Records from 2004 to 2025. Most recent: inspection, 5 February 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 32
5 February 2025
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8075193
30 November 2024
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8035263
25 April 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7875633
18 March 2024
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7881122
26 January 2024
In-Service Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7853360
17 January 2024
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7850693
8 December 2023
Administrative Inspection · Special Consideration · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7836727
28 July 2023
In-Service Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7754149
10 April 2023
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7660595
30 January 2023
Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7618852
21 December 2022
Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7613915
4 November 2022
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7576939
19 April 2022
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7433425
28 January 2022
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7387481
25 January 2022
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7384930
30 October 2021
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7343620
15 October 2021
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7333605
13 May 2021
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7196905
20 April 2021
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7178958
4 May 2020
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6948230
3 February 2020
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6901770
22 January 2020
Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6895150
20 September 2019
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6816940
8 April 2019
DAPI Audit · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6630775
7 December 2018
In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6622694
6 February 2018
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6348565
30 January 2018
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6345841
13 August 2017
Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6239653
13 August 2017
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6240785
11 April 2017
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6108162
2 March 2016
Annual Inspection · Examination of Repairs · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5859449
5 January 2016
Permit to Proceed · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5791316
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 February 2025
Resolved
Repairs or alernations to the hull, machinery or quipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI...Repairs or alterations that affect the safety of the vessel include, but are not limited to: fuel lines, tanks...vessel fuel tank found to be leaking.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 March 2025
Resolution: Verified fuel tank installation
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 April 2024
Resolved
The two required fixed power bilge pumps shall be self-priming and shall each be driven by different sources of power. If one pump is driven off the main engine in a single propulsion engine installation, the other shall be independently driven. Marine Inspector observed the vessel does not have two power driven bilge pumps. Submit plans to OCMI for approval of a second power bilge pump.
46 CFR 182.25-10
(Old T)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2024
Resolved 25 June 2024
Resolution: PTO Bilge pump installed on port engine. Witnessed satisfactory operation.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 April 2024
Resolved
Complete but simple instructions for the operation of a fixed gas fire extinguishing system must be located in
a conspicuous place at or near each pull box and stop valve control and in the space where the extinguishing
agent cylinders are stored. Marine Inspector observed no instructions posted by the CO2 system remote pull station. Post instructions at the location of the pull station.
46 CFR 185.612 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2024
Resolved 25 June 2024
Resolution: Sign posted.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 April 2024
Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked as follows: "CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. DISCHARGE INTO NEARBY SPACE CAN COLLECT HERE. WHEN ALARM OPERATES VACATE IMMEDIATELY." Marine Inspector observed no posted warning sign at the entrance to steering gear compartment. Post appropriate warning signs at the designated entrance.
46 CFR 185.612 (g)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2024
Resolved 25 June 2024
Resolution: Sign posted.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 April 2024
Resolved
Each entrance to a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked as follows: "CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. WHEN ALARM OPERATES DO NOT ENTER UNTIL VENTILATED. LOCK OUT SYSTEM WHEN SERVICING." Marine Inspector observed no posted warning sign at the entrance to the machinery space/engine room. Post appropriate warning signs at the designated entrance.
46 CFR 185.612 (g)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2024
Resolved 25 June 2024
Resolution: Sign Posted.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 January 2024
Resolved
Found excessive rotting wood in the chain locker on the upper bow stem. Excavate to good wood and submit repair plan to local OCMI for approval before beginning repairs. Repairs must be completed before carrying passengers and receiving credit dry-dock. Also, Sector LA/LB may require the vessel to haul out again if more damage is discovered.
Action required: 705 - Other - as specified
Due 29 February 2024
Resolved 17 March 2024
Resolution: Vsl made repairs to the satisfaction of the attending MI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 January 2024
Resolved
Found 2 spots in the engine room overhead longitudinal beam on the port and starboard side/forward. Excavate starboard to good wood and submit repair proposal to local [name withheld] excess epoxy on the port side for re-inspection.
Action required: 705 - Other - as specified
Due 29 February 2024
Resolved 14 March 2024
Resolution: Vsl has made repairs to the satisfaction of the attending MI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 January 2024
Resolved
Found bonding strap in the engine room under the starboard shaft in need of repair. Scrap and treat affected areas to the satisfaction of the marine inspector.
Action required: 705 - Other - as specified
Due 29 February 2024
Resolved 14 March 2024
Resolution: Vsl has made repairs to the satisfaction of the attending MI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 January 2024
Resolved
Found bonding strap in the bilge of the crew accommodations in need of repair. Scrap and treat affected areas to the satisfaction of the marine inspector.
Action required: 705 - Other - as specified
Due 29 February 2024
Resolved 14 March 2024
Resolution: Vsl has made repairs to the satisfaction of the attending MI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 January 2024
Resolved
Found 2 spots on the port and starboard transom that have rot. Scrap and treat affected areas to the satisfaction of the marine inspector.
Action required: 705 - Other - as specified
Due 29 February 2024
Resolved 14 March 2024
Resolution: Vsl has made repairs to the satisfaction of the attending MI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 January 2024
Resolved
Excavate solid timber attached to lower portion of stem in the chain locker including the upper 3 keel bolts. Cut out upper 22" or to good wood. Submit repair plan to local OCMI for approval before beginning repairs.
Action required: 705 - Other - as specified
Due 29 February 2024
Resolved 14 March 2024
Resolution: Vsl has made repairs to the satisfaction of the attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 3 August 2023
Resolved
Stowage of life floats or buoyant apparatus. Painter must be resistant to deterioration to UV light. Vessel has nine life floats with 127 persons capacity. Painter on port consist of floats worn and ready to break. Limit of 80 passengers (4x20 person) floats rigged in good service until the painter is replaced. 46 CFR 180.137, 46 CFR 180.175(f)(3).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 August 2023
Resolution: Operator emailed statement and photos of replaced and spliced painter line.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 30 January 2023
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Vessel has expired first aid kit
46 CFR 180.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2023
Resolved 31 January 2023
Resolution: Received picture evidence of new first aid kit and receipt.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 31 December 2022
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. ***Vessel is restricted to a limited coastwise route until a compliant fire detection system is installed.***
Action required: 705 - Other - as specified
Resolved 6 January 2023
Resolution: Vessel satisfactory installed interconnected fire detection system.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 19 April 2022
Resolved
Must submit plans for the installation and use of monitoring devices to ensure the wakefulnes of the watchman.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2022
Resolved 4 May 2022
Resolution: Operator provided email, phone con, and ship date information (plan was submitted and operator ordered device).
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 April 2021
Resolved
An adult life jacket must be provided for each person carried on board. Vessel has 110 life jackets on board out of the required 115. Vessel is restricted to 110 total persons when operating on a Limited Coastwise route.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 15 October 2021
Resolution: Contacted operator about outstanding def; operator has elected to have passenger count on COI reduced when vessel is operating on a Limited Coastwise route.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 April 2021
Resolved
Each life jacket carried on a vessel on Oceans route must have a life jacket light approved in accordance with 161.012 in Subchapter Q. Vessel has 38 life jackets without approved lights. Vessel is restricted to 38 total persons when operating on an Oceans route.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 May 2021
Resolution: Vessel provided approved life jacket lights for 65 life jackets.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 May 2020
Resolved
DUE TO COVID-19 CIRCUMSTANCES BEYOND THE CONTROL OF THE VESSEL, THE VESSEL IS UNABLE TO MEET THE TIMEFRAME AS REQUIRED BY 46CFR176.107. VESSEL IS ALLOWED 90 DAYS TO CONTINUE OPERATIONS ON DOMESTICS ROUTES ONLY, IN ACCORDANCE WITH THE COI, AND IS REQUIRED TO MAKE ITSELF AVAILABLE FOR INSPECTION PRIOR TO 03AUG20. IF VESSEL PLANS ON OPERATING ON AN INTERNATIONAL ROUTE, THE OCMI MUST BE NOTIFIED PRIOR TO OPERATION.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 August 2020
Resolved 7 July 2020
Resolution: Succefully completed annual inspection.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 6 February 2018
Resolved
REPAIR TWO CRACKED BRIDGE WINDOWS.
Condition: Damaged By Earlier Event
Due 20 March 2018
Resolved 22 February 2018
Resolution: Bridge windows were replaced.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 30 January 2018
Resolved
Repair dry rot on starboard side of lazarette watertight bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 February 2018
Resolved 31 January 2018
Resolution: Repairs complete and to the satisfaction of attending marine inspector.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear, Timing
Issued 13 August 2017
Resolved
PROVE PROPER OPERATION OF THE PORT ENGINE PRIOR TO CARRYING PASSENGERS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. 46CFR182.200(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 August 2017
Resolution: Conducted an operational test of the port main engine, underway sea trial conducted for 20 minutes at 1025rpm. All satisfactory.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 11 April 2017
Resolved
Provide & properly install life jacket lights on 39 adult & 05 children life jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 April 2017
Resolved 17 April 2017
Resolution: Vessel provided and properly installed life jacket lights on 39 Adults & 05 children life jackets.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 31 May 2016
Resolved
Provide 12 new adult lifejackets.
Condition: Invalid
Due 14 June 2016
Resolved 3 June 2016
Resolution: New lifejackets PFD-Type I provided.
Construction/Loadline › Hull › Hull Plating
Issued 19 February 2016
Resolved
Complete credit drydock IAW 46 CFR 176.600.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 February 2016
Resolved 25 May 2016
Resolution: Completed credit dry dock Gambols Shipyard Activity #5859449
Construction/Loadline › Structures › Transverse Bulkhead
Issued 19 February 2016
Resolved
Make proper repairs to stbd side of collision bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 February 2016
Resolved 29 February 2016
Resolution: FRP repairs to collision bulkhead completed.
Construction/Loadline › Hull › Hull Plating
Issued 19 February 2016
Resolved
Provide temp repairs for two plywood cut-outs on the port side hull in aft berthing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 February 2016
Resolved 29 February 2016
Resolution: Temp repairs completed.