TRIBUTE

TRIBUTE is a 1966 passenger vessel (inspected). The Coast Guard has recorded 34 inspections since 2016, most recently in May 2026, along with 78 deficiencies, 1 operational control and 10 casualty investigations between 2004 and 2025.

Records from 2004 to 2026. Most recent: inspection, 27 May 2026.

Built
1966
Last inspected
27 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDJ5323
Flag
UNITED STATES
Maury page id
psix-45205

Inspections, by type

…with no type recorded4
Years with a record 11 calendar years (2016–2026)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)68.5 ft × 22.2 ft × 5.7 ft
Registered tonnagegross 75 / net 55
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDITTMAR AND DONALDSON · COSTA MESA, CA, UNITED STATES · built 1966
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 25 June 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it75 - Regulatory (Subpart C or D), Gross Ton
55 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 34

27 May 2026 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8381219
9 February 2026 Damage Survey · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8308371
23 September 2025 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8240672
25 June 2025 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8161522
9 June 2025 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8156081
8 June 2025 In-Service Inspection · Damage Survey · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8156764
25 March 2025 COI Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8083986
15 October 2024 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8020752
23 May 2024 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7921857
7 December 2023 Internal Structural Exam · Deficiency Check · Hull Examination · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7828769
27 July 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7871872
5 July 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7734147
5 July 2023 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7741750
25 April 2023 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7675615
13 December 2022 In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7627591
11 September 2022 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7560532
6 July 2022 Damage Survey · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7501086
6 July 2022 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7596130
7 April 2022 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7450203
13 January 2022 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7380118
15 December 2021 Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7368800
31 March 2021 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7166176
9 April 2020 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6934721
30 January 2020 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6962091
10 December 2019 Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6865657
28 October 2019 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6844968
28 October 2019 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6849766
26 September 2019 In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6821596
8 May 2019 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6679507
21 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6545752
15 May 2018 Examination of Repairs · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6415400
14 February 2018 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6354987
19 June 2017 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6173623
27 January 2016 Annual Inspection · Hull Examination · Plan Review "T" Boat
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5804302

Deficiency record · 78

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 May 2026 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines at the tank connection. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. 03 of the vessel's shutoff valve were not operable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2026
Resolution: MI attended vessel to test valves. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 May 2026 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Both generators had open panel with exposed wires. Properly enclose boxes.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2026
Resolved 15 June 2026
Resolution: Received photos of deficiency. All SAT.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 27 May 2026 Resolved
The owner, charterer, master, or managing operator of a vessel carrying overnight passengers shall have a suitable number of watchmen patrol throughout the vessel during the nighttime, whether or not the vessel is underway, to guard against, and give alarm in case of, a fire, man overboard, or other dangerous situation. Vessel watchman system was inoperable, fix watchman system and notify local OCMI. Vessel will have logged rounds every hour until engine room watch system is corrected w/in 14 days.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2026
Resolved 15 June 2026
Resolution: Received photos of deficiency. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 May 2026 Resolved
Electrical equipment must be installed to protect from electrical hazards. Electrical wiring underneath operating station has several exposed and dead-end wires. Properly remove or cover to prevent potential shock or fire hazards.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2026
Resolved 15 June 2026
Resolution: Received photos of deficiency. All SAT.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 May 2026 Resolved
All vessels must have operable navigation lights in accordance with the Navigation Rules. Stern light was inoperable. Provide navigation lights that are following the Navigation Rules. Vessel shall only operate in daylight hours.
Action required: 705 - Other - as specified
Resolved 15 June 2026
Resolution: Received photos of deficiency. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 May 2026 Resolved
Vessel did not have non-conductive matting in front the switchboards. Vessel is to place non-conducting mats or grating shall be provided.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2026
Resolved 15 June 2026
Resolution: Received photos of deficiency. All SAT.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 February 2026 Resolved
Whenever a vessel is to carry out major repairs or alterations affecting the safety or seaworthiness of the vessel, it is the duty of the person in charge to report any contemplated repairs or alterations to the Officer in Charge, Marine Inspection (OCMI). A report was received regarding repairs to the vessel’s planks. A Coast Guard Marine Inspector attended the vessel, observed questionable repairs, and identified concerns in the vicinity of the bow. No additional repairs or alterations shall be conducted without prior authorization from the OCMI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2026
Resolution: All repairs completed as per vessel rep written repair plan.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 9 February 2026 Resolved
Remove failed flooring support framing in forward storage room to assess damage to planking. Provide repair plan to replaced failed flooring support framing.
Action required: 705 - Other - as specified
Resolved 9 April 2026
Resolution: Repairs made and satisfactory sea trial conducted.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 9 February 2026 Resolved
Removed decking in way of forward frames in crew bunk room port and stbd sides to assess failed frame fasteners and cracked frame. Provide repair plan to re-strengthen deck clamp areas.
Action required: 705 - Other - as specified
Resolved 9 April 2026
Resolution: Repairs made and satisfactory sea trial conducted.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 9 February 2026 Resolved
Remove decking in way of forepeak compartment to assess frame-to-deck fastening. Provide repair plan to re-strengthen deck clamp areas.
Action required: 705 - Other - as specified
Resolved 9 April 2026
Resolution: Repairs made and satisfactory sea trial conducted.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 9 February 2026 Resolved
Provide repair plan to add additional longitudinal stringer from storage room and into forepeak.
Action required: 705 - Other - as specified
Resolved 9 April 2026
Resolution: Repairs made and satisfactory sea trial conducted.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 9 February 2026 Resolved
Provide repair plan to stop water ingress at various plank seams.
Action required: 705 - Other - as specified
Resolved 9 April 2026
Resolution: Repairs made and satisfactory sea trial conducted.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 9 February 2026 Resolved
Provide repair plan to address movement of gunwale on bow of vessel.
Action required: 705 - Other - as specified
Resolved 9 April 2026
Resolution: Repairs made and satisfactory sea trial conducted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 June 2025 Resolved
Each ring life buoy on a vessel must: (1) Be approved in accordance with §160.050 in subchapter Q of this chapter, or other standard specified by the Commandant. Each ring life buoy with a floating watertight must have a 3ft lanyard and be attached with a corrosion resistant clip. Port ring buoy is not of an approved type, waterlight lanyard is to short and does not have a clip. 46CFR180.70
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 July 2025
Resolution: Vessel submitted objective evidence attesting to new ring bouy installation
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 25 June 2025 Resolved
Vessel must have a valid bridge-to-bridge certificate on board. Vessel did not have a bridge to bridge certificate. 47CFR80.1001
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 July 2025
Resolution: Vessel submitted bridge-to-bridge certificate
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 25 June 2025 Resolved
Life rafts require servicing. Provide annual servicing report by 26Jun25. 46CFR185.730
Action required: 705 - Other - as specified
Resolved 26 June 2025
Resolution: Vessel provided servicing report
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 20 June 2025 Resolved
Vessel conducted emergency haul out to address multiple areas of water intrusion from the hull. After re-entering the water on 18JUN25, 02 additional areas of water ingress were identified my MSD Santa Barbara marine inspector. New areas of water intrusion identified on 18JUN25 are: Butt-block above chine under bunk 24 / port side AND Butt-block under forward / stbd bunk in forward accommodation space. Vessel departed Ventura Boatyard without marine inspector verifying status of leaking areas identified. Vessel's COI was removed from the vessel on 11JUN25 and is scheduled for a recertification inspection on 25JUN25 at Seaforth Landing. Prior to the 25JUN25 recertification inspection, provide Sector San Diego with objective evidence attesting to any repairs made to address the 02 new areas of water ingress and the current leaking rated of each area.
Action required: 705 - Other - as specified
Resolved 25 June 2025
Resolution: Vessel conducted satisfactory repairs of all identified areas.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 June 2025 Resolved
While at the dock, the vessel is actively making water from a butt-block, stbd side at chine, underneath the forward accommodation staircase. Two frame bays in-way-of butt-block have water trickling downward. Haul vessel out of the water for inspection and submit repair proposal.
Action required: 705 - Other - as specified
Due 12 June 2025
Resolved 18 June 2025
Resolution: Repairs made.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 June 2025 Resolved
While underway, the vessel is making water in the forepeak compartment when the bow digs into swells. Areas of concern are the upper four strakes of planking, both port and stbd sides in the aft end of the compartment. Haul vessel out of the water for inspection and submit repair proposal.
Action required: 705 - Other - as specified
Due 12 June 2025
Resolved 18 June 2025
Resolution: Repairs made.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 9 June 2025 Resolved
The aft watertight bulkhead (collision bulkhead) is not watertight. Significant pass-through of water to the adjacent compartment was observed while filling the forepeak with water. Identify the cause and submit repair proposal.
Action required: 705 - Other - as specified
Due 12 June 2025
Resolved 18 June 2025
Resolution: Repairs made.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 June 2025 Resolved
Plank seam at stbd garboard to strake B plank is making water in the aft end of the storage room adjacent to the forward accommodation space. Haul vessel out of the water for inspection and submit repair proposal.
Action required: 705 - Other - as specified
Due 12 June 2025
Resolved 18 June 2025
Resolution: Repairs made.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 June 2025 Resolved
Partial butt-block in forward accommodation space, stbd side forward of staircase is seeping water. Haul vessel out of the water for inspection and submit repair proposal.
Action required: 705 - Other - as specified
Due 12 June 2025
Resolved 18 June 2025
Resolution: Repairs made.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 25 March 2025 Resolved
While conducting steering tests, both rudders were found to be leaking excessively with water accumulation in the lazarette bilge pockets. Make packing gland adjustments to both rudders to reduce the water accumulation.46CFR 182.610
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2025
Resolution: Received documentation that repairs were complete.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 March 2025 Resolved
Both main engine sea strainers were found unmounted and were supported by the attached flexible hoses. Provide each main engine sea strainer with proper support to prevent movement in all sea conditions. 46CFR 182.420
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2025
Resolution: Received documentation that repairs were complete.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 March 2025 Resolved
Electrical submersible pump found partially disconnected with exposed wiring. Either remove or make permanent installation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2025
Resolution: Received documentation that repairs were complete.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 25 March 2025 Resolved
During the fire drill the two deckhands were not familiar with the location of the Halon pull station and thought it was activated with the galley pull station. The vessel was also found without a life-boatman but did not have training on how to launch a life raft. Conduct remedial training on both and once satisfactory, send a statement that you as Captain of the TRIBUTE found their knowledge of emergency drills satisfactory.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2025
Resolution: Received documentation that remedial training was complete.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 March 2025 Resolved
Fire hose nozzle seized, replace with one IAW 46CFR181
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2025
Resolution: Received documentation that the equipment was updated.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 May 2024 Resolved
Ring buoys must be maintained in accordance with 46CFR160.050. Retro reflective tape was missing from ring buoy on the starboard side of the vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2024
Resolution: Vessel sent pictures of retroreflective tape on the ring buoy
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 May 2024 Resolved
Vessel's must have a life jacket for every person on board. Vessel has 2 un - serviceable life jackets taken out of service and another 7 that needed new retro reflective tape. Vessel is restricted to 41 passengers.
Action required: 705 - Other - as specified
Resolved 8 June 2024
Resolution: Recieved pictures of new lifejackets onboard
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 23 May 2024 Resolved
Vessel must have a valid bridge to bridge certificate. Vessels bridge to bridge certificate was expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 June 2024
Resolution: Rcvd updated document
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 May 2024 Resolved
Machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure and personnel injury. Exhaust has multiple pinholes on muffler and must be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 June 2024
Resolution: Rcvd pictures of repairs to muffler
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 May 2024 Resolved
Machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure and personnel injury. Replace fire pump gauge or repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 July 2024
Resolution: Receievd documentation with properly installed fire pump pressure gauge.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 23 May 2024 Resolved
A hatch cover must be attached to the hatch frame by hinges, chains or other devices of substantial strength to prevent its loss. Until replaced ensure hatch stays secured at all times.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 July 2024
Resolution: Recieved pic of hatch cover with line attached.
07 - Fire Safety › N/A - No Subsystem › Fire patrol
Issued 23 May 2024 Resolved
Integrated smoke detectors were not integrated and did not all set each other off. Troubleshoot and ensure the smoke detectors were integrated. Roving watch was corrected at the time of the inspection but documented.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2024
Resolution: Vessel was able to reset the roving watch system with the technician on the phone and demonstrate the operation prior to us departing the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 July 2023 Resolved
Vessel was unable to start its MDEs or generators. Identify and repair the cause of the failure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 July 2023
Resolution: Batteries and battery charger were replaced. Witnessed satisfactory test.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 April 2023 Resolved
Secondary means of escape from forward, lower bunk room was blocked by two rubber mats, impeding escape. Remove mats and keep escape hatch free of obstructions.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2023
Resolution: Mats removed. Corrected on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 July 2022 Resolved
Port side DC distribution panel behind accommodation bulkhead found to be missing cover. Install cover.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2022
Resolved 22 July 2022
Resolution: Missing cover replaced
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 7 July 2022 Resolved
Vessel decking IWO port side damaged area found to have significant rot and fastener wastage. Remove deck coating for further inspection.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2022
Resolution: local areas arrested and treated w/ West Systems Epoxy.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 7 July 2022 Resolved
Vessel found to have damaged area and wood rot IWO port bow rub rail. Submit repair proposal.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2022
Resolution: Repaired IAW approved repair plan
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 7 July 2022 Resolved
Vessel required to conduct fastener pull in vicinity of damaged area to the satisfaction of marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2022
Resolution: Fastener pull postponed until specified due date on COI as result of vessel overall condition and verified repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 7 April 2022 Resolved
All vessels on an Oceans Route are required to carry twelve (12) distress flares. Vessel only had six (6) rocket parachute flares on board at time of inspection. Vessel route is reduced to a Lakes, Bays and Sounds until six (6) additional rocket parachute, red flame or smoke flares are provided.
Action required: 705 - Other - as specified
Resolved 7 April 2022
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 April 2022 Resolved
Each overnight accommodation space on a vessel with overnight accommodations for passengers must be fitted with an independent modular smoke detection and alarm unit. Forward passenger berthing spaces on the port and starboard side did not have the smoke detection systems. Overnight passenger count is reduced by six (6) persons until deficiency is rectified.
Action required: 705 - Other - as specified
Resolved 7 April 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 April 2022 Resolved
A fire hose with a suitable nozzle must be attached to each fire station on board the vessel. Fire hose and nozzle on the port side were damaged and need to be taken out of service. Must replace in kind to the satisfaction of the CG Marine Inspector. Starboard side hose is still operable and can reach all sections of vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2022
Resolved 29 April 2022
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 7 April 2022 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 7 April 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 April 2022 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed. Crank case re-breather on the starboard main engine was not hooked into the air intake as required by engine manufacturers. Must correct to the satisfaction of the Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2022
Resolved 29 April 2022
04 - Emergency Systems › N/A - No Subsystem › Safe areas
Issued 7 April 2022 Resolved
All emergency exits must not be blocked and allow easy access for all personnel on board. Emergency egress from forward crew space was blocked by rubber floor grating in the galley. Must remove grating of cut around emergency egress spot prior to the next overnight trip.
Action required: 705 - Other - as specified
Resolved 7 April 2022
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 31 March 2021 Resolved
Install port fuel tank bonding wire. Due 30Apr2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 26 April 2021
Resolution: Installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 March 2021 Resolved
Install double hose clamps on fuel transfer pump hose. Due 30Apr2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 26 April 2021
Resolution: Installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 March 2021 Resolved
Secure port side A/C pump to foundation. Due 30Apr2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 26 April 2021
Resolution: Secured.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 31 March 2021 Resolved
Remove fuel from transfer pump containment. Due 30Apr2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 7 May 2021
Resolution: Received photo of fuel removed from containment.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 March 2021 Resolved
Install metallic plugs on fuel filter drains. Due 30Apr2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 26 April 2021
Resolution: Installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 March 2021 Resolved
Tighten bridge A/C panel cover to eliminate air-gap. Due 30Apr2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 26 April 2021
Resolution: Repaired.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 December 2019 Resolved
At each initial & subsequent inspection for certification, reinspection and every other inspection, the MI shall require that all observed unsafe practices & hazardous situations be corrected. Vessel to make forepeak/stem of vessel available for inspection. Make proper repairs to ensure watertight integrity of the hull, vessel forepeak & Aft Watertight Bulkhead in Forepeak as indicated. 46 CFR 176.25-50
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 18 December 2019
Resolved 19 December 2019
Resolution: Yard reef and re-caulked the stem and refastened both sides of the stem. Vessel made repairs to the watertight bulkhead in the forepeak, all appeared satisfactory.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 28 October 2019 Resolved
Provide operational approved fixed fire fighting for engine room. Make testing of system available to USCG.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 November 2019
Resolution: Fire fighting shutdown testing completed.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 28 October 2019 Resolved
Provide certified marine chemist certificate showing engine room is safe for entry.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2019
Resolution: Marine chemist cleared space.
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 26 September 2019 Resolved
Vessels emergency lighting did not actuate upon loss of power to the vessel. Provide passenger and crew accommodations with adequate emergency lighting.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 26 September 2019
Resolution: Vessel rep proved operation of emergency lighting, since vessel was at the pier it was running DC power on inverters instead of batteries preventing the emergency lighting from automatically changing over.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 26 September 2019 Resolved
Re-locate emergency escape labeling to actual hatch.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2019
Resolved 24 October 2019
Resolution: Emergency escape labeling on hatch.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 26 September 2019 Resolved
Remove dead-ended cables from all bunks on vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2019
Resolved 24 October 2019
Resolution: Dead end wires removed from bunks.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 September 2019 Resolved
Remove all hard-wired power strips from vessel. Restore to original outlet configuration.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2019
Resolved 24 October 2019
Resolution: all power strips removed and replaced with gang boxes.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 September 2019 Resolved
Properly mount and provide blank covers for all junction boxes under pilot house console.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2019
Resolved 24 October 2019
Resolution: Blanks provided for all junction boxes under pilot house control.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 September 2019 Resolved
Label all breaker loads in all electrical panels.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2019
Resolved 21 November 2019
Resolution: Received photo's of breaker panels labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 September 2019 Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps. Include generator and shore power breaker ratings.
Action required: 705 - Other - as specified
Due 26 December 2019
Resolved 29 May 2020
Resolution: Attended vessel to conduct spot check of A/C electrical one-line drawing, all sat. Drawing was reviewed by Sector San Diego and placed in electronic and permanent files.
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 26 September 2019 Resolved
While underway or drifting at sea, every vessel shall at all times maintain a proper look-out by sight and hearing. The designated watchmen required by 46 CFR 185.410 cannot preform both roving patrolling and look-out watch simultaneously. Vessel has been instructed to operate with a look-out and watchman while conducting drift operations.
Action required: 10 - Deficiency Rectified
Resolved 26 September 2019
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 8 May 2019 Resolved
Provide alcohol test strips to accommodate 100% of crew testing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 May 2019
Resolution: Provided.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 May 2019 Resolved
Prove proper operation of anchor light.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 May 2019
Resolution: Replaced anchor light.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 8 May 2019 Resolved
Relocate EPIRB to open area to facilitate float free.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 May 2019
Resolution: Relocated EPIRB
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 8 May 2019 Resolved
Relocate spanner wrench for fuel shutoff to outside of machinery space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 May 2019
Resolution: Relocated wrench.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 8 May 2019 Resolved
Install captive rope/chain on MOB ladder to prevent loss of ladder.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 May 2019
Resolution: Rope installed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 8 May 2019 Resolved
Repair starboard side ventilation closure clasp.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 May 2019
Resolution: Repaired vent closure.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 21 September 2018 Resolved
CLSN: Vsl is broadcasting Invalid Call Sign, ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 8 May 2019
Fire Fighting › Fire Pumps › Pressure
Issued 15 May 2018 Resolved
Provide a a gauge for the fire pump
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 15 June 2018
Resolution: Pressure gauge installed in engine room, operationally tested sat.
Documentation › Certificates/Documents › Stability Letter
Issued 15 May 2018 Resolved
Provide upper deck max persons label
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 15 June 2018
Resolution: Max passengers stenciled at top of landing.
Construction/Loadline › Structures › Scuttle
Issued 15 May 2018 Resolved
Service water tight hatch to the lazerette.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 15 June 2018
Resolution: Hatch serviced & chain installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 May 2018 Resolved
Provide proer support for teh wiring every 24"
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 15 June 2018
Resolution: All identified wires supported at -/= 24".
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 May 2018 Resolved
Provide an anchor light
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 15 June 2018
Resolution: Anchor light installed & ops tested.
Stability › Weathertight Integrity › General
Issued 15 May 2018 Resolved
Replace broken bridge window.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 15 June 2018
Resolution: New aft window installed.
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 15 May 2018 Resolved
Provide proper install of F/O sight glass.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 15 June 2018
Resolution: Glass guards installed as well as upper valves on both tanks.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 15 May 2018 Resolved
Provide a lock on the MSD OB valve.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 15 June 2018
Resolution: Operator produced 2 cable locks & demonstrated securing of both heads.

Casualty record · 10

24 September 2004Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2208798
4 February 2005Routine · role: Involved in a Marine Casualty · activity 2288012
4 June 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 2673017
22 September 2007Routine · role: Involved in a Marine Casualty · activity 3075978
13 November 2007Routine · role: Involved in a Marine Casualty · activity 3105812
17 September 2013Routine · role: Involved in a Marine Casualty · activity 4717494
28 October 2019Routine · role: Involved in a Marine Casualty · activity 6849766
6 July 2022Routine · role: Involved in a Marine Casualty · activity 7596130
5 July 2023Routine · role: Involved in a Marine Casualty · activity 7741750
9 June 2025Routine · role: Involved in a Marine Casualty · activity 8156081
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

HOLIDAY (2004–2007). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.