Records from 2010 to 2021. Most recent: inspection, 11 May 2021.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 May 2021
No resolution recorded
Vessel failed to undergo an Annual Inspection within the 3 months before or after the COI anniversary date. Vessel is currently in dry storage and placed into laid up status. Must complete a COI Renewal prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Certification, verification and control
Issued 7 December 2020
Resolved
The owner or managing operator failed to make the vessel available for the required drydock examination and internal structural examination. Vessel must undergo a satisfactory drydock examination and internal structural examination prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 December 2020
Resolution: Completed satisfactory Drydock Exam and Internal Structural Exam.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 17 December 2019
Resolved
At each initial and subsequent inspection for certification, the marine inspector shall examine all accessible parts of the exterior and interior part of the hull, the watertight bulkheads, and weather deck. Forward bulkhead of engine compartment is not vapor tight. Make forward bulkhead of engine room vapor tight as to contain fire suppression agent.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2019
Resolved 25 December 2019
Resolution: Master submitted photo proving engine compartment is vapor tight.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 17 December 2019
Resolved
Remote fuel shutoff stations shall be marked in at least 1-inch letters indicating purpose of the valve and direction of operation. Current fuel shutoff valve sign is inadequate. Properly label handle of fuel shutoff valve so as to correctly identify valve's purpose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2019
Resolved 27 December 2019
Resolution: Master submitted photo proving fuel shut off valve has been properly labeled.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 December 2019
Resolved
Batteries shall be checked for condition and security of stowage. Properly install hard cover over battery compartment so as to protect batteries from weather elements.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2019
Resolved 25 December 2019
Resolution: Master submitted photo proving batteries are properly protected from the weather elements.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 December 2019
Resolved
All vessels shall be provided with an approved adult type life preserver for each person carried. 02 life preservers did not pass inspection and were condemned. Reduced persons allowed to 42 until 02 new life preservers are provided on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2019
Resolved 27 December 2019
Resolution: Master submitted photo of two new life preservers provided on board.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 17 December 2019
Resolved
It shall be the duty of the master to prepare and post emergency checkoff lists in a conspicuous place accessible to crew and passengers. Emergency instructions shall be updated to include emergency procedures when crew is reduced to 1 Master.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2019
Resolved 27 December 2019
Resolution: Master submitted photo of updated emergency procedures.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 October 2018
Resolved
BOTH THE PROPELLOR AND THE SHAFT HAVE EXPERIENCED ACCELERATED CORROSION THAT HAS RESULTED IN DAMAGE BEYOND THE ACCEPTABLE LIMITS FOR OPERATION. BOTH MUST ME REPLACED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 November 2018
Resolved 16 November 2018
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 October 2018
Resolved
PROVIDE ELECTRICAL DRAWINGS TO LOCAL OCMI TO INCLUDE WIRE SIZE, WIRE RUN LENGTH, AND OVERCURRENT PROTECTION. -REMOVE POWER INVERTER AND ASSOCIATED WIRES.
-PROVIDE VOLTAGE REGULATOR AND AMP METER FOR INSTALLED -SOLAR PANEL CHARGING SYSTEM.
-REMOVE ALL DEAD END WIRING FROM VESSEL AND SUPPORT WIRES AT 18 INCH INTERVALS.
-BOND ALL ELECTRICAL EQUIPMENT TO A COMMON GROUND BY A NORMALLY NO-CURRENT CARRYING CONDUCTOR.
-REMOVE WINGNUTS ON BATTERY TERMINALS AND REPLACE WITH PERMANENT TYPE CONNECTOR.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 November 2018
Resolved 16 November 2018
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 31 October 2018
Resolved
REPAIR FIBERGLASS TABBING THROUGHOUT VESSEL THAT HAS BECOME DELAMINATED.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2018
Resolved 16 November 2018
Engineering › Bilge Water Management System › Pump
Issued 11 April 2018
Resolved
Submersible bilge pump not UL 1113 listed in forward bilge. Replace with UL 1113 listed pump.
Action required: 705 - Other - as specified
Due 24 April 2018
Resolved 24 April 2018
Resolution: New pump installed UL 1113 (Rule 2000)
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 11 April 2018
Resolved
Provide proof of full compliance to 46CFR16 for all crew members including master.
*Current consortium shows master in full compliance and no crew members listed.
Action required: 705 - Other - as specified
Due 17 April 2018
Resolved 17 April 2018
Resolution: Consortium has captain and crew listed.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 11 April 2018
Resolved
Provide waste management plan.
Action required: 705 - Other - as specified
Due 17 April 2018
Resolved 17 April 2018
Resolution: Plan on board.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 11 April 2018
Resolved
Provide 01 Adult Type I PFD. Vessel capacity reduced to 43 persons.
Action required: 705 - Other - as specified
Due 17 April 2018
Resolved 17 April 2018
Resolution: New PFD added to vessel.
Electrical › Electric Supply System (service) › Battery Installation
Issued 11 April 2018
Resolved
Provide battery tray resistant to corrosive liquids and secure batteries.
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 17 April 2018
Resolution: Tray installed and batteries secured.
Fire Fighting › Fire Bucket › Quantity
Issued 11 April 2018
Resolved
Provide 03 2.5gal fire buckets with lanyards.
Action required: 705 - Other - as specified
Due 17 April 2018
Resolved 17 April 2018
Resolution: Three buckets on board.
Fire Fighting › Semiportable CO2 Fire Extinguishers › Service
Issued 11 April 2018
Resolved
All fire fighting equipment shall be annually serviced by qualified servicing facility. Last serviced on Jan2017.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2018
Resolution: All equipment has been serviced.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 11 April 2018
Resolved
Pre-engineered fixed fire fighting system must be capable of automatically shutting down all power ventilation.
Action required: 705 - Other - as specified
Due 17 April 2018
Resolved 17 April 2018
Resolution: Verified shutdown on ventalation.
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 10 February 2017
Resolved
Make engine compartment vapor tight to contain fire suppression agent
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2017
Resolution: gaps were filled in with fire suppression foam
Accommodation/Occupational Safety › Ventilation › General
Issued 10 February 2017
Resolved
Provide two means of ventilation to engine compartment
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2017
Resolution: Additional ventilation created
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 10 February 2017
Resolved
Provide lifeline for life ring
Due 24 February 2017
Resolved 21 April 2017
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 10 February 2017
Resolved
Apply SOLAS tape to the 10 identified PFDs
Condition: Improper/Lack of Maintenance
Due 24 February 2017
Resolved 21 April 2017
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 10 February 2017
Resolved
Provide FCC Safety Certificate
Due 24 February 2017
Resolved 14 February 2017
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 10 February 2017
Resolved
Provide a complete first aid kit
Due 24 February 2017
Resolved 21 April 2017
Electrical › Electrical Distribution System (service) › Cable
Issued 10 February 2017
Resolved
Secure all wires and cables
Due 24 February 2017
Resolved 21 April 2017
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 10 February 2017
Resolved
Provide proof of enrollment in chemical testing program
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2017