MAURY USCG vessel records Sign in
← All vessels

FREE SPIRIT

FREE SPIRIT is a 1966 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 1985, most recently in December 1994, along with 29 deficiencies.

Records from 1985 to 1994. Most recent: inspection, 27 December 1994.

Built
1966
Last inspected
27 December 1994
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WUR2910
Flag
UNITED STATES
366923390 (licence lapsed)
Maury page id
psix-45206

Inspections, by type

Years with a record 10 calendar years (1985–1994)
The 16 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 32 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it30 - Regulatory (Subpart C or D), Gross Ton
20 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WUR2910MMSI 366923390 · expired · compulsorily equipped · granted 4 February 2004, cancelled 14 June 2014
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 16

27 December 1994 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 850605
1 June 1993 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1142417
2 April 1992 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1265828
25 March 1992 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 954782
7 June 1991 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1242696
30 April 1991 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 921241
3 May 1990 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1232350
27 March 1990 Re-Inspection · Drydock Extension
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 911370
30 October 1989 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 894740
4 April 1989 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1202571
12 September 1988 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1350005
14 April 1988 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1034573
14 April 1987 Re-Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1331809
26 March 1986 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 997525
26 February 1986 Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 990926
17 April 1985 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1291197

Deficiency record · 29

Fire Fighting
Issued 2 April 1992 Resolved
SERVICE PORTABLE FIRE EXTINGUISHERS
Condition: Unknown
Due 2 April 1992
Resolved 2 April 1992
Engineering
Issued 2 April 1992 Resolved
INSTALL A SPARK ARRESTER OR REDESIGN VERTICAL DRY EXHAUST TO ARREST SPARKS.
Condition: Unknown
Due 2 April 1992
Resolved 2 April 1992
Documentation
Issued 2 April 1992 Resolved
CHANGE OR ADD C.O.D. ENDORSEMENT TO READ COASTWISE
Condition: Unknown
Due 2 April 1992
Resolved 2 April 1992
Construction/Loadline
Issued 2 April 1992 Resolved
INSTALL A BUTT BLOCK, FWD MOST COMPT., SECOND BAY AFT, FIRST PLANK OVER CHINE.
Condition: Unknown
Due 2 April 1992
Resolved 2 April 1992
Navigation
Issued 2 April 1992 Resolved
UPDATE CHART OF WORKING AREA
Condition: Unknown
Due 2 April 1992
Resolved 2 April 1992
Navigation
Issued 30 April 1991 Resolved
OBTAIN LIGHTLIST FOR AREA, PRESENTLY MISSING_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Navigation
Issued 30 April 1991 Resolved
OBTAIN UP DATED RULES OF THE ROADS_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Unknown
Issued 30 April 1991 Resolved
REPAIR DRILL HOLES ON MAIN DECK_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Electrical
Issued 30 April 1991 Resolved
BATTERY BOX MOUNTING BOLTS NEED TO BE COATED_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Lifesaving
Issued 30 April 1991 Resolved
MISSING TWO ADULT PFDS_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Lifesaving
Issued 30 April 1991 Resolved
MISSING SIX ORANGE FLARES_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Navigation
Issued 27 March 1990 Resolved
PROVIDE 1990 CURRENT TIDE TABLES FOR ROUTE ON COI
Condition: Unknown
Due 27 March 1990
Resolved 27 March 1990
Lifesaving
Issued 27 March 1990 Resolved
YOU ARE LIMITED TO 30 PASSENGERS UNTIL A TOTAL OF 51 ADULT PFD'S ARE ON BOARD
Condition: Unknown
Due 27 March 1990
Resolved 27 March 1990
Electrical
Issued 14 April 1988 Resolved
CLEAN THE ACCUMMULATED BATTERY ACID PRECIPITATE IN THE BATTERY BOXES.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Accommodation/Occupational Safety
Issued 14 April 1988 Resolved
CHAIN AND LOCK THE DIRECT OVERBOARD PORTION OF THE MSD VALVE, SO AS NOT TO PUMP OVERBOARD. THE MSD MUST ONLY PUMP INTO THE HOLDING TANK.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Documentation
Issued 14 April 1988 Resolved
PROVIDE AN FCC SAFETY CERTIFICATE FOR THE VESSEL.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Navigation
Issued 14 April 1988 Resolved
PROVIDE A CURRENT COAST PILOT
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Electrical
Issued 14 April 1988 Resolved
INSTALL INDICATOR LIGHTS IN PILOTHOUSE TO SHOW WHEN AUTOMATIC BILGE PUMPS ARE WORKING.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Unknown
Issued 14 April 1987 Resolved
PROVIDE VALID FCC DOCUMENT.
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987
Unknown
Issued 14 April 1987 Resolved
PROVIDE SIX RED AND 6 ORANGE, CURRENTLY DATED, DISTRESS SIGNALS.
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987
Unknown
Issued 14 April 1987 Resolved
PROVIDE OPERABLE BILGE PUMP TO #2 VOID.
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987
Unknown
Issued 14 April 1987 Resolved
REMOVE ALL OIL AND DEBRIS FROM BILGE.
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987
Unknown
Issued 14 April 1987 Resolved
PROVIDE APPROVED BILGE DISCHARGE PIPING TO ALL ELECTRIC BILGE PUMPS.
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987
Unknown
Issued 14 April 1987 Resolved
REMOVE MISCELLANEOUS UNUSED WIRE.
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987
Unknown
Issued 14 April 1987 Resolved
PROVIDE 100' PAINTERS TO EACH BUOYANCY APPARATUS.
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987
Unknown
Issued 14 April 1987 Resolved
CHANGE/RENAME BOUYANT APPARATUS.
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987
Unknown
Issued 14 April 1987 Resolved
PROVIDE GROUND WIRE TO FUEL TANK FILL PIPES (2).
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987
Unknown
Issued 14 April 1987 Resolved
PROVE SATISFACTORY STOPPAGE OF LEAK IN WAY OF RUDDER POST.
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987
Unknown
Issued 14 April 1987 Resolved
PROVIDE VALID VESSEL DOCUMENT.
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.