MAURY USCG vessel records Sign in
← All vessels

MOUNTAINEER STAR

MOUNTAINEER STAR is a 1965 passenger vessel (inspected). The Coast Guard has recorded 60 inspections since 1985, most recently in March 2019, along with 89 deficiencies.

Records from 1985 to 2019. Most recent: inspection, 6 March 2019.

Built
1965
Last inspected
6 March 2019
Documentation
Case Pending · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC9106
Flag
UNITED STATES
367776780
Maury page id
psix-45149

Inspections, by type

…with no type recorded11
Years with a record 28 calendar years (1985–2019)
The 60 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)83.1 ft × 24.4 ft × 4.8 ft
Registered tonnagegross 78 / net 53
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDUBUQUE BOAT & BOILER CO · DUBUQUE, IA, UNITED STATES · built 1965
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMILLSBORO, PA
Trade endorsementsCoastwise, unrestricted
DocumentationCase Pending · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it78 - Regulatory (Subpart C or D), Gross Ton
53 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ4344MMSI 367776780 · active · compulsorily equipped · granted 10 March 2017, expires 10 March 2027
WDC9106MMSI 367097650 · expired · compulsorily equipped · granted 8 March 2006, cancelled 14 May 2016 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 60

6 March 2019 Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6638150
20 March 2014 Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4819830
19 December 2011 Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4210955
10 July 2011 Deficiency Check · DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4078662
24 March 2009 Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3447552
8 January 2009 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3390936
23 June 2008 Annual Inspection · MTSA Verification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3246384
5 September 2007 Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3050040
26 March 2007 Annual Inspection · MTSA Verification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2896989
12 July 2006 Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2710319
7 March 2006 Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2598220
2 February 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2578033
2 February 2006 Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2578052
13 November 2005 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2534420
13 November 2005 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2534466
16 October 2005 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2516169
16 October 2005 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2516172
28 September 2005 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2546987
21 July 2005 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2546990
30 March 2005 MTSA Verification · Deficiency Check · COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2321957
27 October 2004 Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2229294
4 October 2004 Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2225990
19 February 2004 Annual Inspection · Hull Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2008927
11 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1963265
1 October 2003 Administrative Inspection
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1937471
26 August 2003 Administrative Inspection
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1887420
10 July 2003 Administrative Inspection
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1841524
20 May 2003 Administrative Inspection
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1813386
2 April 2003 Annual Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1766627
2 April 2002 Annual Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1600160
5 April 2001 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1412250
6 April 2000 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1459571
24 March 1999 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 808305
9 March 1999 Hull Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1395132
10 March 1998 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1439986
22 January 1998 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1390695
17 November 1997 Examination of Repairs
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 779078
12 March 1997 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1430367
4 March 1997 Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1100601
5 February 1997 Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1409638
9 January 1997 Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1097084
13 March 1996 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 884727
22 March 1995 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 868790
13 June 1994 Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1016646
30 March 1994 COI Inspection · Hull Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1359713
1 April 1993 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 835362
6 April 1992 Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 943554
3 April 1992 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1270436
5 April 1991 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1212922
5 April 1990 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 903636
12 March 1990 Examination of Repairs
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1224805
25 April 1989 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1044112
7 April 1989 COI Inspection · Hull Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1349823
5 April 1988 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 893594
28 May 1987 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1025773
7 April 1987 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1328271
7 April 1986 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 998827
23 July 1985 Damage Survey
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 980470
8 May 1985 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1290661
9 April 1985 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 985906

Deficiency record · 89

Fire Fighting › Ventilation Systems › Duct Hatches
Issued 20 March 2014 Resolved
Remove paint from securing devices to enspure topside ventilation closures are operable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 March 2014
Resolved 1 April 2014
Resolution: Verified proper operation after paint removed from closure devices.
Engineering › Bilge Water Management System › Valve
Issued 20 March 2014 Resolved
Service port side bilge valve in E/R due to leaking.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 March 2014
Resolved 1 April 2014
Resolution: Valve found to be exessively worn. Replaced by service rep.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 12 August 2011 Resolved
Remove hazardous conditions resulting from multiple oil leaks on the generator creating a fire and slip hazard due to oil leaking from the engine being blow thruoughout the engine room including onto the exhaust lagging. The leaks are severe enough the reliability of the generator is also a concern.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 August 2011
Engineering › Lubricating Oil Service System › Hose
Issued 10 July 2011 Resolved
In accordance with 46 CFR 182.20-5 (b) (Old -T), Repair or replace the oil pressure gauge for the starboard engine at the operating station. Currently the existing gauge is inoperable.
Condition: Improper/Lack of Maintenance
Due 12 August 2011
Resolved 12 August 2011
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 10 July 2011 Resolved
In accordance with 46 CFR 181.30-10(b) (Old -T), All portable fire extinguishers shall be mounted with a marine grade mounting bracket. Currently, multiple extinguishers do not have approved marine brackets and may become dislodged due to vessel movement, creating a hazard to passengers.
Condition: Improper Installation
Due 12 August 2011
Resolved 12 August 2011
Stability › Watertight Integrity › General
Issued 10 July 2011 Resolved
In accordance with 46 CFR 185.20-15 (Old-T) and 46 CFR 171.124 (Old-T) Repair or replace all hatches in main deck to ensure water tight integrity is maintained while underway. Currently several hatches require maintenance, due to damaged gaskets or damage hardware.
Condition: Improper/Lack of Maintenance
Due 12 August 2011
Resolved 10 July 2011
Stability › Watertight Integrity › General
Issued 10 July 2011 Resolved
In accordance with 46 CFR 182.40-1(a)(3) (Old-T) Remove nonmetallic piping from the thru - hull penetration in the old sewage discharge piping system, install a metallic valve or metal pipe cap. Currently the vessel has PVC piping connected to the steel through hull fitting without a shut off valve.
Condition: Improper Installation
Due 12 August 2011
Resolved 12 August 2011
Electrical › Electrical Distribution System (service) › Switch
Issued 10 July 2011 Resolved
In accordance with 46 CFR 183.10-10 (Old -T), Repair, replace or remove the electrical switch boxes or controllers which can allow uninsulated parts to be inadvertently touched. Currently the switch boxes or controllers in the sewage compartment and water compartment have openings (conduit knock outs) allowing ready access.
Condition: Improper/Lack of Maintenance
Due 12 August 2011
Resolved 12 August 2011
Stability › Watertight Integrity › General
Issued 10 July 2011 Resolved
In accordance with 46 CFR 177.20-1 (Old-T) Provide a plan for approval for a means to prevent the entry of water into the void vents during adverse weather conditions or provide a means to close them. Currently it appears water has been entering the void vents due to excessive water in the fuel compartment and the efforts of crewmembers to plug the vents in the voids.
Condition: Improper Installation
Due 12 August 2011
Resolved 17 August 2011
Resolution: Received an Email from the Master stating the water in the voids was from how they washed the boat. Requested he monitor the situation and change washing procedure as needed. Scanned Email into Misle.
Communications › Alarms/Indicators › Bilge Alarm
Issued 10 July 2011 Resolved
In accordance with 46 CFR 119.530 (a), repair or replace the bilge high level alarm in the void forward of the sewage tank. Currently the installed sensor is damaged and inoperable.
Condition: Improper/Lack of Maintenance
Due 12 August 2011
Resolved 12 August 2011
Lifesaving › Lifebuoys › Serviceable
Issued 24 March 2009 Resolved
Replace ring-lifebouys (x4) IAW 46CFR117.70. Grab-lines deteriorated.
Action required: 705 - Other - as specified
Due 7 April 2009
Resolved 7 April 2009
Engineering › Steering Gear System › Rudder Stock
Issued 8 January 2009 Resolved
Replace all rudder bolts at rudder post flange fittings.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 February 2009
Resolved 21 January 2009
Resolution: rudder bolts replace.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 8 January 2009 Resolved
CLEAN SEWAGE TANK VOID SPACE TO MAKE SPACE READY FOR INTERNAL INSPECTION.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 February 2009
Resolved 21 January 2009
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 8 January 2009 Resolved
REMOVE PROPS AND CONDUCT NON-DESTRUCTIVE TESTS ON PROP/SHAFT KEYWAYS. DYE PENETRANT IS AN ACCEPTABLE METHOD.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 February 2009
Resolved 21 January 2009
Resolution: Non- destructive testing completed and no defects noted in shafting.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 June 2008 Resolved
Replace safety guard over #1 STBD engine drive pulley.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 July 2008
Resolved 20 August 2008
Engineering › Bilge Water Management System › Interface Detector
Issued 23 June 2008 Resolved
Demonstrate proper functioning of bilge high level alarm system (compartments #1-#5). High level must be indicated on bridge via visible and audible indicator. Note: Until this requirement is corrected, a roving watch must monitor compartments #1-#5 for high water level. Log rounds hourly in bridge log while underway.
Action required: 705 - Other - as specified
Due 1 July 2008
Resolved 20 August 2008
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 26 March 2007 Resolved
Ensure all fire extinguishers are mounted.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2007
Resolved 5 September 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 26 March 2007 Resolved
Ensure annual service.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 September 2007
Resolved 6 September 2007
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 26 March 2007 Resolved
Properly store all combustible material from port and starboard engine room vestibules.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2007
Resolved 5 September 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 March 2007 Resolved
Restock first aid kit as needed.
Due 2 April 2007
Resolved 5 September 2007
Construction/Loadline › Structures › Transverse Bulkhead
Issued 26 March 2007 Resolved
Repair corner on starboard side in galley as original where Bondo is present.
Due 9 April 2007
Resolved 6 September 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 26 March 2007 Resolved
Replace globe on light in dining area.
Due 26 April 2007
Resolved 5 September 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 26 March 2007 Resolved
Place cover over damper on PMDE.
Due 9 April 2007
Resolved 5 September 2007
Pollution Prevention/Response › Prevention Equipment › Means of Removal from within Coaming
Issued 26 March 2007 Resolved
Remove oil from bilge pocket under PMDE.
Due 2 April 2007
Resolved 6 September 2007
Electrical › Electric Supply System (service) › Cable
Issued 26 March 2007 Resolved
Clean battery terminals in engine room.
Due 2 April 2007
Resolved 5 September 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 March 2007 Resolved
Place cover on wire panel beneath outlet in engine room.
Due 2 April 2007
Resolved 26 March 2007
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Pump
Issued 26 March 2007 Resolved
Remove all electrical submersible pumps from engine room. Place cap on discharge piping.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 September 2007
Resolved 6 September 2007
Accommodation/Occupational Safety › Washroom/Toilet › Washbasin
Issued 26 March 2007 Resolved
Conduct general housekeeping in female head, under ice machine and reefers in galley.
Due 5 September 2007
Resolved 5 September 2007
Engineering › Bilge Water Management System › Interface Detector
Issued 26 March 2007 Resolved
Repair bilge visual alarm in wheel house.
Action required: 705 - Other - as specified
Due 2 April 2007
Resolved 5 September 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Automatic Heat Detectors
Issued 26 March 2007 Resolved
Prove proper operation of heat detection syststem.
Due 2 April 2007
Resolved 6 September 2007
Electrical › Electric Supply System (service) › Cable
Issued 26 March 2007 Resolved
Hard wire fresh water potable / fresh water pumps in spaces No. 1 and No. 2
Due 2 April 2007
Resolved 5 September 2007
Navigation › Piloting/Steering › Marine Charts
Issued 26 March 2007 Resolved
Provide updated nav charts.
Due 26 April 2007
Resolved 6 September 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 March 2007 Resolved
Remove all dead end wires under console in pilot house.
Due 2 April 2007
Resolved 5 September 2007
Electrical › Lighting (service) › Switch
Issued 26 March 2007 Resolved
Replace light switch cover on stbd forward dining room bulkhead.
Due 2 April 2007
Resolved 5 September 2007
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 26 March 2007 Resolved
Verify job duties for each crew member for emergencies.
Due 2 April 2007
Resolved 6 September 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 26 March 2007 Resolved
Provide evidence of annual service.
Action required: 705 - Other - as specified
Due 9 April 2007
Resolved 6 September 2007
Resolution: Recievd report from [name withheld]. dated 8/27/07 for CO2 service.
Electrical › Electrical Distribution System (service) › Cable
Issued 7 March 2006 Resolved
Replace battery neutral ground cable and installed covers over the existing neutral cables connected to batteries for starting propulsion plant and generators.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 March 2006
Resolved 16 March 2006
Resolution: replaced
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 7 March 2006 Resolved
Install fire proof (A-60) installation in engine room overhead and replace all deck plating bolts in engine room overhead. Make rounds every 30 minutes in engine room, until installation is replaced, and make log entry.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 March 2006
Resolved 16 March 2006
Resolution: renew in overhead
Engineering › Bilge Water Management System › Interface Detector
Issued 7 March 2006 Resolved
Install bilge alarms in voids 1, 2, and 3.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 April 2006
Resolved 7 April 2006
Resolution: Bilge alarm installed and test was satisfactory.
Engineering › Fuel Oil Storage/Transfer System › Flange
Issued 7 March 2006 Resolved
In void #3, repair fuel leak in the fuel supply line to main engines and generators. Clean up fuel spill on the deck.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 March 2006
Resolved 16 March 2006
Resolution: replace
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 March 2006 Resolved
Install lagging on all three engines exhaust piping located in the last aft void.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 March 2006
Resolved 16 March 2006
Resolution: installed
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 30 March 2005 Resolved
Provide a copy of the inland navigation rules on board the vessel.
Condition: Improper/Lack of Maintenance
Due 6 April 2005
Resolved 8 April 2005
Resolution: Nav rules placed on board.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 March 2005 Resolved
Clearly mark stowage location of first aid kit.
Condition: Improper Installation
Due 6 April 2005
Resolved 30 March 2005
Resolution: Stowage location clearly marked.
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 30 March 2005 Resolved
Post a station bill.
Due 6 April 2005
Resolved 30 March 2005
Resolution: Station bill amended to include a total of five crew (originally only listed three crew).
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 30 March 2005 Resolved
Clarify fixed CO2 operating instructions to clearly identify ventilation systems and proper procedures for securing them prior to discharging CO2.
Due 6 April 2005
Resolved 30 March 2005
Resolution: Instructions rewritten - sat.
Electrical › Electric Supply System (service) › Battery Installation
Issued 19 February 2004 Resolved
Provide protective covers for port main engine starting batteries.
Action required: 705 - Other - as specified
Due 1 August 2004
Resolved 27 October 2004
Communications › Alarms/Indicators › Propeller Revolutions Rate Indicator
Issued 19 February 2004 Resolved
Repair port main engine tachometer and lube oil pressure guage at operating station.
Action required: 705 - Other - as specified
Due 1 August 2004
Resolved 10 July 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 19 February 2004 Resolved
Amend fixed CO2 system operating instructions to include securing of ventilation systems.
Action required: 705 - Other - as specified
Due 1 August 2004
Resolved 27 October 2004
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 19 February 2004 Resolved
Provide ventilation closures for engine room natural ventilation ducts.
Due 1 August 2004
Resolved 27 October 2004
Lifesaving › Lifejacket/PFD (General)
Issued 2 April 2003 Resolved
Noted several lifejackets with worn or loose reflective material - corrected on scene. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Due 2 April 2003
Resolved 2 April 2003
Resolution: Corrected on scene. New reflective material applied to lifejackets.
Lifesaving › Lifejacket/PFD (General)
Issued 2 April 2003 Resolved
Noted one lifejacket in need of new stenciling to correct faded markings - corrected on scene. LEGACY COMPONENT DESC: Marking
Condition: Improper/Lack of Maintenance
Due 2 April 2003
Resolved 2 April 2003
Resolution: Corrected on scene. Jacket restenciled.
Lifesaving › Lifejacket/PFD (General)
Issued 2 April 2003 Resolved
Lifejacket international orange coloring was obscured by excessive grime - corrected on scene. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Due 2 April 2003
Resolved 2 April 2003
Resolution: Corrected on scene. Crewman washed lifejacket and removed grime.
Lifesaving › Lifebuoys
Issued 2 April 2003 Resolved
Waterlight battery was not marked with an expiration date - corrected on scene. LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Improper/Lack of Maintenance
Due 2 April 2003
Resolved 2 April 2003
Resolution: Corrected on scene. A new battery was installed and marked with an installation date.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 2 April 2003 Resolved
Provide approved mounting brackets for each portable fire extinguisher on board. LEGACY COMPONENT DESC: Mounting Bracket
Condition: Placed in Improper Service
Due 2 June 2003
Resolved 20 May 2003
Resolution: Authorized to continue using brackets. Must renew brackets as the portable fire extinguishers are renewed.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 2 April 2003 Resolved
All trash receptacles that are not of an approved incombustible material shall be removed from the vessel. LEGACY COMPONENT DESC: Furniture/Furnishings
Condition: Improper Installation
Due 1 October 2004
Resolved 4 October 2004
Resolution: Combustible trashcans removed. Metal trashcans in use now.
Engineering › Bilge Water Management System
Issued 2 April 2003 Resolved
Renew strainers in bilge suctions throughout the vessel. LEGACY COMPONENT DESC: Strainer
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2003
Resolved 25 April 2003
Resolution: Bilge strainers renewed.
Electrical › Electric Supply System (service)
Issued 2 April 2003 Resolved
Provide a corrosion resistant tray for the port most battery in the engine room. LEGACY COMPONENT DESC: Battery Installation
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 May 2003
Resolved 25 April 2003
Resolution: Provided tray.
Accommodation/Occupational Safety › Occupational Safety
Issued 1 April 2003 Resolved
Remove excessive oil from engine room bilges - corrected on scene.
Condition: Improper/Lack of Maintenance
Due 2 April 2003
Resolved 2 April 2003
Resolution: Corrected on scene. Excess oil in engine room bilges was removed.
Construction/Loadline
Issued 5 April 2001 Resolved
REPAIR FRACTURE AND GOUGE ON PORT BOW LOCATED 27 INCHES ABOVE WATERLINE PRIOR TO CARRYING PASSENGERS AND BY 06APR01 TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 6 April 2001
Resolved 7 April 2001
Lifesaving
Issued 22 January 1998 Resolved
42 CANVAS COVERED KAPOK PFD's WERE ROTTED WITH KAPOK SOLIDIFIED. NUMEROUS OTHER SOLID MOLDED PFD's WERE COVERED WITH A BLACK MILDEW WITH MISSING OR FADED REFLECTIVE TAPE.
Condition: Unknown
Due 28 February 1998
Resolved 26 January 1998
Construction/Loadline
Issued 22 January 1998 Resolved
STBD PFD LOCKER HAS HOLES WHERE STEEL WAS WASTED.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Lifesaving
Issued 12 March 1997 Resolved
DEVELOPE SIP INSPECTION CRITERIA FOR RESCUE PLATFORM.
Condition: Unknown
Due 12 March 1997
Resolved 12 March 1997
Navigation
Issued 12 March 1997 Resolved
DEVELOPE SIP INSPECTION CRITERIA FOR STEERING SYSTEM.
Condition: Unknown
Due 12 March 1997
Resolved 12 March 1997
Construction/Loadline
Issued 12 March 1997 Resolved
INSTALL BILGE LEVEL ALARMS IAW 46 CFR 119.530.
Condition: Unknown
Due 12 March 1997
Resolved 12 March 1997
Construction/Loadline
Issued 22 March 1995 Resolved
Remove or plug open pipe passing through aft bulkhead of MSD space.
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Electrical
Issued 22 March 1995 Resolved
Install additional emergency lights in main engine room to properly illuminate escape route.
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Engineering
Issued 22 March 1995 Resolved
Crop and renew wasted fuel tank space vent, stbd side, main deck.
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Engineering
Issued 22 March 1995 Resolved
Properly mark direction of operation for the emergency fuel shutoff valve.
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Construction/Loadline
Issued 22 March 1995 Resolved
Install proper ventilation in the MSD space and the two aft most void spaces as per 46 CFR 177.20-1.
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Electrical
Issued 22 March 1995 Resolved
Remove dead ended wire passing through aft bulkhead of the MSD space.
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Engineering
Issued 30 March 1994 Resolved
Make proper repairs to all MDE exhaust lagging where it is either missing or torn.
Condition: Unknown
Due 30 March 1994
Resolved 30 March 1994
Electrical
Issued 30 March 1994 Resolved
Install machinery guards for all MDE and SSG belts and pulleys.
Condition: Unknown
Due 30 March 1994
Resolved 30 March 1994
Electrical
Issued 30 March 1994 Resolved
Install machinery guard fcr electric fire pump shaft.
Condition: Unknown
Due 30 March 1994
Resolved 30 March 1994
Construction/Loadline
Issued 30 March 1994 Resolved
Plug drain holes in both lavatory floors.
Condition: Unknown
Due 30 March 1994
Resolved 30 March 1994
Electrical
Issued 30 March 1994 Resolved
Properly bracket MSD raw water pump wiring.
Condition: Unknown
Due 30 March 1994
Resolved 30 March 1994
Electrical
Issued 30 March 1994 Resolved
Line all MDE and SSG battery boxes with lead or other suitable material in accordance with 46CFR183.05-20(d).
Condition: Unknown
Due 30 March 1994
Resolved 30 March 1994
Fire Fighting
Issued 30 March 1994 Resolved
Make proper repairs to firepump shaft packing leak.
Condition: Unknown
Due 30 March 1994
Resolved 30 March 1994
Engineering
Issued 30 March 1994 Resolved
Properly secure the fuel return line on the SMDE.
Condition: Unknown
Due 30 March 1994
Resolved 30 March 1994
Fire Fighting
Issued 7 April 1987 Resolved
MAKE PERMANENT REPAIRS TO INSTALLED BELT DRIVEN FIRE PUMP AND SHOW PROOF OFPROPER OPERATION AT A MINIMUM OF 40 PSI.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Engineering
Issued 7 April 1987 Resolved
PROPERLY MARK FOREPEAK BILGE SUCTION VALVE REACH ROD.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Engineering
Issued 7 April 1987 Resolved
MAKE PERANENT REPARS TO PORT MAIN ENGINE EXHAUST IN AFT VOID.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Electrical
Issued 9 April 1985 Resolved
SECURE EMERGENCY LIGHT FIXTURE LOCATED DOWN IN ENGINEROOM. AT PRESENT THE LAMP HOLDER ASSEMBLY IS HELD IN PLACE BY ONLY ONE SCREW.
Condition: Unknown
Due 9 April 1985
Resolved 9 April 1985
Engineering
Issued 9 April 1985 Resolved
FABRICATE SAFETY SHIELDS FOR THE PULLEY/FAN BELT ASSEMBLIES ON THE FRONT OF BOTH MAIN ENGINES AND BOTH GENERATORS.
Condition: Unknown
Due 9 April 1985
Resolved 9 April 1985
Electrical
Issued 9 April 1985 Resolved
LOCATE FUNCTION OF ELECTRICAL WIRE HANGING OUT OF BRIDGE PANEL AND EITHER UTILIZE PROPERLY OR REMOVE.
Condition: Unknown
Due 9 April 1985
Resolved 9 April 1985
Fire Fighting
Issued 9 April 1985 Resolved
INSTALL GAGE ON FIRE PUMP LOCATED DOWN IN ENGINEROOM. AT PRESENT PRESSURE GAGE IS INOPERATIVE.
Condition: Unknown
Due 9 April 1985
Resolved 9 April 1985
Unknown
Issued 9 April 1985 Resolved
INSTALL SAFETY GUARDS ON THE STAND-BY ELECTRICAL GENERATOR. AT PRESENT GUARDS ARE MISSING.
Condition: Unknown
Due 9 April 1985
Resolved 9 April 1985
Electrical
Issued 9 April 1985 Resolved
REMOVE OR INSTALL ALL WIRE SPLICE CONNECTIONS INTO JUNCTION BOXES LOCATED DOWN IN ENGINEROOM.
Condition: Unknown
Due 9 April 1985
Resolved 9 April 1985
Engineering
Issued 9 April 1985 Resolved
MAKE REPAIRS TO BRIDGE PORT ENGINE INDICATING TACH. AT PRESENT TACH IS NOT WORKING.
Condition: Unknown
Due 9 April 1985
Resolved 9 April 1985
Electrical
Issued 9 April 1985 Resolved
CHECK OUT INDICATING LAMPS ON THE STAND-BY ELECTRICAL GENERATOR PANEL LOCATED DOWN IN THE ENGINEROOM. AT PRESENT LAMPS AREN'T FUNCTIONING PROPERLY.
Condition: Unknown
Due 9 April 1985
Resolved 9 April 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.