MAURY USCG vessel records
← All vessels

DEEP STIM II

Built
1997
Last inspected
27 May 2020
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 May 2020
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9132222
WCX5002
451310
Flag
UNITED STATES
Maury page id
psix-451310

Documentation record

Registered dimensions (L × B × D)251.0 ft × 56.0 ft × 18.8 ft
Registered tonnagegross 2,998 / net 974
ITC dimensions (L × B × D)251.0 ft × 56.0 ft × 18.8 ft
ITC tonnagegross 2,998 / net 974
BuilderNORTH AMERICAN SHIPBLDG. · LAROSE, LA, UNITED STATES · built 1997
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portGALLIANO, LA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 18 June 2026 · expires 31 July 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2998 - Convention (Subpart B), Gross Ton
974 - Convention (Subpart B), Net Ton
2482 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 13 inspections, each with its date, unit and type; 47 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 13

27 May 2020 Administrative Inspection
Administrative · Activities Europe · Activity 6961488
27 December 2019 MTSA/ISPS Verification · Annual Inspection · ACP Annual Oversight
Physical examination · Activities Europe · Activity 6851936
21 March 2019 Administrative Inspection
Administrative · Activities Europe · Activity 6646495
22 October 2018 Administrative Inspection
Administrative · Activities Europe · Activity 6566276
19 September 2018 MTSA/ISPS Verification · Annual Inspection
Physical examination · Activities Europe · Activity 6507913
17 May 2018 Administrative Inspection
Administrative · Commandant (CG-ENG) · Activity 6416694
13 January 2018 Drydock Exam · ACP Handover Survey
Physical examination · Activities Europe · Activity 6324185
5 December 2017 Administrative Inspection
Administrative · Activities Europe · Activity 6318411
3 October 2017 MARPOL Annex V Examination · MARPOL Annex I Examination · MARPOL Annex II Examination · MARPOL Annex IV Survey · ACP Handover Survey · MARPOL Annex VI Survey · Administrative Inspection · Annual Inspection · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 6264935
21 July 2017 Damage Survey · Administrative Inspection
Physical examination · Activities Europe · Activity 6218955
21 October 2016 MARPOL Annex VI Survey · MARPOL Annex II Examination · MTSA/ISPS Verification · MARPOL Annex IV Survey · Annual Inspection · MARPOL Annex I Examination
Physical examination · Activities Europe · Activity 6029876
19 August 2016 Administrative Inspection
Administrative · Activities Europe · Activity 5976927
19 August 2016 Administrative Inspection
Administrative · Activities Europe · Activity 5980472

Deficiency record · 47

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 December 2019 Resolved
Life jackets were found without SOLAS approved retroreflective tape. Crew corrected on the spot when identified.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 December 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 December 2019 Resolved
A dead end cable was found hanging in the laundry, above the washing machine. Crew removed the cable and properly sealed the MCT.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 December 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 December 2019 Resolved
Air receiver on upper weather deck, for frac space, has severely corroded legs.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 February 2020
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 27 December 2019 Resolved
Angle iron support for mixing pump stand, port side, aft, is severely corroded and in need of repair.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 February 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 27 December 2019 Resolved
Air compressor in Frac space, stbd side, has the air psi monitor box improperly mounted to piping, and the expanded metal belt guard, is only held in place with twine.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 February 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 December 2019 Resolved
Blue Electrical box, stbd side, aft of frac space air compresson, is missing securing clips, and the door is being held partially closed by "warning tape".
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 February 2020
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 27 December 2019 Resolved
Remote valves on high psi cargo pump, port side fwd, in frac space, found lying on the deck, not working.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 February 2020
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 27 December 2019 Resolved
High PSI cargo pipe penetration flange on aft bulkhead, stbd side of pump room, not properly secured. Bolts missing from flange, and daylight passing through, proving not watertight.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 February 2020
12 - Dangerous Goods › N/A - No Subsystem › Personal protection
Issued 27 December 2019 Resolved
Make proper, permanent installation of eyewash station on port aft bulkhead of frac house. Current configuration has a garden hose run from a spigot on the stbd side.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 February 2020
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 27 December 2019 Resolved
Hydraulic hoses for remote closure, aft/top of Frac house, IWO ladder, need to be properly supported/secured.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 February 2020
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 December 2019 Resolved
Replace 7 spare SOLAS fire extinguishers with USCG or UL approved portable fire extinguishers. Per ACP Supplement.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 February 2020
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 27 December 2019 Resolved
In the event of any one survival craft being lost or rendered unserviceable, there shall be sufficient survival craft available for use on each side to accommodate the total number of persons on board. Current configuration of 25&20 man raft does not cover the 29 POB if 1 raft is lost.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 February 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 September 2018 Resolved
Observed drain valve of diesel fuel tank located in frac pump room altered by crew by installling flex hose to tool cleaning box. Addressed hazardous condition with vessel crew. Immediately rectified by removal of hose and plugging of drain valve.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 20 September 2018
Resolution: Immediately rectified by removal of hose and plugging of drain valve.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 20 September 2018 Resolved
Engine room sliding watertight dooris not properly sealed. Must rectify prior to movement.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 October 2018
Resolution: Refer to attached Class Report.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 September 2018 Resolved
Fire doors located throughout accommodations, engine space, and frac spaces not self-closing as designed. Must make adjustments to the satisfation of Class.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 September 2018
Resolution: vessel provided video evidence of deficiency correction.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 September 2018 Resolved
Worn flex loop on one of the CO2 tanks provided for fixed fire extinguishing to frac space. Must replace hose.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 October 2018
Resolution: Master provided photo proof that deficiency was rectified.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 September 2018 Resolved
Replace all non-UL fire extinguishers.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 September 2018
Resolution: Master sent proof pics to CG inspector
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 September 2018 Resolved
Navigation light loss of function alarm not working.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 October 2018
Resolution: Refer to attached Class Report
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 20 September 2018 Resolved
Ground detection panel for distrubution ELP 201 in emergency generator room not functioning.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 September 2018
Resolution: Vessel Master sent video proof to CG Inspectors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 September 2018 Resolved
Bilge manifold tags are missing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 October 2018
Resolution: Refer to attached Class Report.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 20 September 2018 Resolved
Replace all SOLAS stickers that have faded.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 October 2018
Resolution: Refer to attached Class Report.
Documentation › Certificates/Documents › Certificate of Fitness (OSVs)
Issued 17 January 2018 Resolved
Vesssel is not fitted with various acid spill protective measures (e.g., containment, spray shields, anti-corrosion lining, etc.) prescribed by IMO Resolution A. 673(16). Demonstrate compliance prior to carriage of acid products authorized by Certificate of Fitness (COF)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2018
Resolution: Cleared via e-mailed photos
Documentation › Logs/Records › Cargo Record Book (NLS)
Issued 17 January 2018 Resolved
Vessel's Cargo [name withheld] indicates carriage of NLS cargoes not authorized to be carried IAW COF. Submit revised cargo authorization request to USCG Hazardous Material Division (CG-ENG-5) prior to carriage of NLS cargoes beyond specified date.
Due 17 April 2018
Resolved 25 May 2018
Resolution: Cleared via cargo approval from CG HQ
Personnel › Certificates/Documents/Licenses › PIC
Issued 17 January 2018 Resolved
An approved tankerman, credentialed IAW 46 CFR Part 13, is required to be onboard for the loading or discharge of NLS cargoes to/from any potable tank beyond specified date. An STCW Chapter V/1-1 endoresement is considered to be equivalent for the purpose of this requirement.
Due 17 April 2018
Resolved 25 May 2018
Resolution: Cleared via e-mailed correspondence
Engineering › Diesel Engine (auxiliary) › Piston Ring
Issued 5 December 2017 Resolved
Port generator has a broken lifter retainer ring.
Action required: 705 - Other - as specified
Due 5 January 2018
Resolved 4 January 2018
Resolution: Vessel provided a technicians report stating repairs have been completed and it has been operationally tested.
Navigation › Emergency Steering › Compass Reading for Emergency Steering
Issued 5 October 2017 Resolved
Magnetic compass in local steering compartment is without deviation card and heading reading differs from control station magnetic compass by 6 degrees. Provide deviation card and ensure accurate heading indication at local steering.
Due 12 October 2017
Resolved 8 October 2017
Resolution: Cleared via e-mail from vessel [name withheld] Ref#2274929
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 5 October 2017 Resolved
Provide native language translations of emergency instructions and station bill duties for non-English speaking crew members.
Due 12 October 2017
Resolved 8 October 2017
Resolution: Resolved via e-mail from vessel [name withheld] ref#2274929
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 5 October 2017 Resolved
Fixed CO2 system protecting well stimulation space is not fully operable. Replace missing cylinder and test to ensure system integrity.
Due 10 January 2018
Resolved 23 February 2018
Resolution: Cleared via e-mail from ABS surveyor [name withheld]
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 5 October 2017 Resolved
Electric motors serving well-stimulation pumps are without required data plates. Provide plates or alternate means to demonstrate compliance with 46 CFR Subchapter L.
Due 4 November 2017
Resolved 23 October 2017
Resolution: Cleared via e-mail from vessel master [name withheld]
Communications › Public Address System › Loudspeaker
Issued 5 October 2017 Resolved
Public address system within well stimulation spaces is not audible. Prove operability and audibility of system in these spaces.
Due 10 January 2018
Resolved 23 February 2018
Resolution: Cleared via e-mail from ABS surveyor [name withheld]
Accommodation/Occupational Safety › Washroom/Toilet › Washbasin
Issued 5 October 2017 Resolved
Prove effective water pressure at eyewash stations in forward well stimulation space on main deck and at hazardous zone on 01 deck.
Due 4 November 2017
Resolved 23 October 2017
Resolution: Cleared via e-mail from vessel master [name withheld]
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 5 October 2017 Resolved
Install nonconductive mat on deck grating at rear of main switchboard within pump room.
Due 10 January 2018
Resolved 23 February 2018
Resolution: Cleared via e-mail from ABS surveyor [name withheld]
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 5 October 2017 Resolved
Prove full operability of fire detection and alarm system serving well stimulation package. Identified faults and inoperable detectors must be corrected and tested for operability.
Due 11 November 2017
Resolved 10 November 2017
Resolution: Cleared via e-mail from vessel master [name withheld]
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Combustible Gas Indicator
Issued 5 October 2017 Resolved
Vessel is without portable means to test atmosphere of enclosed spaces as required for carriage of NLS and enclosed space entry. Provide evidence that required instruments are onboard and calibrated.
Due 11 November 2017
Resolved 10 November 2017
Resolution: Cleared via e-mail from vessel master [name withheld]
Construction/Loadline › Structures › Machinery Space Opening
Issued 5 October 2017 Resolved
Plug open cable penetration block in aft bulkhead of pump room; demonstrate effective means of securing space in event of fire.
Due 4 November 2017
Resolved 8 October 2017
Resolution: Cleared via e-mail from vessel master [name withheld]
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 October 2017 Resolved
Compressed gas cylinders must be secured and provided with valve protection caps when not in use IAW 46 CFR 147.60(b)(1). Provide protective caps for valves of all compressed gas cylinders.
Due 10 January 2018
Resolved 13 January 2018
Resolution: Cleared during drydock exam
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 5 October 2017 Resolved
Leak identified in #2 SSDG exhaust piping in centerline machinery space passageway. Effect permanent repairs to compromised pipe; until such time, institute appropriate risk mitigation measures for when #2 SSDG is running.
Due 10 January 2018
Resolved 13 January 2018
Resolution: Cleared during drydock exam. Flex coupling replaced; NDT.
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 5 October 2017 Resolved
Provide technician’s report attesting to satisfactory testing of safety shutdowns/alarms for prime movers for generators powering well stimulation operations.
Due 10 January 2018
Resolved 23 February 2018
Resolution: Cleared via e-mailed report from [name withheld], Schlumberger
Electrical › Electrical Distribution System (service) › Junction Box
Issued 5 October 2017 Resolved
Function test and demonstrate explosion proof or intrinsically safe compliance of fire alarm pull boxes located within identified hazardous areas.
Due 10 January 2018
Resolved 23 February 2018
Resolution: Cleared via e-mail from ABS surveyor [name withheld]
Deck/Cargo › Mooring/Anchoring › Mooring Arrangement
Issued 5 October 2017 Resolved
Damaged mooring bitts and adjacent bulwarks at port aft section of main deck must be permanently repaired to original design.
Due 10 January 2018
Resolved 13 January 2018
Resolution: Cleared during drydock exam
Construction/Loadline › Structures › Deck Plating
Issued 5 October 2017 Resolved
Effect permanent repairs to compromised Class “A” boundaries of well stimulation PCM/mixing space, e.g., wasted steel/holes in outboard bulkhead on starboard side and port aft deck IWO acid mixing room.
Due 10 January 2018
Resolved 13 January 2018
Resolution: Cleared during drydock exam
Communications › Alarms/Indicators › Bilge Alarm
Issued 21 July 2017 Resolved
Please note this is directly related to engine room machinery; z-drive room, engines, gens, bilges, etc.
Due 7 August 2017
Resolved 2 August 2017
Resolution: Alarm panel replaced and is fully operational.
Electrical › Electric Generation Source (service) › Panelboard
Issued 21 October 2016 Resolved
Prove proper operation of the reverse power relay on the center generator.
Action required: 705 - Other - as specified
Due 21 December 2016
Resolved 9 December 2016
Resolution: Vessel provided proof of the reverse power relay.
Construction/Loadline › Structures › Scuttle
Issued 21 October 2016 Resolved
Make weld repairs to the engine room emergency escape trunk
Action required: 17 - Rectify deficiencies prior to departure
Due 21 October 2016
Resolved 21 October 2016
Resolution: Vessel made repairs to emergency escape trunk.
Engineering › Diesel Engine (propulsion-electric) › Nozzle, Injection (fuel injection)
Issued 21 October 2016 Resolved
Replace fuel hose on drop down thruster
Action required: 705 - Other - as specified
Due 21 December 2016
Resolved 18 December 2016
Resolution: Vessel replaced the fuel hose on the drop down thruster.
Lifesaving › Rescue Boat › Fender
Issued 21 October 2016 Resolved
Replace the shock absorbing fender on the rescue boat
Action required: 705 - Other - as specified
Due 21 February 2017
Resolved 7 February 2017
Resolution: Vessel replaced fender with a new one, pictures were provided be the vessel rep.
Lifesaving › Inflatable Liferafts › Servicing
Issued 19 August 2016 Resolved
Vessel rep requested extension due to port access. Permitted the extension request to next USCG COI Annual inspection, NLT 3 months past anniversary date.
Due 3 December 2016
Resolved 27 October 2016
Resolution: Received email confirmation and servicing certificates for the inflatable liferaftts.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.