Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 April 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDL5054
451169
Flag
UNITED STATES
Maury page id
psix-451169

Documentation record

Registered dimensions (L × B × D)49.6 ft × 14.6 ft × 4.7 ft
Registered tonnagegross 19 / net 15
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMARCO SEATTLE INC · SEATTLE · built 1996
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationTri Hull
Hailing portSAN FRANCISCO, CA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 19 November 2025 · expires 30 November 2026
Service, as the file records itOil Recovery
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it19 - Simplified, Gross Ton
15 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 13 inspections, each with its date, unit and type; 7 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 13

15 April 2025 Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8111782
30 April 2024 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7903751
8 May 2023 Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7683588
12 December 2022 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7608106
20 July 2022 Deficiency Check · Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7505604
5 May 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7190434
20 April 2021 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7171367
1 July 2020 Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6993658
10 April 2019 Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6660128
1 May 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6403389
25 April 2017 Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6134141
10 May 2016 Cargo Tank Internal · Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5873866
18 April 2016 COI Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5856592

Deficiency record · 7

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 April 2025 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Port generator leaks diesel at fuel injectors while running. 46 CFR 182.200(a)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2025
Resolved 23 April 2025
Resolution: Operator emailed photo of new coupler installed. Photo uploaded to deficiency documents.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 April 2025 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Identification of the items may be in words, or the appropriate symbols in IMO Resolution A.760(18) (incorporated by reference; see 46 CFR 175.600). Letters and numbers must be at least 50 millimeters (2 inches) high. Symbols must be at least 100 mm (4 inches) square. Life jacket stowage cabinet is not labeled nor is quantity indicated. 46 CFR 185.604(f)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2025
Resolved 23 April 2025
Resolution: Operator emailed photo of life jacket cabinet labeled per requirements. Photo uploaded to deficiency documents.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 15 April 2025 Resolved
Waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Waste receptacles in galley and fiddley are constructed of plastic. 46 CFR 177.405(f)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2025
Resolved 23 April 2025
Resolution: Operator emailed photos of plastic waste receptacles replaced with metallic construction. Photos uploaded to deficiciency documents.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 May 2023 Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Life ring buoy did not have reflective tape. Correct reflective tape was added.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 9 May 2023
Resolution: Reflective tape was added.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 July 2022 Resolved
A pre-engineered fixed gas fire extinguishing system must be installed in accordance with the manufacturer's instructions. During test of fireboy system, MI discovered that the engines can be started without switching to "Override" on control panel. After actuation, engines should not be able to start in "normal" mode.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2022
Resolved 18 August 2022
Resolution: Witnessed satisfactory test of the Fireboy system.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 July 2022 Resolved
Fire extinguishing equipment installed on a vessel in excess of requirements must be designed, constructed, installed and maintained with a recognized industry standard acceptable to the Commandant. Fire pump installed does not have a pressure gauge. MI was unable to determine 60psi output in order to meet fire pump specs listed in 46 CFR 181.300(b).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2022
Resolved 13 October 2022
Resolution: Witnessed gauge installed. Fire pump did not meet 60 psi. See narrative for details.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 20 July 2022 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. During the Internal Structural Exam, a noticeable amount of pitting was discovered in compartments on either side of cargo tank. Some pitting measured greater than 25% scantling with pit gauge. Operator to remove all equipment and wood sole in these comportments for a follow on inspection by attending Marine Inspector. Vessel to propose temporary or permanent repair proposal for approval by OCMI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2022
Resolved 13 October 2022
Resolution: Vessel has proposed a temporary repair and increased inspection scheme. See narrative for details.