MAURY USCG vessel records Sign in
← All vessels

LEE

LEE is a 1966 passenger vessel (inspected). The Coast Guard has recorded 43 inspections since 1984, most recently in July 2009, along with 24 deficiencies.

Records from 1984 to 2009. Most recent: inspection, 17 July 2009.

Built
1966
Last inspected
17 July 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCS5353
Flag
UNITED STATES
—
Maury page id
psix-45166

Inspections, by type

…with no type recorded6
Years with a record 23 calendar years (1984–2009)
The 43 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it11 - Regulatory (Subpart C or D), Gross Ton
10 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 43

17 July 2009 Uninspected Passenger Vessel
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3554222
3 October 2005 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2507566
1 August 2005 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2447559
15 April 2005 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2331859
28 June 2004 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2116027
26 May 2004 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2078059
6 May 2003 Annual Inspection · Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1786998
7 April 2003 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1769781
14 May 2002 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1616214
30 October 2001 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1420611
8 May 2001 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1399624
5 May 2000 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1421860
27 October 1999 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1411989
27 April 1999 Deficiency Check · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1446760
27 April 1998 Re-Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1381203
5 May 1997 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1445201
21 October 1996 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1383357
10 May 1996 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1445078
27 April 1995 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1430035
13 March 1995 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1360027
14 May 1994 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1394113
21 May 1993 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 828939
10 May 1993 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 831266
23 October 1992 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1256641
1 October 1992 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 958135
12 May 1992 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 955996
30 December 1991 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 960313
30 December 1991 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1314173
8 October 1991 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 932386
11 June 1991 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1017259
8 May 1991 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 928462
16 May 1990 COI Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1241231
19 April 1989 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1204678
11 October 1988 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1197460
26 May 1988 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1204777
19 April 1988 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1344949
14 May 1987 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1334470
31 March 1987 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1327204
3 October 1986 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1314912
23 April 1986 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 999633
18 April 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1289973
1 April 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 982833
4 October 1984 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1283508

Deficiency record · 24

Engineering › Steering Gear System › Rudder Bearing
Issued 15 August 2005 Resolved
Rudder post leaking water excessively.
Condition: Improper/Lack of Maintenance
Due 14 September 2005
Resolved 3 October 2005
Resolution: Rudder packing was tightened.
Personnel › Manning/Qualifications › Medical Fitness
Issued 15 August 2005 Resolved
Owner/Operator has suffered a collapsed lung and surgery for same. Operator was having difficulty breathing and was unable to perform safety drills. Vessel must carry deckhand until operator is medically fit to operate as single operator as per COI.
Due 31 March 2006
Resolved 15 November 2006
Resolution: Vessel COI surrendered. Drills requirement removed.
Lifesaving › Lifefloat › Markings
Issued 15 August 2005 Resolved
Name of vessel not stenciled on lifefloat.
Condition: Unknown
Due 14 September 2005
Resolved 3 October 2005
Resolution: Vessel name stenciled on lifefloat.
Fire Fighting › Fire Bucket › Availability
Issued 15 August 2005 Resolved
Vessel does not have fire buckets onboard.
Condition: Unknown
Due 14 September 2005
Resolved 3 October 2005
Resolution: Fire buckets provided onboard vessel.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 15 August 2005 Resolved
Fixed CO2 fire extinguishing bottle not onboard. Restricted from carriage of passengers.
Due 14 September 2005
Resolved 3 October 2005
Resolution: Fixed CO2 fire extinguishing bottle serviced and reinstalled on vessel. Restriction removed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 15 August 2005 Resolved
Vessel does not have portable fire extinguishers onboard. Restricted from carriage of passengers.
Due 14 September 2005
Resolved 3 October 2005
Resolution: Fire extinguishers serviced and reinstalled on vessel. Restriction removed.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 15 August 2005 Resolved
Vessel has several gallons of used engine oil in common bilge. Oil was observed around automatic bilge pumps. Restricted vessel from carriage of passengers.
Due 14 September 2005
Resolved 3 October 2005
Resolution: Bilges were cleaned of excess oil. No further oil in or around automatic bilge pumps.
Lifesaving
Issued 26 May 2004 Resolved
Lifefloat battery light not fully operational. Must tap several times for it to work. LEGACY COMPONENT DESC: Life Floats
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2004
Resolved 26 May 2004
Resolution: Master replaced lifefloat battery.
Documentation › Certificates/Documents › Stability Letter
Issued 26 May 2004 Resolved
Stability letter not posted. LEGACY COMPONENT DESC: Stability Letter
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 June 2004
Resolved 28 June 2004
Resolution: Stability Letter Posted.
Documentation › Certificates/Documents › FCC SSL
Issued 26 May 2004 Resolved
Master had trouble finding FCC Safety Radio Telephony Certicificate. Informed master to post it with his FCC license.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 June 2004
Resolved 28 June 2004
Resolution: FCC Licenses Posted.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 26 May 2004 Resolved
All portable and fixed fire systems were not currently service. All had expired APRIL 2004.
Action required: 705 - Other - as specified
Due 26 May 2004
Resolved 26 May 2004
Resolution: Fire service tech came out and serviced all systems in the presence of the attending marine inspector.
Navigation › Collision/Grounding Avoidance
Issued 6 May 2003 Resolved
Prove proper operation of port running light. LEGACY COMPONENT DESC: Navigation Lights
Due 5 June 2003
Resolved 7 May 2003
Fire Fighting › Miscellaneous Items
Issued 6 May 2003 Resolved
Provide 3 fire buckets labled "FIRE BUCKET" with lanyard to reach the water from the deck. LEGACY COMPONENT DESC: Fire Buckets
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2003
Lifesaving › Buoyant Apparatus
Issued 6 May 2003 Resolved
Provide 2, 4 foot oars in the lifefloat. LEGACY COMPONENT DESC: Oars
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2003
Unknown
Issued 27 April 1999 Resolved
Conduct U/W hull examination.
Condition: Unknown
Due 7 July 1999
Resolved 22 June 1999
Construction/Loadline
Issued 21 October 1996 Resolved
INSTALL NEW KEEL BOLTS AS ORIGINAL.
Condition: Unknown
Due 31 October 1996
Resolved 22 October 1996
Construction/Loadline
Issued 21 October 1996 Resolved
INSTALL NEW HORN TIMBER BOLTS AS ORIGINAL.
Condition: Unknown
Due 31 October 1996
Resolved 22 October 1996
Construction/Loadline
Issued 21 October 1996 Resolved
PULL SIX FASTENERS PORTSIDE.
Condition: Unknown
Due 31 October 1996
Resolved 22 October 1996
Fire Fighting
Issued 10 May 1993 Resolved
Prove that both CO2 portable extinguishers have been hydrostatically testedwithin the last 5 years to the satisfaction of the attending Coast Guard marine inspector.
Condition: Unknown
Due 10 May 1993
Resolved 10 May 1993
Engineering
Issued 8 October 1991 Resolved
RENEW ALL 2 1/2" EXHAUST HOSES ON PORT SIDE AND 2 1/2" X 1' EXHAUST HOSE ON STARBOARD SIDE.
Condition: Unknown
Due 8 December 1991
Resolved 31 December 1991
Navigation
Issued 8 May 1991 Resolved
PROVIDE A SEPARATE CIRCUIT, FUSED AT THE MAIN DISTRIBUTION PANEL FOR VHF RADIO.
Condition: Unknown
Due 8 May 1991
Resolved 8 May 1991
Engineering
Issued 8 May 1991 Resolved
PROVIDE A FUEL SHUTOFF VALVE AT THE ENGINE END OF THE FUEL LINE.
Condition: Unknown
Due 8 May 1991
Resolved 8 May 1991
Electrical
Issued 11 October 1988 Resolved
PROVIDE A TRAY FOR THE BATTERY, OF LEAD OR OTHER SUITABLE MATERIAL RESIST- ANT TO THE DETERIOATING ACTION BY ELECTROLYTE; IN ACCORDANCE WITH 46 CFR 183.05-20(D)
Condition: Unknown
Due 11 October 1988
Resolved 11 October 1988
Lifesaving
Issued 19 April 1988 Resolved
PROVIDE 3 ADDITIONAL ADULT LIFE PRESERVERS FOR A TOTAL OF 22. VESSEL IS NOTTO CARRY MORE THAN 19 TOTAL PEOPLE ON BOARD UNTIL THIS REQUIREMENT IS SATISFIED.
Condition: Unknown
Due 19 April 1988
Resolved 19 April 1988

Ownership record