RANGER

RANGER is a 1966 passenger vessel (inspected). The Coast Guard has recorded 76 inspections since 1985, most recently in November 2025, along with 90 deficiencies, 1 operational control and 1 casualty investigation in 2006.

Records from 1985 to 2025. Most recent: inspection, 13 November 2025.

Built
1966
Last inspected
13 November 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WV9960
Flag
UNITED STATES
366729030
Maury page id
psix-45146

Inspections, by type

…with no type recorded4
Years with a record 39 calendar years (1985–2025)
The 76 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)58.8 ft × 14.3 ft × 7.2 ft
Registered tonnagegross 43 / net 29
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY CRAFT, INC. · LOREAUILLE, LA, UNITED STATES · built 1966
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLONG BEACH, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it43 - Regulatory (Subpart C or D), Gross Ton
29 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ6969MMSI 366729030 · active · compulsorily equipped · granted 5 August 2017, expires 5 August 2027
WV9960MMSI 366729030 · expired · compulsorily equipped · granted 29 November 2006, cancelled 1 April 2017
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 76

13 November 2025 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8037509
17 December 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7734011
17 January 2024 Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7734024
11 December 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7607020
7 November 2022 Plan Review "T" Boat · Examination of Repairs · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7591073
2 May 2022 Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7442258
31 January 2022 Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7388185
6 December 2021 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7363185
22 September 2021 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7318531
1 June 2021 Administrative Inspection · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7212438
28 October 2020 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7085793
5 September 2019 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6751042
21 January 2019 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6879207
9 August 2018 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6505667
8 January 2018 Hull Examination · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6338834
16 August 2017 Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6230591
11 August 2016 Annual Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5947207
27 January 2016 Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5789077
25 August 2015 Annual Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5201046
23 October 2014 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5002540
30 May 2012 DAPI Audit
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4368971
8 September 2011 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4139500
21 October 2010 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3863391
11 December 2008 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3378282
12 November 2008 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3350409
25 March 2008 Plan Review "T" Boat · In-Service Inspection · Construction Oversight
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3167730
21 November 2007 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3102526
13 November 2007 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3097928
10 October 2006 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2797880
20 September 2006 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2748166
3 July 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2705072
31 March 2006 Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2611206
19 October 2005 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2514704
14 October 2005 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2509979
28 December 2004 Excursion Permit
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2266084
20 October 2004 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2224848
9 September 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2175536
11 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1963221
18 November 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1950096
29 October 2002 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1695623
5 September 2002 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1668830
6 September 2001 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1366605
7 September 2000 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1395535
8 September 1999 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1372758
29 October 1998 Hull Examination · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1464137
11 September 1998 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1464132
19 November 1997 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1416604
11 September 1997 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1461829
13 September 1996 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1385811
15 November 1995 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1398363
14 September 1995 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1380300
14 March 1995 Examination of Repairs
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 868392
13 March 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 111369
20 September 1994 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 869737
23 November 1993 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 848386
10 November 1993 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1135483
26 August 1993 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 848457
26 May 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1140969
17 September 1992 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 957476
8 November 1991 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 940160
20 September 1991 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1252309
18 September 1990 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 928368
19 April 1990 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1213481
20 September 1989 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1210010
8 March 1989 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 889903
14 October 1988 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 887278
25 April 1988 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1037469
5 November 1987 Damage Survey
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1024981
15 October 1987 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1013991
23 September 1987 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1008002
17 September 1987 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1316115
15 May 1987 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1331657
30 September 1986 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1314993
7 November 1985 Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 995196
22 August 1985 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1293064
12 February 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 980677

Deficiency record · 90

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 November 2025 Resolved
All cable and wire must be installed with metal supports spaced not more than 610 milimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to building or retention of multiple cable installations, and not used as a means of support. MI observed metal supports were spaced more than 24 inches apart in the forward compartment. Install adequate amount of supports.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2025
Resolved 21 November 2025
Resolution: Metal wire supports were installed 24 inches apart in the forward compartment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 December 2024 Resolved
A flexible tube or hose may be used instead of fixed pipe for the discharge line of a submersible electric bilge pump. The discharge line of the submersible electric bilge pump in the forward bilge compartment, engine room, and lazarette was composed of plastic.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2024
Resolved 31 December 2024
Resolution: Vessel representative submitted photos to the satisfaction of the MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 December 2024 Resolved
All cables and wires must be installed with metal supports spaced not more than 24 inches apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support. In the forward bilge compartment, plastic tie wraps were used to support overhead cables.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2024
Resolved 31 December 2024
Resolution: Vessel representative submitted photos to the satisfaction of the MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 December 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock;MI identified dead end wires in aft engine room bulkhead.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2023
Resolved 13 December 2023
Resolution: Dead end wires removed. All Sat.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 11 December 2023 Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. MI identified hydraulic fluid in fwd bilge compartment.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2023
Resolved 13 December 2023
Resolution: Hydraulic fluid in bilge compartment removed. All Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 November 2022 Resolved
Bilge system. Bilge in Laz, mid-cabin and fwd cabin inneffective and unable to pump.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 17 November 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 November 2022 Resolved
Required design verification testing on SPVs. Vessel has not provided QFA/DVTP for newly installed throttles. CVC policy letter 17-07 (184.620.c.)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2022
Resolved 13 December 2023
Resolution: Vessel provided QFA/DVPT. Attached in documents; All Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 November 2022 Resolved
Ring life buoy light, while functional, has battery expired in 2019.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 November 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 September 2021 Resolved
"Each ring life buoy on a vessel must be approved in accordance with § 160.050 in subchapter Q of this chapter." Ring life buoy found deteriorated past serviceable condition.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2021
Resolved 28 September 2021
Resolution: Verified replacement of old ring life buoy.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 October 2020 Resolved
Receptacle outlets and attachment plugs for portable lamps, tools, and similar apparatus operating at 100 volts or more, must have a grounding pole and a grounding conductor in the portable cord. An outlet in the lower forward compartment near the collision bulkhead was found to have an open ground and an outlet at the steering console was found to have an open ground.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2020
Resolved 29 October 2020
Resolution: Receptacles grounded by certified electrician.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 5 September 2019 Resolved
Construction must allow safe operation of the vessel giving consideration for a seaworthy hull. found hull wastage of 40% in the lazzeret. Provide a repair proposal.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2019
Resolved 6 September 2019
Resolution: received an expectable repair proposal.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 August 2018 Resolved
During the inspection it was discovered that the vessel's emergency lighting was not operation when primary power was secured. This discrepancy was corrected, to the satisfaction of the attending Marine Inspector prior to departing the vessel.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 9 August 2018
Resolved 9 August 2018
Resolution: An evaluation of the lighting system, by company maintenance staff, found a loose light bulb that when tightened allowed the entire system to energize.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 August 2018 Resolved
During the inspection it was discovered that 10 adult type 1 lifejackets (kapok) had exceeded there service life. This discrepancy was corrected, to the satisfaction of the attending Marine Inspector prior to departing the vessel.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 9 August 2018
Resolved 9 August 2018
Resolution: 10 new type 1 life jackets were placed in service with proper labeling.
Construction/Loadline › Hull › Hull Plating
Issued 17 January 2018 Resolved
Provide gauging report for lazarrette bilge as discussed, three belts athwartship.(12-16 shots)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 18 January 2018
Engineering › Fuel Oil Service System › Tank
Issued 17 January 2018 Resolved
Conduct hydrostatic testing on aft fuel tank.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 5 February 2018
Construction/Loadline › Structures › Transverse Bulkhead
Issued 17 January 2018 Resolved
Crop and renew STBD aft watertight bulkhead to good aluminum as discussed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 25 January 2018
Construction/Loadline › Hull › Stiffener
Issued 8 January 2018 Resolved
Repair fractured starboard rudder frame.
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 31 January 2018
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 8 January 2018 Resolved
Crop and renew clad welded section of forwarded fuel tank.
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 31 January 2018
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 16 August 2017 Resolved
Replace retroreflective tape on 7 lifejackets as ID'd.
Action required: 705 - Other - as specified
Due 30 August 2017
Resolved 6 September 2017
Resolution: Lifejackets had retro renewed as directed.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 16 August 2017 Resolved
Provide (10) additional lifejackets; pax count reduced to 56.
Action required: 705 - Other - as specified
Due 30 August 2017
Resolved 16 August 2017
Resolution: Vessel rep brought down additional lifejackets prior to departure.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 August 2017 Resolved
Replace first aid kit.
Action required: 705 - Other - as specified
Due 30 August 2017
Resolved 16 August 2017
Resolution: Vessel rep bought and brought new kit to boat prior to departure.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 16 August 2017 Resolved
Update Coast Pilot & Lightlist.
Action required: 705 - Other - as specified
Due 30 August 2017
Resolved 6 September 2017
Resolution: Updated 2017 Coast Pilot & Lightlist provided upon follow-up.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 16 August 2017 Resolved
Make permanent repairs to forward fuel tank to satisfaction of attending Marine Inspector.
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 5 February 2018
Resolution: Hydro tested fuel tank
Construction/Loadline › Hull › Bracket
Issued 16 August 2017 Resolved
Make permanent repairs to rudder support gusset to satisfaction of attending Marine Inspector.
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 5 February 2018
Resolution: Replaced both port and starboard rudder tubes and supports
Construction/Loadline › Hull › Weld
Issued 27 January 2016 Resolved
The port/starboard propeller shaft skegs were found cracked approximately 8-12" along the weld. Required backgouge/reweld.
Action required: 705 - Other - as specified
Resolved 27 January 2016
Resolution: Made welds as required.
Stability › Watertight Integrity › General
Issued 25 August 2015 Resolved
Vessel's watertight bulkhead forward of the engine room had penetrations that were not watertight. Vessel must prove proper repairs to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 8 September 2015
Resolved 8 September 2015
Resolution: Vessel made all bulkhead penetrations water tight to the satisfaction of the attending marine inspector.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 25 August 2015 Resolved
Breaker panel in the engine room did not have blanks leaving the panel exposed in three areas. Vessel must make permanent repairs to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 8 September 2015
Resolved 8 September 2015
Resolution: Vessel installed blanks on all exposed areas of breaker panel. Repairs made to the satisfaction of the attending Marine Inspector.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 25 August 2015 Resolved
Vessel did not properly indicate stowage location for required child lifejackets. Vessel must indicate separate stowage and amount for child lifejackets to the satisfaction of attending CG Marine inspector.
Action required: 705 - Other - as specified
Due 8 September 2015
Resolved 8 September 2015
Resolution: Vessel properly indicated Stowage for child life jackets to the satisfaction of attending Marine Inspector.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 25 August 2015 Resolved
Handle for emergency fire pump was broken. Vessel shall make permanent repairs to the satisfaction of attending Marine Inspector.
Action required: 705 - Other - as specified
Due 8 September 2015
Resolved 8 September 2015
Resolution: Handle to the emergency fire pump was replaced to the satisfaction of attending Marine Inspector.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 August 2015 Resolved
Vessel did not have the proper CG approved watertight and properly labeled first aid kit onboard.
Action required: 705 - Other - as specified
Due 8 September 2015
Resolved 8 September 2015
Resolution: Vessel provided proof to attending Marine Inspector of CG approved, watertight, & properly labeled medical kit.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 23 October 2014 Resolved
Provide 02 alcohol test kits on board vsl.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 November 2014
Resolved 4 November 2014
Resolution: Vsl crew provided proof of a testing facility within 02 hours of the vsl''s furthest operating area.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 23 October 2014 Resolved
Properly label fwd lifejacket stowage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 November 2014
Resolved 4 November 2014
Resolution: Vessel crew designated fwd stowage area for spare lifejackets only; no lifejackets stored fwd are accounted for on COI.
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 21 October 2010 Resolved
Vessel was required to have 3- BIIs and 1- B1 according to their COI. Provide Proper fire extinguishers in accordance with COI.
Action required: 705 - Other - as specified
Due 21 November 2010
Resolved 25 March 2011
Resolution: Improper B-I extinguisher was replaced with a B-II extinguisher.
Stability › Watertight Integrity › General
Issued 21 October 2010 Resolved
Repair leak at portside rudder post IAW 176.800
Action required: 705 - Other - as specified
Due 22 November 2010
Resolved 6 January 2011
Resolution: Post was repacked and tightened.
Stability › Watertight Integrity › General
Issued 12 November 2008 Resolved
Repair wire penetration located on the starboard side engine room forward bulkhead.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 December 2008
Resolved 11 December 2008
Resolution: Wire penetration closed with electrician putty and found satisfactory.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 12 November 2008 Resolved
Repair leak on port engine water cooled exhaust piping.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 December 2008
Resolved 11 December 2008
Resolution: Replaced rubber section of water cooled exhaust piping and no leaks found.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 13 November 2007 Resolved
You must undergo a satisfactory hull inspection prior to carrying passengers for hire and to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 December 2007
Resolved 20 November 2007
Resolution: Credit for dry dock given this date.
Electrical › Electrical Distribution System (service) › Switch
Issued 20 September 2006 Resolved
Provide emergency cut out switch for generator start battery iaw 46 CFR 183.380 (i).
Action required: 705 - Other - as specified
Due 4 October 2006
Resolved 10 October 2006
Resolution: Emergency cut out switch installed by the vessel.
Engineering › Bilge Water Management System › Piping
Issued 20 September 2006 Resolved
Provide metallic through hull fittings and metallic positive shut off valves for all installed electric submersible pumps iaw 46 CFR 182.520 (d).
Action required: 705 - Other - as specified
Due 4 October 2006
Resolved 10 October 2006
Resolution: Metallic valves and through hull fittings were installed in all locations.
Construction/Loadline
Issued 8 September 1999 Resolved
Install a visual indicator at the operating station to light whenever an automatic bilge pump is operating.
Condition: Unknown
Due 8 October 1999
Resolved 17 September 1999
Lifesaving
Issued 8 September 1999 Resolved
Provide eight adult sized life preservers on board. Vessel may only carry persons for which there are life preservers.
Condition: Unknown
Due 15 September 1999
Resolved 14 September 1999
Navigation
Issued 8 September 1999 Resolved
Provide up to date chart and light list corrected through the most recent notice to mariners.
Condition: Unknown
Due 15 September 1999
Resolved 14 September 1999
Electrical
Issued 11 September 1998 Resolved
EMERGENCY LIGHTING NOT AUTOMATICALLY ACTIVATED. OWNER TO INSTALL AUTOMATICALLY ACTIVATING EMERGENCY LIGHTS.
Condition: Unknown
Due 11 September 1998
Resolved 11 September 1998
Navigation
Issued 11 September 1998 Resolved
STARBOARD RUDDER POST NOT ADEQUETLY SECURED. RUDDER POST HAD DROPPED TO NEAR THE END OF THREADING. OWNER TO DISASSEMBLE RUDDER ASSEMBLY, INSPECT POST, RUDDER POST THREADS AND SECURING THREADS. REPLACE OR REPAIR AS NECESSARY TO THE SATISFACTION OF THE OCMI.
Condition: Unknown
Due 11 September 1998
Resolved 11 September 1998
Electrical
Issued 11 September 1998 Resolved
11O VOLT LIGHTING FIXTURE IN FORWARD ACCOMODATION SPACE NOT SECURED TO OVERHEAD. OWNER TO SECURE LIGHTING FIXTURE.
Condition: Unknown
Due 11 September 1998
Resolved 11 September 1998
Accommodation/Occupational Safety
Issued 11 September 1998 Resolved
EXPANDED METAL DECK GRATING ON AFT SWIM PLATFORM MISSING/WASTED. OWNER TO REPLACE OR REPAIR TO THE SATISFACTION OF THE OCMI.
Condition: Unknown
Due 11 September 1998
Resolved 11 September 1998
Electrical
Issued 11 September 1998 Resolved
CIRCUTS NOT LABELED IN PILOT HOUSE ELECTRICAL DISTRIBUTION PANEL. OWNER TOLABEL ALL CIRCUTS IN DISTRIBUTION PANEL.
Condition: Unknown
Due 11 September 1998
Resolved 11 September 1998
Engineering
Issued 11 September 1998 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 11 September 1998
Resolved 11 September 1998
Construction/Loadline
Issued 11 September 1998 Resolved
OPEN PENETRATIONS THROUGH ENGINEROOM HULL ABOVE THE WATERLINE, AND THROUGH FORWARD ENGINE ROOM BULKHEAD. OWNER TO REPAIR TO THE SATISFACTION OF THE OCMI.
Condition: Unknown
Due 11 September 1998
Resolved 11 September 1998
Construction/Loadline
Issued 11 September 1998 Resolved
PITTING AND WASTEAGE IN CENTER KEEL AREA THROUGHOUT VESSEL. OWNER TO INVESTIGATE CAUSE, CROP AND RENEW DAMAGED AREAS TO THE SATISFACTION OF THE OCMI.
Condition: Unknown
Due 11 September 1998
Resolved 11 September 1998
Construction/Loadline
Issued 15 November 1995 Resolved
REPLACE GASKET FOR HATCH LEADING TO FOREPEAK COMPARTMENT.
Condition: Unknown
Due 21 November 1995
Resolved 28 November 1995
Engineering
Issued 15 November 1995 Resolved
REPAIR AFT FUEL TANK AS ORIGINAL PRIOR TO PUTTING IT INTO OPERATION.
Condition: Unknown
Due 21 November 1995
Resolved 28 November 1995
Construction/Loadline
Issued 15 November 1995 Resolved
REPAIR AS ORIGINAL PORT AND STARBOARD (RAW WATER DISCHARGE FROM MDE'S) SPOOL PIECES.
Condition: Unknown
Due 21 November 1995
Resolved 28 November 1995
Electrical
Issued 15 November 1995 Resolved
INSTALL METAL FASTENERS TO HOLD ELECTRICAL WIRING UP THROUGHOUT THE VESSEL.
Condition: Unknown
Due 21 November 1995
Resolved 28 November 1995
Navigation
Issued 20 September 1994 Resolved
MAKE UPDATED CORRECTIONS TO CHART.
Condition: Unknown
Due 27 September 1994
Resolved 21 September 1994
Lifesaving
Issued 20 September 1994 Resolved
PROVIDE JACOBS LADDER TO ASSIST IN MAN OVERBOARD SITUATION.
Condition: Unknown
Due 7 October 1994
Resolved 12 October 1994
Construction/Loadline
Issued 10 November 1993 Resolved
PROVIDE A METALLIC POSITIVE SHUTOFF VALVE AS CLOSE AS POSSIBLE TO THE HULL ON EACH RULE PUMP OVERBOARD DISCHARGE THROUGH HULL PENETRATION, IN WAY OF AFT STEERING COMPARTMENT AND MID-BODY COMPARTMENT.
Condition: Unknown
Due 10 November 1993
Resolved 10 November 1993
Lifesaving
Issued 26 August 1993 Resolved
ATTACH LIGHTS TO L/F'S WITH LINES AT LEAST 18 FT. LONG.
Condition: Unknown
Due 9 September 1993
Resolved 9 September 1993
Navigation
Issued 26 August 1993 Resolved
AT NEXT DRYDOCK, RAISE MASTHEAD LIGHT (OR LOWER SIDE LIGHTS) TO COMPLY WITHAPPLICABLE NAVIGATION RULES GOVERNING VERTICAL SEPARATION OF LIGHTS.
Condition: Unknown
Due 26 August 1993
Resolved 26 August 1993
Engineering
Issued 26 August 1993 Resolved
REATTACH FLAME SCREEN TO FUEL TANK VENT.
Condition: Unknown
Due 9 September 1993
Resolved 9 September 1993
Fire Fighting
Issued 26 August 1993 Resolved
INSTALL NEW GASKET IN HAND PUMP.
Condition: Unknown
Due 9 September 1993
Resolved 9 September 1993
Engineering
Issued 26 August 1993 Resolved
RE-INSTALL CLAMP ON PORT EXHAUST INJECTION PIPE IN LAZARETTE.
Condition: Unknown
Due 9 September 1993
Resolved 9 September 1993
Electrical
Issued 26 August 1993 Resolved
INSTALL BULBS AND GLOBES IN ALL LIGHT FIXTURES, SPECIFICALLY IN CREW'S BERTHING AND THE LAZARETTE.
Condition: Unknown
Due 9 September 1993
Resolved 9 September 1993
Navigation
Issued 17 September 1992 Resolved
PROVIDE CHARTS FOR AREA OF OPERATION._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Navigation
Issued 17 September 1992 Resolved
PROVIDE LIGHT LIST, TIDE TABLE, AND COAST PILOT.
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Construction/Loadline
Issued 17 September 1992 Resolved
PROVE PROPER OPERATION OF HAND PUMP.
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Lifesaving
Issued 17 September 1992 Resolved
REPLACE THREE ORANGE SMOKE DISTRESS SIGNALS.
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Navigation
Issued 20 September 1991 Resolved
PROVE OPERATION OF FATHOMETER.
Condition: Unknown
Due 20 September 1991
Resolved 20 September 1991
Navigation
Issued 20 September 1991 Resolved
DOUBLE NUT OR COTTER PIN STEERING GEAR LINKAGE.
Condition: Unknown
Due 20 September 1991
Resolved 20 September 1991
Construction/Loadline
Issued 20 September 1991 Resolved
CLEAN AND MAKE AVAILABLE FOR INSPECTION BILGE OF FWD STORAGE AREA FWD OF GALLEY.
Condition: Unknown
Due 20 September 1991
Resolved 20 September 1991
Construction/Loadline
Issued 20 September 1991 Resolved
CLEAN AREAS IN WAY OF PORT AND STBD RUDDER POSTS WHERE ALUMINUM IS DELAMINATING AND MAKE AVAILABLE FOR INSPECTION..
Condition: Unknown
Due 20 September 1991
Resolved 20 September 1991
Unknown
Issued 20 September 1991 Resolved
PROVIDE WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 20 September 1991
Resolved 20 September 1991
Electrical
Issued 20 September 1991 Resolved
LABEL CIRCUIT BREAKERS IN BRIDGE BREAKER PANEL.
Condition: Unknown
Due 20 September 1991
Resolved 20 September 1991
Navigation
Issued 20 September 1991 Resolved
PROVIDE BELL FOR VESSEL.
Condition: Unknown
Due 20 September 1991
Resolved 20 September 1991
Electrical
Issued 20 September 1991 Resolved
BY-PASS TOGGLE SWITCH IN EMERGENCY LIGHTING FIXTURES.
Condition: Unknown
Due 20 September 1991
Resolved 20 September 1991
Engineering
Issued 20 September 1991 Resolved
REPAIR FRACTURED BRACKET INBOARD SIDE OF STBD ENGINE.
Condition: Unknown
Due 20 September 1991
Resolved 20 September 1991
Fire Fighting
Issued 20 September 1991 Resolved
REPAIR LEAKING PIPE ON DISCHARGE SIDE OF FIRE PUMP.
Condition: Unknown
Due 20 September 1991
Resolved 20 September 1991
Construction/Loadline
Issued 19 April 1990 Resolved
WELD CRACKS IN JOINTS ON LADDER, STARBOARD OUTER MUFFLER BRACKET AND CENTERLOWER TRANSOM STRINGER IN STEERING COMPARTMENT (03 TOTAL).
Condition: Unknown
Due 19 April 1990
Resolved 19 April 1990
Construction/Loadline
Issued 19 April 1990 Resolved
INSTALL/WELD SUPPORTS TO PORT OUTBOARD MUFFLER TO PORT TRANSOM STRINGERS.
Condition: Unknown
Due 19 April 1990
Resolved 19 April 1990
Engineering
Issued 19 April 1990 Resolved
LABEL BILGE SYSTEM IN ENGINE ROOM.
Condition: Unknown
Due 19 April 1990
Resolved 19 April 1990
Lifesaving
Issued 20 September 1989 Resolved
PROVIDE FOR BUOYANT APPARATUS: 100FT LONG PAINTER, ONE WATERLIGHT (ADDITIONAL), AND ONE FLOAT-FREE LINK FOR 21 PERSONS OR MORE IAW 46 CFR 180.15-5(C)&(D) AND 46 CFR 180.20-1(A)(4).
Condition: Unknown
Due 20 September 1989
Resolved 20 September 1989
Engineering
Issued 20 September 1989 Resolved
PROVIDE SECURING BOLT AND NUT FOR PORT SIDE MAIN ENGINE EXHAUST IN LAZARETTE.
Condition: Unknown
Due 20 September 1989
Resolved 20 September 1989
Lifesaving
Issued 17 September 1987 Resolved
PROVIDE RETRO-REFLECTIVE MATERIAL FOR 1 ADULT LIFE PRESERVER IAW 46 CFR 180.25-25.
Condition: Unknown
Due 17 September 1987
Resolved 17 September 1987
Fire Fighting
Issued 17 September 1987 Resolved
PROVIDE PROOF OF HYDROSTATIC TEST AND RECHARGING TO 2 15LB CO2 FIRE EXTINGUISHERS LAST HYDRO TESTED (1-80), OR PROVE THESE EXTINGUISHERS HAVE BEEN CONTINUOUSLY INSTALLED ABOARD THIS VESSEL SINCE (1-80) AND NEVER BEEN DISCHARGED IAW 46 CFR 147.04.
Condition: Unknown
Due 17 September 1987
Resolved 17 September 1987
Fire Fighting
Issued 17 September 1987 Resolved
SECURELY MOUNT 10LB DC EXTINGUISHER IN FORWARD ACCOMMODATION.
Condition: Unknown
Due 17 September 1987
Resolved 17 September 1987
Electrical
Issued 17 September 1987 Resolved
PROVIDE PROPER LENSES OR OVERHEAD LIGHTS IN FWD ACCOMMODATIONS WHERE PRESENTLY MISSING.
Condition: Unknown
Due 17 September 1987
Resolved 17 September 1987
Deck/Cargo
Issued 17 September 1987 Resolved
PROVE PROPER OPERATION OF AFT LAZARETTE BILGE ALARM, PRESENTLY INOPERABLE.
Condition: Unknown
Due 17 September 1987
Resolved 17 September 1987
Deck/Cargo
Issued 17 September 1987 Resolved
PROVIDE SUITABLE CHECK OR CHECK-STOP VALVES IN THE BILGE PIPING SYSTEM WHERE MISSING IAW 46 CFR 182.25-5(C).
Condition: Unknown
Due 17 September 1987
Resolved 17 September 1987
Documentation
Issued 17 September 1987 Resolved
PROVIDE A CURRENT COPY OF THE VESSEL'S REQUIRED FCC STATION LICENSE AS PER 46 CFR 184.25-1 AND 47 CFR CHAPTER 1.
Condition: Unknown
Due 17 September 1987
Resolved 17 September 1987
Engineering
Issued 22 August 1985 Resolved
REPLACE PVC PIPING FOR PORT AND STARBOARD MAIN ENGINE RAIN WATER PIPING WITH METALIC PIPE BY THE VESSELS NEXT CREDIT DRY DOCKING AND IN NO CASE LATER THAN 31AUG86.
Condition: Unknown
Due 22 August 1985
Resolved 22 August 1985

Casualty record · 1

3 July 2006Routine · role: Involved in a Marine Casualty · activity 2705072
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.