MAURY USCG vessel records Sign in
← All vessels

ORION

ORION is a 1965 passenger vessel (inspected). The Coast Guard has recorded 42 inspections since 1983, most recently in January 2017, along with 61 deficiencies and 3 casualty investigations between 2002 and 2013.

Records from 1983 to 2017. Most recent: inspection, 30 January 2017.

Built
1965
Last inspected
30 January 2017
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB9839
Flag
UNITED STATES
366730790, 366983670 (licence lapsed)
Maury page id
psix-45088

Inspections, by type

…with no type recorded4
Years with a record 23 calendar years (1983–2017)
The 42 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)47.2 ft × 13.2 ft × 6.2 ft
Registered tonnagegross 31 / net 21
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEWART SEACRAFT, INC · BERWICK, LA, UNITED STATES · built 1965
Hull materialSteel
PropulsionDiesel Direct
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMECHANICSVILLE, MD
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it31 - Regulatory (Subpart C or D), Gross Ton
21 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI7583MMSI 366983670 · expired · compulsorily equipped · granted 26 April 2016, cancelled 27 June 2026
WDB9839MMSI 366983670 · expired · compulsorily equipped · granted 15 October 2004, cancelled 20 December 2014
WV5651MMSI 366730790 · cancelled · compulsorily equipped · granted 8 April 1997, cancelled 17 November 2003
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 42

30 January 2017 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6079578
25 May 2016 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5887363
26 April 2016 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5863518
12 July 2012 Hull Examination · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4377834
17 January 2012 DAPI Audit · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4217649
15 February 2011 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3947524
2 February 2010 Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3674186
17 February 2009 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3419484
11 August 2008 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3295599
1 April 2008 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3175704
17 April 2006 Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2626741
7 March 2006 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2622462
23 February 2005 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2297854
9 December 2004 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2256096
17 November 2004 Simplified Stability Test
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2256093
8 July 2004 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2126275
10 September 2002 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1674002
1 April 2002 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1599513
5 March 2002 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1491248
3 April 2000 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1399338
10 May 1994 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 858589
1 June 1993 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1161872
7 May 1993 Examination of Repairs
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1436761
16 April 1993 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1144330
31 January 1993 Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 835695
4 June 1992 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1259021
21 February 1992 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1471939
24 October 1991 Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1245489
7 March 1991 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1238884
5 February 1991 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1232882
21 June 1990 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 928168
1 May 1989 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 893709
31 January 1989 COI Inspection · Drydock Extension
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 895036
31 January 1989 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 897446
12 January 1989 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1230473
3 November 1988 Examination of Repairs
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 895034
5 February 1988 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1338733
10 June 1987 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1315247
22 January 1987 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1012677
14 January 1986 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 999708
23 January 1985 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1286571
19 January 1983 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1304295

Deficiency record · 61

Engineering › Bilge Water Management System › Pump
Issued 26 April 2016 Resolved
Repair the forward bilge pump located in the engine room. The affected bilge pump doesn’t operate with the bilge system is in the automatic mode.
Due 10 May 2016
Resolved 25 May 2016
Resolution: Forward bilge pump located in the engine room has been repaired; and works in auto-mode. OP Test was All SAT.
Engineering › Steering Gear System › Rudder
Issued 26 April 2016 Resolved
Repair the STBD-side rudder stop; so that it prevents the rudder from over steering.
Due 10 May 2016
Resolved 25 May 2016
Resolution: The STBD-side Rudder stop has been repaired. OP Test was All Sat.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 26 April 2016 Resolved
Provide proof of valid FCC Radio Safety Certificate. Vessel is restricted to 1000 feet from shore and is not authorized to carry passengers.
Due 10 May 2016
Resolved 25 May 2016
Resolution: Vessel Rep provided proof of current/valid FCC Safety Certificate. Vessel restriction of 1000 feet from shore & not being allowed to carry passengers has been lifted.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 26 April 2016 Resolved
Provide proof of current enrollment in the DAPI program.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 April 2016
Resolved 25 May 2016
Resolution: Vessel Rep provided proof of current enrollment in DAPI program.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 26 April 2016 Resolved
Install safety chains on the railing system located in the forward cargo area.
Due 10 May 2016
Resolved 25 May 2016
Resolution: Safety Chains for the railing system located in the forward cargo area have been installed.
Construction/Loadline › Hull › Hull Plating
Issued 12 July 2012 Resolved
46 CFR 177.100 The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of the COI giving provisions for a seaworthy hull. Rub rail is wasted on both port and starboard sides. Crop out wasted sections and replace with new.
Condition: Improper/Lack of Maintenance
Due 12 August 2012
Resolved 22 August 2012
Resolution: Rubrail cropped out and replaced with new.
Construction/Loadline › Structures › Deck Plating
Issued 12 July 2012 Resolved
46 CFR 177.100 The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of the COI giving provisions for a seaworthy hull. Deck plating on port quarter wasted near rub rail. Remove an area of 18" surrounding wasted area and replace with new.
Condition: Improper/Lack of Maintenance
Due 12 August 2012
Resolved 22 August 2012
Resolution: Deck plating cropped out and replaced with new.
Construction/Loadline › Hull › Strut/Cross Tie
Issued 12 July 2012 Resolved
46 CFR 177.100 The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of the COI giving provisions for a seaworthy hull. Starboard shaft strut skeg bent. Repair to new condition.
Due 12 August 2012
Resolved 22 August 2012
Resolution: Skeg straightened out.
Lifesaving › Hand Flares › Not on Board
Issued 15 February 2011 Resolved
VESSEL MISSING TWO RED FLARE, PROVIDE AS REQUIRED.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2011
Resolution: TWO RED FLARE PURCHASED AND PLACED ON BOARD.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 15 February 2011 Resolved
VESSEL MISSING TIDE AND CURRENT TABLE, PROVIDE AS REQUIRED.
Due 15 March 2011
Resolved 18 March 2011
Resolution: PROVIDED RECIEPT SHOWING THAT TIDE AND CURRENT TABLE AS BEEN PURCHASED AND PLACED ON BOARD.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 February 2011 Resolved
FIRST AID KIT MISSING EYEWASH, PROVIDE AS REQUIRED.
Due 15 March 2011
Resolved 18 February 2011
Resolution: PROVIDED RECEIPT SHOWING EYEWASH HAS BEEN PURCHASED.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 15 February 2011 Resolved
PROVIDE PROOF OF ENROLLMENT IN A DRUG AND ALCHOHOL PROGRAM FOR THE MASTERS RESPONCIBLE FOR NAVIGATING THE VESSEL.
Due 15 March 2011
Resolved 8 March 2011
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 2 February 2010 Resolved
FCC Safety Radio Certificate expired. Renew prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 February 2010
Resolved 3 March 2010
Resolution: Attended vessel and cleared above deficiency.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 2 February 2010 Resolved
Acohol test kits expired/Renew (2).
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 February 2010
Resolved 3 March 2010
Resolution: Attended vessel and cleared above deficiency.
Engineering › Bilge Water Management System › Pump
Issued 2 February 2010 Resolved
AFT engineroom bilge pump does not operate in auto mode and no visual indicator at control station. Repair/Replace.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 February 2010
Resolved 3 March 2010
Resolution: Attended vessel and cleared above deficiency.
Communications › Alarms/Indicators › High Water Alarm
Issued 2 February 2010 Resolved
Engineroom high water alarm visual indicator at steering station inop. Repair/replace.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 February 2010
Resolved 3 March 2010
Resolution: Attended vessel and cleared above deficiency.
Lifesaving › Lifefloat › Markings
Issued 2 February 2010 Resolved
Lifefoat needs capacity marking on side and name of vessel on paddles.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 February 2010
Resolved 3 February 2010
Resolution: Attended vessel and checked above deficiency which was corrected.
Construction/Loadline › Hull › Hull Plating
Issued 17 February 2009 Resolved
Aft main deck wasted at P/S engine room vents. Submit plan for temp repairs prior to operating with passengers and permanent repairs during June 2009 dry dock.
Action required: 705 - Other - as specified
Due 1 March 2009
Resolved 23 February 2009
Resolution: Received fax from Operator showing temp repairs and plan for permanent repairs at June 2009 dry dock.
Engineering › Sea-water System (primary cooling) › Pump
Issued 17 February 2009 Resolved
Stbd MDE raw water pump and associated piping wasted. Repair/renew as original and prove proper operation of system.
Action required: 705 - Other - as specified
Due 1 March 2009
Resolved 23 February 2009
Resolution: Received fax from Operator, raw water pump and piping cleaned and tested satisfactory.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 17 February 2009 Resolved
Port fuel tank has leak at flare fitting repair and prove proper operation prior to carying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 February 2009
Resolved 23 February 2009
Resolution: Received fax from Operator, replaced flare fitting and operated satisfactory.
Engineering › Bilge Water Management System › Hose
Issued 1 April 2008 Resolved
Replace PVC and rubber hose on suction side of engine rom fixed bilge system iaw 46 CFR 182.710. Replace with ferrious material.
Action required: 705 - Other - as specified
Due 1 May 2008
Resolved 23 April 2008
Resolution: Received fax from O/Op clearing above deficiency.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 1 April 2008 Resolved
Provide drug consortium information for master and crew iaw 46 CFR 16. Master had proof of enrollment and proof of random testing in last year on board.
Action required: 705 - Other - as specified
Due 1 May 2008
Resolved 23 April 2008
Resolution: Received fax from O/Op clearing above deficiency.
Construction/Loadline › Hull › Weld
Issued 17 April 2006 Resolved
Operator failed to get approval of modifictaions to hull.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2006
Resolved 10 May 2006
Resolution: Payment received for ticket.
Operations/Management › Casualty Reporting/Post-Casualty Actions › Notice of Marine Casualty
Issued 17 April 2006 Resolved
Operator failed to notify Coast Guard of a marine casualty immediately after suffering a fire aboard and also failed to provided written notification within 5 days.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2006
Resolved 10 May 2006
Resolution: Payment received for ticket.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 9 December 2004 Resolved
Repair and prove operation of automatic engine shutdown for fixed firefighting (should also shut down the generator).
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 December 2004
Resolved 14 January 2005
Engineering › Bilge Water Management System › Valve
Issued 9 December 2004 Resolved
Provide positive shutoff valves at hull penetration for 3 bilge pumps.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 December 2004
Resolved 14 January 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 9 December 2004 Resolved
Provide self-actuating floating waterlight for life ring and life float (2 total).
Action required: 705 - Other - as specified
Due 31 December 2004
Resolved 14 January 2005
Lifesaving › Lifefloat › Paddle
Issued 9 December 2004 Resolved
Provide 2 four foot paddles for life float, label with vessel name, and lash to life float.
Action required: 705 - Other - as specified
Due 31 December 2004
Resolved 21 January 2005
Resolution: Issued in error.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 December 2004 Resolved
Provide new bulb for sternlight.
Action required: 705 - Other - as specified
Due 31 December 2004
Resolved 14 January 2005
Engineering › Bilge Water Management System › Pump
Issued 9 December 2004 Resolved
Provide portable bilge pump with 5 gal/minute operating capacity.
Action required: 705 - Other - as specified
Due 31 December 2004
Resolved 14 January 2005
Deck/Cargo › Holds/Tanks › Ullage
Issued 9 December 2004 Resolved
Seal all openings on side of fuel tank, and have tank pressure tested by CG marine inspector.
Action required: 705 - Other - as specified
Due 14 March 2005
Resolved 23 February 2005
Construction/Loadline
Issued 7 May 1993 Resolved
Crop and renew 12" X 18" around area of deterioration on starboard side in chain locker just below spray rail using full penatration welds and 2" radius on the corners.
Condition: Unknown
Due 7 May 1993
Resolved 7 May 1993
Fire Fighting
Issued 21 February 1992 Resolved
Provide proper marine bracket for all B-II fire Extinguishers.
Condition: Unknown
Due 21 February 1992
Resolved 21 February 1992
Lifesaving
Issued 5 February 1991 Resolved
PROVIDE COPY OF SAFETY ORIENTATION
Condition: Unknown
Due 5 February 1991
Resolved 5 February 1991
Navigation
Issued 5 February 1991 Resolved
PROVIDE COPY OF 1991 TIDE TABLES AND CURRENT COAST PILOT
Condition: Unknown
Due 5 February 1991
Resolved 5 February 1991
Deck/Cargo
Issued 5 February 1991 Resolved
PROOF/WEIGHT TEST CARGO BOOMS AND STENCIL
Condition: Unknown
Due 5 February 1991
Resolved 5 February 1991
Engineering
Issued 31 January 1989 Resolved
MARK EMERGENCY VUEL SHUT-OFF VALVES
Condition: Unknown
Due 31 January 1989
Resolved 31 January 1989
Electrical
Issued 31 January 1989 Resolved
REPLACE MISSING AMPMETER PROTECTIVE LENSE FOR 12 VOLT CONSTAVOLT BATTERY CHARGER
Condition: Unknown
Due 31 January 1989
Resolved 31 January 1989
Navigation
Issued 31 January 1989 Resolved
PROVIDE VALID FCC OPERATORS LICENSE
Condition: Unknown
Due 31 January 1989
Resolved 31 January 1989
Navigation
Issued 31 January 1989 Resolved
ADJUST STERN LIGHT TO SHOW CORRECT ARC IN RELATION TO VESSEL
Condition: Unknown
Due 31 January 1989
Resolved 31 January 1989
Navigation
Issued 31 January 1989 Resolved
ADJUST ANCHOR LIGHT TO BE HORIZONTAL
Condition: Unknown
Due 31 January 1989
Resolved 31 January 1989
Documentation
Issued 31 January 1989 Resolved
PROVIDE VESSEL COPY OF SUBCHAPTER "T" CFR
Condition: Unknown
Due 31 January 1989
Resolved 31 January 1989
Construction/Loadline
Issued 31 January 1989 Resolved
REPLACE CARGO BOOM GOOSENECK FITTING
Condition: Unknown
Due 31 January 1989
Resolved 31 January 1989
Electrical
Issued 31 January 1989 Resolved
INSTALL PERMANENT BATTERY CONNECTORS FOR ALL CABLES ON BATTERIES
Condition: Unknown
Due 31 January 1989
Resolved 31 January 1989
Engineering
Issued 31 January 1989 Resolved
INSTALL EMERGENCY FUEL SHUT-OFF CONNECTION FOR STARBOARD FUEL TANK
Condition: Unknown
Due 31 January 1989
Resolved 31 January 1989
Construction/Loadline
Issued 3 November 1988 Resolved
CONDUCT SAT HOSE TEST OF RENEWED PORT AND STBD DIESEL EXHAUST LINE IN WAY OF STERN. CONDUCT HOSE TEST OF SMALL INSERT (4'X4") IN MAIN DECK ON STBD SIDE AFT/ ALSO HOSE TEST NEW WELD ON STBD ON STBD SIDE AFT IN WAY OF MAIN DECK AND SIDE SHELL (ROUND PLATE)
Condition: Unknown
Due 3 November 1988
Resolved 3 November 1988
Electrical
Issued 5 February 1988 Resolved
REPLACE KNIFE SWITCH IN E.R. WITH CLOSED SWITCH
Condition: Unknown
Due 5 February 1988
Resolved 5 February 1988
Electrical
Issued 5 February 1988 Resolved
REMOVE OR END IN JUNCTION BOX THE LOOSE ELECTRICAL CABLE IN HEAD
Condition: Unknown
Due 5 February 1988
Resolved 5 February 1988
Navigation
Issued 5 February 1988 Resolved
RELOCATE STERN LIGHT AFT OF THE AFTER MAST TO CLEAR OBSTRUCTED FIELD OF VIEW
Condition: Unknown
Due 5 February 1988
Resolved 5 February 1988
Lifesaving
Issued 5 February 1988 Resolved
REPLACE THE RING BUOY LOCATED ON PORT SIDE
Condition: Unknown
Due 5 February 1988
Resolved 5 February 1988
Fire Fighting
Issued 5 February 1988 Resolved
PROVIDE A HYDROSTATIC TEST OF BII CO2 FIRE EXTINGUISHER IN GALLEY
Condition: Unknown
Due 5 February 1988
Resolved 5 February 1988
Engineering
Issued 5 February 1988 Resolved
RENEW WITH APPROVED FUEL LINE THE SUPPLY LINE TO THE STARBOARD PRIMARY FUEL FILTER
Condition: Unknown
Due 5 February 1988
Resolved 5 February 1988
Unknown
Issued 10 June 1987 Resolved
RENEW STBD VENT TO FOREPEAK.
Condition: Unknown
Due 10 June 1987
Resolved 10 June 1987
Unknown
Issued 10 June 1987 Resolved
PROVIDE CLOSURES FOR TWO FOREPEAK VENTS AND TWO LAZARETTE VENTS.
Condition: Unknown
Due 10 June 1987
Resolved 10 June 1987
Unknown
Issued 10 June 1987 Resolved
REMOVE CABLE (ELECTRICAL) IN FOREPEAK OR PROPERLY END IN JUNCTION BOX.
Condition: Unknown
Due 10 June 1987
Resolved 10 June 1987
Unknown
Issued 10 June 1987 Resolved
PROPERLY SUPPORT ELECTRICAL CABLE BELOW MAIN CABIN. CABLE SHALL BE SUPPORTED APPROX EVERY 24'.
Condition: Unknown
Due 10 June 1987
Resolved 10 June 1987
Unknown
Issued 10 June 1987 Resolved
PROPERLY SUPPORT AND CAP UNUSED FUEL TUBING BELOW MAIN CABIN TUBING SHALL BE REMOVED FROM BUNDLE OF ELECTRICAL CABLES AND PROPERLY SUPPORTED. LINE SHALL BE CAPPED ADJACENT TO SHUT-OFF VALVE. FUEL TUBING MAY BE REMOVED AS AN OPTION TO ABOVE.
Condition: Unknown
Due 10 June 1987
Resolved 10 June 1987
Unknown
Issued 10 June 1987 Resolved
PROVIDE FOR REMOTE OPERATION OF OVERBOARD DISCHARGE VALVES FOR PORT AND STBD SINKS.
Condition: Unknown
Due 10 June 1987
Resolved 10 June 1987
Unknown
Issued 10 June 1987 Resolved
RENEW FLEXIBLE FUEL LINES FROM FUEL TANKS.
Condition: Unknown
Due 10 June 1987
Resolved 10 June 1987
Fire Fighting
Issued 23 January 1985 Resolved
RETEST AND RECHARGE CO2 B-II FIRE EXTINGUISHER. IF VESSEL IS OPERATED PRIORTO RETEST, REPLACEMENT IS TO BE PROVIDED FOR OPERATION.
Condition: Unknown
Due 23 January 1985
Resolved 23 January 1985
Lifesaving
Issued 23 January 1985 Resolved
REPLACE OUTDATED FLARES WITH SIX COAST GUARD APPROVED RED HAND HELD FLARES.
Condition: Unknown
Due 23 January 1985
Resolved 23 January 1985

Casualty record · 3

10 September 2002Routine · role: Involved in a Marine Casualty · 2 injured · activity 1674002
7 March 2006Routine · role: Involved in a Marine Casualty · activity 2622462
19 February 2013Routine · role: Involved in a Marine Casualty · activity 4540119
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.