This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it25337 - Convention (Subpart B), Gross Ton 7602 - Convention (Subpart B), Net Ton 30255 - Dead Weight, Metric Ton 42044 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel
Behind this panel: 10 inspections, each with its date, unit and type; 3 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 10
24 August 2017Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6248846
22 May 2017Ballast Water Examination · ISPS II Exam · COC-GAS Renew
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 March 2016Resolved
0950-Elec Equip in General-PSCO observed numerous electrical connections on cargo deck, in compressor room & machinery room loose with exposed wiring compromising the ability to be intrinsically safe in a gas dangerous zone. Provide report from class attesting to proper repairs prior to resuming discharging operations-a-SOLAS VII/13.1 IGC/10.1.4
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 31 March 2016
Resolution: Received, reviewed and accepted class report from BV stating all compromised electrical fittings have been overhauled or replaced and tested satisfactory.
1870-Special Requirements-PSCO obsv that Emergency Shut Down fusible elements were in a state of disrepair, many of which appeared to be modified with a non approved plug. Provide report from class attesting to proper installation prior to resuming discharging operations-a-SOLAS VII/13.1 IGC/5.6.4
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 31 March 2016
Resolution: Received, reviewed and accepted class report from BV stating all fusible elements were cleaned and paint was removed from elements allowing them to melt as intended in event of fire.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 30 March 2016Resolved
1840-Instrumentation-[name withheld] was unable to calibrate fixed gas detection system. Provide report from class attesting to proper operation prior to resuming discharging operations-a-SOLAS VII/13.1 IGC/13.6.6
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 31 March 2016
Resolution: Received, reviewed and accepted class report from BV stating surveyor witnessed C/O calibrate fixed gas detection unit and it is operating properly.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.