Records from 1985 to 2019. Most recent: inspection, 15 April 2019.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 35
15 April 2019
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6662443
20 July 2016
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5947467
19 July 2012
In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4387853
1 December 2011
Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4204114
15 February 2011
Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3960649
30 November 2010
Hull Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3902816
23 February 2009
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3423805
27 November 2007
COI Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3104589
2 November 2004
Re-Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2234514
10 February 2004
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2125959
29 October 2003
Re-Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1995190
10 December 2002
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1718846
5 December 2001
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1389525
28 February 2001
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1379334
15 December 1999
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1421771
15 January 1999
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 809571
15 December 1998
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1445410
15 December 1997
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1115187
11 December 1996
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1100105
27 February 1996
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 885731
8 December 1995
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 880295
13 January 1995
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1333404
13 December 1993
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1159517
9 March 1993
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 836158
29 January 1992
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1315117
19 February 1991
Hull Examination · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1224171
9 May 1990
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1232683
15 March 1990
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 924289
14 March 1990
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1225707
12 December 1989
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1228112
23 May 1989
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1341018
11 May 1988
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1041837
28 May 1987
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1334878
18 November 1986
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1329292
2 October 1985
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 988702
Electrical › Electrical Distribution System (service) › Bus Bar Connection
Issued 19 July 2012
Resolved
Clean all battery.
Due 19 August 2012
Resolved 16 August 2012
Lifesaving › Lifebuoys › Serviceable
Issued 19 July 2012
Resolved
Clean life ring.
Due 16 August 2012
Resolved 16 August 2012
Electrical › Electrical Distribution System (service) › Bus Bar Connection
Issued 1 December 2011
Resolved
Replace battery
Due 7 December 2011
Resolved 6 December 2011
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 December 2011
Resolved
Replace first aid kit
Due 7 December 2011
Resolved 6 December 2011
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 27 November 2007
Resolved
Forward deck rail/embarkation area is to be properly closed off to meet rail height requirments NLT 27DEC07.
Action required: 705 - Other - as specified
Due 27 December 2007
Resolved 25 February 2009
Resolution: Corrected
Fire Fighting › Fire Bucket › Capacity
Issued 27 November 2007
Resolved
Cracked fire bucket is to be replaced.
Action required: 705 - Other - as specified
Due 27 December 2007
Resolved 25 February 2009
Resolution: corrected
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 November 2007
Resolved
Inoperable stern light is to be fixed prior to operating at night but NLT 27DEC07.
Action required: 705 - Other - as specified
Due 27 December 2007
Resolved 25 February 2009
Resolution: Corrected
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 27 November 2007
Resolved
Retrorelective tape is to be provided on ring buoy prior to operating at night but NLT 27DEC07.
Action required: 705 - Other - as specified
Due 27 December 2007
Resolved 25 February 2009
Resolution: Corrected
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 November 2007
Resolved
Lanyard for the ring buoy is to be provided prior to operating at night, but NLT 27DEC07.
Action required: 705 - Other - as specified
Due 27 December 2007
Resolved 25 February 2009
Resolution: corrected
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 2 November 2004
Resolved
PROVIDE CERTIFICATE OF DOCUMENTATION
Due 9 November 2004
Resolved 9 November 2004
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 November 2004
Resolved
POST UPDATED COI REFLECTING DECK HAND AMENDMENT
Due 9 November 2004
Resolved 9 November 2004
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 2 November 2004
Resolved
RE MARK LIFE JACKETS WITH VESSELS NAME
Due 9 November 2004
Resolved 9 November 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 November 2004
Resolved
PROVIDE COAST GUARD APPROVED OR EQUIVALENT FIRST AID KIT
Due 9 November 2004
Resolved 9 November 2004
Electrical › Electric Supply System (service)
Issued 10 December 2002
Resolved
Permanently install fuse located on starboard side under after seating, in a watertight electrical box.
LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 January 2003
Resolved 28 January 2003
Lifesaving › Lifejacket/PFD (General)
Issued 10 December 2002
Resolved
Properly label location of all child life jackets & post proper donning procedures both forward and aft. LEGACY COMPONENT DESC: Marking
Condition: Improper Installation
Due 30 January 2003
Resolved 28 January 2003
Electrical › Electric Supply System (service)
Issued 10 December 2002
Resolved
Install a watertight cap for electrical charging system. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Due 30 January 2003
Resolved 28 January 2003
Electrical › Electrical Distribution System (service)
Issued 10 December 2002
Resolved
Remove plug for wet vac and submit plans for any new electrical instalation. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 30 January 2003
Resolved 28 January 2003
Electrical › Electrical Distribution System (service)
Issued 10 December 2002
Resolved
Properly terminate all loose wiring located in the operators area. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 30 January 2003
Resolved 28 January 2003
Fire Fighting › Fire Hoses
Issued 10 December 2002
Resolved
Extend bilge pump host to 4' length that doubles as fired hose. Add 3 buckets with 10 feet of line to be used as additional fire fighting while vessel is in service. LEGACY COMPONENT DESC: Length
Condition: Improper Installation
Due 30 January 2003
Resolved 28 January 2003
Navigation
Issued 10 December 2002
Resolved
Place 2 electrical lights on vessel.
Due 30 January 2003
Resolved 28 January 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 10 December 2002
Resolved
Permanently mount operators seat.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 January 2003
Resolved 28 January 2003
Documentation › Certificates/Documents
Issued 10 December 2002
Resolved
Place stability letter onboard vessel . LEGACY COMPONENT DESC: Stability Letter
Due 30 January 2003
Resolved 28 January 2003
Construction/Loadline › Structures
Issued 10 December 2002
Resolved
Replace damaged canopy on port bow and stbd midship. LEGACY COMPONENT DESC: Superstructure
Condition: Improper/Lack of Maintenance
Due 30 January 2003
Resolved 28 January 2003
Personnel › Certificates/Documents/Licenses
Issued 10 December 2002
Resolved
Operators of all vessels are to have the original license and copy of current first aid and cpr cards onboard while vessel is carrying passengers for hire.
Due 30 January 2003
Resolved 28 January 2003
Construction/Loadline
Issued 28 February 2001
Resolved
FOUND BOTH PORT AND STBD STRUT BENT OVER.
Condition: Unknown
Due 14 March 2001
Resolved 14 March 2001
Accommodation/Occupational Safety
Issued 28 February 2001
Resolved
FOUND STBD HANDRAIL FRACTURED.
Condition: Unknown
Due 14 March 2001
Resolved 14 March 2001
Documentation
Issued 15 December 1998
Resolved
PROVIDE JACMS WITH A CORRECTED COPY OF THE DOCUMENTION
Condition: Unknown
Due 18 December 1998
Resolved 18 December 1998
Engineering
Issued 15 December 1998
Resolved
PROVIDE JACMS WITH PROOF OF RENEWAL OF MOTOR MOUNT.
Condition: Unknown
Due 15 December 1998
Resolved 15 December 1998
Lifesaving
Issued 11 December 1996
Resolved
REMARK ALL PFD'S W/ VESSEL NAME.
Condition: Unknown
Due 18 December 1996
Resolved 26 December 1996
Lifesaving
Issued 11 December 1996
Resolved
REMARK BOX/CONTAINER STOWING CHILD-SIZED PFDS.
Condition: Unknown
Due 18 December 1996
Resolved 26 December 1996
Documentation
Issued 11 December 1996
Resolved
PROVIDE PROPER CERTIFICATE OF DOCUMENTATION TO REFLECT CURRENT VESSEL OWNER.
Condition: Unknown
Due 11 December 1996
Resolved 11 December 1996
Construction/Loadline
Issued 15 March 1990
Resolved
UTILIZE CORROSION RESISTANT FASTENERS TO SECURE NEW PLATE IN BATTERY COMPARTMENTS, FOAM-IN THE BATTERY BOXES AND SEAL TOP OF FOAM TO PREVENT FOAM ABSORBING FUTURE SPILLAGE.
Condition: Unknown
Due 15 March 1990
Resolved 15 March 1990
Construction/Loadline
Issued 15 March 1990
Resolved
REMOVE BATTERIES AND TREAT EXPOSED SURFACES OF THE BATTERY COMPARTMENTS WITH A BAKING SODA-WATER SLURRY SOLUTION TO NEUTRALIZE BATTERY ACID DAMAGE.
Condition: Unknown
Due 15 March 1990
Resolved 15 March 1990
Construction/Loadline
Issued 15 March 1990
Resolved
CROP OUT WASTED PLATE IN BOTTOM OF BATTERY COMPARTMENT AND ANY WASTED FRAMING. FRAMING IS TO BE RENEWED IN KIND.
Condition: Unknown
Due 15 March 1990
Resolved 15 March 1990
Construction/Loadline
Issued 12 December 1989
Resolved
REMOVE BATTERIES ADJACENT TO HOLES THROUGH DECK PLATE TO ALLOW FURTHER IN- SPECTION OF WASTED AREA.
Condition: Unknown
Due 12 December 1989
Resolved 12 December 1989
Electrical
Issued 12 December 1989
Resolved
CLEAN BATTERY TRAYS.
Condition: Unknown
Due 12 December 1989
Resolved 12 December 1989
Electrical
Issued 12 December 1989
Resolved
STRAP BATTERY CABLES.
Condition: Unknown
Due 12 December 1989
Resolved 12 December 1989
Lifesaving
Issued 18 November 1986
Resolved
ATTACH 31 SQUARE INCHES OF REFLECTIVE TAPE TO THE FRONT AND TO BACK OF ALL PFD'S.
Condition: Unknown
Due 18 November 1986
Resolved 18 November 1986