Records from 1997 to 2017. Most recent: inspection, 11 July 2017.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 21
11 July 2017
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6205715
26 March 2007
MTSA Verification · Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2895043
3 March 2006
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2595345
20 January 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2570222
22 March 2005
Annual Inspection · MTSA Verification
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2317008
7 March 2005
Hull Examination · Internal Structural Exam
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2304810
3 March 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2302949
10 February 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2290070
28 October 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2230303
15 July 2004
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2134254
29 April 2004
Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2055537
16 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1967049
18 September 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1918751
6 June 2003
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1810455
18 March 2002
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1598337
15 March 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1412242
30 March 2000
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1404936
18 May 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 802482
9 March 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1388755
16 April 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1368705
14 March 1997
Inclining Experiment · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1458414
Electrical › Electric Generation Source (service) › Generator
Issued 29 April 2004
Resolved
Repair overspeed trip on starboard generator. Test satisfactorily
Action required: 705 - Other - as specified
Due 29 April 2004
Resolved 29 April 2004
Resolution: Overspeed trip adjusted and tested satisfactorily under load
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 29 April 2004
Resolved
Clutch oil supply line on port reduction gear worn through and leaking.
Action required: 705 - Other - as specified
Due 29 April 2004
Resolved 29 April 2004
Resolution: Damaged hose removed and replaced with new hose, starboard supply line also found to be wearing and replaced with new hose.
Engineering
Issued 6 June 2003
Resolved
Liquid mud and methanol pump shafts not turning. LEGACY COMPONENT DESC: Pumps
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2003
Resolution: Shafts turned, and pumps were operable.
Electrical › Lighting (service)
Issued 6 June 2003
Resolved
Lights on all four oil pressure alarms in E/R not burning brightly.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2003
Resolution: Lights left watching properly.
Lifesaving › Rescue Boat Equipment
Issued 6 June 2003
Resolved
Rescue harness and platform not secured to boat.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2003
Resolution: Arrangements made so that both will be secured to vsl in time of emergency.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 18 March 2002
Resolved
Missing engineroom scuttle emergency lighting.
Condition: Design Flaw
Due 1 April 2002
Resolved 1 April 2002
Communications › Alarms/Indicators › Bilge Alarm
Issued 18 March 2002
Resolved
Bilge alarm in tunnel/passageway not working.
Due 1 April 2002
Resolved 1 April 2002
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 18 March 2002
Resolved
Audible alarm not working.
Due 1 April 2002
Resolved 1 April 2002
Communications › Radio Communications
Issued 18 March 2002
Resolved
Not working on emergency power. LEGACY COMPONENT DESC: S-Side Band
Due 1 April 2002
Resolved 1 April 2002
Communications › Radio Communications
Issued 18 March 2002
Resolved
EPIRB does not indicate new owner/operator. LEGACY COMPONENT DESC: EPIRB
Due 1 April 2002
Resolved 29 April 2002
Resolution: Submitted new registration form with correct info.
Documentation › Manuals/Policy Documentation
Issued 18 March 2002
Resolved
Missing 46 CFR SUBCH "L".
Due 1 April 2002
Resolved 1 April 2002
Stability › Watertight Integrity
Issued 18 March 2002
Resolved
Missing required marking on engine room escape scuttle. LEGACY COMPONENT DESC: Scuttle
Due 1 April 2002
Resolved 1 April 2002