MAURY USCG vessel records Sign in
← All vessels

M/V CELESTE ELIZABETH

M/V CELESTE ELIZABETH is a 1997 offshore supply vessel. The Coast Guard has recorded 21 inspections since 1997, most recently in July 2017, along with 12 deficiencies.

Records from 1997 to 2017. Most recent: inspection, 11 July 2017.

Built
1997
Last inspected
11 July 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9184067 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDB7445
452103
Flag
SAINT VINCENT AND THE GRENADINES
338881000 (licence lapsed)
Maury page id
psix-452103

Inspections, by type

…with no type recorded1
Years with a record 12 calendar years (1997–2017)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it443 - Convention (Subpart B), Gross Ton
90 - Regulatory (Subpart C or D), Gross Ton
132 - Convention (Subpart B), Net Ton
50 - Regulatory (Subpart C or D), Net Ton
551 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDB7445MMSI 338881000 · cancelled · compulsorily equipped · granted 23 April 2004, cancelled 9 June 2008
WCX2982MMSI 338881000 · cancelled · compulsorily equipped · granted 7 March 1997, cancelled 3 May 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 21

11 July 2017 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6205715
26 March 2007 MTSA Verification · Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2895043
3 March 2006 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2595345
20 January 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2570222
22 March 2005 Annual Inspection · MTSA Verification
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2317008
7 March 2005 Hull Examination · Internal Structural Exam
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2304810
3 March 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2302949
10 February 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2290070
28 October 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2230303
15 July 2004 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2134254
29 April 2004 Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2055537
16 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1967049
18 September 2003 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1918751
6 June 2003 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1810455
18 March 2002 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1598337
15 March 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1412242
30 March 2000 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1404936
18 May 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 802482
9 March 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1388755
16 April 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1368705
14 March 1997 Inclining Experiment · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1458414

Deficiency record · 12

Electrical › Electric Generation Source (service) › Generator
Issued 29 April 2004 Resolved
Repair overspeed trip on starboard generator. Test satisfactorily
Action required: 705 - Other - as specified
Due 29 April 2004
Resolved 29 April 2004
Resolution: Overspeed trip adjusted and tested satisfactorily under load
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 29 April 2004 Resolved
Clutch oil supply line on port reduction gear worn through and leaking.
Action required: 705 - Other - as specified
Due 29 April 2004
Resolved 29 April 2004
Resolution: Damaged hose removed and replaced with new hose, starboard supply line also found to be wearing and replaced with new hose.
Engineering
Issued 6 June 2003 Resolved
Liquid mud and methanol pump shafts not turning. LEGACY COMPONENT DESC: Pumps
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2003
Resolution: Shafts turned, and pumps were operable.
Electrical › Lighting (service)
Issued 6 June 2003 Resolved
Lights on all four oil pressure alarms in E/R not burning brightly.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2003
Resolution: Lights left watching properly.
Lifesaving › Rescue Boat Equipment
Issued 6 June 2003 Resolved
Rescue harness and platform not secured to boat.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2003
Resolution: Arrangements made so that both will be secured to vsl in time of emergency.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 18 March 2002 Resolved
Missing engineroom scuttle emergency lighting.
Condition: Design Flaw
Due 1 April 2002
Resolved 1 April 2002
Communications › Alarms/Indicators › Bilge Alarm
Issued 18 March 2002 Resolved
Bilge alarm in tunnel/passageway not working.
Due 1 April 2002
Resolved 1 April 2002
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 18 March 2002 Resolved
Audible alarm not working.
Due 1 April 2002
Resolved 1 April 2002
Communications › Radio Communications
Issued 18 March 2002 Resolved
Not working on emergency power. LEGACY COMPONENT DESC: S-Side Band
Due 1 April 2002
Resolved 1 April 2002
Communications › Radio Communications
Issued 18 March 2002 Resolved
EPIRB does not indicate new owner/operator. LEGACY COMPONENT DESC: EPIRB
Due 1 April 2002
Resolved 29 April 2002
Resolution: Submitted new registration form with correct info.
Documentation › Manuals/Policy Documentation
Issued 18 March 2002 Resolved
Missing 46 CFR SUBCH "L".
Due 1 April 2002
Resolved 1 April 2002
Stability › Watertight Integrity
Issued 18 March 2002 Resolved
Missing required marking on engine room escape scuttle. LEGACY COMPONENT DESC: Scuttle
Due 1 April 2002
Resolved 1 April 2002

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.