Documentation record
Registered dimensions (L × B × D)58.2 ft × 20.0 ft × 5.6 ft
Registered tonnagegross 50 / net 34
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHUGHES STEEL BOATS · FOUNTAIN VALLEY, CA, UNITED STATES · built 1966
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portDANA POINT, CA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 18 August 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it50 - Regulatory (Subpart C or D), Gross Ton
34 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 16 inspections, each with its date, unit and type; 12 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 16
22 April 2026
Vessel Attendance · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8291638
12 March 2025
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8063069
16 January 2025
Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8026724
28 February 2024
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7841478
23 February 2023
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7618824
11 January 2023
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7617145
14 February 2022
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7394994
24 March 2021
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7162058
13 January 2021
Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7124218
13 February 2020
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6884302
13 February 2019
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6607358
28 February 2018
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6332810
9 January 2018
Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6599045
21 February 2017
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6071883
11 January 2017
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6034223
24 February 2016
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5793243
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 March 2025
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removal flame screens or arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 X 30 mesh. Port and Starboard fuel vents were found to be missing flame screens.
46 CFR 182.450 (e)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2025
Resolved 18 March 2025
Resolution: Owner/operator provided proof of newly installed flame screens.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 March 2025
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A space with a through-hull fitting below the deepest load waterline. The high-level bilge alarm in the forepeak was found to be inoperable.
46 CFR 182.530 (a)(1)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2025
Resolved 18 March 2025
Resolution: Owner/operator provided proof of fixed high-level bilge alarm in the forepeak.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 12 March 2025
Resolved
Each survival craft required on a vessel by this part must meet one of the following: For a life float—Approved under approval series 160.027. It was observed that 03 life floats were equipped with non-compliant reflective tape on multiple sides of the floats.
46 CFR 180.200(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2025
Resolved 18 March 2025
Resolution: Owner/operator provided proof confirming the purchase and application of SOLAS reflective tape on the lifefloats.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 14 February 2022
Resolved
Replace the cracked window in the wheelhouse.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 February 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 February 2022
Resolved
Provide blanks for distribution panel in engine room.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 February 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 February 2022
Resolved
Provide metal support for wiring in engine room as identified to crew.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 14 February 2022
Resolution: Crew affixed wires to bulkhead using a metal support.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 February 2022
Resolved
Provide guards for rotating machinery in the engine room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 February 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 February 2019
Resolved
PROVIDE PROPER OPERATION OF PORT FUEL SHUT OFF VALVE. IAW CITE, ALL ENGINES MUST HAVE AT LEAST TWO MEANS OF STOPPING THE ENGINES. PORT FUEL SHUT OFF IS NOT SHUTTING COMPLETELY TO THE SATISFACTION OF THE MI.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 13 February 2019
Resolution: MASTER PROVIDED PROPER OPERATION OF PORT FUEL SHUT OFF VALVE BY ADJUSTING ANGLE OF THE WIRE.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 9 January 2018
Resolved
Over head frames 2-4 and overhead stringer have multiple broken stitch welds.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 January 2019
Resolved 31 January 2019
Resolution: removed cracked welds and weled in new stitch welds
Documentation › Markings/Placards › Warning Signs
Issued 21 February 2017
Resolved
Mount placards identifying fuel shutoff levers. Placards must be clearly mounted and visible for viewing by deckhands.
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 27 February 2017
Resolution: Placards appropriately placed.
Engineering › Sea-water System (primary cooling) › Valve
Issued 11 January 2017
Resolved
Replace stbd MDE raw water intake sea valve.
Action required: 705 - Other - as specified
Due 11 February 2017
Resolved 2 February 2017
Engineering › Sea-water System (primary cooling) › Valve
Issued 11 January 2017
Resolved
Replace the stbd generator raw water intake sea valve.
Action required: 705 - Other - as specified
Due 11 February 2017
Resolved 2 February 2017