MAURY USCG vessel records
← All vessels

MASTER CODY

Built
1944
Last inspected
11 January 2001
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 11 January 2001
…with no type recorded10
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 3 calendar years (1986–2001)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

6419497
Flag
UNITED STATES
Tonnage
593 - Regulatory (Subpart C or D), Gross Ton 579 - Convention (Subpart B), Gross Ton 324 - Regulatory (Subpart C or D), Net Ton 174 - Convention (Subpart B), Net Ton 753 - Dead Weight, Ton
Maury page id
psix-45128
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 11

11 January 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 189271
11 January 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 767374
9 January 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 189272
9 January 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 285895
9 January 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 767274
5 November 2000 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 283605
19 June 2000 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 530748
4 March 2000 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 275928
23 February 2000 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 274981
13 November 1986 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1332049
24 September 1986 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1016570

Deficiency record · 25

Accommodation/Occupational Safety
Issued 9 January 2001 Resolved
OVERBOARD SEWAGE VALVE HAD BEEN LEFT OPEN. RAW SEWAGE WAS FLOWING OVERBOARDINTO ESTUARY. _x001C_ _x001C_ 33CFR159.7
Condition: Unknown
Due 9 January 2001
Resolved 9 January 2001
Construction/Loadline
Issued 5 November 2000 No resolution recorded
Repair damaged railings and ladder to the satisfaction of class prior to 05DEC00, ILLC 66, Annex I/15.
Condition: Unknown
Due 5 December 2000 — due date passed with no resolution recorded
Documentation
Issued 5 November 2000 Resolved
Provide valid Safe Manning Document prior to departure IAW SOLAS 74/78, Ch.1, Reg.19.
Condition: Unknown
Due 6 November 2000
Resolved 14 November 2000
Lifesaving
Issued 23 February 2000 Resolved
Repair or replace pressure relief valve on aux air compressor prior to nextU.S. Port. SOLAS 60 I/11.
Condition: Unknown
Due 5 March 2000
Resolved 10 March 2000
Navigation
Issued 23 February 2000 Resolved
Provide deviation table for the magnetic compass prior to next U.S. Port. SOLAS 74/78 V/12(b)
Condition: Unknown
Due 5 March 2000
Resolved 10 March 2000
Lifesaving
Issued 23 February 2000 Resolved
Repair aft port lifebuoy light prior to next U.S. Port. SOLAS 60 III/21
Condition: Unknown
Due 5 March 2000
Resolved 10 March 2000
Lifesaving
Issued 23 February 2000 Resolved
Provide one additional line throwing appliance, making 4 total prior to next U.S. Port. SOLAS 60 II/56(h)
Condition: Unknown
Due 6 March 2000
Resolved 10 March 2000
Navigation
Issued 23 February 2000 Resolved
Conduct and log emergency steering drills at least every 3 months. SOLAS 74/78 V/19
Condition: Unknown
Due 27 June 2000
Resolved 27 June 2000
Engineering
Issued 23 February 2000 Resolved
Provide and post pollution placard prior to next U.S. Port. 33 CFR 155.450
Condition: Unknown
Due 6 March 2000
Resolved 10 March 2000
Fire Fighting
Issued 23 February 2000 Resolved
Provide a total of two complete fireman outfits prior to departure. SOLAS II-2/17.2 and 17.3
Condition: Unknown
Due 23 February 2000
Resolved 10 March 2000
Accommodation/Occupational Safety
Issued 23 February 2000 Resolved
Provide and post a MARPOL V pollution placard prior to next U.S. Port. MARPOL V/9
Condition: Unknown
Due 5 March 2000
Resolved 10 March 2000
Engineering
Issued 23 February 2000 Resolved
Repair or remove inoperative aux hot water boiler prior to next U.S. Port. SOLAS 60 I/11.
Condition: Unknown
Due 27 June 2000
Resolved 27 June 2000
Engineering
Issued 23 February 2000 Resolved
Provide at least 5 gallon portable containment at each fill manifold and tank vent prior to bunkering. 33 C.F.R. 155.320
Condition: Unknown
Due 23 February 2000
Resolved 10 March 2000
Construction/Loadline
Issued 23 February 2000 Resolved
Crop and renew as original the wasted deck plate in way of steering gear hatch prior to next U.S. Port. SOLAS 60 I/11
Condition: Unknown
Due 27 June 2000
Resolved 27 June 2000
Electrical
Issued 23 February 2000 Resolved
Install safety guards on all lighting fixtures throughout the vessel prior to next U.S. Port. SOLAS 60 I/11
Condition: Unknown
Due 27 June 2000
Resolved 27 June 2000
Fire Fighting
Issued 23 February 2000 Resolved
Repair or replace leaking fire hydrant valves located on the main deck prior to next U.S. Port. SOLAS 60 II/56(E)ii
Condition: Unknown
Due 27 June 2000
Resolved 27 June 2000
Fire Fighting
Issued 23 February 2000 Resolved
Replace rotted fire control plans and store in weather tight containers on the port and starboard weather deck prior to next U.S. Port. SOLAS 74 ammended II-2/20.2
Condition: Unknown
Due 5 March 2000
Resolved 10 March 2000
Engineering
Issued 23 February 2000 Resolved
Remove or replace non-approved plastic hoses in the engine room prior to next U.S. Port. SOLAS 60 I/11
Condition: Unknown
Due 27 June 2000
Resolved 27 June 2000
Fire Fighting
Issued 23 February 2000 Resolved
Provide an Internatonal Shore Connection prior to next U.S. Port. SOLAS 60II/56(h)
Condition: Unknown
Due 27 June 2000
Resolved 27 June 2000
Lifesaving
Issued 23 February 2000 Resolved
Provide and maintain a log recording weekly and monthly lifesaving equipment maintenance and checks prior to next U.S. Port. SOLAS 74/78 III/19
Condition: Unknown
Due 27 June 2000
Resolved 27 June 2000
Documentation
Issued 23 February 2000 Resolved
Provide Minimum Safe Manning Certificate and ensure vessel is manned in accordance with Minimum Safe Manning Certificate. SOLAS 74/78 V/13
Condition: Unknown
Due 23 February 2000
Resolved 10 March 2000
Documentation
Issued 23 February 2000 Resolved
Provide Shipboard Oil Pollution Emergency Plan prior to bunkering and departure. MARPOL I/26, 33 CFR 151.29
Condition: Unknown
Due 23 February 2000
Resolved 10 March 2000
Electrical
Issued 23 February 2000 Resolved
Repair or replace all dead end wires, improper electrical connections, and ensure electrical equipement is installed properly by next U.S. Port._x001C_ SOLAS 60 II/27
Condition: Unknown
Due 27 June 2000
Resolved 27 June 2000
Engineering
Issued 23 February 2000 Resolved
Provide oil transfer procedures prior to bunkering. 33 CFR 155.720
Condition: Unknown
Due 23 February 2000
Resolved 10 March 2000
Navigation
Issued 23 February 2000 Resolved
Provide Sailing Directions, Light List, Tide Tables and Tidal Current Tables for Hawaii prior to departure. SOLAS 74/78 V/20
Condition: Unknown
Due 23 February 2000
Resolved 10 March 2000

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.