Records from 1996 to 2023. Most recent: inspection, 16 November 2023.
Inspection history · 53
16 November 2023
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7825591
25 July 2023
Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7754446
23 April 2023
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7675055
28 July 2022
Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7518302
3 June 2022
Type not recorded
No type recorded · Station Apra Harbor · USCG Oceania District (CGD-O) · Activity 7467796
22 November 2021
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7358294
7 September 2021
Drydock Exam · In-Service Inspection · Internal Structural Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7305940
2 August 2021
Deficiency Check · In-Service Inspection · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7274820
23 July 2020
Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7013656
23 June 2020
Administrative Inspection · In-Service Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6984289
10 February 2020
Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 6905887
8 January 2020
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6884769
26 September 2019
Deficiency Check · Internal Structural Exam · In-Service Inspection · Administrative Inspection · Drydock Exam · Examination of Repairs
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6821334
23 April 2019
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6668169
11 October 2018
Examination of Repairs · Drydock Exam · Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6558052
11 July 2018
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6476164
30 April 2018
Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6402142
30 October 2017
Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6299293
3 August 2017
Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6229062
19 October 2016
Deficiency Check · Annual Inspection · Hull Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6017169
2 June 2016
Drydock Exam · Examination of Repairs · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5894640
21 April 2016
Internal Structural Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5859046
13 August 2015
Type not recorded
No type recorded · Station Apra Harbor · USCG Oceania District (CGD-O) · Activity 5215501
24 January 2011
Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3933985
23 January 2010
Drydock Exam · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3668764
15 January 2009
Drydock Exam · Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3393656
21 January 2008
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3133976
28 February 2007
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2878849
25 January 2007
Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2860777
22 March 2006
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2606887
23 February 2006
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2590300
23 January 2006
Hull Examination · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2571107
27 September 2005
Damage Survey
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2503482
7 January 2005
Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2271674
22 January 2004
Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2002631
1 April 2003
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1766173
29 January 2003
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1737304
23 January 2003
Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1734144
15 March 2002
Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1616379
12 March 2002
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1492939
28 February 2002
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1490303
13 April 2001
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1062521
24 January 2001
MARPOL Annex V Examination · Hull Examination · COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1376440
25 February 2000
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1046456
26 January 2000
MARPOL Annex V Examination · Re-Inspection · Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1397334
22 March 1999
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1340803
14 January 1999
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1372475
30 May 1998
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 802558
9 February 1998
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1126837
3 February 1998
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1106734
26 January 1998
COI Inspection · Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 780080
9 July 1997
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 777652
31 December 1996
Hull Examination · Initial Certification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1406029
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 July 2022
Resolved
The design of all exhaust systems must ensure minimum risk of injury to personnel. Major exhaust leak was identified coming from the exhaust inlet to the turbo.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 July 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 July 2022
Resolved
A vessel is inspected for compliance with the standards required by this chapter. Arrangements not covered by standards in this sub-chapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Leak identified on the starboard bow portion of the inflatable sponson.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2022
Resolved 10 August 2022
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 3 October 2021
Resolved
A vessel must comply with the applicable requirements for any radio and EPIRB installations. Vessels operating beyond 1,000 ft from shore but less than 20nm are required to have one (01) VHF radio. VHF radio was found to be inoperable, vessel is restricted to operations no more than 1,000 ft from shore.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 October 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 2 August 2021
Resolved
There must be a means of accurately determining the amount of fuel in each tank either by sounding through a separate sounding pipe or a fill pipe or by an installed marine type fuel gauge. The installed marine type fuel gauge for the fuel oil tank was not operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 August 2021
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 2 August 2021
Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. The medical certificate will be issued for various periods of time based upon the endorsements the mariner holds. crew member on board was unable to provide proof of a valid medical certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 August 2021
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 2 October 2019
Resolved
Starboard bow seam leak from previous repair.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 January 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 April 2019
Resolved
Install visual indicating light at the operating station for the automatic actuation for the engine compartment electric submersible pump. 46 CFR 182.530(c)
Action required: 705 - Other - as specified
Due 8 May 2019
Resolved 7 May 2019
Resolution: Light installed and tested, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 April 2019
Resolved
Visual indicator at the operating station for the bilge high level alarm was not functioning. Repair indicator. 46 CFR 182.530(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2019
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 April 2019
Resolved
Replace the battery in the life ring buoy floating water light with expiration date of 2015. 46 CFR 185.726(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2019
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 30 April 2019
Resolved
Effect repairs to the outdrive steering cables through hull fitting, fitting currently installed is allowing the ingress of sea water in the engine compartment. 46 CFR 320(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2019
Resolution: Corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 30 April 2019
Resolved
Renew engine compartment gaskets to the vessels transom to mitigate the potential for water ingress and down flooding. 46 CFR 360
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 May 2019
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 April 2019
Resolved
Replace ring life buoy, life ring is currently multi colored with one side orange and the opposite side white, regulations only allows for a white or an orange life ring buoy for the vessels route. 46 CFR 180.70
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2019
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 April 2019
Resolved
Effect repairs to the fuel oil leak on the injector fitting for the #5 main engine cylinder. 46 CFR 182.100
Action required: 10 - Deficiency Rectified
Resolved 30 April 2019
Resolution: Corrected on the spot
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical first aid
Issued 30 April 2019
Resolved
Provide proof of at least 50% of the crew having current first aid/CPR training. NVIC 1-91
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 May 2019
Resolution: Vefifed first aid/CPR training for vessel crew.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 April 2019
Resolved
Install 60' of non-kinking line for the ring life buoy, installed line is approximately 40'. 180.709(c)(2)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 May 2019
Resolution: Corrected.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 7 May 2018
Resolved
The M/E enclosure has holes penetrating the starboard side which would reduce the fixed firefighting system's effectiveness.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 7 May 2018
Resolved 7 May 2018
Resolution: The holes were covered with aluminum plate.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 30 April 2018
Resolved
Annual fire fighting service report was not available for marine inspector. Provide annual servicing report for the fire-boy system installed near the main engine.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2018
Resolved 7 May 2018
Resolution: Vessel rep emailed fire boy service report for 2018.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 30 April 2018
Resolved
Vessel has newly installed VHF radio / call sign that has not been verified by an FCC approved tech. Have FCC approved tech verify newly installed VHF and issue new safety radiotelephony cert.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2018
Resolved 23 May 2018
Documentation › Certificates/Documents › Certificate of Number (state)
Issued 3 August 2017
Resolved
Provide valid Guam registration.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 August 2017
Resolved 8 August 2017
Communications › Radio Communications › EPIRB
Issued 3 August 2017
Resolved
Provide current EPIRB NOAA registration.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 August 2017
Resolved 8 August 2017
Construction/Loadline › Hull › Hull Plating
Issued 3 August 2017
Resolved
Conduct Annual Overpressure Test of Inflatable Hull.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 August 2017
Resolved 8 August 2017
Navigation › Piloting/Steering › Coast Guard Light List
Issued 3 August 2017
Resolved
Provide 2017 USCG Light Light
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 August 2017
Resolved 8 August 2017
Navigation › Piloting/Steering › US Coast Pilot
Issued 3 August 2017
Resolved
Provide 2017 Coast Pilot
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 August 2017
Resolved 8 August 2017
Navigation › Piloting/Steering › Marine Charts
Issued 3 August 2017
Resolved
Provide up to date navigation chart.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 August 2017
Resolved 8 August 2017
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 3 August 2017
Resolved
Provide current tide tables.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 August 2017
Resolved 8 August 2017
Engineering › Fuel Oil Service System › Valve, Control
Issued 3 August 2017
Resolved
Prove proper operation of fuel shutoff valve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 August 2017
Resolved 8 August 2017
Communications › Radio Communications › VHF Radiotelephone
Issued 3 August 2017
Resolved
Enter vessel MMSI number into VHF radio.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 1 October 2017
Documentation › Certificates/Documents › FCC SSL
Issued 3 August 2017
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 1 October 2017
Operations/Management › Vessel Activity › Other
Issued 3 August 2017
Resolved
Provide proof of user fee payment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 August 2017
Resolved 8 August 2017
Communications › Alarms/Indicators › Bilge Alarm
Issued 20 October 2016
Resolved
Prove proper operation of high water level visual alarm.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2016
Resolved 21 October 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 October 2016
Resolved
Provide proper navigation lighting.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2016
Resolved 21 October 2016
Navigation › Piloting/Steering › Marine Charts
Issued 20 October 2016
Resolved
Provide updated marine chart.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2016
Resolved 21 October 2016
Navigation › Piloting/Steering › Coast Guard Light List
Issued 20 October 2016
Resolved
Provide updated CG light list.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2016
Resolved 21 October 2016
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 20 October 2016
Resolved
Properly mark adult and child life jacket stowage locations.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 25 October 2016
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 20 October 2016
Resolved
Prove scientific method of random drug testing of crew members.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 January 2017
Resolved 25 October 2016
Documentation › Certificates/Documents › FCC SSL
Issued 20 October 2016
Resolved
Provide SB FCC Ship Station license and updated Safety Cert.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 25 October 2016
Communications › Radio Communications › VHF Radiotelephone
Issued 20 October 2016
Resolved
Install MMSI number in DSC-VHF radio after receiving new FCC Ship Station license.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 25 October 2016
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 23 January 2010
Resolved
Reject (3) adult type I life jackets due to deteriorated float material. Replace rejected life jackets.
Action required: 705 - Other - as specified
Resolved 23 January 2010
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 23 January 2010
Resolved
Service date expired ( Jan 09 ). Provide a proof of current service/maintenance to all portable CO2s.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 January 2010
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 15 January 2009
Resolved
Provide proof of currency in first aid/cpr for 50% of crew IAW NVIC 1-91.
Action required: 705 - Other - as specified
Due 15 February 2009
Resolved 23 January 2009
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 15 January 2009
Resolved
Prove proper operation of audible alarm on the pre-engineered fixed fire extinguishing system IAW 46CFR181.420(b)(2).
Action required: 705 - Other - as specified
Due 15 February 2009
Resolved 2 February 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 January 2009
Resolved
Renew expired items in first aid kit IAW 46CFR184.710.
Action required: 705 - Other - as specified
Due 15 February 2009
Resolved 23 January 2009
Construction/Loadline › Hull › Hull Plating
Issued 15 January 2009
Resolved
Make permanent repairs to the internal bulkheads of the main tube. Provide written repair proposal prior to start of repairs.
Action required: 705 - Other - as specified
Due 7 August 2009
Resolved 10 November 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 January 2008
Resolved
Replace all expired items in first aid kit.
Action required: 705 - Other - as specified
Due 22 February 2008
Resolved 30 January 2008
Resolution: All expired items replaced.
Engineering › Bilge Water Management System › Interface Detector
Issued 25 January 2007
Resolved
Found visual bilge alarm not properly operating. Repair or replace visual bilge alarm.
Due 25 February 2007
Resolved 27 February 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 January 2007
Resolved
Found the first aid kit with expired asprin. Remove and replace espired asprin.
Due 25 February 2007
Resolved 27 February 2007
Navigation › Piloting/Steering › Marine Charts
Issued 25 January 2007
Resolved
Found the chart on board not up to date. Prove vessel's chart is current with corrections from the local notice to mariners.
Due 25 February 2007
Resolved 27 February 2007
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 23 January 2006
Resolved
Found lifebuoy retro-reflective material worn. Repair or replace retro-reflective material.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2006
Resolved 22 March 2006
Lifesaving › Lifefloat › Retroreflective Material
Issued 23 January 2006
Resolved
Found retro-reflective material on lifefloat worn. Repair or replace retro-reflective material.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2006
Resolved 22 March 2006
Engineering › Steering Gear System › Bracket/Clamp
Issued 23 January 2006
Resolved
Found vessel missing emergency steering. Prove ability to steer by secondary means.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 23 February 2006
Resolved 23 February 2006
Operations/Management › Equipment Service/Testing › EPIRB
Issued 23 January 2006
Resolved
Found EPIRB lanyard not attached to the vessel. Connect lanyard to vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 February 2006
Resolved 23 February 2006
Resolution: Witnessed proper connection.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 23 January 2006
Resolved
Found no date of installation for EPIRB hammer unit. Prove and mark hammer unit with expiration date.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 February 2006
Resolved 23 February 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 January 2006
Resolved
Found expired medical supply in medical locker. Replace supplies with in service materials.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2006
Resolved 23 February 2006
Engineering › Fuel Oil Service System › Valve
Issued 23 January 2006
Resolved
Found vessel missing emergency fuel shut off in way of engine. Prove emergency fuel oir shut down in way of main engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2006
Resolved 23 February 2006
Operations/Management › Equipment Service/Testing › EPIRB
Issued 7 January 2005
Resolved
PROVIDE LOG'S FOR DRILLS AND LIFESAVING EQUIPMENT INSPECTIONS
Due 14 January 2005
Resolved 10 January 2005
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 7 January 2005
Resolved
PROVE PROPER OPERATION OF BILGE HIGH WATER ALARM.
Due 14 January 2005
Resolved 10 January 2005
Construction/Loadline › Hull
Issued 23 January 2003
Resolved
Internal hull iwo operating station & immediately forward of same not available for inspection. Internal hull iwo these locations shall be made available for an ISE nlt 23Mar03 by a USCG marine inspector. If evidence of structural damage/sig. corrosion exists hull shall be repaired to sat. of CG
Action required: 705 - Other - as specified
Due 23 March 2003
Resolved 29 January 2003
Resolution: Cockpit and canopy removed to allow for access. No evidence of structural damage or significant corrosion.
Construction/Loadline › Hull
Issued 28 February 2002
Resolved
Weld fracture in bow area. Permanent repair required NLT 31Mar2002 by qualified welder using proven weld procedure. Post repair NDE required. Hull structure to be examined by USCG iwo of pontoons removed to facilitate repair. Vsl O/O to monitor condition daily & immediatly notify USCG if worsening. LEGACY COMPONENT DESC: Weld
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 March 2002
Resolved 12 March 2002
Resolution: Repair conducted by SeaFix Company. Post repair NDE (Dye Penetrant) conducted.
Fire Fighting
Issued 24 January 2001
Resolved
Prove the operation of all safeties and alarms for the pre-engineered fire fighting system.
Condition: Unknown
Due 24 January 2001
Resolved 24 January 2001
Lifesaving
Issued 26 January 2000
Resolved
Provide six Coast Guard approved hand held flares and six Coast Guard approved hand held smoke distress signals for the vessel.
Condition: Unknown
Due 26 January 2000
Resolved 26 January 2000
Fire Fighting
Issued 26 January 2000
Resolved
Prove the operation of the alarms and safeties for the fixed fire extinguishing system.
Condition: Unknown
Due 26 January 2000
Resolved 26 January 2000
Lifesaving
Issued 26 January 2000
Resolved
Prove the operation of the vessel's EPIRB. Vessel is restricted to no morethan three (3) miles from shore.
Condition: Unknown
Due 26 January 2000
Resolved 26 January 2000
Lifesaving
Issued 26 January 2000
Resolved
Provide and post a life jacket donning placard for the type of life jacketscarried on the vessel.
Condition: Unknown
Due 26 January 2000
Resolved 26 January 2000
Lifesaving
Issued 14 January 1999
Resolved
Obtain and post a life jacket donning placard for the style of life jacket carried on the vessel.
Condition: Unknown
Due 14 January 1999
Resolved 14 January 1999
Documentation
Issued 14 January 1999
Resolved
Obtain a FCC Marine Operator's permit for all vessel personnel that operatethe vessel's VHF radio.
Condition: Unknown
Due 14 January 1999
Resolved 14 January 1999
Documentation
Issued 14 January 1999
Resolved
Obtain a valid FCC Safety RadioTelephony certificate for the vessel.
Condition: Unknown
Due 14 January 1999
Resolved 14 January 1999
Lifesaving
Issued 26 January 1998
Resolved
CONDUCT MAN OVERBOARD DRILLS, FIREFIGHTING DRILLS, MONTHLY EPIRB TESTS, ANDSURVIVAL CRAFT MAINTENANCE, AND PROVIDE EVIDENCE OF LOGGING PER 46 CFR 185.520/185.524/185.728/185.702 RESPECTIVELY. NO EVIDENCE WAS PROVIDED AT INSPECTION.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Unknown
Issued 26 January 1998
Resolved
PROVIDE PROOF OF SATISFACTORY PASSENGER COUNT PROCEDURE PER 46 CFR 185.504.AT TIME OF INSPECTION THERE WAS NO EVIDENCE OF ESTABLISHED PROCEDURE.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Unknown
Issued 26 January 1998
Resolved
PROVIDE EVIDENCE OF PASSENGER SAFETY ORIENTATION BRIEFS BEING CONDUCTED AT EACH VOYAGE PER 46 CFR 185.506. NO EVIDENCE WAS PROVIDED AT INSPECTION.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Documentation
Issued 26 January 1998
Resolved
PROVIDE APPLICATION FOR INSPECTION PER 46 CFR 176.105. NONE PRESENTED PRIOR TO OR DURING INSPECTION.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Documentation
Issued 26 January 1998
Resolved
POST CERTIFICATE OF INSPECTION PER 46 CFR 176.302. COI WAS NOT POSTED AT TIME OF INSPECTION.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Documentation
Issued 26 January 1998
Resolved
PROVIDE FCC SAFETY CERTIFICATE PER 47 CFR 80. NONE PROVIDED DURING INSPECTION.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Documentation
Issued 26 January 1998
Resolved
PROVIDE STABILITY LETTER PER 46 CFR 176.306. THERE WAS NO EVIDENCE OF A STABILITY LETTER AT INSPECTION.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Construction/Loadline
Issued 26 January 1998
Resolved
INSTALL ENGINE SEA WATER COOLANT SUCTION PIPE SHUT OFF VALVE ADJACENT TO THROUGH HULL SPOOL PIECE PER 46 CFR 176.610. THE CURRENT SETUP OF LOCATINGTHE VALVE AFTER A VULNERABLE SECTION OF HOSE IS NOT ACCEPTABLE.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Lifesaving
Issued 26 January 1998
Resolved
PROVIDE WATERLIGHT ATTACHED TO LIFE RING BUOY PER 46 CFR 180.70. WATERLIGHT WAS NOT PRESENT DURING INSPECTION.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Lifesaving
Issued 26 January 1998
Resolved
PROVE THAT 15 PERSON BUOYANT APPARATUS IS ACCEPTABLE FOR 15 PERSON LIFEFLOAT PER 46 CFR 180.200. FOLLOW-UP SHOWED G-MSE-4 E-MAIL OF 21FEB97 SAID CONVERSION OK (CLEARED).
Condition: Unknown
Due 25 February 1998
Resolved 25 February 1998
Lifesaving
Issued 26 January 1998
Resolved
INSTALL RETRO-REFLECTIVE TAPE IN 4 ENCIRCLING RINGS, 2 INCHES WIDE PER 46 CFR 185.604. TAPE INSTALLED AT TIME OF INSPECTION WAS INSUFFICIENT.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Lifesaving
Issued 26 January 1998
Resolved
PROVIDE APPROVED FIRST AID KIT PER 46 CFR 184.710. NO EVIDENCE OF THIS EQUIPMENT AT THE INSPECTION.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Navigation
Issued 26 January 1998
Resolved
PROVIDE CORRECTED CHART, APPLICABLE SECTION OF COAST PILOT, LIGHT LIST, ANDTIDE TABLES PER 46 CFR 184.420. THERE WAS NO EVIDENCE OF THESE REQUIRED DOCUMENTS.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Fire Fighting
Issued 26 January 1998
Resolved
PROVIDE 3 TWO AND A HALF GALLON FIRE BUCKETS, LABELED, WITH LANYARDS ATTACHED PER 46 CFR 181.610. FIRE BUCKETS WERE NOT PRESENT AT INSPECTION.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Fire Fighting
Issued 26 January 1998
Resolved
INSTALL FIXED GAS FIRE EXTINGUISHING SYSTEM W/AUTO ENGINE SHUT OFF, VISUAL ALARM, REMOTE & MANUAL ACTIVATION, MARKINGS AT CONTROL STATION & ALARM, & ACTIVATION INSTRUCTIONS PER 46 CFR 181.410/420/612. NO FIXED SYSTEM INSTALLED AT TIME OF INSPECTION.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Engineering
Issued 26 January 1998
Resolved
INSTALL SECOND MEANS OF ENGINE CONTROL PER 46 CFR 184.620. THERE WAS NO EVIDENCE OF EQUIPMENT TO READILY DISCONNECT THE REMOTE ENGINE CONTROL LINKAGE TO PERMIT LOCAL OPERATION.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Engineering
Issued 26 January 1998
Resolved
INSTALL FLAME SCREEN IN AFT VENT PER 46 CFR 182.450. FORWARD VENT HAD A FLAME SCREEN. AFT VENT DID NOT.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Electrical
Issued 26 January 1998
Resolved
INSTALL CORROSION RESISTANT BATTERY TRAY PER 46 CFR 186.350. PRESENT TRAY IS NOT MADE OF CORROSION RESISTANT MATERIAL.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Navigation
Issued 26 January 1998
Resolved
RADIO WAS NOT FUSED AT MAIN DISTRIBUTION PANEL PER 46 CFR 183.392. RADIO WAS FUSED IN IMPROPER LOCATION ABOVE RADIO.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Construction/Loadline
Issued 26 January 1998
Resolved
INSTALL FORWARD BILGE PUMP PER 46 CFR 182.520. FORWARD BILGE PUMP WAS MISSING AT INSPECTION.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Construction/Loadline
Issued 26 January 1998
Resolved
INSTALL BILGE PUMP OPERATION INDICATOR FOR AUTOMATIC & MANUAL OPERATION PER46 CFR 182.530. INDICATOR SHOULD HAVE BEEN INSTALLED AT NEW CONSTRUCTION.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Construction/Loadline
Issued 26 January 1998
Resolved
INSTALL BILGE HIGH LEVEL ALARMS (AUDIBLE AND VISUAL) AT THE OPERATING STATION PER 46 CFR 182.530. HIGH LEVEL ALARMS SHOULD HAVE BEEN INSTALLED AT CONSTRUCTION.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Documentation
Issued 26 January 1998
Resolved
PROVIDE FCC OPERATOR'S LICENSE PER 47 CFR 80. NONE PROVIDED DURING INSPECTION.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Lifesaving
Issued 31 December 1996
Resolved
PROVIDE PLACARD FOR EMERGENCY INSTRUCTIONS AND DISTRESS SIGNALS ON CONSOLE.
Condition: Unknown
Due 31 December 1996
Resolved 31 December 1996
Lifesaving
Issued 31 December 1996
Resolved
FASTEN LINE FROM WATERLIGHT TO BA AND PAINTER FOR BA.
Condition: Unknown
Due 31 December 1996
Resolved 31 December 1996
Lifesaving
Issued 31 December 1996
Resolved
PROVIDE PROPER PLACARD FOR STOWAGE OF CHILD'S LIFEJACKETS.
Condition: Unknown
Due 31 December 1996
Resolved 31 December 1996
Documentation
Issued 31 December 1996
Resolved
PROVIDE FCC CERTIFICATE.
Condition: Unknown
Due 31 December 1996
Resolved 31 December 1996
Accommodation/Occupational Safety
Issued 31 December 1996
Resolved
PLACE NON-SKID AT DECK EDGES.
Condition: Unknown
Due 31 December 1996
Resolved 31 December 1996
Construction/Loadline
Issued 31 December 1996
Resolved
TRIM SCREWS CLOSE TO TUBES ON AFT, PORT SIDE.
Condition: Unknown
Due 31 December 1996
Resolved 31 December 1996