LEGEND is a 1966 passenger vessel (inspected). The Coast Guard has recorded 28 inspections since 2016, most recently in May 2026, along with 40 deficiencies and 4 casualty investigations between 2002 and 2025.

Records from 2002 to 2026. Most recent: inspection, 18 May 2026.

Built
1966
Last inspected
18 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 May 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH2751
Flag
UNITED STATES
Maury page id
psix-45157

Documentation record

Registered dimensions (L × B × D)71.4 ft × 22.3 ft × 7.6 ft
Registered tonnagegross 98 / net 75
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLAMINAR WOOD PRODUCTS INC · OXNARD, CA, UNITED STATES · built 1966
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 12 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
75 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

28 inspections, each with its date, unit and type; 40 deficiencies with the resolution recorded against each; 4 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 28

18 May 2026 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8367544
1 August 2025 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8200336
1 August 2025 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8204909
5 May 2025 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8128751
25 April 2025 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8120251
2 December 2024 In-Service Inspection · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8042920
22 October 2024 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8023238
24 January 2024 COI Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7854259
4 December 2023 Internal Structural Exam · Drydock Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7833480
27 July 2023 Construction Oversight · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7855825
10 April 2023 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7666215
10 November 2022 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7594031
18 April 2022 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7433050
17 November 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7351880
12 May 2021 In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7195381
12 May 2021 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7196442
14 April 2021 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7175417
20 March 2021 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7174578
12 March 2020 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6925302
7 November 2019 Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6851236
16 October 2019 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6835995
16 January 2019 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6611188
26 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6548931
13 March 2018 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6371316
16 January 2018 Construction Oversight
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6338790
6 November 2017 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6301555
16 March 2017 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6105941
1 March 2016 DAPI Audit · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5825012

Deficiency record · 40

11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 18 May 2026 Resolved
Be provided with inflatable life raft. of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board. passenger count reduce to 40 to match life raft capacity. 46 CFR 180.202
Action required: 705 - Other - as specified
Due 18 May 2026
Resolved 19 May 2026
Resolution: Defs cleared
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 18 May 2026 Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces and paint lockers. Make vapor tight.46 CFR 177.405
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 May 2026
Resolution: Defs cleared
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 May 2026 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Signs of leakage observed around port rudder post seal. Replace or prove via in-water steering test that seal is not leaking. 46 CFR 182.100
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 May 2026
Resolution: Defs cleared
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 May 2026 Resolved
Each vessel must have adequate emergency lighting fitted along thee of escape to the main deck from all passenger and crew accommodation spaces located below the main deck. MI closed both hatches to the accommodation spaces 46 CFR 183.432
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 May 2026
Resolution: Defs cleared
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 May 2025 Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces a space with a through-hull fitting below the deepest load waterline. Bilge alaram in forepeak not operational. Provide operational bilge alarm. 46 CFR 182.530
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2025
Resolution: Bilge alarm operational
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 May 2025 Resolved
Each nozzle must be of corrosion-resistant material and be capable of being changed between a solid stream and a spray pattern. A nozzle on a vessel of not more than 65 feet in length carrying more than 49 passengers must: (1) Be of a type approved in accordance with approval series 162.027; or (2) Be of a type recognized by the Commandant as being equivalent in performance. Current nozzle onboard vessel is plastic and does not meet 162.027. Provide nozzle that meets 162.027. 46 CFR 181.320(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2025
Resolved 5 May 2025
Resolution: New nozzle installed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 5 May 2025 Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces.Detector in starboard passenger area not operational. Provide operational detector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2025
Resolution: Operational detector provided.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 25 April 2025 Resolved
Both main engines were found without machinery guards on the front belts and pullies. Provide adequate guards to prevent personnel injury.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 May 2025
Resolution: Guards on machinery.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 April 2025 Resolved
The engine room stbd battery bank was found with exposed battery terminals. Provide terminals with protection against shorting out terminal posts.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 May 2025
Resolution: Top for battery bank provided.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 22 January 2025 Resolved
01 ball valve was found to be inoperable. Replace ball valve with new.
Action required: 705 - Other - as specified
Resolved 24 January 2025
Resolution: Received photo of new valve installed.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 18 December 2024 Resolved
Vessel was delivered in 1966 and the current stability letter was issued from a sister vessel built in 1965. A stability test has never been conducted on the actual vessel. Modifications were made and a lightships calculation was submitted to MSC in 1999. Additional modifications / engine replacements have occurred in 2011, 2014, and 2018. Vessel recently added 4 layers of fiberglass / resin to the bottom hull, added numerous structural frames outboard / forward, added 2 layers of plywood to the transom, and added one layer of plywood to the engine room flooring. Vessel is currently re-powering both main engines. Provide all documented weights removed and added to the vessel since the 1999 lightship submission to the Marine Safety Center for stability review.
Action required: 705 - Other - as specified
Resolved 5 March 2025
Resolution: Stability test completed, new stability letter issued.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 December 2024 Resolved
Provide SSD with completed re-power checklist.
Action required: 705 - Other - as specified
Resolved 9 January 2025
Resolution: SSD received re-power check list.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 5 December 2024 Resolved
Unauthorized repairs were made to the transom of the vessel. Provide a written repair plan to correct unauthorized repairs.
Action required: 705 - Other - as specified
Resolved 6 December 2024
Resolution: Repair proposal was received and approved by SSD.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 2 December 2024 Resolved
Vessel completed a re-power of both main engines. Conduct an underway sea trial with marine inspector prior to carrying passengers.
Action required: 705 - Other - as specified
Resolved 25 April 2025
Resolution: Underway sea trial conducted.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 October 2024 Resolved
Vessels deck above the lazarette is leaking. Identify the failure of the deck that is causing the leaking and provide a repair plan for approval. Once the repair plan is approved, complete repairs to the satisfaction of the attending USCG marine inspector. To be completed by next dry docking.
Action required: 705 - Other - as specified
Resolved 5 May 2025
Resolution: Lazz repaired at last drydock.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 October 2024 Resolved
The aft end of the starboard fish hold has significant rot. Identify the extent of the rot and provide a repair plan for approval. Once the repair plan is approved, complete repairs to the satisfaction of the attending USCG marine inspector. To be completed by next dry docking.
Action required: 705 - Other - as specified
Resolved 5 May 2025
Resolution: Fish holkd area renewed.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 21 February 2024 Resolved
Vessel does not have emergency broadcast placard for identified radio. Post a identifying placard and instructions as per 46CFR184.510.
Action required: 705 - Other - as specified
Resolved 5 May 2025
Resolution: Placard provided.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 February 2024 Resolved
Starboard bunk room smoke detector and emergency lighting was not in place. Replace smoke detector and emergency lighting.
Action required: 705 - Other - as specified
Resolved 5 May 2025
Resolution: Smoke detector reploaced and e-lighting operational.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 January 2024 Resolved
Vessel's COI lapsed on 23JAN2024, is restricted from operations, and will required a new COI inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2024
Resolution: Renewed and issued COI.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 27 July 2023 Resolved
Egress drills were conducted on vessel on 25APR25. No modifications were made to the salon tables that obstruct the port and stbd bunk room escape hatches. Submit plans to SSD to modify the tables to prevent egress obstruction.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 July 2025
Resolution: Tables were modified as per plans.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 27 July 2023 Resolved
Provide labels on both sides of all emergency escape hatches.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 May 2025
Resolution: Labels provided.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 27 July 2023 Resolved
The side-shell escape hatch did not open fully in the forward direction. Modify the hatch to fully open in the forward position.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 July 2025
02 - Structural Conditions › N/A - No Subsystem › Permanent means of access
Issued 10 April 2023 Resolved
Small passenger vessels that have overnight accommodations for passengers must comply with the requirements in 46 CFR 177.500; construction/arrangement and means of escape. Your vessel must make the following corrections to meet the regulations: *Current aft berthing secondary egress configuration utilizing a vertical ladder on a vessel of > 65’ is not in compliance with 46 CFR 177.500. *Salon does not have secondary means of egress meeting requirements in 46 CFR 177.500. You must submit plans for approval to the U.S. Coast Guard Officer in Charge of Marine Inspection (OCMI) at the below email addressing all the listed items. Please allow a minimum of thirty (30) days for plan approval prior to making any alterations to your vessel. All vessels are required to comply with the emergency egress requirements by 31DEC2023.
Action required: 705 - Other - as specified
Due 27 December 2023
Resolved 30 July 2025
Resolution: Vessel meets IFR compliance.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 10 November 2022 Resolved
Discovered various "daisy-chained" wires in the crew berthing and galley. Remove all "daisy-chained" wires from the vessel.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 10 November 2022
Resolution: Wires were removed in front of inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 November 2022 Resolved
Junction box below stairs in crew berthing found to be missing cover. Install new cover. Cite: 46 CFR 183.01-15(a) (Old T).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 December 2022
Resolved 21 February 2024
Resolution: Observed new cover
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 12 May 2021 Resolved
Vessel experienced small fire within the galley oven. It was reported a box of chips was left in the oven, then the oven was turned on. Prove proper operation of oven and stove top heating elements and all associated wiring.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 May 2021
Resolution: All wiring was inspected for griddle and stove top. Faulty oven thermostat was found and additional def was issued.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 12 May 2021 Resolved
Vessel experienced small fire within the galley oven. It was reported a box of chips was left in the oven, then the oven was turned on. Crew expended 04 portable fire extinguishers to extinguish fire. Provide vessel with 03 new fire extinguishers.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 May 2021
Resolution: Global Fire and Safety re-charged 04 fire extinguishers.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 12 May 2021 Resolved
Galley oven thermostat was found to be faulty. Make repairs and prove proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2021
Resolution: Operationally tested oven, all sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 April 2021 Resolved
Clean fuel filter/flame bowls and grease under galley grill.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2021
Resolved 16 April 2021
Resolution: Inspected by attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 April 2021 Resolved
Replace lifering floating light expired battery.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2021
Resolved 19 April 2021
Resolution: Received picture via text on duty phone of new battery.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 April 2021 Resolved
Properly pack bulkhead penetrations from E/R to lazz.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2021
Resolved 16 April 2021
Resolution: Inspected by attending MI.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 14 April 2021 Resolved
Mark emergency escapes in 2" letters "EMERGENCY EXIT - KEEP CLEAR" on both sides.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2021
Resolved 16 April 2021
Resolution: Marking observed by attending MI.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 April 2021 Resolved
Replace 02 plastic garbage cans in galley area with non-combustible garbage cans.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2021
Resolved 19 April 2021
Resolution: New stainless steel garbage cans for galley onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 October 2019 Resolved
Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, and over current protection.
Action required: 705 - Other - as specified
Due 20 January 2020
Resolved 16 April 2021
Resolution: Completed verification of electrical 1-line diagram for AC system.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 October 2019 Resolved
All electrical panels must be in compliance with safety regulations under Code of Federal Regulations and IEEE. Distribution panel in the galley had openings that needed to be blanked. Must rectify deficiency to the satisfaction of the CG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2019
Resolved 7 November 2019
Resolution: All panel openings had blanks installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 October 2019 Resolved
All electrical panels must be in compliance with safety regulations under Code of Federal Regulations and IEEE. 12v Distribution panel in the pilot house needs to be labeled and openings need to be blanked. Must rectify deficiency to the satisfaction of the CG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2019
Resolved 7 November 2019
Resolution: Panel circuits were labeled and openings were balnked off.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 26 September 2018 Resolved
ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0), ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 11 October 2018
Resolution: Verified in VIVS
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 16 March 2017 Resolved
Make E/R compartment watertight. Fwd portion of E/R near the overhead is open to the aft bunkroom space.
Action required: 705 - Other - as specified
Due 16 April 2017
Resolved 28 March 2017
Electrical › Electric Supply System (service) › Cable
Issued 16 March 2017 Resolved
Remove dead end wire IVO CO2 bottles port side E/R.
Action required: 705 - Other - as specified
Due 16 April 2017
Resolved 28 March 2017
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 16 March 2017 Resolved
Prove proper operation of fwd remote fuel shutoff valves.
Action required: 705 - Other - as specified
Due 16 April 2017
Resolved 28 March 2017

Casualty record · 4

17 July 2002Routine · role: Involved in a Marine Casualty · 1 injured · activity 1650300
23 May 2006Routine · role: Involved in a Marine Casualty · activity 2657580
12 May 2021Routine · role: Involved in a Marine Casualty · activity 7196442
1 August 2025Routine · role: Involved in a Marine Casualty · activity 8204909
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.