MAURY USCG vessel records Sign in
← All vessels

MR. RIDGE

MR. RIDGE is a 1997 passenger vessel (inspected). The Coast Guard has recorded 40 inspections since 1997, most recently in January 2025, along with 19 deficiencies, 1 operational control and 3 casualty investigations between 2002 and 2012.

Records from 1997 to 2025. Most recent: inspection, 24 January 2025.

Built
1997
Last inspected
24 January 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ9621
451524
Flag
UNITED STATES
368027780
Maury page id
psix-451524

Inspections, by type

…with no type recorded8
Years with a record 23 calendar years (1997–2025)
The 40 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)137.6 ft × 28.0 ft × 11.5 ft
Registered tonnagegross 96 / net 65
ITC dimensions (L × B × D)137.6 ft × 28.0 ft × 11.5 ft
ITC tonnagegross 299 / net 89
BuilderNEUVILLE BOAT WORKS INC · NEW IBERIA, LA, UNITED STATES · built 1997
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW IBERIA, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 4 October 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it299 - Convention (Subpart B), Gross Ton
96 - Regulatory (Subpart C or D), Gross Ton
89 - Convention (Subpart B), Net Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ9621MMSI 368027780 · active · compulsorily equipped · granted 20 March 2018, expires 20 March 2028
WDE3481MMSI 367339680 · expired · compulsorily equipped · granted 26 February 2008, cancelled 28 April 2018
WCX9267MMSI 367175220 · expired · compulsorily equipped · granted 23 January 1998, cancelled 29 March 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 40

24 January 2025 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8069576
21 February 2024 Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7868066
14 February 2023 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7636846
10 February 2022 Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7393951
10 January 2022 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7378780
21 January 2021 Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7130124
6 February 2020 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6903769
21 November 2019 Examination of Repairs · Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6860254
3 December 2018 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6591378
26 October 2017 COI Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6295580
15 May 2017 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6146732
11 October 2016 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6020334
25 September 2015 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5728892
20 August 2015 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5221467
19 September 2011 Hull Examination · Internal Structural Exam · Re-Inspection · Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4152455
30 August 2011 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4130954
5 August 2011 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4106249
4 January 2011 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3920156
30 December 2010 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3919985
19 November 2010 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3898260
21 September 2010 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3854065
15 September 2010 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3850604
29 October 2008 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3353469
5 January 2006 Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2561261
28 November 2005 Ballast Water Examination · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2541608
15 November 2005 Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2535287
4 March 2005 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2303352
2 September 2004 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2218818
19 November 2003 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1950936
28 April 2003 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1781939
22 November 2002 Damage Survey · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1713095
5 November 2002 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1701396
4 November 2002 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1700915
4 January 2002 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1475471
25 January 2001 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 825433
26 October 2000 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1055167
3 October 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 824815
10 December 1999 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1381751
4 January 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1423113
19 December 1997 Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1443967

Deficiency record · 19

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 February 2024 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to the provisions for a seaworthy hull. Repair cracked weld in Port generator weld.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2024
Resolved 6 March 2024
Resolution: Repaired cracked weld.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 20 August 2015 Resolved
Function test on system found pressure switch inoperable for engine room. Engines or ventilation would not secure when system was energized.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 August 2015
Resolution: Presuure swittch was repaired and tested satisfactory.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 19 September 2011 Resolved
Missing line throwing appliances for standby vessel endorsement. Vessel is not allowed to conduct standby vessel operations until this item(s) are on board, but all other normal operations are authorized.
Action required: 705 - Other - as specified
Resolved 25 October 2011
Resolution: Corrected.
Construction/Loadline › Penetrations › Weld
Issued 19 September 2011 Resolved
Severe pitting on the stbd side stanchion pipe sockets for the aft deck.
Due 19 October 2011
Resolved 28 September 2011
Resolution: Repaired.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 19 September 2011 Resolved
The battery disconnect switches above the batteries on the port side, genset room need to be labeled.
Action required: 705 - Other - as specified
Due 28 October 2011
Resolved 28 September 2011
Resolution: Labeled.
Lifesaving › Lifebuoys › Serviceable
Issued 19 September 2011 Resolved
The ring bouy on the 01 Dk, stbd side was missing a plug and worn. Vsl to replace ring buoy and stencil correctly.
Action required: 705 - Other - as specified
Due 19 October 2011
Resolved 28 September 2011
Resolution: Replaced & Stenciled.
Deck/Cargo › Holds/Tanks › Ventilation Exhaust Outlet
Issued 19 September 2011 Resolved
Flame screens were missing from several flamable cargo tank vents on deck. Vsl to remove all vents and install flame screen.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 October 2011
Resolved 28 September 2011
Resolution: Repaired.
Electrical › Lighting (service) › Lighting Fixture
Issued 29 October 2008 Resolved
Permanently install light over stove in galley.
Action required: 705 - Other - as specified
Due 29 November 2008
Resolved 3 November 2008
Resolution: Installed new stove cover with light attachment.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 29 October 2008 Resolved
Replace OSHA approved safety harnes for man-overboard operations.
Action required: 705 - Other - as specified
Due 29 November 2008
Resolved 3 November 2008
Fire Fighting › Fire Pumps › Pressure
Issued 28 November 2005 Resolved
Provide for fire pump outlet pressure of 60 psi.
Due 28 December 2005
Resolved 30 December 2005
Resolution: Provided new pump.
Engineering › Sea-water System (primary cooling) › Piping
Issued 28 November 2005 Resolved
Renew all wasted engine exhaust cooling piping as indicated.
Action required: 705 - Other - as specified
Due 28 December 2005
Resolved 23 December 2005
Resolution: Piping renewed.
Communications › Radio Communications › EPIRB
Issued 22 November 2002 Resolved
EPIRB battery expired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 November 2002
Resolution: Provided new, registered EPIRB.
Communications › Radio Communications › EPIRB
Issued 22 November 2002 Resolved
Outdated Hydro release for EPIRB.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 November 2002
Resolution: Provided new hydro release.
Navigation › Piloting/Steering
Issued 22 November 2002 Resolved
Missing current pubs and NavRul book. LEGACY COMPONENT DESC: Pubs
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 November 2002
Resolution: Provided required pubs.
Navigation › Piloting/Steering › Marine Charts
Issued 22 November 2002 Resolved
Charts not corrected for area operating.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 November 2002
Resolution: Updated/Corredted charts provided.
Lifesaving › Buoyant Apparatus
Issued 22 November 2002 Resolved
Installed improperly LEGACY COMPONENT DESC: Lifefloat Weak Link
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 November 2002
Resolution: Installed properly.
Construction/Loadline › Hull › Side Shell
Issued 5 November 2002 Resolved
C&R DAMAGED AREA PORT SIDE FIVE FEET ABOVE WATER LINE, TWO FEET IN FRONT OF COLLISION BULKHEAD EXTENDED AFT APPROX. 20 FEET WITH ALL ASSOCIATED INTERNALS. C&R BULL WORKS FROM BOW APPROX. 25 FEET AFT. C&R DAMAGED AREA TO PILOT HOUSE WINDOW OPENINGS AND RENEW BROKEN WINDOWS. SEE NARRITIVE. LEGACY COMPONENT DESC: Side Shell
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 6 December 2002
Resolved 4 March 2005
Resolution: Inspected repairs and found satisfactory.
Construction/Loadline
Issued 3 October 2000 Resolved
INSTALL FWD ANCHOR TO SATISFACTION OF LOCAL CG INSPECTOR.
Condition: Unknown
Due 3 October 2000
Resolved 3 October 2000
Documentation
Issued 19 December 1997 Resolved
PROVIDE ONBOARD A VALID RADIO SAFETY CERTIFICATE.
Condition: Unknown
Due 19 December 1997
Resolved 19 December 1997

Casualty record · 3

4 November 2002Routine · role: Involved in a Marine Casualty · activity 1700915
28 August 2010Routine · role: Involved in a Marine Casualty · activity 3914291
15 April 2012Routine · role: Involved in a Marine Casualty · activity 4298597
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record