← All vessels
ASIAN GLORY
ASIAN GLORY is a 1995 freight ship. The Coast Guard has recorded 18 inspections since 1999, most recently in September 2011, along with 9 deficiencies and 4 operational controls, 1 with no removal date recorded.
Records from 1999 to 2011. Most recent: inspection, 18 September 2011.
- Built
- 1995
- Last inspected
- 18 September 2011
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 0 without a recorded resolution
- Controls
- 1 with no removal date recorded
Identity
9113329 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9VUE
451262
Flag
SINGAPORE
—
Maury page id
psix-451262
Inspections, by type
…with no type recorded9
Years with a record
10 calendar years (1999–2011)
The 18 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it14814 - Simplified, Net Ton
26341 - Simplified, Gross Ton
26341 - Convention (Subpart B), Gross Ton
45194 - Dead Weight, Ton
53175 - Displacement, Ton
26341 - Simplified, Gross Ton
26341 - Convention (Subpart B), Gross Ton
45194 - Dead Weight, Ton
53175 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 18
18 September 2011
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4146390
7 February 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3677498
17 March 2009
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3434545
20 September 2008
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3328726
18 September 2008
ISPS I Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3327494
18 September 2008
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3327874
25 October 2007
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3090056
23 October 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3085631
19 October 2007
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3082952
12 March 2007
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2886636
10 March 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2885233
24 October 2006
MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2806667
15 April 2006
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2625327
14 March 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2602007
25 August 2005
PII Safety Exam · ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2474315
5 October 2003
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1921559
17 February 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 287159
16 July 1999
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 430320
Deficiency record · 9
Fire Fighting › Remote Fuel Shutoff › General
Issued 19 October 2007
Resolved
Emergency generator fuel storage tank with 1 m3 (1,000 L) capacity is not fitted with a cork or value directly on the tank capable of being closed from a safe position outside the space in the event of a fire. SOLAS(1997 consolidated) Ch II-2/Reg 15.2.5 .
Documentation › Logs/Records › Oil Record Book
Issued 24 October 2006
Resolved
Oil Record book was missing dates and signatures.
Operations/Management › Pollution › Control of Garbage
Issued 24 October 2006
Resolved
Mixed garbage in the engine room. Black cans are disginated for oil rags and the green cans are for metal, paper and glass. Plastic items were found in both.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 24 October 2006
Resolved
Provide non-slip surface in steering room.
Lifesaving › Launching Appliances › Davit
Issued 24 October 2006
Resolved
Several sheaves found without grease. Grease fittings found painted over.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 24 October 2006
Resolved
Smoke and heat detectors, must provide guidance on proper testing on accordance with NOHMI NO S-322D. Crew is currently testing equipment with a cigarette lighter and a smoldering oily rag.
Personnel › Training › Fire Fighting Basic
Issued 24 October 2006
Resolved
Failed first fire drill- crew entered space without any protective/ fire fighting equipment.
Fire Fighting › Means of Escape › Blocked
Issued 24 October 2006
Resolved
Conflict between safety and security. Door to steering flat had a bar on inside prohibiting entrance form outside in case of emergency, ISPS "A" 8, reference "B" 8.10-1.
Accommodation/Occupational Safety
Issued 16 July 1999
Resolved
MSD WAS NOT SECURED. 33 CFR 159.7.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.