MAURY USCG vessel records
← All vessels

KOYUK

Built
1966
Last inspected
27 August 2025
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 27 August 2025
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 23 calendar years (1985–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK9372
Flag
UNITED STATES
Tonnage
86 - Regulatory (Subpart C or D), Gross Ton 74 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-45218
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. Only barges and towing vessels are in this archive, so any other vessel type in the same activity does not appear here: these lists are a floor, not a complete manifest.

HARLEY SHIELD Freight Barge · MISLE 46194 · 25 July 2024 · activity 7967813

Inspection history · 34

27 August 2025 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8152230
25 July 2024 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7967813
25 July 2024 Administrative Inspection · Damage Survey
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8002675
16 July 2024 Drydock Exam · Administrative Inspection · Internal Structural Exam · COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7958885
29 June 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7724806
23 June 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7484586
6 July 2021 Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7263895
10 June 2021 Deficiency Check · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7221885
13 October 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7076625
24 June 2020 Deficiency Check · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6986884
23 October 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6840666
22 October 2018 COI Inspection · Deficiency Check · Hull Examination · Examination of Repairs · Initial Certification · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6566188
25 May 2018 Liferaft Servicing
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6457231
31 January 2017 Liferaft Servicing
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6081115
6 May 2015 Liferaft Servicing
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5120746
12 February 2015 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5068509
8 June 2012 Industry Initiated Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4336933
20 July 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1087505
16 June 1995 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1189753
26 July 1994 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 77110
12 May 1994 COI Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 859255
24 January 1994 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 851638
19 August 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 138320
21 June 1993 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1370643
22 June 1992 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1263629
2 July 1991 COI Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 937817
6 June 1990 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 931889
4 June 1990 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1238144
9 June 1989 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1035422
21 November 1988 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 892827
21 March 1988 Re-Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 974241
9 April 1987 COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1005657
4 April 1986 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 997255
3 April 1985 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1291680

Deficiency record · 43

05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 28 August 2025 Resolved
Replace expired EPIRP hydrostatic release
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2025
Resolved 27 September 2025
Resolution: all sat
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 August 2025 Resolved
Prove proper operation of lower aft mast light
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2025
Resolved 27 September 2025
Resolution: all sat
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 28 August 2025 Resolved
Prove audibly alarm for Center main low lube shut down on bridge
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2025
Resolved 27 September 2025
Resolution: all sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 August 2025 Resolved
Fix exhaust leak on center and Starboard main exhaust piping.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2025
Resolved 27 September 2025
Resolution: all sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 17 July 2024 Resolved
Install RPM gauge on Generator engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 August 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 July 2024 Resolved
Replace all expired life ring buoy light batteries.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 August 2024
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 17 July 2024 Resolved
Update EPRIB registration with correct Vessel call sign
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 August 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 17 July 2024 Resolved
Get FCC Radio telephony Cert and FCC Bridge to Bridge Cert. as per 47 CFR 80.851 47 CFR 80.1001
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 August 2024
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 17 July 2024 Resolved
Install lagging on generator and port main engine exhaust to prevent crew from touching hot exhaust pipe.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 August 2024
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 July 2024 Resolved
Prove proper operation on emergency light in galley
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 August 2024
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 July 2024 Resolved
Replace all expired items in first aid kit
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 August 2024
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 17 July 2024 Resolved
An visual and audible alarm is required at the operating station. Vessel needs to provide the following items: low fuel level, audible port and starboard, visual starboard low fuel level. Low hydraulic steering fluid level, audible, and visual.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 September 2024
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 17 July 2024 Resolved
Prove proper operation for the following alarms, main engine, low lube pressure, main engine high watercooling temp generator low lube oil pressure and generator high coolant temp. To the CG Marine inspector attending.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 August 2024
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 June 2020 Resolved
Installed Fire Detection System has not been installed or certified by a NICET IV Fire Alarm Engineering Technician, registered professional engineer with experience in fire-detection design, or authorized classification society with equivalent experience. Rectify deficiencies within 90 days.
Action required: 60 - Rectify deficiencies prior to movement
Due 22 September 2020
Resolved 10 June 2021
Resolution: Received NICET IV statement certifying the installed fixed detection system on board.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 October 2019 Resolved
Fire Detection System does not meet 46 CFR 142.330. Vessel must provide proof that either: 1) The existing system has been certified by a NICET IV Fire Alarm Engineering Technician or a Professional Engineer; or 2) A new approved system has been installed and certified by a NICET IV Fire Alarm Engineering Technician or a Professional Engineer.
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Due 23 October 2019
Resolved 24 June 2020
Resolution: Vessel replaced original fire detection system with a brand new system. However, new system was not installed by NICET IV or Professional Engineer. Reissued with extended timeframe.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 July 2019 Resolved
Provide proof of enrollment in approved drug testing program for each crew member within 7 days.
Action required: 705 - Other - as specified
Due 24 July 2019
Resolved 29 July 2019
Resolution: Received copies of enrollment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 July 2019 Resolved
Center MDE had an exhaust leak. Repair within 7 days.
Action required: 705 - Other - as specified
Due 24 July 2019
Resolved 7 August 2019
Resolution: Received email from master stating item was corrected.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 17 July 2019 Resolved
Provide E-lighting in accomodation spaces within 7 days.
Action required: 705 - Other - as specified
Due 24 July 2019
Resolved 7 August 2019
Resolution: Received email from master stating item was corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 17 July 2019 Resolved
Renew missing lagging on all engine exhausts in engine room within 7 days.
Action required: 705 - Other - as specified
Due 24 July 2019
Resolved 19 September 2019
Resolution: Received email from master stating that lagging was renewed.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 17 July 2019 Resolved
Ensure general alarm in forward accomodation space is operational within 7 days.
Action required: 705 - Other - as specified
Due 24 July 2019
Resolved 7 August 2019
Resolution: Received email from master stating that item was corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 17 July 2019 Resolved
Ensure there are additional life jackets and immersion suits onboard for normally manned watch stations. Provide one additional PFD and immersion suit on the bridge within 7 days.
Action required: 705 - Other - as specified
Due 24 July 2019
Resolved 7 August 2019
Resolution: Received email from master stating item was corrected.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 July 2019 Resolved
Provide proof that fire detection system meets 46CFR142.330 or install approved system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2019
Resolved 23 October 2019
Resolution: Deficiency cleared and reissued under Activity #6840666 to change action code.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 July 2019 Resolved
Ensure stern light and anchor light is operational. Provide day shape.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2019
Resolved 19 September 2019
Resolution: Received email from master stating lights are operational.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 July 2019 Resolved
Repair electrical wire on aft deck light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2019
Resolved 22 July 2019
Resolution: Received photo of repaired wire.
Construction/Loadline
Issued 12 May 1994 Resolved
REPAIR OR REPLACE THE VALVE ON THE SEACHEST VENT. THIS ITEM IS TO BE COMPLETED PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 3 August 1994
Resolved 3 August 1994
Construction/Loadline
Issued 12 May 1994 Resolved
PROVIDE CHECK VALVES ON ALL BILGE LINES AND REPLACE THE BROKEN CHECK VALVE IN NO. 4 STBD VOID. THIS ITEM IS TO BE COMPLETED PRIOR TO PLACING THE VESSEL INTO SERVICE.
Condition: Unknown
Due 6 June 1994
Resolved 19 July 1994
Engineering
Issued 12 May 1994 Resolved
REMOVE AND REPLACE ALL CUTLASS BEARINGS REBUILDING OR REPLACING SHAFTS AS NECESSARY.
Condition: Unknown
Due 13 May 1994
Resolved 13 May 1994
Fire Fighting
Issued 12 May 1994 Resolved
HYDROSTATICALLY TEST AND SERVICE ON BOARD FIRE EXTINGUISHERS AS NECESSARY TO MAKE CURRENT. THIS ITEM IS TO BE COMPLETED PRIOR TO PLACING THE VESSEL INTO SERVICE.
Condition: Unknown
Due 12 June 1994
Resolved 19 July 1994
Construction/Loadline
Issued 12 May 1994 Resolved
GROOVE AND REWELD FRACTURED WELD IN NO. 2 PORT VOID.
Condition: Unknown
Due 13 May 1994
Resolved 13 May 1994
Fire Fighting
Issued 12 May 1994 Resolved
RIG, TEST AND READY VESSEL FIRE STATIONS AND FIRE HOSES.
Condition: Unknown
Due 12 June 1994
Resolved 19 July 1994
Construction/Loadline
Issued 12 May 1994 Resolved
PRESENT THE VESSEL FOR HULL REPIAIR TO SET IN PORTIONS OF THE SIDE PLATING,CROPPING AND RENEWING AS REQUIRED BY ATTENDING INSPECTOR SIDE PLATE AND ASSOCIATED VERTICAL STIFFINERS AND OTHER ASSOCIATED STRENGTH MEMBERS OR OTHER HULL PLATING.
Condition: Unknown
Due 1 June 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 12 May 1994 Resolved
OPEN AND PRESENT FOR INTERNAL EXAMINATION THE STBD FUEL OIL TANK.
Condition: Unknown
Due 1 June 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 12 May 1994 Resolved
RIG AND READY ALL LIFE SAVING EQUIPMENT. THIS ITEM IS TO BE COMPLETED PRIOR TO PLACING THE VESSEL INTO SERVICE.
Condition: Unknown
Due 12 June 1994
Resolved 19 July 1994
Construction/Loadline
Issued 12 May 1994 Resolved
PROVE OPERATION OF ALL VESSEL SYSTEMS. THIS ITEM IS TO BE COMPLETED PRIOR TO PLACING THE VESSEL INTO SERVICE.
Condition: Unknown
Due 12 June 1994
Resolved 19 July 1994
Electrical
Issued 12 May 1994 Resolved
REMOVE DEADENDED WIRES AND PLACE ELECTRICAL SPLICES IN JUNCTION BOXS. THISITEM IS TO BE COMPLETED PRIOR TO PLACING THE VESSEL INTO SERVICE.
Condition: Unknown
Due 12 June 1994
Resolved 19 July 1994
Construction/Loadline
Issued 12 May 1994 Resolved
MARK ESCAPE HATCHS FROM ENGINE ROOM AND BERTHING "ESCAPE HATCH DO NOT BLOCK", AT OR NEAR UPPER SIDE OF EACH HATCH. THIS ITEM IS TO BE COMPLETED PRIOR TO PLACING THE VESSEL INTO SERVICE.
Condition: Unknown
Due 3 August 1994
Resolved 3 August 1994
Lifesaving
Issued 21 June 1993 Resolved
PROPERLY REMOVE AND DISPOSE OF EXCEES OIL IN BILGES.
Condition: Unknown
Due 25 June 1993
Resolved 28 July 1993
Lifesaving
Issued 21 June 1993 Resolved
PROVIDE VESSEL NAME ON ALL SURVIVAL SUITS.
Condition: Unknown
Due 25 June 1993
Resolved 28 July 1993
Fire Fighting
Issued 4 June 1990 Resolved
PROVIDE SPANNER WRENCH AT FIRE STATION NO.1.
Condition: Unknown
Due 4 June 1990
Resolved 4 June 1990
Lifesaving
Issued 4 June 1990 Resolved
PROPERLY LABEL LIFE JACKET STOWAGE.
Condition: Unknown
Due 4 June 1990
Resolved 4 June 1990
Navigation
Issued 4 June 1990 Resolved
PROVIDE COPY OF 46 CFR PARTS 90 TO 139 (SUBCHAPTER I).
Condition: Unknown
Due 4 June 1990
Resolved 4 June 1990
Navigation
Issued 4 June 1990 Resolved
PROVE PROPER OPERATION OF SHIP'S WHISTLE.
Condition: Unknown
Due 4 June 1990
Resolved 4 June 1990
Electrical
Issued 4 June 1990 Resolved
PROVIDE CLOSED-END MARINE TYPE BATTERY CABLE ENDS FOR PORT AND CENTER ENGINE BATTERIES.
Condition: Unknown
Due 4 June 1990
Resolved 4 June 1990

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.

Maury does not score, rate, or grade vessels. What Maury does not do · Glossary · Correct a record.