Records from 1985 to 2007. Most recent: inspection, 20 June 2007.
Documentation record
Registered dimensions (L × B × D)42.4 ft × 14.0 ft × 6.1 ft
Registered tonnagegross 25 / net 19
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBRUCE YOUNGQUIST · HOUGHTON, WA, UNITED STATES · built 1966
Hull materialWood
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationExpired · issued 20 February 2004 · expires 28 February 2005
Service, as the file records itUnclassified
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it25 - Regulatory (Subpart C or D), Gross Ton
19 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 20
20 June 2007
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2968030
10 November 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 784724
30 March 1995
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 851078
14 March 1994
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1362936
19 October 1993
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1154320
23 March 1993
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 836066
22 April 1992
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1261811
12 March 1992
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1264198
2 April 1991
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 912440
27 March 1991
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 912576
18 January 1991
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 929618
13 March 1990
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1228277
2 May 1989
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 896904
28 March 1989
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1349773
30 March 1988
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 992229
20 October 1987
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1016503
13 March 1987
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1014235
28 April 1986
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 993730
10 April 1986
Credit Drydock
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1306209
7 June 1985
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1294268
Accommodation/Occupational Safety
Issued 27 March 1991
Resolved
PROVIDE MEANS TO SECURE MSD OVERBOARD VALVE OR SUITABLE SIGN WHILE OPERATING WITHIN THREE MILE LIMIT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 March 1991
Resolved 27 March 1991
Documentation
Issued 27 March 1991
Resolved
PROVIDE COPY OF STABILITY LETTER TO BE POSTED IN PILOT HOUSE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 March 1991
Resolved 27 March 1991
Lifesaving
Issued 13 March 1990
Resolved
PROVIDE ONE ADDITIONAL LIFERING WITH LIGHT & LINE.
Condition: Unknown
Due 13 March 1990
Resolved 13 March 1990
Lifesaving
Issued 13 March 1990
Resolved
REPLACE ALL DETERIATED LINES ON BUOYANT APPARATUS AND LIFERINGS.
Condition: Unknown
Due 13 March 1990
Resolved 13 March 1990
Construction/Loadline
Issued 10 April 1986
Resolved
1. PROVIDE METALLIC VALVE AND HULL FITTING FOR TOILET DISCHARGE AS REQUIRED BY 46 CFR 182.40-1 (A) (3). THIS ITEM TO BE CORRECTED PRIOR TO 4/17/86 TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 10 April 1986
Resolved 10 April 1986