MAURY USCG vessel records
← All vessels

THE KRAKEN

THE KRAKEN is a 1966 passenger vessel (inspected). The Coast Guard has recorded 15 inspections since 2016, most recently in July 2024, along with 75 deficiencies — 1 with no resolution recorded — and 1 casualty investigation in 2002.

Records from 2002 to 2024. Most recent: inspection, 22 July 2024.

Built
1966
Last inspected
22 July 2024
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 22 July 2024
…with no type recorded1
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDI 9577
Flag
UNITED STATES
Maury page id
psix-45174

Documentation record

Registered dimensions (L × B × D)60.2 ft × 19.3 ft × 5.2 ft
Registered tonnagegross 48 / net 33
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMACHINE & SUPPLY CO INC · BEAUFORT, NC, UNITED STATES · built 1966
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCAPTREE, NY
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it48 - Regulatory (Subpart C or D), Gross Ton
33 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

15 inspections, each with its date, unit and type; 75 deficiencies with the resolution recorded against each; 1 other recorded name, with years; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 15

22 July 2024 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7964428
19 July 2023 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7746505
2 November 2022 In-Service Inspection · Internal Structural Exam · Administrative Inspection · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7584158
28 June 2022 Annual Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7469679
15 April 2021 Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7154841
28 October 2020 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7082873
17 September 2019 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6809240
21 September 2018 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6542209
13 September 2018 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6548634
4 September 2018 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6528234
5 April 2018 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6385997
30 August 2017 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6234324
24 August 2016 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5980085
27 July 2016 Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5954385
1 February 2016 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5807050

Deficiency record · 75

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 July 2024 No resolution recorded
Vessel failed to get a re-inspection within 3 months of its anniversary date.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 August 2024 — due date passed with no resolution recorded
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 July 2023 Resolved
Conduct and log drills prior to the carriage of passengers to include man overboard, fire drill and abandon ship.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 August 2023
Resolved 21 July 2023
Resolution: Drills logged
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 July 2023 Resolved
Log EPIRB tests monthly.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 August 2023
Resolved 21 July 2023
Resolution: EPIRB logged.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 19 July 2023 Resolved
Prove radio has lat & long programed for emergency distress communications.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2023
Resolved 21 July 2023
Resolution: Lat and long programmed in VHF
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 28 June 2022 Resolved
VHF radio not linked with GPS to broadcast location in a distress situation.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 August 2022
Resolved 15 July 2022
Resolution: Owner purchased new radio capable of broadcasting location.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 28 June 2022 Resolved
Repair hole in bulkhead in forward lazarette bulkhead as a result of the removal of the bonding strap.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2022
Resolved 25 August 2022
Resolution: Received notification (photos) from owner the bulkhead has been repaired.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 28 June 2022 Resolved
Secure generator until cooling (raw water) leak is repaired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2022
Resolved 25 August 2022
Resolution: Received notification (video) the generator has been repaired.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 June 2022 Resolved
Repair wire supports in generator space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2022
Resolved 20 July 2022
Resolution: Wires are supported in generator space.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 28 June 2022 Resolved
Fabricate vent covers iwo engine space in case of fixed firefighting deployment.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 August 2022
Resolved 15 July 2022
Resolution: Owner fabricated vent covers for engine space in case of fixed firefighting deployment.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 28 June 2022 Resolved
Life floats not properly affixed to weak link.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 29 June 2022
Resolved 28 June 2022
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 28 June 2022 Resolved
Rescue ladder not appropriate for means of safe rescue. Develop new ladder.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 20 July 2022
Resolution: O/O fabricated new rescue ladder.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 April 2021 Resolved
Prove proper operation of high bildge alarms in FWD compartment and in the Tank Space.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2021
Resolved 7 May 2021
Resolution: MI attended vessel and cleared requirement.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 15 April 2021 Resolved
Provide a valid copy of certificate of documentation
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2021
Resolved 7 May 2021
Resolution: MI attended vessel and cleared requirement.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 15 April 2021 Resolved
Provide a valid FCC Station License.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2021
Resolved 7 May 2021
Resolution: MI attended vessel and cleared requirement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 April 2021 Resolved
Label lockers
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2021
Resolved 7 May 2021
Resolution: MI attended vessel and cleared requirement.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 15 April 2021 Resolved
Post Stability Letter
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2021
Resolved 7 May 2021
Resolution: MI attended vessel and cleared requirement.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 17 September 2019 Resolved
2nd deck railing under repair after top side FRP repairs. Re-install railing IAW 46 CFR 177.35-1
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 September 2019
Resolved 28 October 2020
Resolution: MI attended vessel and noted that this item was resolved.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 September 2019 Resolved
Install lighting wiring on 2nd deck as planned after installing top deck railing
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 September 2019
Resolved 28 October 2020
Resolution: MI attended vessel and noted that this item was resolved.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 17 September 2019 Resolved
Sealant for bulkhead peretration(s) to the engine room was found deteriorated and required to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 September 2019
Resolved 28 October 2020
Resolution: MI attended vessel and noted that this item was resolved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 September 2019 Resolved
Flexible hose used for electric submersible bilge pumps must be IAW 46 CFR 182.520 (f), of suitable construction for its intended service.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 September 2019
Resolved 28 October 2020
Resolution: MI attended vessel and noted that this item was resolved.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 September 2019 Resolved
Re-install lighting wiring on the second deck where lighting is mounted to the railing under repair.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 September 2019
Resolved 28 October 2020
Resolution: MI attended vessel and noted that this item was resolved.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 September 2019 Resolved
Light fixture on the aft deck was found installed with wiring not IAW 46 CFR 183.340(c). AWG No. 14 gauge
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 September 2019
Resolved 28 October 2020
Resolution: MI attended vessel and noted that this item was resolved.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 17 September 2019 Resolved
Emergency instructions do not reflect the equipment and procedures for the plat form inwhich they were drafted for. Update Emergency instructions IAW 46 CFR 185.512 and the relevent equipment and set up on board the vessel.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 September 2019
Resolved 28 October 2020
Resolution: MI attended vessel and noted that this item was resolved.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 17 September 2019 Resolved
Life jacket bins on the 2nd deck not labled with sizes and quantities. Re-label/ stencil life jacket bins.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 September 2019
Resolved 28 October 2020
Resolution: MI attended vessel and noted that this item was resolved.
09 - Working and Living Conditions › 092 - Working Conditions › Stowage of cargo
Issued 17 September 2019 Resolved
Secure deck freezer to prevent movement while the vessel is underway.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 September 2019
Resolved 19 September 2019
Resolution: Vessel Rep. Stated the freezer is normally in brackets on the 2nd deck. The freezer is not secured and out of the way during a maintaenance period.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 September 2018 Resolved
Remove dead end wiring in generator space overhead. 46 CFR 183.01-15
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 October 2018
Resolved 23 October 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 September 2018 Resolved
Provide chaffing protection for flex cooling line to generator. 46 CFR 182.20-5
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2018
Resolved 23 October 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 21 September 2018 Resolved
Generator fuel shut off inoperable. 46 CFR 182.458
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 21 September 2018
Resolution: Repaired while onboard
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 September 2018 Resolved
Main engines fuel shut offs must be properly labeled. 46 CFR 182.458
Action required: 10 - Deficiency Rectified
Resolved 21 September 2018
Resolution: Labeled while onboard
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 September 2018 Resolved
Provide fire fighting servicing report detailing services provided. 46 CFR 176.25-25
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 21 September 2018
Resolution: Provided report while onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 September 2018 Resolved
Engine cooling discharge portside missing valve handle. 46 CFR 182.20-10
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2018
Resolved 23 October 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 September 2018 Resolved
Repair or replace exhaust lagging on both port and starboard engines. 46 CFR 182.20-15
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2018
Resolved 23 October 2018
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 21 September 2018 Resolved
Missing oil discharge placard. 46 CFR 155.450
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 21 September 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 September 2018 Resolved
Portside exhaust flex hose aft must be double clamped. 46 CFR 176.830
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2018
Resolved 23 October 2018
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 21 September 2018 Resolved
Life Floats must be marked with name of vessel and capacity. 46 CFR 180.20.5
Action required: 10 - Deficiency Rectified
Resolved 21 September 2018
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 21 September 2018 Resolved
[name withheld] Float paddles with name of vessel. 46 CFR 180.20.5
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Resolved 21 September 2018
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 21 September 2018 Resolved
Properly mount Life Float painter bracket. 46 CFR 180.20.1
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 21 September 2018
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 21 September 2018 Resolved
Repair Starboard rudder post leak. 46 CFR 176.25.5
Action required: 10 - Deficiency Rectified
Resolved 21 September 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 4 September 2018 Resolved
Seal wireway penetrations through fwd engine room bulkhead.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 4 September 2018
Resolved 4 September 2018
Resolution: Corrected on the spot.
Communications › Radio Communications › EPIRB
Issued 30 August 2017 Resolved
Provide hydro for EPIRB (46CFR180.64)
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 28 September 2017
Resolution: Provided new hydro for EPIRB
Navigation › Piloting/Steering › Marine Charts
Issued 30 August 2017 Resolved
Provide marine chart for area of operation (46CFR184.420(a)(1))
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 28 September 2017
Resolution: Provided
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 30 August 2017 Resolved
Provide 13 adult PFDs, vessel restricted to carrying 60 (57 PAX) total persons. 9/13/2017: 3 PFD's provided, updated to 63 total persons (60pax/3crew).
Action required: 705 - Other - as specified
Due 30 August 2017
Resolved 19 September 2019
Resolution: During annual inspection verrified quantities of adult and child sized PFDs IAW COI for the vessel. All SAT
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 24 August 2016 Resolved
Provide current list of employees enrolled in the Drug and Alcohol Program
Action required: 705 - Other - as specified
Due 7 September 2016
Resolved 16 September 2016
Resolution: Current list of employees enrolled in the Drug and Alcohol program provided.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 24 August 2016 Resolved
Provide copy of 2015 MIS Report.
Action required: 705 - Other - as specified
Due 7 September 2016
Resolved 16 September 2016
Resolution: Copy of 2015 MIS report provided.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 24 August 2016 Resolved
Provide current copy of FCC Safety Certificate. Restricted route to within 1000' from shore.
Action required: 705 - Other - as specified
Due 24 August 2016
Resolved 16 September 2016
Resolution: Current copy of FCC Safety Certificate provided.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 24 August 2016 Resolved
Provide training logs for boat, and update MOB/Fire/and EPIRB Test.
Action required: 705 - Other - as specified
Due 7 September 2016
Resolved 16 September 2016
Resolution: Vessel training logs provided showing proof of current MOB/Fire/ and EPIRB tests.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 24 August 2016 Resolved
Provide copy of Waste Management Plan
Action required: 705 - Other - as specified
Due 7 September 2016
Resolved 16 September 2016
Resolution: Waste Management Plan provided.
Communications › Radio Communications › VHF Radiotelephone
Issued 24 August 2016 Resolved
Program MMSI # into DSC Capable Radio.
Action required: 705 - Other - as specified
Due 7 September 2016
Resolved 16 September 2016
Resolution: MMSI# programmed into DSC capable VHF radio.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 24 August 2016 Resolved
Update labeling on child PFD Stowage.
Action required: 705 - Other - as specified
Due 7 September 2016
Resolved 16 September 2016
Resolution: Child PFD stowage labels renewed and place in service.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 24 August 2016 Resolved
Repair fuel shut down to generator
Action required: 705 - Other - as specified
Due 24 August 2016
Resolved 16 September 2016
Resolution: Manual pull handle wire cable rerouted to ensure generator fuel shutoff valve closes.
Engineering › Sea-water System (primary cooling) › Valve
Issued 24 August 2016 Resolved
Provide shut off valves for raw water intake on main diesel engines.
Action required: 705 - Other - as specified
Due 7 September 2016
Resolved 16 September 2016
Resolution: New raw water intake shut off valves installed on main diesel engines.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 24 August 2016 Resolved
Provide means of securing MSD valve.
Action required: 705 - Other - as specified
Due 7 September 2016
Resolved 16 September 2016
Resolution: Shut off valve installed on MSD piping to secure system.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 24 August 2016 Resolved
Clean engine room bilges of oily mixtures
Action required: 705 - Other - as specified
Due 7 September 2016
Resolved 16 September 2016
Resolution: Engine room bilge oily mixtures cleaned.
Engineering › Steering Gear System › Rudder Stock
Issued 24 August 2016 Resolved
repair/tighten stbd rudder post.
Action required: 705 - Other - as specified
Due 7 September 2016
Resolved 16 September 2016
Resolution: Stbd rudder post tightened preventing ingress of seawater.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 24 August 2016 Resolved
Provide lifeline for RLB (60')
Action required: 705 - Other - as specified
Due 7 September 2016
Resolved 16 September 2016
Resolution: Lifeline (60') provided on RLB.
Engineering › Bilge Water Management System › Strainer
Issued 24 August 2016 Resolved
Provide strainer for tank compartment bilge suction
Action required: 705 - Other - as specified
Due 7 September 2016
Resolved 16 September 2016
Resolution: Bilge suction strainer installed on tank compartment bilge line.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 24 August 2016 Resolved
Provide means of retrieving a passenger from the water.
Action required: 705 - Other - as specified
Due 7 September 2016
Resolved 16 November 2016
Resolution: Means to rerieve a passenger from the water provided.
Documentation › Manifests/Lists › Emergency Checkoff List
Issued 24 August 2016 Resolved
Provide copy of Emergency Check off list in accom space.
Action required: 705 - Other - as specified
Due 7 September 2016
Resolved 16 September 2016
Resolution: Emergency check off list post on board vessel.
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 August 2016 Resolved
repair/replace bonding wire on generator
Action required: 705 - Other - as specified
Due 7 September 2016
Resolved 16 September 2016
Resolution: Bonding wire on generator replaced.
Engineering › Bilge Water Management System › Piping
Issued 24 August 2016 Resolved
Provide reach rod for bilge piping in crash compartment.
Action required: 705 - Other - as specified
Due 7 September 2016
Resolved 16 September 2016
Resolution: Reach rod for crash compartment bilge pipe shut off valve installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 August 2016 Resolved
Replace wire nuts thru-out boat with permanent installation
Action required: 705 - Other - as specified
Due 7 September 2016
Resolved 16 September 2016
Resolution: Wire nuts removed and replaced by permanent type splice connectors.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 24 August 2016 Resolved
Provide proof of enrollment for the North Star III in a DAPI program.
Action required: 705 - Other - as specified
Due 7 September 2016
Resolved 16 September 2016
Resolution: Proof of DAPI program enrollment provided.
Lifesaving › Hand Flares › Quantity
Issued 24 August 2016 Resolved
Provide 12 flares for operation on Limited Coastwise Route. (vessel has 8, requires 4 more) Route is restricted to LBS.
Action required: 705 - Other - as specified
Due 24 August 2016
Resolved 16 September 2016
Resolution: Vessel outfitted with additional 04 flares to fill vessel's full compliment.
Construction/Loadline › Hull › Hull Plating
Issued 27 July 2016 Resolved
Remove plank/fasteners in buttblock 25' from stem, just above the chine on the port side.
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 1 August 2016
Resolution: MI attended vessel and witnessed the condition of the fasteners, all found to be satisfactory
Construction/Loadline › Hull › Hull Plating
Issued 27 July 2016 Resolved
Provide long term plan to replace butt blocks thru-out...that need to be able to drain water.
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 1 August 2016
Resolution: MI attended vessel all found to be satisfactory with plan
Accommodation/Occupational Safety › Ventilation › General
Issued 27 July 2016 Resolved
Provide means to ventilate aft 3 compartments (engine room, fuel tank, and lazarette)
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 1 August 2016
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 27 July 2016 Resolved
Attach bonding wires in lazarette.
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 1 August 2016
Construction/Loadline › Structures › Manhole
Issued 27 July 2016 Resolved
Repair carlin on fwd hatch.
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 1 August 2016
Construction/Loadline › Hull › Hull Plating
Issued 27 July 2016 Resolved
Remove fasteners from port stern corner.
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 27 July 2016
Resolution: cleared on the spot. Monel ring nails in good condition, but wood is wet b/c has FRP over it. O/O is working on plan to attack this (providing ventilation to the space)
Construction/Loadline › Hull › Hull Plating
Issued 27 July 2016 Resolved
Remove FRP overlay from butt blocks on stbd side to inspect wood hull underneath. (also one spot on port side just fwd of deficiency #1)
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 1 August 2016
Operations/Management › Vessel Activity › Other
Issued 27 July 2016 Resolved
Provide annual plan to go thru each space and clean.
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 1 August 2016
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 27 July 2016 Resolved
Clean engine room and fuel compartment bilges.
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 1 August 2016
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 27 July 2016 Resolved
Repair port side fuel shut off valve (wood support gave way)
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 1 August 2016
Construction/Loadline › Hull › Keel
Issued 27 July 2016 Resolved
Replace missing wormshoe amidships.
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 1 August 2016
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 27 July 2016 Resolved
Provide plan to repair stbd upper deck railing and waist. (very loose). Restricted to no pax on upper deck until railing is fixed.)
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 1 August 2016

Casualty record · 1

19 July 2002Routine · role: Involved in a Marine Casualty · activity 1655967
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

MARLIN VI (2002). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.