Records from 1985 to 2022. Most recent: inspection, 23 April 2022.
Inspection history · 65
23 April 2022
Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7437511
16 July 2008
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3321806
28 May 2008
Deficiency Check · Periodic Inspection · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3213813
25 April 2008
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3192068
26 March 2008
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3184559
16 October 2007
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3078442
11 September 2007
Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3078670
27 July 2007
Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3077139
12 July 2007
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3071416
7 June 2007
Administrative Inspection
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2954680
14 March 2007
Administrative Inspection · Drydock Extension
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2888069
14 August 2006
Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2747851
21 March 2006
Annual Inspection · MTSA Verification
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2606419
24 February 2006
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2591260
12 April 2005
COI Inspection · MTSA Verification · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2326090
3 May 2004
Re-Inspection
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 2061257
23 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2004820
19 May 2003
Annual Inspection
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 1802517
4 June 2002
Deficiency Check
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 1626201
29 April 2002
Re-Inspection
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 1610567
13 March 2002
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1600439
17 October 2001
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1074342
10 July 2001
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1069292
20 April 2001
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1405165
2 August 2000
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1053538
29 June 2000
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 820003
29 June 2000
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 820004
6 April 2000
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1429349
17 May 1999
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 798449
6 April 1999
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1423160
6 April 1998
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1414984
7 April 1997
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1435916
6 April 1997
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1435915
16 January 1997
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1098591
26 June 1996
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 932916
27 March 1996
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1390237
30 March 1995
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1154149
6 April 1994
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 857413
3 June 1993
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 839637
20 May 1993
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1436772
27 July 1992
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 958107
19 May 1992
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1270117
19 May 1992
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1405320
14 April 1992
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 958975
14 April 1992
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1456061
31 March 1992
Drydock Extension
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 959325
31 March 1992
Drydock Extension
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1266690
25 July 1991
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1252905
1 May 1991
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 901639
1 May 1991
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1269789
1 May 1991
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1270721
20 February 1991
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1216987
2 May 1990
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1237067
31 August 1989
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1194812
14 July 1989
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 886818
20 June 1989
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1346479
28 April 1989
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1202361
11 May 1988
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1202110
6 May 1987
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1025266
20 February 1987
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1318043
28 January 1987
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1318544
7 November 1986
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1329588
18 September 1986
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1002093
15 July 1986
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1305484
21 May 1985
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 983853
Engineering › Bilge Water Management System › Not Operational
Issued 28 May 2008
Resolved
Prior to 15JUNE08, Prove proper operation of the vessel bilge system or submit plans on the proposed modifications.
Condition: Unknown
Due 15 June 2008
Resolved 16 July 2008
Engineering › Fuel Oil Service System › Piping
Issued 28 May 2008
Resolved
Prior to carrying passengers replace the MDE’s flexible return fuel lines located at the fuel tank.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 June 2008
Resolved 16 July 2008
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 28 May 2008
Resolved
Renew deteriorated retro on the 2nd deck, port side PFD’s.
Condition: Improper/Lack of Maintenance
Due 28 June 2008
Resolved 31 October 2008
Resolution: COI surrendered.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 28 May 2008
Resolved
Properly secure (currently duck taped) the port side, upper stair carpet.
Condition: Improper/Lack of Maintenance
Due 28 June 2008
Resolved 16 July 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 May 2008
Resolved
Properly wire (remove romex) stern, 2nd deck, emergency light.
Condition: Improper Installation
Due 28 June 2008
Resolved 16 July 2008
Fire Fighting › Fire Hydrants › Condition
Issued 28 May 2008
Resolved
Ensure all fire stations are properly outfitted at all times.
Condition: Placed in Improper Service
Due 28 June 2008
Resolved 16 July 2008
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 28 May 2008
Resolved
Properly label the third deck, PFD locker.
Condition: Unknown
Due 15 September 2008
Resolved 15 September 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 May 2008
Resolved
Install CG approved Navigational lights.
Condition: Placed in Improper Service
Due 1 January 2009
Resolved 31 October 2008
Resolution: COI surrendered.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 28 May 2008
Resolved
Ensure the vessel has a copy of the navigational rules onboard.
Condition: Unknown
Due 28 June 2008
Resolved 16 July 2008
Operations/Management › Pollution › Control of Garbage
Issued 28 May 2008
Resolved
Post MARPOL placard.
Condition: Placed in Improper Service
Due 28 June 2008
Resolved 16 July 2008
Stability › Unintentional Flooding › General
Issued 28 May 2008
Resolved
Label all WTD’s to match the alarm panel.
Condition: Unknown
Due 28 June 2008
Resolved 16 July 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 May 2008
Resolved
Properly wire (remove romex) bilge/fire pump.
Condition: Placed in Improper Service
Due 28 June 2008
Resolved 16 July 2008
Stability › Unintentional Flooding › General
Issued 28 May 2008
Resolved
Properly secure the #3 WTD open indicator.
Condition: Unknown
Due 28 June 2008
Resolved 16 July 2008
Electrical › Electrical Distribution System (service) › Junction Box
Issued 28 May 2008
Resolved
Install junction boxes at the termination point for the new high level bilge alarms.
Condition: Placed in Improper Service
Due 28 June 2008
Resolved 15 September 2008
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 28 May 2008
Resolved
Ensure all crewmen have been pre-employment drug tested prior to using in a safety sensitive positions.
Condition: Placed in Improper Service
Due 28 June 2008
Resolved 16 July 2008
Engineering › Steering Gear System › Rudder Bearing
Issued 28 May 2008
Resolved
Prior to 01JAN09 or next time the vessel is drydocked, replace the port and stbd rudder post bearings.
Condition: Unknown
Due 1 January 2009
Resolved 31 October 2008
Stability › Unintentional Flooding › General
Issued 16 October 2007
Resolved
Submit proposed hull and stability modifications to MSC for approval prior to 31DEC08.
Condition: Placed in Improper Service
Due 1 January 2009
Resolved 31 October 2008
Resolution: COI surrendered.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 12 July 2007
Resolved
Ensure vessel has a current light lists.
Condition: Unknown
Due 12 August 2007
Resolved 12 July 2007
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 12 July 2007
Resolved
Post emergency broadcast placard
Condition: Unknown
Due 12 August 2007
Resolved 12 July 2007
Communications › Public Address System › Loudspeaker
Issued 12 July 2007
Resolved
Prove proper operation of PA system, several speakers did not work. Ensure system/speakers are designed for outdoors installation.
Condition: Placed in Improper Service
Due 12 August 2007
Resolved 27 July 2007
Operations/Management › Drills/Instruction › Abandon Ship
Issued 12 July 2007
Resolved
Post emergency instruction list.
Condition: Unknown
Due 12 July 2007
Resolved 12 August 2007
Engineering › Compressed Air System (control) › Valve
Issued 12 July 2007
Resolved
Repair/Replace air receiver relief valves, and demonstrate proper operation of relief valves.
Condition: Improper/Lack of Maintenance
Due 17 October 2007
Resolved 28 April 2008
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 12 July 2007
Resolved
Remove all gear behind 3rd deck coolers (STBD side)
Condition: Improper/Lack of Maintenance
Due 12 July 2007
Resolved 12 July 2007
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 12 July 2007
Resolved
Remove all extension cord running from 2nd to 3rd deck concession area.
Condition: Improper Installation
Due 12 July 2007
Resolved 12 July 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 July 2007
Resolved
Remove electrical power strips in 3rd deck concession area.
Condition: Improper Installation
Due 12 July 2007
Resolved 12 July 2007
Electrical › Lighting (emergency) › Lighting Fixture
Issued 12 July 2007
Resolved
No deck lighting for 3rd deck area, submit a proposal to CG for Installing temporary deck lighting for 3rd deck. Power to 3rd deck has been removed due to modification to bar area.
Condition: Unknown
Due 1 January 2009
Resolved 31 October 2008
Resolution: COI surrendered.
Lifesaving › Lifebuoys › Serviceable
Issued 12 July 2007
Resolved
Replace 3 Ring lifebuoys, line has deteriorated and not serviceable.
Condition: Improper/Lack of Maintenance
Due 12 July 2007
Resolved 12 July 2007
Lifesaving › Lifebuoys › Serviceable
Issued 12 July 2007
Resolved
Repair/replace ring buoy light, battery cover missing retaining clip. Attach a 3-foot lanyard and corrosion resistant clip to light.
Condition: Unknown
Due 12 July 2007
Resolved 13 July 2007
Lifesaving › Lifebuoys › Stowage
Issued 12 July 2007
Resolved
Properly mount all Ring lifebuoys using an approved bracket.
Condition: Improper/Lack of Maintenance
Due 12 August 2007
Resolved 27 July 2007
Electrical › Electric Supply System (service) › Cable
Issued 12 July 2007
Resolved
Submit for approval electrical plans for 3rd deck concession / deck area.
Due 17 October 2007
Resolved 28 April 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 July 2007
Resolved
Remove all dead ended wires in 3rd deck concession area. Wires must be removed back to power supply.
Due 30 September 2007
Resolved 27 July 2007
Electrical › Electrical Distribution System (service) › Junction Box
Issued 12 July 2007
Resolved
Remove open junction box mounted on top of breaker box (2nd deck bar closet).
Condition: Improper/Lack of Maintenance
Due 26 July 2007
Resolved 27 July 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 12 July 2007
Resolved
Move fire extinguisher from 2nd deck bar closet or remove all gear obstructing access to extinguisher.
Condition: Improper Installation
Due 12 July 2007
Resolved 12 July 2007
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 12 July 2007
Resolved
Repair electrical outlet box in overhead of 2nd deck bar.
Condition: Improper/Lack of Maintenance
Due 26 July 2007
Resolved 27 July 2007
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 12 July 2007
Resolved
Install independent power supply for vessel security system. Currently system is being plugged into an outlet. During inspection I observed system had been unplugged without any knowledge. (MTSA issue.)
Condition: Improper Installation
Due 17 October 2007
Resolved 28 April 2008
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 12 July 2007
Resolved
Mount electrical outlet box on 2nd deck, in overhead. Outlet box being held by nylon tie wire ties.
Condition: Improper Installation
Due 12 July 2007
Resolved 12 July 2007
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 12 July 2007
Resolved
Provide a location for stowage of 1st deck life jackets. All life jackets must be stowed to be readily accessible to all passengers and not requiring crew assistance to gain access.
Due 21 August 2007
Resolved 21 August 2007
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 12 July 2007
Resolved
Replace all unserviceable life jackets, (total of 229, 197 were kapock).
Condition: Improper/Lack of Maintenance
Due 12 July 2007
Resolved 12 July 2007
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 12 July 2007
Resolved
Vessel short 62 lifejackets, only 375 adult PFD’s not the required 437. Vessel is restricted to no more than 375 passengers, even after stability issue is resolved, until additional PDF’s are onboard.
Condition: Unknown
Due 21 August 2007
Resolved 27 July 2007
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 12 July 2007
Resolved
Properly mark all new life jackets.
Condition: Unknown
Due 21 August 2007
Resolved 12 July 2007
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 12 July 2007
Resolved
Properly stow/mount CO2 cylinders bottles for soda.
Condition: Improper Installation
Due 12 July 2007
Resolved 12 July 2007
Documentation › Markings/Placards › Lifejacket Placard
Issued 12 July 2007
Resolved
Post Lifejacket donning placards, at least 4 per deck should be posted.
Condition: Unknown
Due 26 July 2007
Resolved 12 July 2007
Electrical › Electric Supply System (service) › Cable
Issued 12 July 2007
Resolved
Remove power cable in overhead for track lighting on 2nd. . Power cable is exposed and still connected in breaker box.
Condition: Unknown
Due 26 July 2007
Resolved 27 July 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 July 2007
Resolved
Ensure first aid kit meets 46 CFR 184.710 . (items in first aid kit are/have expired).
Condition: Improper/Lack of Maintenance
Due 26 July 2007
Resolved 12 July 2007
Electrical › Lighting (emergency) › Lighting Branch Circuit
Issued 12 July 2007
Resolved
Prove proper operation of emergency lights. (light on all stairs did not work) While U/W you must provide pesonnel on stairs with flash lights in an emergency, until requirment is cleared.
Condition: Improper/Lack of Maintenance
Due 21 August 2007
Resolved 21 August 2007
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 12 July 2007
Resolved
Remove all gear hanging on electrical wires & cables. ( 2nd deck bar closet).
Due 12 July 2007
Resolved 12 July 2007
Accommodation/Occupational Safety › Ventilation › General
Issued 12 July 2007
Resolved
Clean exhaust fan,1st deck bar.
Condition: Improper/Lack of Maintenance
Due 26 July 2007
Resolved 13 July 2007
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 12 July 2007
Resolved
Repair deck penetration in 1st deck bar. Deck is a fire boundary, not sealed and with soda lines going through deck. Vessel will be going to the yards in oct.
Condition: Improper Installation
Due 31 October 2007
Resolved 28 April 2008
Engineering › Bilge Water Management System › Piping
Issued 12 July 2007
Resolved
Prove proper operation of bilge system. Ensure check valves and stop valves installed are working. Bilge pump would not dewater, and check valves were not operational.
Condition: Improper/Lack of Maintenance
Due 17 October 2007
Resolved 28 April 2008
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 12 July 2007
Resolved
On 1st deck overheads, remove all dead ended cables, cover all open junction boxes and remove any trash.
Condition: Improper/Lack of Maintenance
Due 12 September 2007
Resolved 12 September 2007
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 12 July 2007
Resolved
Submit a repair proposal to repair the deck (next to toilet ) in the men’s head. Head is not to be used until repaired and inspected by CG marine inspector. vessel will be going to the yards in oct.
Condition: Improper/Lack of Maintenance
Due 17 October 2007
Resolved 28 April 2008
Accommodation/Occupational Safety › Washroom/Toilet › Location
Issued 12 July 2007
Resolved
Submit a proposal for temporary men’s facility until repair.
Due 12 July 2007
Resolved 12 July 2007
Resolution: Vessel installed a Port a potty on the third deck near center line. Since the added weight was placed on the third deck and the previous stability issue, we reduced the allowed personnel on 3 deck.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 12 July 2007
Resolved
Clean engine room bilges, remove all trash.
Condition: Improper/Lack of Maintenance
Due 21 August 2007
Resolved 21 August 2007
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 12 July 2007
Resolved
Install lagging on bare generator exhaust, pipes are directly around high-pressure oil and fuel.
Condition: Unknown
Due 28 June 2008
Resolved 16 July 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 12 July 2007
Resolved
Remove flood light bulb and install globe over light fixture. STBD side engine room.
Condition: Improper/Lack of Maintenance
Due 12 July 2007
Resolved 12 July 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 July 2007
Resolved
Install covers over all rotating pulleys on MDE. There are covers on the front, but open on sides.
Condition: Unknown
Due 26 July 2007
Resolved 27 July 2007
Electrical › Electric Supply System (service) › Battery Conductor
Issued 12 July 2007
Resolved
Replace 12 volt battery that has melted part of post, and wire. Make repairs and identify possible cause.
Condition: Unknown
Due 12 July 2007
Resolved 12 July 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 12 July 2007
Resolved
Repair deck light on STDB side aft, hanging by wire.
Condition: Unknown
Due 12 July 2007
Resolved 12 July 2007
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 12 July 2007
Resolved
Provide a servicing report from a qualified MDE servicing facility, verifying the all engines systems are operating within manufactures normal standards.
Condition: Unknown
Due 6 June 2008
Resolved 15 September 2008
Engineering › Diesel Engine (auxiliary) › Air Cleaner
Issued 12 July 2007
Resolved
Repair louver doors on STBD next to emergency generator. Falling off and being held by straps.
Condition: Unknown
Due 26 July 2007
Resolved 27 July 2007
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 12 July 2007
Resolved
Remove all items and oil being stored on deck in aft section, next to generator.
Due 26 July 2007
Resolved 27 July 2007
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 12 July 2007
Resolved
Install Lagging on aft generator, bare exhaust next to high pressure fuel lines.
Condition: Unknown
Due 17 October 2007
Resolved 28 May 2008
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 12 July 2007
Resolved
Remove all oil and trash under aft generator.
Due 21 August 2007
Resolved 12 July 2007
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 12 July 2007
Resolved
Clean the aft generators windings; they are coated in oil & dirt, which can cause a fire.
Condition: Improper/Lack of Maintenance
Due 21 August 2007
Resolved 21 August 2007
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 12 July 2007
Resolved
Mount 220 outlet on the stern next to electrical panel, ( just hanging).
Condition: Unknown
Due 26 July 2007
Resolved 27 July 2007
Engineering › Diesel Engine (propulsion-electric) › Air Cleaner
Issued 12 July 2007
Resolved
Clean MDE supply air filter.
Due 27 July 2007
Resolved 27 July 2007
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 July 2007
Resolved
Repair broken rail on main deck , STBD
Condition: Unknown
Due 26 July 2007
Resolved 27 July 2007
Electrical › Lighting (emergency) › Lighting Fixture
Issued 12 July 2007
Resolved
Provide temp means for emergency lighting until installed emergency lighting is working.
Condition: Unknown
Due 12 July 2007
Resolved 12 July 2007
Stability › Incline Test › General
Issued 7 June 2007
Resolved
The vessel may carry only 375 passengers until the vessel's stability is verified by a Naval Engineer or Professional Engineer and the calculations submitted to the U. S. Coast Guard Marine Safety Center for approval. In addition to the reduced passenger count, the following passenger deck restrictions apply: Second deck, 82 passengers; Third Deck, 93 passengers; Fourth Deck, NONE.
Condition: Placed in Improper Service
Due 1 January 2009
Resolved 31 October 2008
Resolution: COI surrendered.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 21 March 2006
Resolved
Perform Man overboard drills to the satisfaction of the MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2006
Resolution: Recieved lettee master staing satisfactory drills were completed.
Construction/Loadline › Structures › Door
Issued 21 March 2006
Resolved
Adjust dogs on WTD. Prove seal by light/chalk test.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2006
Resolved 31 March 2006
Resolution: Pictures sent to verify compliance
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 21 March 2006
Resolved
Engineroom fire hazard - clean and wipe down engines and bilges
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2006
Resolved 31 May 2006
Resolution: pictures were sent to MI to verify compliance.
Engineering › Bilge Water Management System › Piping
Issued 21 March 2006
Resolved
Clean all screens for bilge suction piping.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2006
Resolved 31 March 2006
Resolution: Completed by pictures.
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 March 2006
Resolved
Terminals on battery cable corroded.
Action required: 705 - Other - as specified
Resolved 12 July 2007
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 21 March 2006
Resolved
Stencil children and adults on storage cabinet.
Action required: 705 - Other - as specified
Resolved 12 July 2007
Engineering › Diesel Engine (propulsion-direct drive) › Distributor (fuel injection)
Issued 21 March 2006
Resolved
Replace fuel hose with wire braided or steel piping on stbd Main Diesel Engine.
Action required: 705 - Other - as specified
Resolved 12 July 2007
Engineering › Compressed Air System (start air) › Valve
Issued 21 March 2006
Resolved
Prove relief valves relieve at correct pressure.
Action required: 705 - Other - as specified
Resolved 12 July 2007
Construction/Loadline › Structures › Door
Issued 21 March 2006
Resolved
WTH on Main deck dogs are siezed. Reapir prove seal.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 March 2006
Resolution: Completed verified by pictures.
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 March 2006
Resolved
Properly secure wiring through out vessel.
Action required: 705 - Other - as specified
Resolved 12 July 2007
Lifesaving › Lifejacket/PFD (Type III) › Condition
Issued 21 March 2006
Resolved
Trashed 90 life jackets vessel restricted to 349 persons.
Action required: 705 - Other - as specified
Resolved 12 July 2007
Documentation › Markings/Placards › Warning Signs
Issued 21 March 2006
Resolved
Provide an emergency Broadcast Placard for the Pilot House.
Action required: 705 - Other - as specified
Resolved 12 July 2007
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 21 March 2006
Resolved
Properly install and wire receptacle in to Circuit breaker box.
Action required: 705 - Other - as specified
Resolved 28 May 2008
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 21 March 2006
Resolved
properly stow CO2 cylinder bottles for soda.
Action required: 705 - Other - as specified
Due 12 July 2007
Resolved 12 July 2007
Engineering › Diesel Engine (propulsion-direct drive) › Piping (air intake)
Issued 21 March 2006
Resolved
J/W and L/O guages inop on console in Pilot house.
Action required: 705 - Other - as specified
Due 12 July 2007
Resolved 12 July 2007
Stability › Severe Wind/Roll › General
Issued 21 March 2006
Resolved
Prove the CG MI that curtain installed on deck was either areplacement in kind or submit plans. If neither can be proved a stability test may be required.
Action required: 705 - Other - as specified
Resolved 28 April 2008
Construction/Loadline › Structures › Deck Plating
Issued 21 March 2006
Resolved
Submit plans for deck installation in Heads and bar area. Prove non combustioble or thinkness not greater tha.375. Also Need weights removed and installed.
Action required: 705 - Other - as specified
Resolved 28 April 2008
Stability › Severe Wind/Roll › General
Issued 21 March 2006
Resolved
vessel made unauthorized modifications to 3rd deck bar area. Ply wood used in construction must be removed.
Action required: 705 - Other - as specified
Resolved 28 April 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 February 2006
Resolved
Prove safety of loading and unloading passengers because of sunken mooring barge.
Action required: 705 - Other - as specified
Resolved 23 March 2006
Resolution: Seaworthiness still in question Issued COTP 017-06 for pumps onboard and and inspecting internal prior to laodin pax.
Construction/Loadline › Structures › Door
Issued 12 April 2005
Resolved
Properly remove paint from knife edges on water tight doors.
Due 19 April 2005
Resolved 15 April 2005
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 12 April 2005
Resolved
Properly rig anchor system to be able to properly release prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2005
Resolved 15 April 2005
Engineering › Fuel Oil Service System › Hose
Issued 12 April 2005
Resolved
Properly double clamp all engine fuel lines prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2005
Resolved 15 April 2005
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 12 April 2005
Resolved
Properly repair exhaust leak on AUX generator.
Due 19 April 2005
Resolved 15 April 2005
Engineering › Bilge Water Management System › Strainer
Issued 12 April 2005
Resolved
Properly repair bilge suction strainer screens prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2005
Resolved 15 April 2005
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 12 April 2005
Resolved
Properly submit plans to properly stow 2nd deck life jackets.
Due 22 April 2005
Resolved 30 May 2006
Resolution: Completed
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 12 April 2005
Resolved
Properly submit plans and fire load calculations for 3rd deck bar.
Due 26 April 2005
Resolved 30 May 2006
Resolution: Bar and wood removed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 April 2005
Resolved
Properly secure electrical wires in the 3rd deck bar prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2005
Resolved 15 April 2005
Electrical › Electrical Distribution System (service) › Panelboard
Issued 12 April 2005
Resolved
Properly label breakers in electrical distribution box on 2nd deck.
Due 19 April 2005
Resolved 15 April 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 12 April 2005
Resolved
Prove proper operation of all 2nd deck fans/light fixtures prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2005
Resolved 15 April 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 12 April 2005
Resolved
Properly wire neon signs on second deck.
Due 19 April 2005
Resolved 15 April 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 April 2005
Resolved
Provide proper first aid kit prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2005
Resolved 15 April 2005
Electrical › Electric Supply System (service) › Battery Installation
Issued 12 April 2005
Resolved
Replace grounding wire on starting (engine) battery system prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2005
Resolved 15 April 2005
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 12 April 2005
Resolved
Replace all hose clamps on marine sanitation device, type II prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2005
Resolved 15 April 2005
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 12 April 2005
Resolved
Properly bolt down main air compressor prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2005
Resolved 15 April 2005
Engineering › Fuel Oil Service System › Piping
Issued 12 April 2005
Resolved
Properly hard pipe fuel line and install shut off valve on main generator system prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2005
Resolved 15 April 2005
Personnel › Training
Issued 29 April 2002
Resolved
Establish crew training log book. LEGACY COMPONENT DESC: Familiarization Training
Action required: 705 - Other - as specified
Due 24 May 2002
Resolved 4 June 2002
Operations/Management › Drills/Instruction
Issued 29 April 2002
Resolved
Record all drills in bridge log. LEGACY COMPONENT DESC: Fire
Action required: 705 - Other - as specified
Due 4 June 2002
Resolved 4 June 2002
Stability
Issued 29 April 2002
Resolved
Mark upper deck for maximum number of passengers.
Action required: 705 - Other - as specified
Due 24 May 2002
Resolved 4 June 2002
Fire Fighting › Miscellaneous Items
Issued 29 April 2002
Resolved
Create fire control plan.
Action required: 705 - Other - as specified
Due 24 May 2002
Resolved 4 June 2002
Resolution: Requirement non-applicable
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 29 April 2002
Resolved
Label all lifejackets with vessel name.
Action required: 705 - Other - as specified
Due 24 May 2002
Resolved 29 April 2002
Resolution: All jackets labeled properly.
Operations/Management › Drills/Instruction
Issued 29 April 2002
Resolved
Create emergency evacuation plan. LEGACY COMPONENT DESC: Fire
Action required: 705 - Other - as specified
Due 24 May 2002
Resolved 4 June 2002
Resolution: requirement non-applicable
Engineering › Bilge Water Management System › Manifold
Issued 29 April 2002
Resolved
Prove proper operation of bilge pump and system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2002
Resolved 29 April 2002
Resolution: Bilge line repaired.
Construction/Loadline › Penetrations
Issued 13 March 2002
Resolved
Through-bulkhead fitting shall be capped off and sealed in the forward center compartment on the aft-starboard side bulkhead. LEGACY COMPONENT DESC: Thru-blkhd fitting
Condition: Improper/Lack of Maintenance
Due 15 April 2002
Resolved 15 March 2002
Resolution: Pipe capped and sealed
Construction/Loadline › Structures
Issued 13 March 2002
Resolved
Weld gouge in forward overhead deck channel in forward portside compartment. LEGACY COMPONENT DESC: Overhead deck channel
Condition: Improper Installation
Due 15 April 2002
Resolved 15 March 2002
Resolution: Gouge rewelded and repaired.
Construction/Loadline › Structures
Issued 13 March 2002
Resolved
Permanently repair fracture in transverse stringer in starboard-center compartment. LEGACY COMPONENT DESC: Transverse Deck Stringer
Condition: Improper/Lack of Maintenance
Due 15 April 2002
Resolved 15 March 2002
Resolution: Fracture was welded and repaired.
Engineering › Shafting/Propeller Arrangements
Issued 13 March 2002
Resolved
Replace portside cutlass bearing LEGACY COMPONENT DESC: Stern Tube Bearing
Condition: Damaged By Earlier Event
Due 15 April 2002
Resolved 15 March 2002
Resolution: Replaced.
Engineering › Steering Gear System › Rudder Stock
Issued 13 March 2002
Resolved
Make proper repairs to starboar side rudder, ensuring rudder is straight.
Condition: Damaged By Earlier Event
Due 15 April 2002
Resolved 15 March 2002
Resolution: Rudder straightened.
Fire Fighting
Issued 20 April 2001
Resolved
REPAIR FIRE PUMP TO PROVIDE WATER PRESSURE AND VOLUME AS PER 46 CFR 118.300(50 PSI). UNTIL PUMP IS REPAIRED A PORTABLE FIRE PUMP SHALL BE ONBOARD.
Condition: Unknown
Due 20 April 2001
Resolved 20 April 2001
Lifesaving
Issued 20 April 2001
Resolved
REPLACE 15 ADULT LIFEJACKETS TO BRING THE TOTAL TO 437. REDUCE THE NUMBER OF PASSENGERS ALLOWED BY 15 UNTIL PFD'S REPLACED.
Condition: Unknown
Due 20 April 2001
Resolved 20 April 2001
Construction/Loadline
Issued 6 April 2000
Resolved
Repair all Bulkhead penetrations as necessary
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Fire Fighting
Issued 6 April 2000
Resolved
Install fire pump pressure guage
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Accommodation/Occupational Safety
Issued 6 April 2000
Resolved
properly clean and remove garbage from room aft of pilot house
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Lifesaving
Issued 6 April 2000
Resolved
replace condemned life jackets, passenger count reduced by 28 until proof of replacement shown to attending marine Inspector.
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Navigation
Issued 6 April 2000
Resolved
Properly label shut-off valve on air receiver for vessel horn
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Fire Fighting
Issued 6 April 2000
Resolved
Relabel 01 deck fire station
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Fire Fighting
Issued 6 April 1999
Resolved
REPLACE OR REPAIR 5 GPM HANDPUMP.
Condition: Unknown
Due 7 April 1999
Resolved 14 April 1999
Electrical
Issued 6 April 1999
Resolved
REPLACE MISSING LIGHT GUARDS AND LIGHT BULBS ON THE SECOND DECK.
Condition: Unknown
Due 14 April 1999
Resolved 14 April 1999
Fire Fighting
Issued 6 April 1999
Resolved
RELABEL FADED FIRE STATION NUMBERS._x001C_
Condition: Unknown
Due 14 April 1999
Resolved 14 April 1999
Electrical
Issued 6 April 1999
Resolved
INSTALL CONTAINMENT BELOW GENERATOR ON THE STERN TO PREVENT FUEL/LUBE OIL FROM GETTING INTO THE NAV WATERS OF THE U.S.
Condition: Unknown
Due 6 April 1999
Resolved 6 April 1999
Construction/Loadline
Issued 6 April 1998
Resolved
MAKE BLKHD CONNECTION WATERTIGHT FORWARD OF ENGINEROOM.
Condition: Unknown
Due 7 April 1998
Resolved 28 April 1998
Engineering
Issued 6 April 1998
Resolved
RPLACE 40X40 FLAMESCREEN MESH WITH 30X30 MESH.
Condition: Unknown
Due 7 April 1998
Resolved 28 April 1998
Engineering
Issued 6 April 1998
Resolved
REPAIR PORT ENGINE TACH PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 7 April 1998
Resolved 28 April 1998
Lifesaving
Issued 27 March 1996
Resolved
PROVIDE SEPARATE STOWAGE AREA FOR CHILD LIFE JACKETS.
Condition: Unknown
Due 27 March 1996
Resolved 27 March 1996
Fire Fighting
Issued 27 March 1996
Resolved
RPOVIDE PROPER FIRE HOSE (1 1/2 INCH) ON THREE FIRE STATIONS.
Condition: Unknown
Due 27 June 1996
Resolved 16 April 1996
Lifesaving
Issued 27 March 1996
Resolved
MARK LIFE JACKET NUMBER ON STOWAGE AREA.
Condition: Unknown
Due 27 March 1996
Resolved 27 March 1996
Fire Fighting
Issued 27 March 1996
Resolved
PROVIDE COMBINATION SOLID STREAM AND WATER SPRAY FIRE HOSE NOZZLE AT EACH STATION.
Condition: Unknown
Due 27 June 1996
Resolved 16 April 1996
Fire Fighting
Issued 27 March 1996
Resolved
PROVIDE PRESSURE GAGE TO DISCHARGE SIDE OF FIRE PUMP.
Condition: Unknown
Due 27 June 1996
Resolved 16 April 1996
Fire Fighting
Issued 27 March 1996
Resolved
PROVIDE RELIEF VALVE IF PUMP EXCEEDS 150 PSI ON FIRE PUMP.
Condition: Unknown
Due 27 June 1996
Resolved 16 April 1996
Engineering
Issued 27 March 1996
Resolved
REPLACE FLAME SCREENS ON FUEL TANK.
Condition: Unknown
Due 27 March 1996
Resolved 27 March 1996
Construction/Loadline
Issued 27 March 1996
Resolved
CUT OFF RETAINING CLIPS ON WATER TIGHT DOORS BELOW DECKS.
Condition: Unknown
Due 27 March 1996
Resolved 27 March 1996
Lifesaving
Issued 27 March 1996
Resolved
REPLACE PLASTIC TRASH CANS WITH NON-COMBUSTIBLE TRASH CANS.
Condition: Unknown
Due 27 March 1996
Resolved 27 March 1996
Navigation
Issued 27 March 1996
Resolved
PROVIDE PROPER STERN LIGHT PRIOR TO NIGHTTIME OPERATIONS.
Condition: Unknown
Due 27 March 1996
Resolved 27 March 1996
Electrical
Issued 30 March 1995
Resolved
IMPROPER USE OF EXTENSION CORD HANGING IN OVERHEAD. REMOVE FROM VESSEL.
Condition: Unknown
Due 11 April 1995
Resolved 11 April 1995
Electrical
Issued 6 April 1994
Resolved
RELABEL THE SWITCHBOARD FOR THE SERVICE GENERATOR.
Condition: Unknown
Due 6 April 1994
Resolved 18 April 1994
Lifesaving
Issued 6 April 1994
Resolved
REPLACE WATERLIGHT ON RING BOUY
Condition: Unknown
Due 6 April 1994
Resolved 18 April 1994
Lifesaving
Issued 6 April 1994
Resolved
REPLACE OR REPAIR FLARE BOX
Condition: Unknown
Due 6 April 1994
Resolved 18 April 1994
Electrical
Issued 6 April 1994
Resolved
REPLACE MISSING METAL GUARDS AROUND THE LIGHTS
Condition: Unknown
Due 6 April 1994
Resolved 18 April 1994
Electrical
Issued 6 April 1994
Resolved
REMOVE DROP LIGHTS FROM OVERHEAD.
Condition: Unknown
Due 6 April 1994
Resolved 18 April 1994
Engineering
Issued 20 May 1993
Resolved
DOUBLE CLAMP ALL MAIN ENGINE AND GENERATOR JACKET WATER AND FUEL HOSES.
Condition: Unknown
Due 20 June 1993
Resolved 14 June 1993
Electrical
Issued 20 May 1993
Resolved
INSTALL SAFETY GUARD OVER GENERATOR PULLEYS.
Condition: Unknown
Due 20 June 1993
Resolved 14 June 1993
Lifesaving
Issued 19 May 1992
Resolved
PROVIDE SIX DAYTIME AND SIX NIGHT DISTRESS SIGNALS.
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Lifesaving
Issued 1 May 1991
Resolved
Provide onboard 12 additional Type I Adult PFD's._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Electrical
Issued 28 April 1989
Resolved
REPAIR FREQUENCY METER FOR THE SHIPS SERVICE GENERATOR.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Lifesaving
Issued 28 April 1989
Resolved
NEW TO BE INSTALLED LIFE JACKET STOWAGE SHALL COMPLY WITH 46 CFR 180.25-10
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Accommodation/Occupational Safety
Issued 28 April 1989
Resolved
REMOVE ALL COMBUSTIBLE MATERIALS FROM THE BELOW DECK COMPARTMENTS; TO INCLUDE: WOOD, FLAMABLE LIQUIDS, PAPER PRODUCTS, ETC..
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Lifesaving
Issued 28 April 1989
Resolved
PROVIDE 25 ADULT LIFE JACKETS-TOTAL PERSON ALLOWED SHALL NOT EXCEED 275 UNTIL CORRECTED.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Fire Fighting
Issued 28 April 1989
Resolved
MOUNT ALL FIRE PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Fire Fighting
Issued 28 April 1989
Resolved
PROVIDE BILGE STRAINERS FOR BILGE SUCTION LINES IN ACCORDANCE WITH 46 CFR 182.5. REPAIR/REPLACE LEAKING BILGE MANIFOLD VALVES.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Fire Fighting
Issued 28 April 1989
Resolved
PROVIDE PORTABLE HAND FIRE/BILGE PUMP IN ACCORDANCE WITH 46 CFR 181.10-5
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Fire Fighting
Issued 28 April 1989
Resolved
INSTAL FIRE STATIONS ON THE O2 AND 03 DECKS AND EQUIP WITH SUITABLE HOSE AND NOZZLE.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Engineering
Issued 28 April 1989
Resolved
INSTAL REMOTE FUEL OIL SHUT OFF VALVE. SHUT OFF VALVES SHALL BE FITTED IN THE SUPPLY LINE, ONE AT THE TANK CONNECTION AND ONE AT THE ENGINE END. THE FUEL OIL VALVE AT THE TANK SHALL BE OPERABLE FROM OUTSIDE THE TANK COMPARTMENT(46CFR182.20-40(B)(3).
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Electrical
Issued 28 April 1989
Resolved
PROVIDE BATTERY BOX COVER.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Documentation
Issued 28 April 1989
Resolved
PROVIDE VALID FCC LICENSE.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Navigation
Issued 28 April 1989
Resolved
PROVIDE 12 CG APPROVED DISTRESS FLARES AND A SUITABLE WATERPROOF CONTAINER 46 CFR 180.35
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Fire Fighting
Issued 20 February 1987
Resolved
PROVIDE UPGRADING OF FIRE PROTECTION SYSTEM AS OUTLINED IN [name withheld] LETTER DATED 20 FEBRUARY 1987. IF THE AFOREMENTIONED IS NOT COMPLETED PRIOR TO 01MAR88 THE TOTAL PERSONS ALLOWED WILL BE REDUCED TO 150.
Condition: Unknown
Due 20 February 1987
Resolved 20 February 1987
Electrical
Issued 15 July 1986
Resolved
REMOVE EXISTING FUEL SUPPLY LINE AND FUEL TANK FOR GAS GENERATOR IN SPACE OVER RUDDERS AND REPLACE WITH APPROVED TANK AND FUEL LINE.
Condition: Unknown
Due 15 July 1986
Resolved 15 July 1986