Records from 1997 to 2024. Most recent: inspection, 12 December 2024.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 39
12 December 2024
COI Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8046930
30 January 2024
Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7858213
12 April 2023
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7675786
21 January 2022
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7386369
19 January 2022
Annual Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7382709
24 March 2021
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7167838
28 January 2020
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6898301
16 January 2020
Deficiency Check · COI Inspection · Drydock Exam · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6883880
16 April 2019
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6663729
16 March 2018
Administrative Inspection · Annual Inspection · DAPI Audit · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6398712
9 January 2017
Administrative Inspection · Hull Examination · Internal Structural Exam · Drydock Exam · Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6089310
14 April 2016
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5914521
11 May 2014
Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4897809
3 February 2012
Hull Examination · Internal Structural Exam · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4238033
30 August 2011
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4131452
3 February 2011
DAPI Audit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3938942
11 February 2010
Internal Structural Exam · Hull Examination · Administrative Inspection · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3678409
8 May 2009
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3470582
28 April 2009
Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3462610
4 February 2008
Annual Inspection · Hull Examination · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3141707
27 February 2007
Hull Examination · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2955678
23 March 2006
Hull Examination · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2824005
2 March 2005
Deficiency Check · Hull Examination · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2502501
27 February 2004
Hull Examination · Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2014595
3 March 2003
Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1752227
27 February 2003
Annual Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1752207
18 May 2002
Type not recorded
No type recorded · Station Honolulu · USCG Oceania District (CGD-O) · Activity 1620234
6 March 2002
Annual Inspection · Hull Examination · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1492224
15 February 2001
Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1382136
5 April 2000
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1048325
2 March 2000
COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1369564
27 September 1999
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1343220
26 September 1999
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1346029
23 June 1999
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1193352
4 March 1999
Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1434830
27 February 1998
Hull Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1378310
19 March 1997
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1416467
5 March 1997
Initial Certification · Plan Review "T" Boat · MARPOL Annex V Examination · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1374889
14 January 1997
Initial Construction-Excluding Oversight
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1454397
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 January 2022
Resolved
Missing 10 B:C portable fire extinguisher at operators station. Provide.
46 CFR 181.500(b)
Action required: 10 - Deficiency Rectified
Due 19 January 2022
Resolved 19 January 2022
Resolution: Porvided the required portable fire extinguisher at the operating station.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 24 March 2021
Resolved
Except as noted in paragraph (c) of this section, stations in the maritime service must be licensed by the FCC either individually or by fleet. Vessel does not have valid station license or safety radio certificate. Vessel is restricted to operating no more than 1,000 feet from shore in accordance with 47 CFR 80.933.
47 CFR 80.13 & 80.903
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 January 2022
Resolved 19 January 2022
Resolution: Vsl has a valid FCC Station License.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 January 2020
Resolved
Each ring life buoy on a vessel must be approved in accordance with §160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. The ring life buoy was found to be damaged. Ring life buoy requires replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2020
Resolved 28 January 2020
Resolution: Marine Inspector verified new ring life buoy onboard vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 January 2020
Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018. Found 13 adult and 03 child lifejackets with nonfunctional retroreflective material.
Action required: 10 - Deficiency Rectified
Resolved 16 January 2020
Resolution: Installed new retrorelective tape on 13 adult and 03 child lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 January 2020
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Found 01 adult lifejacket with holes and other deteriorations.
Action required: 10 - Deficiency Rectified
Resolved 16 January 2020
Resolution: Replaced the damaged lifejacket with a new lifejacket.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 16 January 2020
Resolved
Connections must be made to battery terminals with permanent type connectors. Found wing nuts on the battery terminals.
Action required: 10 - Deficiency Rectified
Resolved 16 January 2020
Resolution: Wing nuts were removed and permanent nuts were installed.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 28 April 2009
Resolved
Vessel's high level bilge alarm was not working. Provide proper operation of high level bilge alarm.
Action required: 705 - Other - as specified
Due 12 May 2009
Resolved 8 May 2009
Documentation › Certificates/Documents › FCC SSL
Issued 28 April 2009
Resolved
This deficiency is not for the FCC SSL. Provide valid FCC Safety Radio Certificate.
Action required: 705 - Other - as specified
Due 12 May 2009
Resolved 8 May 2009
Navigation › Piloting/Steering › US Coast Pilot
Issued 4 February 2008
Resolved
Provide current copy of US Coast Pilot for vessel operating area.
Due 18 February 2008
Resolved 17 March 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 February 2008
Resolved
Provide asprin for 1st aid kit.
Due 18 February 2008
Resolved 17 March 2008
Lifesaving › Lifebuoys › Serviceable
Issued 4 February 2008
Resolved
Replace/repair ring buoy (retro tape & lines deteriorated, name faded)
Due 18 February 2008
Resolved 17 March 2008
Lifesaving › Hand Flares › Expired
Issued 23 March 2006
Resolved
Obtain 6 additional red flares
Due 23 April 2006
Resolved 23 March 2006
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 23 March 2006
Resolved
Install retro-reflective tape on lifejackets and lifering
Due 23 April 2006
Resolved 23 March 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 March 2006
Resolved
Replace bulb to navigation lights
Due 23 April 2006
Resolved 23 March 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 March 2006
Resolved
Replace expired first aid equipment (iodine, burl jel, and aspirin)
Due 23 April 2006
Resolved 23 March 2006
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 2 March 2005
Resolved
Conduct drills in the presence of a CG Marine Inspector.
Due 2 April 2005
Resolved 16 March 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 March 2005
Resolved
Obtain new eye wash for fist aid kit.
Due 2 April 2005
Resolved 16 March 2005
Construction/Loadline › Hull › Double Hull
Issued 2 March 2005
Resolved
Test pontoons for new installation and leaks in presence of a CG Marine Inspector.
Due 2 April 2005
Resolved 16 March 2005
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 6 March 2002
Resolved
Provide hand lines for port & stbd pontoons.
Action required: 705 - Other - as specified
Due 14 March 2002
Resolved 7 March 2002
Construction/Loadline
Issued 15 February 2001
Resolved
Vessel failed alternate chamber test in port and starboard tubes. Requiredvessel to pass the alternate chamber test IAW MSO Honolulu Inspection Note #22. _x001C_
Condition: Unknown
Due 15 March 2001
Resolved 19 March 2001
Construction/Loadline
Issued 2 March 2000
Resolved
Vessel failed the altermate chamber test IAW MSO Honolulu Inspection Note #22. Required vessel to pass the alternate chamber test for the forward center tube.
Condition: Unknown
Due 2 March 2000
Resolved 2 March 2000
Construction/Loadline
Issued 4 March 1999
Resolved
Repair baffle in port aft inflation chamber. Repair should be completed IAW manufacturer's instructions and tested to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 4 March 1999
Resolved 4 March 1999