MAURY USCG vessel records Sign in
← All vessels

AQUASTAR

AQUASTAR is a 1966 passenger vessel (inspected). The Coast Guard has recorded 81 inspections since 1985, most recently in July 2026, along with 159 deficiencies and 1 casualty investigation in 2017.

Records from 1985 to 2026. Most recent: inspection, 7 July 2026.

Built
1966
Last inspected
7 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ9978
Flag
UNITED STATES
367183220, 368031250
Maury page id
psix-45275

Inspections, by type

…with no type recorded7
Years with a record 39 calendar years (1985–2026)
The 81 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)61.0 ft × 26.9 ft × 7.6 ft
Registered tonnagegross 79 / net 54
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLOUNT MARINE CORP · WARREN, RI, UNITED STATES · built 1966
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMUSKEGON, MI
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 4 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it79 - Regulatory (Subpart C or D), Gross Ton
54 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ9978MMSI 368031250 · active · compulsorily equipped · granted 5 April 2018, expires 5 April 2028
WTN5670MMSI 367183220 · active · compulsorily equipped · granted 4 April 2017, expires 2 May 2027 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 81

7 July 2026 Administrative Inspection
Administrative · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 8431356
11 May 2026 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 8354151
6 May 2025 Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 8126847
16 May 2024 Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7912788
24 May 2023 Deficiency Check · In-Service Inspection · Annual Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7695429
17 May 2022 Simplified Stability Test
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7619938
16 May 2022 COI Inspection · Deficiency Check
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7452232
20 October 2021 Administrative Inspection
Administrative · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7336190
17 September 2021 Drydock Exam · Construction Oversight · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7316159
14 May 2021 Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7197037
15 May 2020 Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 6953895
15 May 2019 Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6689693
6 February 2019 Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6621336
28 September 2018 Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6550808
14 May 2018 DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 6414108
31 July 2017 Damage Survey
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 6226357
18 July 2017 Deficiency Check
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 6346439
1 July 2017 Type not recorded
No type recorded · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 6236327
31 May 2017 Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 6161232
28 September 2016 Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6012068
22 June 2016 Drydock Extension · Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 5932065
9 September 2015 Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 5719749
25 August 2015 Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 5227019
18 June 2014 Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4914448
12 June 2012 Deficiency Check · Administrative Inspection · Simplified Stability Test
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4351210
18 May 2012 Deficiency Check
Physical examination · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 4314654
16 May 2012 COI Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4306045
12 October 2010 Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3869213
11 June 2008 Annual Inspection
Physical examination · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 3279155
31 May 2007 COI Inspection
Physical examination · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2947206
15 June 2006 Deficiency Check
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2680315
13 June 2006 Annual Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2678840
26 October 2005 Hull Examination
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2522283
2 September 2005 Deficiency Check
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2481761
18 August 2005 Administrative Inspection
Administrative · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2467151
22 July 2005 Deficiency Check
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2435581
21 July 2005 Annual Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2435496
10 August 2004 Deficiency Check
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2162135
8 July 2004 Annual Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2125809
24 June 2003 Re-Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 1847109
11 June 2002 COI Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 1730153
21 June 2001 Excursion Permit
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1067537
5 June 2001 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1415630
17 October 2000 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1057194
21 June 2000 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1460431
24 June 1999 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1386539
15 June 1998 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1402694
17 July 1997 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 781461
5 July 1997 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1396763
10 June 1997 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 773965
5 August 1996 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1090196
28 June 1996 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1088553
25 June 1996 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1470120
21 November 1995 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 878334
31 October 1995 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 879212
6 October 1995 Hull Examination
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1188192
1 August 1995 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 875321
12 July 1995 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 883029
20 June 1995 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1446213
26 September 1994 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 869531
30 August 1994 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1409175
21 October 1993 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 827557
18 June 1993 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1429772
16 June 1992 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1269267
7 November 1991 Plan Review "T" Boat
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 956321
12 June 1991 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1267391
30 April 1991 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 918499
13 December 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1215159
25 May 1990 Deficiency Check · COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 930815
20 December 1989 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 901181
18 October 1989 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1042683
18 August 1989 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1197020
15 June 1989 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1042459
22 May 1989 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 888821
11 July 1988 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 897982
18 May 1988 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1194033
30 June 1987 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1326489
22 May 1987 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1027862
20 May 1986 COI Inspection · Credit Drydock
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 994231
30 July 1985 Type not recorded
No type recorded · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 982120
10 May 1985 Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1290652

Deficiency record · 159

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 May 2026 Resolved
The power fire pump shall be of such size to discharge an effective stream. Fire pump not operational.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2026
Resolved 15 May 2026
Resolution: Fire pump Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 May 2026 Resolved
Vessel is required a bilge pump that may also serve as a fire pump. Fire pump not operational and can not pump bilges.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2026
Resolved 15 May 2026
Resolution: Bilge pump Sat
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 11 May 2026 Resolved
Vessel that operates in high seas is required an EPIRB. None on board vessel. Vessel restricted to no more than 3 miles from shore.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2026
Resolved 1 July 2026
Resolution: New EPIRB installed and sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 11 May 2026 Resolved
Vessel on a Great Lakes route requires 12 visual distress signals. Vessel has six. Vessel restricted to LBS/Rivers routes.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2026
Resolved 15 May 2026
Resolution: 12 flares onboard
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 11 May 2026 Resolved
Each window and port hole must be capable of withstanding maximum load from wind and wave and will not break into dangerous fragments if fractured. Vessel missing window STBD aft on main deck and has cracks in (2) port holes in pilot house.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2026
Resolved 9 June 2026
Resolution: Received photos showing windows and port holes repaired.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 11 May 2026 Resolved
All electrical equipment must be suitable for the voltage and current utilized. Remove daisy chained surge protectors from pilot house.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2026
Resolved 15 May 2026
Resolution: removed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 May 2026 Resolved
An adult lifejacket must be provided for each person onboard. Vessel has 150 PFDs. Vessel limited to 142 passengers.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2026
Resolved 15 May 2026
Resolution: All PFDs onboard
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 May 2026 Resolved
Ringbuoys must have retro-reflective tape with (1) with lifeline and (1) with waterlight. Waterlight not attached to RB. Lifeline doesn't exit bag.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2026
Resolved 15 May 2026
Resolution: RBs fixed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 May 2026 Resolved
All electrical equipment must be protected and can't be inadvertedly touched or subject to moisture or dirt. Switchboard is exposed to such hazards.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2026
Resolved 15 May 2026
Resolution: mat installed to cover switchboard
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 16 May 2024 Resolved
Each life float stowed in a group must be stowed with each group secured by a single painter and long enough that each life float can float without contacting any other life float in the group. Found Painter degraded and frayed. Provide proof of newly installed painter line.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2024
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 16 May 2024 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level. Alarm did not display visual indicator. Provide proper visual indicator for high water alarm.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 May 2024 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Provide proper life jacket donning instructions.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 16 May 2024 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. Hydrostatic release for EPIRB was expired.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2024
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 16 May 2024 Resolved
A vessel must comply with the applicable requirements for any radio installations, including the requirements for a station license. Provide valid radio station license.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 May 2023 Resolved
Found torn tags on 6 life jackets. Removed from service.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2023
Resolved 9 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 24 May 2023 Resolved
Installed float-free link was expired on port life float bank. There was no float-free link connected to the starboard life float bank.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2023
Resolved 9 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 May 2022 Resolved
An adult life jacket must be provided for each person on board a vessel and must be marked IAW 46 CFR 185.604. 24 adult life jackets were condemned and 15 adult life jackets were temporarily removed from service due to improper marking / lack of retro-reflective material. Passenger count is decreased to 116 and max persons on board may not exceed 119 until full compliment of life jackets is on board vessel, marked appropriately, and in good and serviceable condition.
Action required: 705 - Other - as specified
Resolved 14 July 2022
Resolution: Received invoice showing receipt of remaining life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 May 2022 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places visible to crew and passengers. Vessel has 02 types of life jackets on board. Only one type of life jacket has posted donning placards.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2022
Resolution: Vessel Rep. provided evidence of required placards posted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 May 2022 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired/replaced. Grab lines on life floats and ring life buoys were deteriorated. 46 CFR 176.808
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 June 2022
Resolution: Vessel Rep. provided evidence of renewed grab lines.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 19 May 2022 Resolved
As appropriate for intended voyage, a vessel must carry adequate and up-to-date: charts, US Coast Pilot, USCG Light List OR extracts from the publications for the areas to be transited. Vessel's e-charts not on board at time of inspection and publications out of date.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 June 2022
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 19 May 2022 Resolved
Each self-propelled vessel 12 meters or more in length shall carry on board a copy of Inland Navigation Rules. NAVRULES on board vessel out of date.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 June 2022
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 May 2019 Resolved
Bilge high water alarm in steering space not operational. Corrected prior to completion of inspection.
Due 15 May 2019
Resolved 15 May 2019
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 6 February 2019 Resolved
Crop and renew to good steel the deck plating in way of wasted sections of main deck to engineroom, port and stbd sides between fwd and aft bulkheads from sideshell/gunwhale inboard for 36-40 inches.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2019
Resolved 2 April 2019
Resolution: New steel inserted in way of wasted deck plating.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 14 May 2018 Resolved
Vessel has new owners and new COD has not been issued
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2018
Documentation › Markings/Placards › Garbage Placard
Issued 14 May 2018 Resolved
Vessel did not have Garbage Placard posted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2018
Resolved 29 May 2018
Documentation › Logs/Records › Drug Test Records
Issued 14 May 2018 Resolved
New owners did not have proof of employee enrollement in DAPI program
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2018
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 14 May 2018 Resolved
New owners did not have any training or drill logs
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 May 2018
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 14 May 2018 Resolved
Three PFDs were found unserviceable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2018
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 14 May 2018 Resolved
Childrens lifejacket storage was not marked.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2018
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 14 May 2018 Resolved
Vessel crew not ready to conduct man overboard drill.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 May 2018
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 14 May 2018 Resolved
Renew weak links for buoyant apparatus
Due 14 May 2019
Resolved 15 May 2019
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 May 2018 Resolved
Sections of non-conductive mats were missing from both the AC switchboard and DC switchboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2018
Resolved 29 May 2018
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 May 2018 Resolved
Section of exhaust lagging was missing on starboard main engine.
Due 14 May 2019
Resolved 15 May 2019
Electrical › Electric Supply System (service) › Battery Installation
Issued 14 May 2018 Resolved
Port battery installation was missing its cover.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2018
Resolved 29 May 2018
Engineering › Steering Gear System › Cable
Issued 31 July 2017 Resolved
Starboard cable parted
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2017
Resolved 1 August 2017
Resolution: O/O replaced steering cable
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 31 July 2017 Resolved
Crew not famailar with emergency steering system
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2017
Resolved 1 August 2017
Resolution: Master instructed crew and made placards for e operations.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 31 May 2017 Resolved
20 PFDs not servicable. Passenger count restricted until new PFDs are delivered.
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 18 July 2017
Resolution: Vessel purchased new PFDs
Lifesaving › Hand Flares › Not on Board
Issued 31 May 2017 Resolved
Vessel missing two of required six flares.
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 18 July 2017
Resolution: Vessel purchased new flares. DD GH
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 May 2017 Resolved
Wiring not securing and partially blocking ladder/escape route.
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 18 July 2017
Resolution: Wires secured
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 31 May 2017 Resolved
Two BAs missing waterlights
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 18 July 2017
Resolution: New batteries for lights installed
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 31 May 2017 Resolved
Bow light painted over.
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 18 July 2017
Resolution: Crew scrapped off paint
Operations/Management › Equipment Service/Testing › EPIRB
Issued 31 May 2017 Resolved
EPIRB hydro release not marked with expiration
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 30 July 2017
Resolution: hydro date correctly marked
Operations/Management › Equipment Service/Testing › EPIRB
Issued 31 May 2017 Resolved
EPIRB not registered or marked with NOAA registration
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 18 July 2017
Resolution: EPIRB properly registered
Documentation › Certificates/Documents › Certificate of Inspection
Issued 31 May 2017 Resolved
Vessel operated with passengers for hire with an expired COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 June 2017
Resolution: Satisfactory 5-year COI completed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 June 2016 Resolved
Improper solid core wire installed to receptacle at concesseion bar. Remove and replace with approved (stranded cable) wiring.
Due 15 July 2016
Resolved 15 May 2019
Lifesaving › Buoyant Apparatus › Pendant
Issued 22 June 2016 Resolved
Pendants were coiled and too stiff to unravel. Renew pendants
Due 18 July 2016
Resolved 19 July 2017
Lifesaving › Buoyant Apparatus › Lifeline
Issued 22 June 2016 Resolved
Lifeline around aft starboard buoyant apparatus deteriorting. Renew Lifeline
Due 8 July 2016
Resolved 30 July 2017
Resolution: lifeline renwed
Operations/Management › Equipment Service/Testing › EPIRB
Issued 18 June 2014 Resolved
EPIRB registration expired.
Due 1 July 2014
Resolved 2 July 2014
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 18 June 2014 Resolved
Rigid buoyant apparatus paint and vessel name was faded.
Due 1 July 2014
Resolved 2 July 2014
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 June 2014 Resolved
Improper cable installed for galley food warmer. Renew with authorized type cable.
Due 1 July 2014
Resolved 2 July 2014
Lifesaving › Buoyant Apparatus › Painter
Issued 18 June 2014 Resolved
Painter was tied to lifeline and not attached to B/A body.
Due 1 July 2014
Resolved 2 July 2014
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 18 June 2014 Resolved
Rejected 09 adult PFDs, renew 09 PFDs for a total of 158.
Due 1 July 2014
Resolved 2 July 2014
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 18 June 2014 Resolved
Excess water in bilge of #3 void space.
Due 1 July 2014
Resolved 2 July 2014
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 18 June 2014 Resolved
EPIRB hydrosatatic release expired.
Due 1 July 2014
Resolved 2 July 2014
Communications › Alarms/Indicators › Bilge Alarm
Issued 18 June 2014 Resolved
bilge alarms at operator's station not properly labelled.
Due 1 July 2014
Resolved 2 July 2014
Stability › Unintentional Flooding › General
Issued 16 May 2012 Resolved
Install bilge high level alarms for steerring/lazarette and void #4 (shaft tube) space in accordance with 46 CFR 182.530
Due 15 June 2012
Resolved 12 June 2012
Resolution: High level alarms with visual and audible indicators installed.
Communications › Radio Communications › EPIRB
Issued 16 May 2012 Resolved
Catagory I 406 mhz float free EPIRB not onboard.
Due 18 May 2012
Resolved 18 May 2012
Resolution: New EPIRB purchased, registered, and properly mounted.
Electrical › Electric Generation Source (service) › Panelboard
Issued 16 May 2012 Resolved
Ammeter gage glasses were loose and obstructing meter travel. Renew gages, or gage glass or make repairs to same.
Due 30 June 2012
Resolved 18 June 2013
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 16 May 2012 Resolved
Drug testing program was administered by owner/operator with several records not available and crew enrollment not 100% verifiable and EAP not properly administered.
Due 29 June 2012
Resolved 12 June 2012
Resolution: O/O elected to enroll with consortium.
Engineering › Pressure Vessel › Maximum Allowable Working Pressure
Issued 16 May 2012 Resolved
WayWolff H/W Heater/boiler is not operational for testing. Unit must be disconnected / disabled to prevent inadvertent energizing and operation.
Due 12 June 2012
Resolved 12 June 2012
Resolution: Electrical and fuel systems disconnected, boiler disabled.
Navigation › Piloting/Steering › Magnetic Compass
Issued 11 June 2008 Resolved
Magnetic Compass was not in working order due to wiring problem.
Due 25 June 2008
Resolved 19 May 2009
Resolution: Compass is in working condition.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 11 June 2008 Resolved
Oil pressure and water temperature gauges inop due to wiring problem.
Due 25 June 2008
Resolved 19 June 2009
Resolution: Oil pressure gauges found sat. See narrative for details.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 13 June 2006 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 14 June 2006
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Engineering › Lubricating Oil Service System › Gauge
Issued 18 August 2005 Resolved
Repair gauge in pilot house. Owner granted 30 day extension to original due date of 22 August 2005.
Action required: 705 - Other - as specified
Due 22 September 2005
Resolved 2 September 2005
Resolution: Electrical short was corrected and gauge was operational.
Lifesaving › Lifebuoys › Serviceable
Issued 21 July 2005 Resolved
Repair cracks in 2 lifebuoys or replace them.
Action required: 705 - Other - as specified
Due 22 August 2005
Resolved 2 September 2005
Resolution: replaced lifebuoys
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 21 July 2005 Resolved
Provide lifesaving equipment maintenance record book.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2005
Resolved 2 September 2005
Resolution: Provided lifesaving equipment maintenance record book
Lifesaving › Hand Flares › Not on Board
Issued 21 July 2005 Resolved
Provide three additional orange smoke flares (total of six).
Action required: 705 - Other - as specified
Due 22 August 2005
Resolved 2 September 2005
Resolution: Provided additional hand flares
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 21 July 2005 Resolved
Attach light to buoyant apparatus.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2005
Resolved 22 July 2005
Resolution: Attached light to buoyant apparatus
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 21 July 2005 Resolved
Replace retro reflective material and repair straps on 140 adult and 18 children PFD's. Limited to 51 adults and 37 children total.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2005
Resolution: Reparied all 140 adult and 18 children PFD''s
Personnel › Certificates/Documents/Licenses › License, Master
Issued 21 July 2005 Resolved
Provide original license for master. Copy is not acceptable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2005
Resolution: Provided original license for master.
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 21 July 2005 Resolved
Provide proof of CPR/First aid training for 50% of crew.
Action required: 705 - Other - as specified
Due 22 August 2005
Resolved 2 September 2005
Resolution: Provided proof of CPR and First aid
Navigation › Piloting/Steering › Magnetic Compass
Issued 21 July 2005 Resolved
Provide light for compass prior to operating after sunset.
Action required: 705 - Other - as specified
Resolved 22 July 2005
Resolution: Provided light for compass
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 July 2005 Resolved
Replace expired eye wash in first aid kit.
Action required: 705 - Other - as specified
Due 22 August 2005
Resolved 2 September 2005
Resolution: Provided new eye wash
Engineering › Freshwater System (intermediary cooling) › Piping
Issued 21 July 2005 Resolved
Double clamp yellow pipe on stbd engine.
Action required: 705 - Other - as specified
Due 22 August 2005
Resolved 2 September 2005
Resolution: Clamps added to pipe.
Electrical › Lighting (service) › Lighting Fixture
Issued 21 July 2005 Resolved
Replace broken glass globe on light in dining room.
Action required: 705 - Other - as specified
Due 22 August 2005
Resolved 2 September 2005
Resolution: Replaced globe with new one
Engineering › Lubricating Oil Service System › Gauge
Issued 21 July 2005 Resolved
Repair oil pressure gauge in the pilot house.
Action required: 705 - Other - as specified
Due 22 August 2005
Resolved 18 August 2005
Resolution: Vessel owner requested 30 day inspection for this deficiency. Extension granted. New due date: 22 September 2005.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 10 August 2004 Resolved
Replace damaged insulation in engine room
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 April 2005
Resolved 21 July 2005
Resolution: Damaged insulation has been replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 July 2004 Resolved
Remove all deadend wires from vessel
Condition: Improper/Lack of Maintenance
Due 6 August 2004
Resolved 10 August 2004
Resolution: All noted dead-ended wires were removed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 July 2004 Resolved
Remove extension cords and household wires from refrigerator and compressor and replace with approved marine grade cable.
Condition: Improper Installation
Due 6 August 2004
Resolved 10 August 2004
Resolution: Wiring hard wired and replaced with Marine Grade wire.
Electrical › Lighting (service) › Lighting Fixture
Issued 7 July 2004 Resolved
Remove fluourescent light fixture in engine room.
Condition: Placed in Improper Service
Due 6 August 2004
Resolved 10 August 2004
Resolution: Fluourescent light fixture removed.
Documentation › Certificates/Documents › FCC SSL
Issued 7 July 2004 Resolved
Provide a valid FCC certificate.
Condition: Unknown
Due 6 August 2004
Resolved 10 August 2004
Resolution: Valid FCC certificate posted.
Documentation › Certificates/Documents › Stability Letter
Issued 7 July 2004 Resolved
Properly post stability letter.
Condition: Improper Installation
Due 6 August 2004
Resolved 10 August 2004
Resolution: Stability Letter properly Posted.
Lifesaving › Lifebuoys › Stowage
Issued 7 July 2004 Resolved
Reposition lifering on aft upperdeck in an appropriate mounting bracket.
Condition: Improper Installation
Due 6 August 2004
Resolved 10 August 2004
Resolution: Life ring repositioned.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 7 July 2004 Resolved
Provide 60' non-kinking line for lifering.
Condition: Improper Installation
Due 6 August 2004
Resolved 10 August 2004
Resolution: 60'' non- kinking line has been attached.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 7 July 2004 Resolved
Prove that all vessel crew is enrolled in a DAPI program.
Condition: Unknown
Due 6 August 2004
Resolved 10 August 2004
Resolution: Owner/operator enrolled in consortium
Documentation › Markings/Placards › Capacity Marking
Issued 7 July 2004 Resolved
Post Passenger limit on upper deck stairwells.
Condition: Unknown
Due 6 August 2004
Resolved 10 August 2004
Resolution: Passenger count of 100 posted in stairwell to upper deck.
Documentation › Markings/Placards › Injury Placard
Issued 7 July 2004 Resolved
Post life Jacket donning placcards at all stowage areas.
Condition: Unknown
Due 6 August 2004
Resolved 10 August 2004
Resolution: Life jacket donning placards posted at stowage lockers.
Electrical › Electrical Distribution System (service) › Cable
Issued 7 July 2004 Resolved
Provide Electrical diagram for all electrical upgrades with approved marine grade cable for refrigerator and compressors. Diagram must be approved marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 August 2004
Resolved 10 August 2004
Resolution: Diagram provided.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 7 July 2004 Resolved
Provide current charts of transit area.
Condition: Unknown
Due 6 August 2004
Resolved 10 August 2004
Resolution: Charts provided.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 7 July 2004 Resolved
Affix structural fire insulation to engine room overhead during drydock period or operating Spring 2005.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 April 2005
Resolved 21 July 2005
Resolution: Fire insulation has been installed in the engine room overhead.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 7 July 2004 Resolved
Provide a means to have Passenger count on shore prior to each voyage.
Condition: Unknown
Due 6 August 2004
Resolved 10 August 2004
Resolution: Passenger count keep at small shed alongside vessel''s moorings.
Lifesaving › Hand Flares › Condition
Issued 11 June 2002 Resolved
Prior to carry passengers for hire must provide 6 hand held flares in accordance with 46CFR180.68.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2002
Resolution: Vessel owner bought new flares prior to completion of the Inspection for Certification.
Lifesaving › Buoyant Apparatus
Issued 11 June 2002 Resolved
Renew vessel name and BA capacity markings on all Bouyant Appratus. LEGACY COMPONENT DESC: Markings
Due 15 July 2002
Resolved 14 June 2002
Resolution: Markings renewe.
Lifesaving › Buoyant Apparatus
Issued 11 June 2002 Resolved
Renew all bouyant appratus pendants and weak links, as needed, on all BAs LEGACY COMPONENT DESC: pendants and weak links
Condition: Improper/Lack of Maintenance
Due 15 July 2002
Resolved 14 June 2002
Resolution: all pendants and weak links were renewed/replaced
Fire Fighting › Miscellaneous Items
Issued 11 June 2002 Resolved
Renew vessel name stencile on the fire axe handle. LEGACY COMPONENT DESC: Fire Axe
Due 15 July 2002
Resolved 14 June 2002
Resolution: stencile renewed.
Electrical
Issued 11 June 2002 Resolved
Renew/replace worn/exposed wires (public address system) near the aft ladderwell and upper deck. LEGACY COMPONENT DESC: Worn Wires
Condition: Improper/Lack of Maintenance
Due 15 July 2002
Resolved 14 June 2002
Resolution: all wires renewed/replaced as neeeded
Lifesaving
Issued 5 June 2001 Resolved
PROPERLY SECURE ELECTRIC COFFEE MAKER AND ELECTRIC PORTABLE FOOD WARMER.
Condition: Unknown
Due 5 July 2001
Resolved 5 July 2001
Construction/Loadline
Issued 5 June 2001 Resolved
PROVIDE PROPER BILGE VALVE MANIFOLD PLACARDING TO INDICATE WHICH SPACE IS CONTROLLED BY WHICH INDIVIDUAL VALVE.
Condition: Unknown
Due 5 July 2001
Resolved 5 July 2001
Lifesaving
Issued 5 June 2001 Resolved
PROVIDE PROPER PFD STOWAGE LOCKER/CONTAINER PLACARDING. SPECIFICALLY, INDICATE SIZE AND NUMBER OF PFDS STOWED IN EACH LOCKER/CONTAINER.
Condition: Unknown
Due 5 July 2001
Resolved 5 July 2001
Electrical
Issued 21 June 2000 Resolved
PRIOR TO OPERATING W/ PASSENGERS, MAKE PROPER ELECTRICAL CORRECTIONS TO THEFOLLOWING: 1. HANGING WIRES IN WAY OF THE MIDSHIPS LADDER 2. 110V WIRES ANDLIGHTS ON THE UPPER DECK OVERHEAD 3. IMPROPER SLICE/EXPOSED WIRES IN THE UNISEX HEAD 4. WIRES AT THE 12V BATTERY 5. COVER ELECTRICAL BOX AT FURNACE.
Condition: Unknown
Due 30 June 2000
Resolved 7 July 2000
Engineering
Issued 21 June 2000 Resolved
REPLACE MISSING EXHAUST LAGGING ON VESSEL'S GENERATOR.
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Construction/Loadline
Issued 21 June 2000 Resolved
AT NEXT DRYDOCK, PROPERLY CLOSE UNUSED TOLIET OPENING IN THE FUEL TANK COMPARTMENT.
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Construction/Loadline
Issued 21 June 2000 Resolved
CLEAN ALL BILGE SUCTION STRAINERS.
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Fire Fighting
Issued 15 June 1998 Resolved
VESSEL MAY NOT CARRY MORE THAN 150 PASSENGERS UNTIL ALL STRUCTURAL FIRE PROTECTION DEFICIENCIES OUTLINED IN MSD GRAND HAVEN LETTER DTD 10MAY98 ARE RESOLVED TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Electrical
Issued 5 July 1997 Resolved
Provide metal retaining clips for all wire runs in engine room every 2 ft.
Condition: Unknown
Due 5 July 1997
Resolved 5 July 1997
Electrical
Issued 5 July 1997 Resolved
Provide and install proper guards for generator pulleys and secure main diesel engine machinery guards.
Condition: Unknown
Due 5 July 1997
Resolved 5 July 1997
Lifesaving
Issued 5 July 1997 Resolved
Provide proper operation of Class "C" EPIRB prior to operating more than 3 miles offshore.
Condition: Unknown
Due 5 July 1997
Resolved 5 July 1997
Electrical
Issued 5 July 1997 Resolved
Provide and install cover for 12volt fuse box in wheelhouse and properly label all circuits.
Condition: Unknown
Due 5 July 1997
Resolved 5 July 1997
Lifesaving
Issued 5 July 1997 Resolved
Provide 28 properly labeled and retroflectived Type 1 PFD's prior to carriage of more than 190 total persons.
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Engineering
Issued 5 July 1997 Resolved
Replace flexible fuel hose on starboard engine from external filter to fuelpump and from engine filter to inboard cylinder bank with acceptable wire braided swedged lock fuel hose.
Condition: Unknown
Due 5 July 1997
Resolved 5 July 1997
Engineering
Issued 5 July 1997 Resolved
Properly repair or replace as original both main diesel engine air intakes to prevent excessive oil blow by.
Condition: Unknown
Due 5 July 1997
Resolved 5 July 1997
Documentation
Issued 5 August 1996 Resolved
Provide letter of designation for senior deckhand of vessel, as per NVIC 1-91.
Condition: Unknown
Due 5 August 1996
Resolved 5 August 1996
Navigation
Issued 25 June 1996 Resolved
PROVIDE UPDATED CHARTS FOR LOCAL OPERATING AREA.
Condition: Unknown
Due 10 July 1996
Resolved 10 July 1996
Lifesaving
Issued 25 June 1996 Resolved
PROVE PROPER OPERATION OF WATER LIGHT FOR BUOYANT APPARATUS.
Condition: Unknown
Due 10 July 1996
Resolved 10 July 1996
Navigation
Issued 25 June 1996 Resolved
INSTALL STERN RUNNING LIGHT IN ACCORDANCE WITH THE NAVRULES.
Condition: Unknown
Due 25 June 1996
Resolved 25 June 1996
Lifesaving
Issued 25 June 1996 Resolved
PROVIDE 6 ADULT AND 1 CHILD SIZE LIFE JACKET PRIOR TO CARRIAGE OF MORE THAN211 PERSONS.
Condition: Unknown
Due 10 July 1996
Resolved 10 July 1996
Lifesaving
Issued 25 June 1996 Resolved
POST DONNING PLACARDS FOR HORSE COLLAR LIFE JACKETS IN CONSPICUOUS PLACES, ACCESSIBLE TO PASSENGERS AND CREW.
Condition: Unknown
Due 10 July 1996
Resolved 10 July 1996
Fire Fighting
Issued 25 June 1996 Resolved
PROVE PROPER OPERATION OF HAND FIRE PUMP PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 25 June 1996
Resolved 25 June 1996
Engineering
Issued 25 June 1996 Resolved
PROPERLY LABEL EMERGENCY FUEL SHUT OFF VALVE DIRECTION.
Condition: Unknown
Due 10 July 1996
Resolved 10 July 1996
Engineering
Issued 31 October 1995 Resolved
CONDUCT HYDRO TEST OF AIR RECEIVER TO 1.25xMAWP OR 250PSI IN THE PRESENCE OF A CG MARINE INSPECTOR NLT 30APR96, BUT PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 31 October 1995
Resolved 31 October 1995
Lifesaving
Issued 31 October 1995 Resolved
PROVIDE 17 SERVICEABLE ADULT TYPE I LIFE PRESERVERS NLT 30APR96, BUT PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 31 October 1995
Resolved 31 October 1995
Engineering
Issued 1 August 1995 Resolved
CONDUCT HYDRO TEST OF AIR RECEIVER TO 1.5 X MAWP OR 300PSI IN THE PRESENCE OF A CG MARINE INSPECTOR NLT 30SEP95.
Condition: Unknown
Due 1 August 1995
Resolved 1 August 1995
Lifesaving
Issued 20 June 1995 Resolved
Replace (2) Ring Life Buoy 60 FT nylon lines with (2) 60 FT floatable lines.
Condition: Unknown
Due 20 June 1995
Resolved 20 June 1995
Lifesaving
Issued 20 June 1995 Resolved
Provide 17 serviceable adult Type I life preservers prior to carrying more than 191 passengers, but not later than the compliance date.
Condition: Unknown
Due 20 June 1995
Resolved 20 June 1995
Lifesaving
Issued 20 June 1995 Resolved
Properly label all life preserver storage containers with number and type of jackets (adult,child) stowed therein.
Condition: Unknown
Due 20 June 1995
Resolved 20 June 1995
Electrical
Issued 20 June 1995 Resolved
Relabel AC power distribution panel directory.
Condition: Unknown
Due 20 June 1995
Resolved 20 June 1995
Engineering
Issued 20 June 1995 Resolved
Properly label engine room air receiver tank in accordance with 46 CFR 54.10-20.
Condition: Unknown
Due 20 June 1995
Resolved 20 June 1995
Engineering
Issued 30 August 1994 Resolved
PROVIDE MAWP OF AIR RECEIVER AND PROVE SATISFACTORY HYDRO TEST.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Lifesaving
Issued 30 August 1994 Resolved
PROVIDE 7 ADULT AND 1 CHILD PFD.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Lifesaving
Issued 30 August 1994 Resolved
RELABEL BUOYANT APPARATUS WITH CAPACITY AND VESSEL NAME.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Lifesaving
Issued 30 August 1994 Resolved
PROVIDE APPROVED WATER LIGHT FOR BUOYANT APPARATUS.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Navigation
Issued 30 August 1994 Resolved
PROVIDE REQUIRED CURRENT PUBLICATIONS AND CHARTS.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Navigation
Issued 30 August 1994 Resolved
PROVIDE CURRENT DEVIATION CARD FOR COMPASS.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Engineering
Issued 30 August 1994 Resolved
REPAIR TACHOMETER FOR STBD ENGINE.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Navigation
Issued 30 August 1994 Resolved
PROVIDE LOCKING PIN FOR PORT SIDE STEERING ARM.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Lifesaving
Issued 30 August 1994 Resolved
PROVIDE DATED BATTERIES FOR EPIRB.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Lifesaving
Issued 30 August 1994 Resolved
PROVIDE 1 HAND HELD RED FLARE.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Engineering
Issued 30 August 1994 Resolved
REPAIR STBD SIDE ENGINE ROOM VENT DUCT.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Engineering
Issued 21 October 1993 Resolved
Renew ships service generator fuel return line hose using an approved material. Repair must be completed prior to carrying passengers for the 1994 operating season._x001C_ See also MIDR item 2 for case MI93026918.
Condition: Unknown
Due 21 October 1993
Resolved 21 October 1993
Electrical
Issued 18 June 1993 Resolved
Renew or repair wiring items as pointed out by inspector.
Condition: Unknown
Due 18 June 1993
Resolved 18 June 1993
Lifesaving
Issued 18 June 1993 Resolved
Provide one additional adult PFD. Vessel is limited to 216 total persons until PFD is provided.
Condition: Unknown
Due 18 June 1993
Resolved 18 June 1993
Engineering
Issued 18 June 1993 Resolved
Renew ships service generator fuel supply and return hoses with a coast guard approved hose.
Condition: Unknown
Due 18 June 1993
Resolved 18 June 1993
Lifesaving
Issued 16 June 1992 Resolved
RENEW ALL PENDANTS ON ALL SIX BUOYANT APPARATUS.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Lifesaving
Issued 16 June 1992 Resolved
PROVIDE 12 EACH ADULT TYPE I PFD'S.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Lifesaving
Issued 13 December 1990 Resolved
PROVIDE 6 ADDITIONAL PADDLES FOR LIFEFLOATS AND LASH ALL PADDLES TO INSIDESOF LIFEFLOATS.
Condition: Unknown
Due 13 December 1990
Resolved 13 December 1990
Electrical
Issued 13 December 1990 Resolved
RENEW BATTERIES FOR S/S GENERATOR.
Condition: Unknown
Due 13 December 1990
Resolved 13 December 1990
Electrical
Issued 13 December 1990 Resolved
REMOVE NON-APPROVED SPLICE FROM ELECTRICAL SHORE TIE CABLE.
Condition: Unknown
Due 13 December 1990
Resolved 13 December 1990
Navigation
Issued 25 May 1990 Resolved
PROVE PROPER OPERATION OF ENGINE ROOM AIR RECEIVER RELIEF.
Condition: Unknown
Due 25 May 1990
Resolved 25 May 1990
Lifesaving
Issued 25 May 1990 Resolved
LABEL ENGINE ROOM ESCAPE HATCH ABOVE AND BELOW AS PER 46 CFR 185.30-15.
Condition: Unknown
Due 25 May 1990
Resolved 25 May 1990
Fire Fighting
Issued 25 May 1990 Resolved
PROVIDE ONE HAND FIRE AND BILGE PUMP WITH 5 G.P.M. CAPACITY AND SUCTION AND DISCHARGE HOSES.
Condition: Unknown
Due 25 May 1990
Resolved 25 May 1990
Fire Fighting
Issued 25 May 1990 Resolved
PROVIDE SPANNER WRENCH FOR FIRE STATION NUMBER 1.
Condition: Unknown
Due 25 May 1990
Resolved 25 May 1990
Lifesaving
Issued 25 May 1990 Resolved
RENEW OR REPAIR WATERLIGHT ON BOUYANT APPARATUS.
Condition: Unknown
Due 25 May 1990
Resolved 25 May 1990
Lifesaving
Issued 22 May 1989 Resolved
VESSEL IS LIMITED TO 162 ADULTS ON BOARD UNTIL ADDITIONAL PFD'S ARE INSPECTED AND APPROVED NOT LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 22 May 1989
Resolved 22 May 1989
Lifesaving
Issued 22 May 1989 Resolved
VESSEL IS LIMITED TO 13 CHILDREN ON BOARD UNTIL ADDITIONAL PFD'S ARE INSPECTED AND APPROVED NOT LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 22 May 1989
Resolved 22 May 1989
Construction/Loadline
Issued 22 May 1989 Resolved
MARK EMERGENCY ESCAPE HATCH AS REQUIRED BY REGULATIONS AND DISCUSSED WITH MARINE INSPECTOR NOT LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 22 May 1989
Resolved 22 May 1989
Engineering
Issued 22 May 1989 Resolved
PROVIDE ADDITIONAL BRACING FOR SAFETY GUARDS IN FRONT OF MAIN ENGINE ALTERNATORS NOT LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 22 May 1989
Resolved 22 May 1989
Electrical
Issued 18 May 1988 Resolved
REPLACE BROKEN PROTECTIVE LIGHT GLOBE NO LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 18 May 1988
Resolved 18 May 1988
Documentation
Issued 18 May 1988 Resolved
PROVIDE EVIDENCE OF OBTAINING AN UP-TO-DATE GREAT LAKES AGMT. RADIO CERTIFICATE NO LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 18 May 1988
Resolved 18 May 1988
Construction/Loadline
Issued 18 May 1988 Resolved
REPLACE TWO (2) BROKEN BRIDGE WINDOWS NO LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 18 May 1988
Resolved 18 May 1988

Casualty record · 1

1 July 2017Routine · role: Involved in a Marine Casualty · activity 6236327
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

M.V. PORT CITY PRINCESS (2017). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.