Records from 1997 to 2020. Most recent: inspection, 27 May 2020.
Inspection history · 39
27 May 2020
Administrative Inspection
Administrative · Activities Europe · Activity 6961488
27 December 2019
MTSA/ISPS Verification · Annual Inspection · ACP Annual Oversight
Physical examination · Activities Europe · Activity 6851936
21 March 2019
Administrative Inspection
Administrative · Activities Europe · Activity 6646495
22 October 2018
Administrative Inspection
Administrative · Activities Europe · Activity 6566276
19 September 2018
MTSA/ISPS Verification · Annual Inspection
Physical examination · Activities Europe · Activity 6507913
17 May 2018
Administrative Inspection
Administrative · Commandant (CG-ENG) · Activity 6416694
13 January 2018
Drydock Exam · ACP Handover Survey
Physical examination · Activities Europe · Activity 6324185
5 December 2017
Administrative Inspection
Administrative · Activities Europe · Activity 6318411
3 October 2017
MARPOL Annex V Examination · MARPOL Annex I Examination · MARPOL Annex II Examination · MARPOL Annex IV Survey · ACP Handover Survey · MARPOL Annex VI Survey · Administrative Inspection · Annual Inspection · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 6264935
21 July 2017
Damage Survey · Administrative Inspection
Physical examination · Activities Europe · Activity 6218955
21 October 2016
MARPOL Annex VI Survey · MARPOL Annex II Examination · MTSA/ISPS Verification · MARPOL Annex IV Survey · Annual Inspection · MARPOL Annex I Examination
Physical examination · Activities Europe · Activity 6029876
19 August 2016
Administrative Inspection
Administrative · Activities Europe · Activity 5976927
19 August 2016
Administrative Inspection
Administrative · Activities Europe · Activity 5980472
3 August 2015
Drydock Exam · MARPOL Annex VI Survey · Cargo Tank Internal · Internal Structural Exam · COI Inspection · MARPOL Annex II Examination · MARPOL Annex I Examination · MARPOL Annex IV Survey · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 5189890
2 October 2014
Annual Inspection · MARPOL Annex I Examination · MTSA/ISPS Verification
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 4997106
15 October 2010
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3875759
23 October 2008
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3349906
28 May 2008
Administrative Inspection · Cargo Tank Internal · Internal Structural Exam · Underwater Inspection in lieu of Drydock · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3219980
21 May 2008
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3213112
10 January 2008
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3127837
14 September 2007
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3060823
16 August 2006
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2750266
1 November 2005
Internal Structural Exam · Cargo Tank Internal · Examination of Repairs · Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2526994
27 September 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2502143
23 November 2004
MTSA/ISPS Verification · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2246673
17 November 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1949019
30 May 2003
Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1816578
10 December 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1716525
8 November 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1710640
4 February 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1483559
25 February 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 81045
21 August 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 23690
1 July 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 821356
30 March 1999
Administrative
Administrative · Activities Europe · Activity 1116849
10 July 1998
Administrative
Administrative · Activities Europe · Activity 1128775
13 May 1997
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439856
9 May 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1100999
5 May 1997
Deadweight Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1102408
2 February 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 184763
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 December 2019
Resolved
Life jackets were found without SOLAS approved retroreflective tape. Crew corrected on the spot when identified.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 December 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 December 2019
Resolved
A dead end cable was found hanging in the laundry, above the washing machine. Crew removed the cable and properly sealed the MCT.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 December 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 December 2019
Resolved
Air receiver on upper weather deck, for frac space, has severely corroded legs.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 February 2020
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 27 December 2019
Resolved
Angle iron support for mixing pump stand, port side, aft, is severely corroded and in need of repair.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 February 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 27 December 2019
Resolved
Air compressor in Frac space, stbd side, has the air psi monitor box improperly mounted to piping, and the expanded metal belt guard, is only held in place with twine.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 February 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 December 2019
Resolved
Blue Electrical box, stbd side, aft of frac space air compresson, is missing securing clips, and the door is being held partially closed by "warning tape".
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 February 2020
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 27 December 2019
Resolved
Remote valves on high psi cargo pump, port side fwd, in frac space, found lying on the deck, not working.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 February 2020
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 27 December 2019
Resolved
High PSI cargo pipe penetration flange on aft bulkhead, stbd side of pump room, not properly secured. Bolts missing from flange, and daylight passing through, proving not watertight.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 February 2020
12 - Dangerous Goods › N/A - No Subsystem › Personal protection
Issued 27 December 2019
Resolved
Make proper, permanent installation of eyewash station on port aft bulkhead of frac house. Current configuration has a garden hose run from a spigot on the stbd side.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 February 2020
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 27 December 2019
Resolved
Hydraulic hoses for remote closure, aft/top of Frac house, IWO ladder, need to be properly supported/secured.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 February 2020
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 December 2019
Resolved
Replace 7 spare SOLAS fire extinguishers with USCG or UL approved portable fire extinguishers. Per ACP Supplement.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 February 2020
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 27 December 2019
Resolved
In the event of any one survival craft being lost or rendered unserviceable, there shall be sufficient survival craft available for use on each side to accommodate the total number of persons on board. Current configuration of 25&20 man raft does not cover the 29 POB if 1 raft is lost.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 February 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 September 2018
Resolved
Observed drain valve of diesel fuel tank located in frac pump room altered by crew by installling flex hose to tool cleaning box. Addressed hazardous condition with vessel crew. Immediately rectified by removal of hose and plugging of drain valve.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 20 September 2018
Resolution: Immediately rectified by removal of hose and plugging of drain valve.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 20 September 2018
Resolved
Engine room sliding watertight dooris not properly sealed. Must rectify prior to movement.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 October 2018
Resolution: Refer to attached Class Report.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 September 2018
Resolved
Fire doors located throughout accommodations, engine space, and frac spaces not self-closing as designed. Must make adjustments to the satisfation of Class.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 September 2018
Resolution: vessel provided video evidence of deficiency correction.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 September 2018
Resolved
Worn flex loop on one of the CO2 tanks provided for fixed fire extinguishing to frac space. Must replace hose.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 October 2018
Resolution: Master provided photo proof that deficiency was rectified.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 September 2018
Resolved
Replace all non-UL fire extinguishers.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 September 2018
Resolution: Master sent proof pics to CG inspector
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 September 2018
Resolved
Navigation light loss of function alarm not working.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 October 2018
Resolution: Refer to attached Class Report
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 20 September 2018
Resolved
Ground detection panel for distrubution ELP 201 in emergency generator room not functioning.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 September 2018
Resolution: Vessel Master sent video proof to CG Inspectors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 September 2018
Resolved
Bilge manifold tags are missing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 October 2018
Resolution: Refer to attached Class Report.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 20 September 2018
Resolved
Replace all SOLAS stickers that have faded.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 October 2018
Resolution: Refer to attached Class Report.
Documentation › Certificates/Documents › Certificate of Fitness (OSVs)
Issued 17 January 2018
Resolved
Vesssel is not fitted with various acid spill protective measures (e.g., containment, spray shields, anti-corrosion lining, etc.) prescribed by IMO Resolution A. 673(16). Demonstrate compliance prior to carriage of acid products authorized by Certificate of Fitness (COF)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2018
Resolution: Cleared via e-mailed photos
Documentation › Logs/Records › Cargo Record Book (NLS)
Issued 17 January 2018
Resolved
Vessel's Cargo [name withheld] indicates carriage of NLS cargoes not authorized to be carried IAW COF. Submit revised cargo authorization request to USCG Hazardous Material Division (CG-ENG-5) prior to carriage of NLS cargoes beyond specified date.
Due 17 April 2018
Resolved 25 May 2018
Resolution: Cleared via cargo approval from CG HQ
Personnel › Certificates/Documents/Licenses › PIC
Issued 17 January 2018
Resolved
An approved tankerman, credentialed IAW 46 CFR Part 13, is required to be onboard for the loading or discharge of NLS cargoes to/from any potable tank beyond specified date. An STCW Chapter V/1-1 endoresement is considered to be equivalent for the purpose of this requirement.
Due 17 April 2018
Resolved 25 May 2018
Resolution: Cleared via e-mailed correspondence
Engineering › Diesel Engine (auxiliary) › Piston Ring
Issued 5 December 2017
Resolved
Port generator has a broken lifter retainer ring.
Action required: 705 - Other - as specified
Due 5 January 2018
Resolved 4 January 2018
Resolution: Vessel provided a technicians report stating repairs have been completed and it has been operationally tested.
Navigation › Emergency Steering › Compass Reading for Emergency Steering
Issued 5 October 2017
Resolved
Magnetic compass in local steering compartment is without deviation card and heading reading differs from control station magnetic compass by 6 degrees. Provide deviation card and ensure accurate heading indication at local steering.
Due 12 October 2017
Resolved 8 October 2017
Resolution: Cleared via e-mail from vessel [name withheld] Ref#2274929
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 5 October 2017
Resolved
Provide native language translations of emergency instructions and station bill duties for non-English speaking crew members.
Due 12 October 2017
Resolved 8 October 2017
Resolution: Resolved via e-mail from vessel [name withheld] ref#2274929
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 5 October 2017
Resolved
Fixed CO2 system protecting well stimulation space is not fully operable. Replace missing cylinder and test to ensure system integrity.
Due 10 January 2018
Resolved 23 February 2018
Resolution: Cleared via e-mail from ABS surveyor [name withheld]
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 5 October 2017
Resolved
Electric motors serving well-stimulation pumps are without required data plates. Provide plates or alternate means to demonstrate compliance with 46 CFR Subchapter L.
Due 4 November 2017
Resolved 23 October 2017
Resolution: Cleared via e-mail from vessel master [name withheld]
Communications › Public Address System › Loudspeaker
Issued 5 October 2017
Resolved
Public address system within well stimulation spaces is not audible. Prove operability and audibility of system in these spaces.
Due 10 January 2018
Resolved 23 February 2018
Resolution: Cleared via e-mail from ABS surveyor [name withheld]
Accommodation/Occupational Safety › Washroom/Toilet › Washbasin
Issued 5 October 2017
Resolved
Prove effective water pressure at eyewash stations in forward well stimulation space on main deck and at hazardous zone on 01 deck.
Due 4 November 2017
Resolved 23 October 2017
Resolution: Cleared via e-mail from vessel master [name withheld]
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 5 October 2017
Resolved
Install nonconductive mat on deck grating at rear of main switchboard within pump room.
Due 10 January 2018
Resolved 23 February 2018
Resolution: Cleared via e-mail from ABS surveyor [name withheld]
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 5 October 2017
Resolved
Prove full operability of fire detection and alarm system serving well stimulation package. Identified faults and inoperable detectors must be corrected and tested for operability.
Due 11 November 2017
Resolved 10 November 2017
Resolution: Cleared via e-mail from vessel master [name withheld]
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Combustible Gas Indicator
Issued 5 October 2017
Resolved
Vessel is without portable means to test atmosphere of enclosed spaces as required for carriage of NLS and enclosed space entry. Provide evidence that required instruments are onboard and calibrated.
Due 11 November 2017
Resolved 10 November 2017
Resolution: Cleared via e-mail from vessel master [name withheld]
Construction/Loadline › Structures › Machinery Space Opening
Issued 5 October 2017
Resolved
Plug open cable penetration block in aft bulkhead of pump room; demonstrate effective means of securing space in event of fire.
Due 4 November 2017
Resolved 8 October 2017
Resolution: Cleared via e-mail from vessel master [name withheld]
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 October 2017
Resolved
Compressed gas cylinders must be secured and provided with valve protection caps when not in use IAW 46 CFR 147.60(b)(1). Provide protective caps for valves of all compressed gas cylinders.
Due 10 January 2018
Resolved 13 January 2018
Resolution: Cleared during drydock exam
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 5 October 2017
Resolved
Leak identified in #2 SSDG exhaust piping in centerline machinery space passageway. Effect permanent repairs to compromised pipe; until such time, institute appropriate risk mitigation measures for when #2 SSDG is running.
Due 10 January 2018
Resolved 13 January 2018
Resolution: Cleared during drydock exam. Flex coupling replaced; NDT.
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 5 October 2017
Resolved
Provide technician’s report attesting to satisfactory testing of safety shutdowns/alarms for prime movers for generators powering well stimulation operations.
Due 10 January 2018
Resolved 23 February 2018
Resolution: Cleared via e-mailed report from [name withheld], Schlumberger
Electrical › Electrical Distribution System (service) › Junction Box
Issued 5 October 2017
Resolved
Function test and demonstrate explosion proof or intrinsically safe compliance of fire alarm pull boxes located within identified hazardous areas.
Due 10 January 2018
Resolved 23 February 2018
Resolution: Cleared via e-mail from ABS surveyor [name withheld]
Deck/Cargo › Mooring/Anchoring › Mooring Arrangement
Issued 5 October 2017
Resolved
Damaged mooring bitts and adjacent bulwarks at port aft section of main deck must be permanently repaired to original design.
Due 10 January 2018
Resolved 13 January 2018
Resolution: Cleared during drydock exam
Construction/Loadline › Structures › Deck Plating
Issued 5 October 2017
Resolved
Effect permanent repairs to compromised Class “A” boundaries of well stimulation PCM/mixing space, e.g., wasted steel/holes in outboard bulkhead on starboard side and port aft deck IWO acid mixing room.
Due 10 January 2018
Resolved 13 January 2018
Resolution: Cleared during drydock exam
Communications › Alarms/Indicators › Bilge Alarm
Issued 21 July 2017
Resolved
Please note this is directly related to engine room machinery; z-drive room, engines, gens, bilges, etc.
Due 7 August 2017
Resolved 2 August 2017
Resolution: Alarm panel replaced and is fully operational.
Electrical › Electric Generation Source (service) › Panelboard
Issued 21 October 2016
Resolved
Prove proper operation of the reverse power relay on the center generator.
Action required: 705 - Other - as specified
Due 21 December 2016
Resolved 9 December 2016
Resolution: Vessel provided proof of the reverse power relay.
Construction/Loadline › Structures › Scuttle
Issued 21 October 2016
Resolved
Make weld repairs to the engine room emergency escape trunk
Action required: 17 - Rectify deficiencies prior to departure
Due 21 October 2016
Resolved 21 October 2016
Resolution: Vessel made repairs to emergency escape trunk.
Engineering › Diesel Engine (propulsion-electric) › Nozzle, Injection (fuel injection)
Issued 21 October 2016
Resolved
Replace fuel hose on drop down thruster
Action required: 705 - Other - as specified
Due 21 December 2016
Resolved 18 December 2016
Resolution: Vessel replaced the fuel hose on the drop down thruster.
Lifesaving › Rescue Boat › Fender
Issued 21 October 2016
Resolved
Replace the shock absorbing fender on the rescue boat
Action required: 705 - Other - as specified
Due 21 February 2017
Resolved 7 February 2017
Resolution: Vessel replaced fender with a new one, pictures were provided be the vessel rep.
Lifesaving › Inflatable Liferafts › Servicing
Issued 19 August 2016
Resolved
Vessel rep requested extension due to port access. Permitted the extension request to next USCG COI Annual inspection, NLT 3 months past anniversary date.
Due 3 December 2016
Resolved 27 October 2016
Resolution: Received email confirmation and servicing certificates for the inflatable liferaftts.
Engineering › Diesel Engine (propulsion-direct drive) › Emergency shutdown
Issued 7 September 2015
Resolved
Vessel could not properly prove the proper operation of the over speed shutdown. Engine would continue to idle and not shutdown.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 September 2015
Resolved 13 September 2015
Resolution: ABS witnessed successful operation of the over speed shutdown.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Emergency shutdown
Issued 7 September 2015
Resolved
Vessel could not prove proper operation of the overspeed shutdown on the #2SSDG and J/W high temp alarm & shutdown on the #1 & #3 SSDG.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 September 2015
Resolved 13 September 2015
Resolution: ABS witnessed successful operation of shutdowns and alarms on the #1,2,3 SSDG's.
Engineering › Generator (propulsion/auxiliary-electric) › Reverse Power Protection Relay Circuitry
Issued 7 September 2015
Resolved
Vessel could not prove proper operation on the reverse power relay on the #2 SSDG.
Action required: 705 - Other - as specified
Due 5 October 2015
Resolved 13 September 2015
Resolution: ABS witnessed successful test of the reverse power relay.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 7 September 2015
Resolved
Replace outboard fwd flexible hose on the storage bottle for the Engine Room CO2 system.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 September 2015
Resolved 10 September 2015
Resolution: ABS attested to the instalation of the new hose.
Electrical › Electrical Distribution System (emergency) › Ground Indicator
Issued 7 September 2015
Resolved
Ground detector for the emergency generator was inoperable.
Action required: 705 - Other - as specified
Due 5 October 2015
Resolved 21 September 2015
Resolution: Vessel provided email confirmation that electrician tech verified that the ground detector is working properly.
Fire Fighting › Portable CO2 Fire Extinguisher › Discharge Hose/Tube
Issued 7 September 2015
Resolved
Replace CO2 horn in the fwd stbd pump room.
Action required: 705 - Other - as specified
Due 5 October 2015
Resolved 13 September 2015
Resolution: ABS attested to the replaced horn.
Communications › Alarms/Indicators › Fire Alarm
Issued 7 September 2015
Resolved
Replace the port PCM Room fire alarm pull box and prove proper operation.
Action required: 705 - Other - as specified
Due 5 October 2015
Resolved 13 September 2015
Resolution: Vessel repaired box and ABS witnessed successful operation of the pull box.
Communications › Alarms/Indicators › Sprinkler Alarm System
Issued 7 September 2015
Resolved
Replace CO2 alarm horn at the after pump room center bulkhead.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 September 2015
Resolved 13 September 2015
Resolution: New alarm horn was installed.
Engineering › Diesel Engine (auxiliary) › Nozzle, Injection (fuel injection)
Issued 7 September 2015
Resolved
Replace fuel gauge hose on the stbd generator in the Pump Room.
Action required: 705 - Other - as specified
Due 5 October 2015
Resolved 23 September 2015
Resolution: Vessel captain sent an email attesting to the installation and test of new fuel hose.
Electrical › Lighting (service) › Lighting Fixture
Issued 7 September 2015
Resolved
Provide and install guards for port side deck lights.
Action required: 705 - Other - as specified
Due 5 October 2015
Resolved 21 September 2015
Resolution: Received email confirmation form the Captain that new covers have been installed.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 7 September 2015
Resolved
Properly position rubber seals in stb pump room multi-cable transit fittings.
Action required: 705 - Other - as specified
Due 5 October 2015
Resolved 10 September 2015
Resolution: Received email from vessel that this was completed.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 7 September 2015
Resolved
Properly remove oil from under Pump Room generators.
Action required: 705 - Other - as specified
Due 5 October 2015
Resolved 10 September 2015
Resolution: Received email confirmation that vessel removed oil from bilge.
Personnel › Certificates/Documents/Licenses › License, Chief Engineer
Issued 7 September 2015
Resolved
Chief Engineer had a restriction on his License for Near Costal Domestic Voyages only.
Action required: 705 - Other - as specified
Due 5 October 2015
Resolved 12 September 2015
Resolution: New Chief Engineer arrived onboard with no restrictions on his credentials.
Accommodation/Occupational Safety › Ventilation › General
Issued 7 September 2015
Resolved
Motorized ventilation closures in the acid room and the fwd pump room were inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 September 2015
Resolved 13 September 2015
Resolution: ABS witnessed proper operation of the ventilation closures.
Deck/Cargo › Holds/Tanks › Cargo Tank Arrangement/Size
Issued 7 September 2015
Resolved
Provide approved plans for the independent acid tanks installed on the flight deck. Amendments shall be made to add these tanks to the Stability book, P&A Manual and SMPEP. Plans must be submitted to MSC for approval.
Action required: 705 - Other - as specified
Due 1 January 2016
Resolved 5 February 2016
Resolution: Vessel provided documentation of the addition of the acid tanks to the P&A manual, SMEP and a letter from class stating the tank capacity does not affect stability. Documentation attached.
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 7 September 2015
Resolved
Complete all periodic safety test procedures on the engines in the Schlumber Pump Room and submit a technicians report to the [name withheld].
Action required: 705 - Other - as specified
Due 5 October 2015
Resolved 2 October 2015
Resolution: Periodic safety test were conducted and results were provided.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 September 2015
Resolved
Stern light does not provide the correct 135 degrees of visibility. Reposition to correct location or provide approval of alternate compliance.
Action required: 705 - Other - as specified
Due 5 October 2015
Resolved 2 October 2015
Resolution: Stern light was relocated to the stern.
Engineering › Generator (propulsion/auxiliary-electric) › Reverse Power Protection Relay Circuitry
Issued 13 October 2014
Resolved
#1 SSDG speed control and reverse power relay protection was unable to be satisfactorily demonstrated during annual inspection. Must demonstrate proper repairs and operation of speed control / required alarms and shutdowns prior to utilizing it for primary power generation.
Action required: 705 - Other - as specified
Due 27 October 2014
Resolved 22 October 2014
Resolution: ABS attended vessel with third party contractor to witness successful demonstration of reverse power relay protection and required shutdowns / alarms. Report of Survey provided.
Engineering › Steering Gear System › Valve, Control
Issued 13 October 2014
Resolved
Control block for port steering system cracked upon testing of emergency steering. Prior to departure make repairs to control valve block and demonstrate proper operation in all modes for steering system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 October 2014
Resolution: Valve block replaced and steering system operation successfully demonstrated in the presence of attending ABS surveyor. Report of Survey provided.
Engineering › Generator (propulsion/auxiliary-electric) › Generator Voltage Regulator Circuitry
Issued 13 October 2014
Resolved
PRIOR TO WELL STIMULATION OPERATIONS: Makes repairs to #2 Client side generator and demonstrate proper operation of required alarms and shutdowns.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 October 2014
Resolution: Repairs were made to control side of client generators and proper operation of all alarms and shutdowns were demonstrated to the satisfaction of the attending ABS surveyor.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 23 October 2008
Resolved
Prove proper operation of vsl's OWS after repairs to solenoid to the attending inspector/surveyor.
Action required: 705 - Other - as specified
Due 23 November 2008
Resolved 23 October 2008
Resolution: Proper operation verified by attending ABSsurveyor.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 23 October 2008
Resolved
Renew deviation tables for both magenetic compasses onboard vsl.
Due 23 November 2008
Resolved 28 October 2008
Communications › Alarms/Indicators › General Alarm
Issued 23 October 2008
Resolved
Prove proper operation of vsl's general alarm tie-in with fire alarm (after two minutes unanswered) to the attending marine inspector or ABS surveyor.
Action required: 705 - Other - as specified
Resolved 28 October 2008
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 23 October 2008
Resolved
Install an emergency light at the e/r escape hatch and repair two inop e-lights at the generator switch board and engine room alleyway.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 October 2008
Resolution: Changed batteries in two and added one at the escape hatch as required.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 10 January 2008
Resolved
Provide additional fire protection for the filling and discharge of flammable or combustible products from the portable tanks prior to filling or discharging.
Action required: 705 - Other - as specified
Due 10 February 2008
Resolved 11 January 2008
Electrical › Electric Supply System (service)
Issued 10 December 2002
Resolved
PROVIDE PROPER BATTERY INSTALLATION FOR BATTERIES LOCATED AT 02 DECK LEVEL AC VENTILATION SPACE. LEGACY COMPONENT DESC: Battery Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 10 January 2003
Resolved 30 May 2003
Engineering › Fuel Oil Service System
Issued 10 December 2002
Resolved
PROVIDE METALLIC PLUGS FOR RACOR FILTERS ON ALL ENGINES. LEGACY COMPONENT DESC: Filter
Due 10 January 2003
Resolved 10 December 2002
Lifesaving › Lifebuoys
Issued 10 December 2002
Resolved
RENEW WATER LIGHT ON 02 DECK LIFERING. LEGACY COMPONENT DESC: Self-igniting Lights
Action required: 17 - Rectify deficiencies prior to departure
Due 10 January 2003
Resolved 10 December 2002
Lifesaving › Lifebuoys
Issued 10 December 2002
Resolved
RENEW LIFERING ON 02 DECK LEVEL. LEGACY COMPONENT DESC: LIFERING
Action required: 17 - Rectify deficiencies prior to departure
Due 10 January 2003
Resolved 10 December 2002
Lifesaving › Launching Appliances
Issued 10 December 2002
Resolved
RENEW RESCUE BOAT DAVIT FALLS. LEGACY COMPONENT DESC: Falls
Action required: 705 - Other - as specified
Due 10 January 2003
Resolved 30 May 2003
Operations/Management › Port and Waterways Safety
Issued 4 February 2002
Resolved
PROVIDE PROOF OF USER FEES PAYMENT PRIOR TO VESSEL MOVEMENT LEGACY COMPONENT DESC: USER FEES
Condition: Improper/Lack of Maintenance
Due 5 February 2002
Resolved 6 February 2002
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 4 February 2002
Resolved
PROPERLY INSTALL STBD O/B LIFERAFT RELEASE UNIT PRIOR TO SAILING
Condition: Improper/Lack of Maintenance
Due 5 February 2002
Resolved 5 February 2002
Communications › Radio Communications
Issued 4 February 2002
Resolved
PROVIDE AND POST PROOF OF GMDSS SHORE BASED MAINTENANCE AGREEMENT LEGACY COMPONENT DESC: GMDSS
Condition: Unknown
Due 5 February 2002
Resolved 5 February 2002
Construction/Loadline › Structures › Ventilators
Issued 4 February 2002
Resolved
REPAIR ALL MAIN DECK VENT SCREENS
Condition: Improper/Lack of Maintenance
Due 5 February 2002
Resolved 5 February 2002
Construction/Loadline › Structures › Door
Issued 4 February 2002
Resolved
PROVIDE AND INSTALL MISSING DOGS ON PORT MAIN ECK GALLEY PANTRY WTD
Condition: Placed in Improper Service
Due 5 February 2002
Resolved 5 February 2002
Engineering › Fuel Oil Service System › Filter
Issued 4 February 2002
Resolved
REPLACE PLASTIC PETCOCKS IN ALL FUEL OIL FILTER FLAME BOWLS WITH METALLIC PLUGS
Condition: Improper/Lack of Maintenance
Due 5 February 2002
Resolved 5 February 2002
Communications › Internal Communications System › Sound-powered Telephone
Issued 4 February 2002
Resolved
DEMONSTRATE PROPER OPERATION OF THE AFT STEERING STATION SPP VISUAL CALL INDICATOR UNDER EMERGENCY POWER
Condition: Improper Installation
Due 5 February 2002
Resolved 7 February 2002