Records from 2016 to 2026. Most recent: inspection, 7 April 2026.
Inspection history · 21
7 April 2026
Annual Inspection · Vessel Attendance · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8334301
22 April 2025
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8114092
19 July 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8000844
26 June 2024
Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7943273
30 April 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7899520
20 April 2023
COI Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7654937
18 October 2022
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7576593
26 April 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7417474
1 February 2022
Administrative Inspection · Drydock Extension
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7389269
21 April 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7170669
6 July 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6998371
6 July 2020
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6998381
6 May 2019
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6678194
2 March 2018
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6364814
29 January 2018
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6345329
30 October 2017
Examination of Repairs · Administrative Inspection · Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6297798
14 April 2017
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6124427
19 January 2017
Internal Structural Exam · Administrative Inspection · Drydock Extension
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6073530
20 April 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5863190
8 April 2016
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5850233
23 March 2016
Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5839904
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 April 2025
Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 & .65 - Carbon dioxide cylinders forming part of a fixed fire extinguishing system must be maintained as follows:
(1) Cylinders must be retested at least every 12 years. The two CO2 cylinders on board had not been tested within the last 12 years.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 May 2025
Resolution: Hydrostatically tested CO2 bottles (2) - April 2025 - installed on vessel.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 April 2025
Resolved
The owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including...the operation of the fire main system. A coupling in the fire main (located in the main deck overhead just forward of the main accommodation space's aft bulkhead) failed and prevented the testing of the system. The coupling was replaced and the test was successfully conducted by the end of the inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2025
Resolution: Coupling replaced and system successfully tested.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 April 2024
Resolved
System design and installation must be in accordance with the Marine Design, Installation, Operation, and Maintenance Manual approved for the system by the Commandant.
Fire alarm light Cover missing in the engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2024
Resolved 22 April 2025
Resolution: Cover installatin examined.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 30 April 2024
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck.
Starboard ladder well missing markings.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2024
Resolved 27 June 2024
Resolution: MIs verified installation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 April 2024
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations.
Water leak on generator and port main engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2024
Resolved 19 July 2024
Resolution: Cummins replaced the water pump on the port engine and repaired the water pump on the generator.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 20 April 2023
Resolved
The PA system must be audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members. Repair prior to carrying passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 April 2023
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 20 April 2023
Resolved
A vessel must carry a 1st aid kit approved under 46CFR160.041. The aspirin present on board was expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 April 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 April 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers crew, other persons and the vessel from electrical hazards, including fire. Inspection found pilothouse electrical circuit overloaded with multiple multi-outlet strips daisy chained and electrical extension cords utilized to energize exterior deck lighting. Reduce the load on the electrical circuit to only what installed outlets allow and remove extension cords.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 May 2023
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 April 2022
Resolved
The sidelights of vessels of 20 meters or more in length shall be fitted with matt black inboard screens. Inspection found matt black paint fated on PORT and STBD inboard screens.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2022
Resolved 2 May 2022
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 April 2022
Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the emperor urge of which exceeds 150 degree F must be suitably insulated where necessary to prevent injuries. Inspection found exhaust lagging on Generator is missing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2022
Resolved 2 May 2022
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 April 2022
Resolved
Electrical equipment exposed to the weather must be watertight. Inspection found 120v outlet located on STBD side upper aft deck does not have cover for weather protection and shoes signs of being overloaded.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2022
Resolved 2 May 2022
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 21 April 2021
Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with an equivalent contents and instructions. The first aid kit had expired aspirin. Prove to the attending USCG Marine Inspector that no items in the first aid kit are expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2021
Resolved 7 May 2021
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 21 April 2021
Resolved
Conduct and log crew training and drills to include fire drill, man overboard drill, & abandon ship drill in accordance with 46 CFR 185.512, 185.520, and 185.524.
Action required: 10 - Deficiency Rectified
Resolved 21 April 2021
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 21 April 2021
Resolved
Prove proper operation of the port engine room ventilation damper.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2021
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 July 2020
Resolved
Replace/renew wasted engine room fixed CO2 system hose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2020
Resolved 16 September 2020
Resolution: The deficiency was cleared to the satisfaction of a USCG Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 13 July 2020
Resolved
Prove proper operation of emergency fuel shutoffs.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 July 2020
Resolved 13 July 2020
Resolution: The deficiency was cleared to the satisfaction of a USCG Marine Inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 13 May 2019
Resolved
Replace deteriorated deck drain line that penetrates hull in way of engine room space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2019
Resolved 16 May 2019
Resolution: Hose was replaced.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 May 2019
Resolved
Replace deteriorated fire pump suction hose
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2019
Resolved 16 May 2019
Resolution: Hose on suction side for fire pump replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 May 2019
Resolved
Re-stencil vessel name Adult PFDs where name has faded.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2019
Resolved 16 May 2019
Resolution: PFD markings re-stenciled
Fire Fighting › Fire Hoses › Condition
Issued 4 April 2018
Resolved
Hose had multiple leaks.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2018
Resolution: Replaced on scene prior to completion of exam.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 4 April 2018
Resolved
EAP information not posted in common space.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 1 May 2018
Resolved 4 April 2018
Resolution: EAP info printed and posted prior to completion of exam.
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 14 November 2017
Resolved
During DD exam, the port strut cutlass bearing was torn and in need of replacement. Vessel permitted to safety operate on starboard shaft with port shaft secured.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 29 November 2017
Resolution: Received email verification that the cutlass bearing in the port strut bearing had been replaced.
Fire Fighting › Fire Main › Condition
Issued 24 April 2017
Resolved
During operational test, a small leak was identified on the piping within the engineroom. On 23 May 17, 30 day extension was granted to correct deficiency.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 June 2017
Resolved 19 June 2017
Resolution: Recieved email from O/O that the small leak on the firepump piping had been repaired adn oeprational tests were satisfactory.
Fire Fighting › Fire Main › Condition
Issued 24 April 2017
Resolved
During operational tets of firemain, it was discovered the needle on the pressure gauge had fallen off inside the gauge.
Action required: 705 - Other - as specified
Due 24 May 2017
Resolved 23 May 2017
Resolution: Received email that pressure guage had been repaired.
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 13 April 2016
Resolved
Provide a temporary repair proposal for reinforcing wastage on CHT tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2016
Resolved 18 April 2016
Resolution: Received email notification from o/o of the above vessel that they will apply PC-11 epoxy to wasted areas on the CHT tank to reinforce these wasted areas.
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 13 April 2016
Resolved
Provide a permanent repair or tank replacement proposal for CHT tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 20 April 2016
Resolution: Received email with CHT tank replacement proposal. Pending approval, the tank will be replaced prior to the 2017 operating season.