Records from 1996 to 2015. Most recent: inspection, 20 October 2015.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 23
20 October 2015
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5746551
19 May 2014
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4863014
24 July 2012
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4389042
23 May 2012
COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4319969
13 January 2012
Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4225701
13 September 2011
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4143747
23 June 2008
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3246327
15 May 2008
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3188830
24 June 2007
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2971895
14 May 2007
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2927807
12 January 2007
Hull Examination
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2854902
20 April 2006
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2629035
5 May 2005
COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2347715
17 May 2004
Annual Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2050933
25 April 2003
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1764441
18 April 2002
Hull Examination · Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1493937
27 April 2001
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1405172
11 May 2000
COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1395429
26 April 1999
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1468919
20 May 1998
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1471344
5 May 1997
COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1396802
3 December 1996
Inclining Experiment
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1371770
7 October 1996
Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1371711
Documentation › Markings/Placards › Official Number (US)
Issued 23 May 2012
Resolved
Permanently affix the vessels official number to the hull as required by 46CFR67.121.
Action required: 705 - Other - as specified
Due 1 July 2012
Resolved 23 July 2012
Resolution: ON has been permanently affixed to vessel. Forward compartment area.
Fire Fighting › Remote Fuel Shutoff › General
Issued 23 May 2012
Resolved
Label fuel shut off valves with the direction of operation as required by 46CFR185.608.
Action required: 705 - Other - as specified
Due 1 July 2012
Resolved 23 July 2012
Resolution: Fuel shutoff vavles have been labeled IAW Regulation
Engineering › Bilge Water Management System › Not Operational
Issued 15 May 2008
Resolved
Prove proper operation of the bilge alarm prior to carrying passengers IAW 46 CFR 182.530.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2008
Resolved 29 May 2008
Resolution: Bilge alarm worked properly.
Engineering › Bilge Water Management System › Hose
Issued 15 May 2008
Resolved
Properly replace bilge discharge line w/one continous line IAW 46 CFR 182.510.
Action required: 705 - Other - as specified
Due 15 June 2008
Resolved 23 June 2008
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 15 May 2008
Resolved
Properly repair anti-freeze leak on the MDE IAW 176.25.10.
Action required: 705 - Other - as specified
Due 15 June 2008
Resolved 23 June 2008
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 15 May 2008
Resolved
Properly re-install or remove insulation above the exhaust system in the engine room.
Action required: 705 - Other - as specified
Due 15 June 2008
Resolved 23 June 2008
Construction/Loadline › Structures › Deck Plating
Issued 15 May 2008
Resolved
Properly replace deck inspection hatch covers prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2008
Resolved 23 May 2008
Resolution: New decking and hatch covers were installed.
Construction/Loadline › Structures › Deck Plating
Issued 15 May 2008
Resolved
Prior to carrying passengers, prove the condition of the deck is safe for passengers, if plans to crop & renew, it must be to the satisfaction of a U.S.C.G. Marine Inspector & IAW NVIC 8-87. Upon completion of dect condition assessment or repairing credit my be granted for annual exam.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2008
Resolved 23 May 2008
Resolution: New decking and hatch covers were installed.
Engineering › Electric Propulsion System › Battery
Issued 15 May 2008
Resolved
Properly protect battery from objects IAW 46 CFR 183.334.
Action required: 705 - Other - as specified
Due 15 June 2008
Resolved 23 June 2008
Construction/Loadline › Structures › Deck Plating
Issued 15 May 2008
Resolved
Properly replace FRP decking under batteries IAW NVIC 8-87. Submit plans to MSU and get approval prior to initiating work.
Action required: 705 - Other - as specified
Due 15 June 2008
Resolved 23 June 2008
Electrical › Electric Supply System (service) › Battery Installation
Issued 15 May 2008
Resolved
Properly secure battery IAW 46 CFR 111. 15-6 (Old T)
Action required: 705 - Other - as specified
Due 15 June 2008
Resolved 23 June 2008
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 15 May 2008
Resolved
Obtain 3 new lifejackets. Passenger count reduced to 46 until cleared.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2008
Resolved 23 June 2008
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 15 May 2008
Resolved
Properly re-apply reflective material to 4 lifejackets. Passenger count reduced by 4 until cleared.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2008
Resolved 23 June 2008
Navigation › Piloting/Steering › Magnetic Compass
Issued 14 May 2007
Resolved
Provide proof of compass light operation.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 June 2007
Resolved 18 May 2007
Resolution: The operation of the compass light was confimed.
Lifesaving › Lifebuoys › Serviceable
Issued 14 May 2007
Resolved
Replace lifebuoy on embarkation platform.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 June 2007
Resolved 18 May 2007
Resolution: A new ring buoy was put into service.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 14 May 2007
Resolved
Provide proof that fixed fire system was properly serviced.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 June 2007
Resolved 18 May 2007
Resolution: A receipt for service was provided by [name withheld] and given to [name withheld] showing proper completion of servicing.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 April 2006
Resolved
Provide first aid kit in accordance with 46 CFR 184.710
Action required: 705 - Other - as specified
Due 19 May 2006
Resolved 12 May 2006
Fire Fighting
Issued 27 April 2001
Resolved
PROVE PROPER OPERATION OF VESSEL'S AUDIBLE AND VISUAL FIXED FIREFIGHTING ALARMS BEFORE TAKING ON PASSENGERS, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR AND COGNIZANT OCMI.
Condition: Unknown
Due 11 May 2001
Resolved 7 May 2001
Engineering
Issued 11 May 2000
Resolved
Make operable or remove all old engine remote shutdown system mechanisms tothe satisfaction of the attending marine inspector.
Condition: Unknown
Due 31 May 2000
Resolved 31 May 2000
Fire Fighting
Issued 26 April 1999
Resolved
VESSEL IS PROHIBITED FROM OPERATING WITH PASSENGERS PENDING INSTALLATON OF AUTOMATIC ENGINE SHUTDOWN FOR FIXED FLOODING SYSTEM TP SATISFACTION OF ATTENDING MARINE INSPECTOR
Condition: Unknown
Due 7 May 1999
Resolved 11 May 1999
Documentation
Issued 26 April 1999
Resolved
VESSLE IS PROHIBITED FROM OPERATING WITH PASSENGERS PENDING PROOF OF CURRENT CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 17 May 1999
Resolved 11 May 1999
Navigation
Issued 20 May 1998
Resolved
Provide missing emergency broadcast radio placard by 03 June 98.
Condition: Unknown
Due 30 June 1998
Resolved 29 June 1998
Documentation
Issued 20 May 1998
Resolved
Provide missing stability letter for vessel by 03 June 98.
Condition: Unknown
Due 30 June 1998
Resolved 29 June 1998
Construction/Loadline
Issued 20 May 1998
Resolved
Make repairs at aft stbd inside corner to fiberglass patch by 20 June 98.
Condition: Unknown
Due 20 June 1998
Resolved 24 June 1998
Documentation
Issued 20 May 1998
Resolved
Certificate of Documentation was found to be missing current endorsement._x001C_ Provide current COI for vessel by 03 June 98.
Condition: Unknown
Due 3 June 1998
Resolved 24 June 1998
Navigation
Issued 20 May 1998
Resolved
Provide missing compass deviation table for vessel by 03 June 98.
Condition: Unknown
Due 30 June 1998
Resolved 29 June 1998
Lifesaving
Issued 5 May 1997
Resolved
Properly label lifejacket staowage lockers.
Condition: Unknown
Due 1 June 1997
Resolved 26 September 1997
Engineering
Issued 5 May 1997
Resolved
Replace non-metallic fuel hoses that exceed thirty (30) inches in length.
Condition: Unknown
Due 1 June 1997
Resolved 26 September 1997
Documentation
Issued 5 May 1997
Resolved
Provide current FCC Great Lakes Radiotelephone Agreement.
Condition: Unknown
Due 1 June 1997
Resolved 25 September 1997
Accommodation/Occupational Safety
Issued 5 May 1997
Resolved
Provide suitable emergency checklist and emergency broadcast placard.
Condition: Unknown
Due 1 June 1997
Resolved 25 September 1997
Engineering
Issued 5 May 1997
Resolved
Provide, and prove proper operation of an acceptable remote emergency fuel shut off valve.
Condition: Unknown
Due 1 June 1997
Resolved 26 September 1997
Engineering
Issued 5 May 1997
Resolved
double clamp engine hoses wher accessible and practicable.
Condition: Unknown
Due 1 June 1997
Resolved 26 September 1997
Electrical
Issued 5 May 1997
Resolved
Provide corrosion resistant (or lined) container for batteries.
Condition: Unknown
Due 1 June 1997
Resolved 26 September 1997
Electrical
Issued 5 May 1997
Resolved
Properly block and brace batteries.
Condition: Unknown
Due 1 June 1997
Resolved 26 September 1997
Electrical
Issued 5 May 1997
Resolved
Install blanks in open spoyts on fuse panel.
Condition: Unknown
Due 1 June 1997
Resolved 26 September 1997
Navigation
Issued 5 May 1997
Resolved
Provide a currently calculated magnetic compass deviation table.
Condition: Unknown
Due 1 June 1997
Resolved 25 September 1997