MAURY USCG vessel records Sign in
← All vessels

PARACLETE

PARACLETE is a 1996 passenger vessel (inspected). The Coast Guard has recorded 42 inspections since 1997, most recently in October 2025, along with 39 deficiencies, 1 operational control and 1 casualty investigation in 2019.

Records from 1997 to 2025. Most recent: inspection, 21 October 2025.

Built
1996
Last inspected
21 October 2025
Documentation
Case Pending · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ17960
452149
Flag
UNITED STATES
367162640
Maury page id
psix-452149

Inspections, by type

…with no type recorded3
Years with a record 28 calendar years (1997–2025)
The 42 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)45.0 ft × 14.0 ft × 5.3 ft
Registered tonnagegross 22 / net 17
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderOMNI MARINE CORP · ANACORTES, WA, UNITED STATES · built 1996
Hull materialFRP (Fiberglass)
PropulsionDiesel Direct
Hull shapeShip
Hull configurationMonohull
Hailing portANACORTES, WA
Trade endorsementsCoastwise, unrestricted
DocumentationCase Pending · issued 12 July 2025 · expires 31 July 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it22 - Simplified, Gross Ton
17 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ7960MMSI 367162640 · active · compulsorily equipped · granted 2 November 2017, expires 2 November 2027
WCX3229MMSI 367162640 · expired · voluntarily equipped · granted 25 January 2007, cancelled 20 May 2017
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 42

21 October 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8259272
23 September 2025 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8239305
16 September 2024 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8003716
31 October 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7818699
10 October 2023 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7805725
11 October 2022 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7576112
7 October 2021 Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7327140
12 January 2021 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7122950
17 November 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7097362
24 September 2019 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6816984
9 February 2019 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6636893
3 December 2018 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6591398
30 November 2018 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6589810
8 November 2017 Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6302088
27 December 2016 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6062836
21 December 2016 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6070200
2 December 2015 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5773013
2 October 2014 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4994660
8 June 2012 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4337656
8 December 2011 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4204582
21 January 2011 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3931864
2 November 2010 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3893645
27 January 2009 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3391445
15 January 2009 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3392919
25 April 2008 Type not recorded
No type recorded · USCGC CUTTYHUNK (WPB 1322) · USCG Northwest District (CGD-NW) · Activity 3192550
24 January 2008 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3135668
17 January 2008 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3135657
25 October 2007 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3083124
12 June 2007 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2959708
13 February 2007 Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2871735
5 January 2006 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2561738
14 February 2005 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2292281
6 January 2005 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2270244
22 January 2004 Annual Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1984804
13 March 2003 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1757080
15 January 2002 Hull Examination · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1481506
28 February 2001 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1061396
23 February 2000 COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1463559
23 February 1999 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1464150
8 April 1998 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 788751
10 February 1998 Re-Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1381124
20 February 1997 Hull Examination · Initial Certification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1364093

Deficiency record · 39

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 September 2025 Resolved
Each ring life buoy on a vessel must: be approved in accordance with 160.050 in subchapter Q of this chapter…Ring life buoy was worn out and deteriorating. 46CFR180.70b(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2025
Resolved 6 October 2025
Resolution: Crew replaced ring buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 September 2025 Resolved
…Each floating water light must be approved in accordance with 161.010 in subchapter Q of this chapter…Floating water light would not turn on. 46CFR180.70d(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2025
Resolved 6 October 2025
Resolution: Crew replaced water light.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 September 2025 Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. Life float was only fitted with one paddle. 46CFR180.175d
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2025
Resolved 6 October 2025
Resolution: Crew added a second life float paddle.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 September 2024 Resolved
A vessel of >26ft in length must be fitted with individual bilge lines and suctions for each watertight compartment. Center void bilge hose is cracked and requires replacement.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2024
Resolved 26 September 2024
Resolution: Vessel replaced center void bilge hose.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 September 2024 Resolved
On a vessel of <26ft in length a visual and audible alarm must be provided at the operating station to indicate a high-water level. Alarm for lazarette did not sound/light and bilge pump did not work in “auto” setting.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 September 2024
Resolved 26 September 2024
Resolution: Vessel proved proper operation of the alarms and pump.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 24 September 2024 Resolved
The construction and arrangement of a vessel must allow safe operation of the vessel giving consideration to provisions for a seaworthy hull. FWD void overhead framing is wet/rotten and requires replacement.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 24 October 2025
Resolved 27 October 2025
Resolution: Received photo of satisfactory repairs.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 24 September 2024 Resolved
The exhaust piping must be properly supported by noncombustible hangers or blocks. Engine room aft bulkhead is degraded and exhaust brackets for both MDE’s no longer affixed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 September 2024
Resolved 26 September 2024
Resolution: Vessel replaced exhaust straps.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 September 2024 Resolved
A vessel of >26ft in length must be fitted with individual bilge lines and suctions for each watertight compartment. Engineroom bilge pump and hose do not work without manual intervention.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2024
Resolved 26 September 2024
Resolution: Bilg epump and hose were replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 24 September 2019 Resolved
COD valid for one year, prior to expiration of that year, owner of vessel must apply for renewal of the endorsements. Vessel must apply for renewal of COD.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2019
Resolved 30 September 2019
Resolution: Vessel representative provided proof of application and fees submission to NDVC day of inspection, picture of valid COD provided on 30SEP.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 8 November 2017 Resolved
Radio safety cert. expired. Renew. - 47 CFR 80.59(a)(2)
Due 8 December 2017
Resolved 28 November 2017
Documentation › Certificates/Documents › Stability Letter
Issued 8 November 2017 Resolved
Original stability letter not on board to accompany addendum. Post stability letter with vessel documents. - 46 CFR 178.210, 220
Due 8 December 2017
Resolved 8 November 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 November 2017 Resolved
Cabels under Nav. Station supported by zip-ties. Replace with metal supports every 24 inches. - 46 CFR 183.340(b)(4)
Due 8 December 2017
Resolved 31 August 2018
Documentation › Markings/Placards › Warning Signs
Issued 2 December 2015 Resolved
Mount emergency instructions at the operating station. 46 CFR 185.510(a)
Action required: 705 - Other - as specified
Due 12 December 2015
Resolved 21 December 2015
Resolution: Received email showing emergency instructions laminated and posted at operating station
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (hydraulic)
Issued 2 November 2010 Resolved
Ensure reliable means of stopping/shutting down starboard engine from the principal station from which the vessel is steered. Prove proper shutdown instead of manual operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 November 2010
Resolution: Faulty solenoid replaced, additional maintenance done to entire system. Starboard engine shutdown now operates consistently and correctly.
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 2 November 2010 Resolved
Remove unconnected bottle of Halon 1301 and properly replace, install and service a bottle of FE-241.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 November 2010
Resolution: Bottle replaced, installed, and serviced. The automatic engine shutdown and system override were both tested in the presence of a Coast Guard Marine Inspector and found to be operational.
Navigation › Piloting/Steering › Marine Charts
Issued 2 November 2010 Resolved
Provide corrected charts for route intended.
Due 30 November 2010
Resolved 10 November 2010
Resolution: Charts updated.
Navigation › Piloting/Steering › US Coast Pilot
Issued 2 November 2010 Resolved
Provide proof/receipt of updated U.S. Coast Pilot and leave on vessel.
Due 30 November 2010
Resolved 10 November 2010
Resolution: 2010 U.S. Coast Pilot purchased and stored aboard vessel.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 17 January 2008 Resolved
Vessel did not have EAP information posted. Vessel rep had recieved EAP supervisor training, but did not provide employees with required EAP training.
Due 18 February 2008
Resolved 23 January 2008
Resolution: Marine Employer posted EAP info and provided basic EAP training to employees.
Engineering › Bilge Water Management System › Not Operational
Issued 25 October 2007 Resolved
Fwd bilge alarm inoperable.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 October 2007
Resolution: Renewed bilge alarm sensor. Provided notice to Sec Seattle prior to carrying passengers.
Construction/Loadline › Hull › Stiffener
Issued 25 October 2007 Resolved
Stress cracks at base of aft pair of stiffeners/vertical supports in void under pilot house aft of collision bulkhead.
Condition: Unknown
Due 24 November 2007
Resolved 17 January 2008
Resolution: Repaired cracks which turned out to be minimal damage to the fiberglass.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 25 October 2007 Resolved
Renew battery and label with date. Light was operational at time of test.
Due 24 November 2007
Resolved 28 November 2007
Resolution: Replaced bettery.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 25 October 2007 Resolved
Renew batery and label with date. Light was operational at time of inspection.
Due 24 November 2007
Resolved 28 November 2007
Resolution: Replaced battery.
Lifesaving › Lifebuoys › Serviceable
Issued 25 October 2007 Resolved
Renew lifering due to end of service life. Lifering was still functional at time of inspection, but in need of renewal.
Due 24 November 2007
Resolved 28 November 2007
Resolution: Replaced lifering.
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 25 October 2007 Resolved
Retroreflective tape coming loose and becoming unservicable due to exposure. Renewal required.
Condition: Improper/Lack of Maintenance
Due 24 November 2007
Resolved 10 January 2008
Resolution: Renewed retrorefelective tape.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 25 October 2007 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 24 November 2007
Resolved 17 January 2008
Resolution: Renewed FCC Operator''s license.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 25 October 2007 Resolved
Operator did not have license onboard. Provide fax of license to Sec Seattle.
Due 24 November 2007
Resolved 17 January 2008
Resolution: Renewed license after finding out it had been expired for 2 years, IO shop did investigation.
Construction/Loadline › Structures › Superstructure
Issued 25 October 2007 Resolved
Port side bridge window was broken. Owner had ordered new window at time of inspection, but had not arrived. Window opening was covered to provide adequate protection from elements. Provide proof of installation of new window to Sec Seattle.
Condition: Damaged By Earlier Event
Due 24 November 2007
Resolved 17 January 2008
Resolution: Replaced port side window.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 13 February 2007 Resolved
Crop out the vertical deck support frame and lay-up new for port side 2nd frame in #3 void. Make permanent repairs to fractures in bulk head supporting bottom shell. Submit repair proposal to this office.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 February 2007
Resolved 13 February 2007
Resolution: See activity # 2871735
Stability › Watertight Integrity › General
Issued 5 January 2006 Resolved
Replace watertight hatch gaskets for lazerette and forward peak.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 February 2006
Resolved 15 February 2007
Stability › Weathertight Integrity › General
Issued 5 January 2006 Resolved
Remove unused hawse pipe in forward peak and make space watertight.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 February 2006
Resolved 15 February 2007
Lifesaving › Visual Distress Signals (General) › Marking
Issued 5 January 2006 Resolved
Label distress signals container.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 February 2006
Resolved 15 February 2006
Personnel › Training › First Aid/CPR
Issued 6 January 2005 Resolved
Vessel Crew could not produce evidence of a valid First Aid card.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 February 2005
Resolved 15 February 2005
Lifesaving › Hand Flares › Expired
Issued 6 January 2005 Resolved
Replace 3 expired orange day smoke distress signals.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 February 2005
Resolved 15 February 2005
Communications › Audible Communications › Horn/Whistle
Issued 6 January 2005 Resolved
Repair or replace horn.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 February 2005
Resolved 15 February 2005
Communications › Audible Communications › Bell
Issued 6 January 2005 Resolved
Provide bell of proper size for vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 January 2005
Resolved 15 February 2005
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 6 January 2005 Resolved
Provide portable bilge pump.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 February 2005
Resolved 15 February 2005
Documentation
Issued 10 February 1998 Resolved
PROVIDE DETROIT DIESEL SERVICING REPORT DETAILING BACK PRESSURE READINGS.
Condition: Unknown
Due 10 February 1998
Resolved 10 February 1998
Lifesaving
Issued 10 February 1998 Resolved
PROVIDE WATERLIGHT, WITH 100FT OF LINE, ATTACHED WITH A WEAK-LINK RATED FORBA.
Condition: Unknown
Due 10 February 1998
Resolved 10 February 1998
Engineering
Issued 10 February 1998 Resolved
PROVIDE DRAWING DETAILING LAYUP SCHEDULE OF EXHAUST PIPING.
Condition: Unknown
Due 10 February 1998
Resolved 10 February 1998

Casualty record · 1

9 February 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6636893
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.