BEI HAI is a 1995 freight ship. The Coast Guard has recorded 24 inspections since 1997, most recently in April 2016, along with 4 deficiencies and 3 operational controls.

Records from 1997 to 2016. Most recent: inspection, 22 April 2016.

Built
1995
Last inspected
22 April 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9117698 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
452761
Flag
PANAMA
—
Maury page id
psix-452761

Inspections, by type

…with no type recorded13
Years with a record 15 calendar years (1997–2016)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it26123 - Convention (Subpart B), Gross Ton
14853 - Convention (Subpart B), Net Ton
45178 - Dead Weight, Metric Ton
52844 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 24

22 April 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination · COE-Dockside
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5859626
6 January 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5792011
17 May 2012 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4313635
24 September 2010 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3856499
13 March 2009 Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3432801
19 August 2008 PII Safety Exam · Ballast Water Examination · MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3292749
9 March 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2885103
3 March 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2881011
1 March 2007 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2880014
24 July 2006 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2723759
17 September 2005 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2494645
15 December 2004 MARPOL Annex I Examination · Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2259832
6 July 2004 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2123077
6 July 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2123811
27 April 2003 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1781279
15 August 2002 Annual Inspection · Ballast Water Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1662110
20 August 2001 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 293006
15 March 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 288168
24 January 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1483462
13 May 2000 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 277711
1 December 1999 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 435314
12 February 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 89332
29 January 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 425045
28 May 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 404126

Deficiency record · 4

Deck/Cargo › Cargo Stowage › General
Issued 19 August 2008 Resolved
Approximately, 5 cubic meters of Alumina, a previous cargo, is being stowed in the Bo'sun hold. According to the Chem Alert Report provided by the vessel, the Alumina is improperly packed in open plastic bags, unmarked, without documentation referencing presence onboard.
Action required: 705 - Other - as specified
Due 21 August 2008
Resolved 21 August 2008
Resolution: All Alumina cargo residuals have been removed from the vessel
Fire Fighting › Structural - A Class Divisions › Main Galleys
Issued 19 August 2008 Resolved
All 4 Class "A" doors located in the galley do not self close. Air tight gaskets are missing or damaged. Doors do not provide adequate resistance to smoke or fire equivalent to that of the bulkhead
Action required: 705 - Other - as specified
Due 21 August 2008
Resolved 21 August 2008
Resolution: The self closing devices and gaskets have been repaired. Visual inspection and function test carried out by the undersigned with satisfaction.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 19 August 2008 Resolved
Class "A" bulkhead has an approximately 8"x14 opening above engineer's workshop door to accomodate a winch rail from the engineer's workshop to engine room. Bulkhead does not meet applicable fire integrity requirements to prevent the passage of fire and smoke ino space.
Action required: 705 - Other - as specified
Due 21 August 2008
Resolved 21 August 2008
Resolution: According to the arrangement and approved fire control plan, the bulkhead between engineer''s workshop and engine room is not necessarily to be class "A". The insulation on the bulkhead was supposed to be noise and thermal insulation.
Navigation › Collision/Grounding Avoidance › Radar
Issued 24 January 2001 Resolved
PCB board on radar was faulty. Mackay Communications attended vessel and replaced board and satisfactorily tested radar.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2002
Resolution: Vessel restriction was rescinded.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.