Records from 1985 to 1994. Most recent: inspection, 27 December 1994.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 16
27 December 1994
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 850605
1 June 1993
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1142417
2 April 1992
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1265828
25 March 1992
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 954782
7 June 1991
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1242696
30 April 1991
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 921241
3 May 1990
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1232350
27 March 1990
Re-Inspection · Drydock Extension
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 911370
30 October 1989
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 894740
4 April 1989
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1202571
12 September 1988
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1350005
14 April 1988
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1034573
14 April 1987
Re-Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1331809
26 March 1986
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 997525
26 February 1986
Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 990926
17 April 1985
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1291197
Fire Fighting
Issued 2 April 1992
Resolved
SERVICE PORTABLE FIRE EXTINGUISHERS
Condition: Unknown
Due 2 April 1992
Resolved 2 April 1992
Engineering
Issued 2 April 1992
Resolved
INSTALL A SPARK ARRESTER OR REDESIGN VERTICAL DRY EXHAUST TO ARREST SPARKS.
Condition: Unknown
Due 2 April 1992
Resolved 2 April 1992
Documentation
Issued 2 April 1992
Resolved
CHANGE OR ADD C.O.D. ENDORSEMENT TO READ COASTWISE
Condition: Unknown
Due 2 April 1992
Resolved 2 April 1992
Construction/Loadline
Issued 2 April 1992
Resolved
INSTALL A BUTT BLOCK, FWD MOST COMPT., SECOND BAY AFT, FIRST PLANK OVER CHINE.
Condition: Unknown
Due 2 April 1992
Resolved 2 April 1992
Navigation
Issued 2 April 1992
Resolved
UPDATE CHART OF WORKING AREA
Condition: Unknown
Due 2 April 1992
Resolved 2 April 1992
Navigation
Issued 30 April 1991
Resolved
OBTAIN LIGHTLIST FOR AREA, PRESENTLY MISSING_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Navigation
Issued 30 April 1991
Resolved
OBTAIN UP DATED RULES OF THE ROADS_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Unknown
Issued 30 April 1991
Resolved
REPAIR DRILL HOLES ON MAIN DECK_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Electrical
Issued 30 April 1991
Resolved
BATTERY BOX MOUNTING BOLTS NEED TO BE COATED_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Lifesaving
Issued 30 April 1991
Resolved
MISSING TWO ADULT PFDS_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Lifesaving
Issued 30 April 1991
Resolved
MISSING SIX ORANGE FLARES_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Navigation
Issued 27 March 1990
Resolved
PROVIDE 1990 CURRENT TIDE TABLES FOR ROUTE ON COI
Condition: Unknown
Due 27 March 1990
Resolved 27 March 1990
Lifesaving
Issued 27 March 1990
Resolved
YOU ARE LIMITED TO 30 PASSENGERS UNTIL A TOTAL OF 51 ADULT PFD'S ARE ON BOARD
Condition: Unknown
Due 27 March 1990
Resolved 27 March 1990
Electrical
Issued 14 April 1988
Resolved
CLEAN THE ACCUMMULATED BATTERY ACID PRECIPITATE IN THE BATTERY BOXES.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Accommodation/Occupational Safety
Issued 14 April 1988
Resolved
CHAIN AND LOCK THE DIRECT OVERBOARD PORTION OF THE MSD VALVE, SO AS NOT TO PUMP OVERBOARD. THE MSD MUST ONLY PUMP INTO THE HOLDING TANK.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Documentation
Issued 14 April 1988
Resolved
PROVIDE AN FCC SAFETY CERTIFICATE FOR THE VESSEL.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Navigation
Issued 14 April 1988
Resolved
PROVIDE A CURRENT COAST PILOT
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Electrical
Issued 14 April 1988
Resolved
INSTALL INDICATOR LIGHTS IN PILOTHOUSE TO SHOW WHEN AUTOMATIC BILGE PUMPS ARE WORKING.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Unknown
Issued 14 April 1987
Resolved
PROVIDE VALID FCC DOCUMENT.
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987
Unknown
Issued 14 April 1987
Resolved
PROVIDE SIX RED AND 6 ORANGE, CURRENTLY DATED, DISTRESS SIGNALS.
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987
Unknown
Issued 14 April 1987
Resolved
PROVIDE OPERABLE BILGE PUMP TO #2 VOID.
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987
Unknown
Issued 14 April 1987
Resolved
REMOVE ALL OIL AND DEBRIS FROM BILGE.
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987
Unknown
Issued 14 April 1987
Resolved
PROVIDE APPROVED BILGE DISCHARGE PIPING TO ALL ELECTRIC BILGE PUMPS.
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987
Unknown
Issued 14 April 1987
Resolved
REMOVE MISCELLANEOUS UNUSED WIRE.
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987
Unknown
Issued 14 April 1987
Resolved
PROVIDE 100' PAINTERS TO EACH BUOYANCY APPARATUS.
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987
Unknown
Issued 14 April 1987
Resolved
CHANGE/RENAME BOUYANT APPARATUS.
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987
Unknown
Issued 14 April 1987
Resolved
PROVIDE GROUND WIRE TO FUEL TANK FILL PIPES (2).
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987
Unknown
Issued 14 April 1987
Resolved
PROVE SATISFACTORY STOPPAGE OF LEAK IN WAY OF RUDDER POST.
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987
Unknown
Issued 14 April 1987
Resolved
PROVIDE VALID VESSEL DOCUMENT.
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987