AFTON PRINCESS is a 1966 passenger vessel (inspected). The Coast Guard has recorded 14 inspections since 2016, most recently in May 2026, along with 15 deficiencies and 1 operational control.
Records from 2016 to 2026. Most recent: inspection, 5 May 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
DocumentationValid · issued 4 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it63 - Regulatory (Subpart C or D), Gross Ton 42 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
A vessel must be provided with main steering gear that is: of adequate strength and capable of steering the vessel at all service speeds. Make repairs to the cable pulley system.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2025
Resolution: The deficiency was corrected to the satisfaction of a USCG Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 May 2024Resolved
Each ring life buoy on a vessel must:(1) Be approved in accordance with § 160.050 in Subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150 (SOLAS). 2 marine buoyant devices employed on vessel to satisfy the ring life buoy required complement are not approved in accordance with § 160.050. Resolve by 05 July 2024.
Action required: 705 - Other - as specified
Due 5 July 2024
Resolved 20 June 2024
Resolution: 02 approved life buoys placed into service.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 May 2024Resolved
Spanner wrenches must be provided where a 1.5 inch diameter fire hose is required by 181.320(b). A sufficient number of spanner wrenches (1 per hydrant) were not provided.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 May 2024
Resolution: New equipment placed on board.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 2 May 2022Resolved
01 lifejacket needs new retro reflective tape
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 June 2022
Resolution: vessel has more lifejackets than required-this lifejacket was removed from service.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 2 May 2022Resolved
port RPM gauge inoperable
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 July 2022
Resolution: repaired gauges are installed
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 2 May 2022Resolved
unable to conduct MOB drill due to steering cable deficiency
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 May 2022
Resolution: drill conducted
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 May 2022Resolved
unable to test steering due to frayed cable
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2022
Resolution: New cable installed.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 2 May 2022Resolved
diesel fuel tank site gauge valve leaks to the point a collection can has been placed underneath
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 June 2022
Resolution: valve stem was tightened, not leaking anymore. Oil collection can has been removed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2018
Resolved 24 July 2018
Resolution: Watertight door indicator operable.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 June 2018Resolved
Clamp missing on fire pump hose.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2018
Resolved 24 July 2018
Resolution: Clamp added to fire pump. Tested fire pump, no leaks.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 28 June 2018Resolved
01 Fire extinguisher was missed when last service was conducted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2018
Resolved 24 July 2018
Resolution: Fire extinguisher serviced July 2018.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 June 2018Resolved
Lifering needs to have the line replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2018
Resolved 24 July 2018
Resolution: Lifeline replaced on bridge ring buoy.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.