resolved 1 December 2023
Resolution: Batteries installed and supported
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 7 September 2022
Resolved
Piping which exceeds 150 degrees must be suitably insulated where necessary. Exhaust insulation needs to be replaced on the port side engine.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 October 2022
Resolution: Received documentation attesting to the proper insultation installation
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 July 2022
Resolved
STBD gear box OOC due to coolant leak into sump, replace gear box with new unit.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2022
Resolution: GEAR BOX REPLACED
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 October 2021
Resolved
REPLACE DAMAGED LIFERINGS, MISSING RETRO-REFLECTIVE TAPE AND BROKEN LIFE-LINE.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 November 2021
Resolved 5 November 2021
Resolution: Report with pictures received.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 26 October 2021
Resolved
CLEAN BILGES IN STBD MACHINERY SPACES AND GENERATOR MACHINERY SPACE.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 November 2021
Resolved 13 December 2021
Resolution: Spoke with [name withheld] have been deep cleaned. Pictures received 14DEC.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 October 2021
Resolved
REMOVE OR PROPERLY TERMINATE DEAD-END WIRES IN THE FOLLWOING LOCATIONS: 1) UNDER HELM, 2) STBD SIDE OVERHEAD AT FORWARD END OF PAX SPACE, 3) IN GENERATOR COMPARTMENT
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 November 2021
Resolved 5 November 2021
Resolution: Received report with pictures of properly terminated wires.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 October 2021
Resolved
INSTALL AUTOMATIC BILGE PUMP VISUAL INDICATORS AT HELM FOR EACH AUTOMATIC BILGE PUMP.
INSPECTOR FOLLOWING UP W/ OVERDUE DEFICIENCY AND WILL CLOSE WITH NEW ACTIVITY.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2021
Resolved 24 February 2022
Resolution: Picture received.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 29 June 2021
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 60 - Rectify deficiencies prior to movement
Resolved 30 June 2021
Resolution: Received report with pictures of repairs and statement of successful sea trial.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 May 2021
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. The vessel's 02 props and port rudder were damaged due to a grounding and repairs were conducted without Coast Guard oversight. Prove that all repairs are sufficient and that there is no further damage to the satisfaction of the attending Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2021
Resolution: Vessel repairs completed, sea trials - SAT.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 11 January 2021
Resolved
Provide servicing report for portable fire extinguishers and fixed systems. Due 11Feb2021.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2021
Resolved 23 January 2021
Resolution: Photo of service tags provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 January 2021
Resolved
Replace exhaust lagging from turbo to water injection piping, where identified. Due 11Feb2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2021
Resolved 23 January 2021
Resolution: Lagging installed.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 11 January 2021
Resolved
Replace plastic fire nozzle with metallic vary nozzle. Due 11Feb2021. Parts on order, due to arrive NLT 01Mar2021, def extended to reflect.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2021
Resolved 1 March 2021
Resolution: Replacement nozzle installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 11 January 2021
Resolved
Seal machinery space hatches x 3 to prevent water intrusion. Due 11Feb2021.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2021
Resolved 23 January 2021
Resolution: Hatches sealed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 November 2019
Resolved
Repair fixed firefighting system for generator (not properly wired) to ensure system operates as designed. Provide 3rd party report of satisfactory installation and testing. Due 15Dec2019.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2019
Resolved 16 December 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 November 2019
Resolved
Label manual pull stations for fixed firefighting systems to identify space. Due 15Dec2019.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2019
Resolved 16 December 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 November 2019
Resolved
Properly stow and label child sized lifejackets in location separate form adult lifejackets. Due 15Dec2019.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2019
Resolved 16 December 2019
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 15 November 2019
Resolved
Install approved first aid kit. Due 15Dec2019.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2019
Resolved 16 December 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 November 2019
Resolved
Remove tape holding bilge pump circuit breakers in closed position.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 15 November 2019
Resolved 15 November 2019
Resolution: Removed tape.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 26 December 2018
Resolved
Make public address system operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2019
Resolved 15 February 2019
Resolution: Installed new PA system. Ops check all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 December 2018
Resolved
Remove oil transfer pumps port and starboard that are no longer in use.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2019
Resolved 15 February 2019
Resolution: Both oil transfer pumps removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 December 2018
Resolved
Replace deteriorated cooling water hose from engine to exhaust.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2019
Resolved 15 February 2019
Resolution: Cooling water hose replaced with new hose.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 26 December 2018
Resolved
Repair cracked handrail on upper passenger deck aft.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2019
Resolved 15 February 2019
Resolution: Repaired crack on upper hand rail.
Lifesaving › Lifebuoys › Serviceable
Issued 5 January 2018
Resolved
Repair grablines for lifering.
Action required: 705 - Other - as specified
Due 9 February 2018
Resolved 10 January 2018
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 5 January 2018
Resolved
Repair noted lifejackets
Action required: 705 - Other - as specified
Due 9 February 2018
Resolved 10 January 2018
Engineering › Steering Gear System › Rudder
Issued 6 October 2017
Resolved
Vessel lost steering while under way. Vessel is restricted from carrying passengers until trouble shooting and repairs are completed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 October 2017
Engineering › Sea-water System (primary cooling) › Piping
Issued 30 March 2017
Resolved
Double hose clamp on discharge side of raw water filter.
Due 30 April 2017
Resolved 31 May 2017
Fire Fighting › Fire Main › Condition
Issued 30 March 2017
Resolved
The fire main suction pipe has a 2ft section of pedro/rubber hose that has deteriorated . Replace with hard pipe. Vessel is restricted from carrying passengers until corrected.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2017
Resolved 31 May 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 March 2017
Resolved
Replace expired contents of first aid kit.
Due 30 April 2017
Resolved 31 May 2017
Engineering › Sea-water System (primary cooling) › Piping
Issued 30 March 2017
Resolved
The generator raw water cooling suction piping is a rubber hose; replace with hard pipe.
Due 30 April 2017
Resolved 31 May 2017
Fire Fighting › Fire Main › Valves
Issued 30 March 2017
Resolved
Install a shutoff/Isolation valve at the fire hose hydrant.
Due 30 April 2017
Resolved 31 May 2017
Engineering › Electric Propulsion System › Junction
Issued 6 April 2016
Resolved
Junction box for Solenoid to transmission backed off.
Condition: Damaged By Earlier Event
Due 7 April 2016
Resolved 6 April 2016
Resolution: Junction box for Solenoid to transmission was put backed on with 'blue' thread lock.