← All vessels
MR. C
Passenger (Inspected) · Passenger Ship class · Built 1960s · USCG Southwest District (CGD-SW) · Other hulls named MR. C
MR. C is a 1966 passenger vessel (inspected). The Coast Guard has recorded 61 inspections since 1985, most recently in December 2017, along with 110 deficiencies and 1 operational control.
Records from 1985 to 2017. Most recent: inspection, 13 December 2017.
- Built
- 1966
- Last inspected
- 13 December 2017
- Documentation
- Expired · documentation file of 10 September 2026
- Deficiencies
- 110 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
504276
WDF3455
45278
Flag
UNITED STATES
367325120, 367440080 (licence lapsed)
Maury page id
psix-45278
Inspections, by type
…with no type recorded5
Years with a record
30 calendar years (1985–2017)
The 61 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)50.0 ft × 16.4 ft × 6.1 ft
Registered tonnagegross 32 / net 22
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · GARDENA, CA, UNITED STATES · built 1966
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLONG BEACH, CA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it32 - Regulatory (Subpart C or D), Gross Ton
22 - Regulatory (Subpart C or D), Net Ton
22 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDF3455MMSI 367440080 · expired · compulsorily equipped · granted 19 February 2010, cancelled 25 April 2020
WDE2432MMSI 367325120 · expired · compulsorily equipped · granted 4 December 2007, cancelled 3 February 2018
WY5572MMSI not assigned · expired · compulsorily equipped · granted 6 October 1997, cancelled 19 February 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 61
13 December 2017
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6324065
15 December 2015
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5783362
21 May 2012
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4293932
6 July 2011
Annual Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4081793
19 February 2010
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3671158
3 December 2009
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3644218
9 April 2009
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3448918
19 March 2009
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3435763
3 April 2008
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3156914
11 May 2007
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2934097
11 April 2007
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2861193
26 March 2007
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2893480
27 June 2006
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2693176
12 June 2006
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2610619
24 March 2005
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2310723
9 April 2004
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2036245
9 April 2004
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2041600
6 February 2004
Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2001915
24 March 2003
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1762277
21 March 2003
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1762199
9 May 2002
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1623011
9 May 2001
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1379493
23 April 2001
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1384929
22 January 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 754213
19 January 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 196594
11 May 2000
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1391302
22 December 1999
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1365513
11 May 1999
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1386496
22 March 1999
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1372554
9 February 1999
Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1127056
26 May 1998
Hull Examination · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1390787
28 May 1997
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1390517
27 February 1997
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1394680
29 May 1996
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1458304
29 February 1996
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 885551
25 August 1995
Hull Examination · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1385527
24 June 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 89850
17 May 1995
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1392227
6 June 1994
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1015231
25 March 1994
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1166384
18 February 1994
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1163781
30 December 1993
Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1164152
2 July 1993
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 851204
2 June 1993
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1153586
4 October 1992
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 95905
5 June 1992
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 948976
27 May 1992
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1267024
7 June 1991
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1242527
30 November 1990
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1229515
27 June 1990
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1218754
7 June 1990
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1235615
7 June 1989
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1043521
26 May 1989
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 897055
13 July 1988
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1209849
8 June 1988
Deficiency Check · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 894176
17 November 1987
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1024248
4 June 1987
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1022311
20 November 1986
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1329494
26 June 1986
Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1313995
10 June 1986
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1008964
6 June 1985
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1297287
Deficiency record · 110
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 21 May 2012
Resolved
Provide proof of pre-employment drug testing.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 21 May 2012
Resolved
Provide proof of MIS report submission.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 21 May 2012
Resolved
Provide Substance Abuse Professional contact information.
Stability › Incline Test › General
Issued 21 May 2012
Resolved
Conduct SST within 90 days.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 July 2011
Resolved
Replace reflective tape and place vessel's name on the ring life buoy.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 19 February 2010
Resolved
Provide original Certification Of Documentation on board. 46 CFR 67.7
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 19 February 2010
Resolved
Complete satisfactory DAPI audit by USCG Marine Inspector 46 CFR 16
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 19 February 2010
Resolved
Provide emergency training & drill logs 46 CFR 185.520, 185.524
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 19 February 2010
Resolved
Provide FCC Marine Radio Operator permit per 47 CFR 80.159
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 19 February 2010
Resolved
Provide Rules of the Road per 46 CFR 184.420
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 19 February 2010
Resolved
Provide Tide Tables & Tidal Current tables per 46 CFR 184.420
Lifesaving › Visual Distress Signals (General) › Quantity
Issued 19 February 2010
Resolved
Provide 6 Flares & 6 day smokes in portable watertight container marked "Distress Signals" per 46 CFR 180.68
Lifesaving › Rigid Liferafts › Weak Link
Issued 19 February 2010
Resolved
Secure Life Float weak link To vsl per 46 CFR 180.37
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 February 2010
Resolved
Provide USCG approved "First-Aid" kit per 46 CFR 184.710
Lifesaving › Liferaft Equipment › Instructions (survival)
Issued 19 February 2010
Resolved
Post Lifejacket donning instruction placard per 46 CFR 185.516
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 February 2010
Resolved
Replace electrical panel door located on bridge per 46 CFR 183.330
Engineering › Bilge Water Management System › Pump
Issued 19 February 2010
Resolved
Prove proper operation of vsl's fixed bilge system per 46 CFR 182.510
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 February 2010
Resolved
Throughout vsl ensure electrical wires have metal supports spaced not more than 24 inches per 46 CFR 183.330
Operations/Management › Drills/Instruction › Fire
Issued 19 February 2010
Resolved
Conduct fire drill.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 19 February 2010
Resolved
Complete man overboard drill.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 19 February 2010
Resolved
Supervisor has not completed required 1 hour supervisor EAP training.
Communications › Radio Communications › EPIRB
Issued 3 April 2008
Resolved
Provide current EPIRB Registration and sticker.
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 3 April 2008
Resolved
Provide current First-Aid and CPR training certification.
Engineering › Bilge Water Management System › Manifold
Issued 3 April 2008
Resolved
Repaint bilge mainfold valve handles to match existing color code system.
Engineering › Bilge Water Management System › Hose
Issued 3 April 2008
Resolved
Provide non-collapsible hose for manual electric bilge pumps in engine room, bunk room and forepeak.
Communications › Alarms/Indicators › Bilge Alarm
Issued 3 April 2008
Resolved
Repair high level bilge alarm in forepeak.
Fire Fighting › Fire Bucket › Availability
Issued 11 April 2007
Resolved
Provide three (3) 9.5 liter Fire buckets with attached lanyards and stenciled "FIRE BUCKET".
Fire Fighting › Remote Fuel Shutoff › General
Issued 11 April 2007
Resolved
Repair/Renew starboard fuel shutoff valve.
Construction/Loadline › Hull › Hull Plating
Issued 26 March 2007
Resolved
Conduct a satisfactory underway checkride to the satisfaction of the attending CG Marine Inspector.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 12 June 2006
Resolved
Provide front cover to distribution panel in wheelhouse.
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 June 2006
Resolved
Remove dead end wires in passenger accommodations.
Lifesaving › Hand Flares › Quantity
Issued 12 June 2006
Resolved
Provide one day smoke distress signal.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 12 June 2006
Resolved
Provide 13 new PFD to replace condemed PFD's.
Construction/Loadline › Hull › Hull Plating
Issued 24 March 2005
Resolved
Repair hole on port side, aft on boat.
Construction/Loadline › Hull › Strut/Cross Tie
Issued 24 March 2005
Resolved
Scrape and treat rot in deck from the laz. on the port side and by the hatch.
Lifesaving › Lifejacket/PFD (General)
Issued 9 April 2004
Resolved
Failed one child size lifejacket; reduced child passenger count to four until corrected. LEGACY COMPONENT DESC: Condition
Lifesaving › Rigid Liferafts
Issued 9 April 2004
Resolved
The lashings attaching the lifefloat to the netting were worn/frayed.
Communications › Radio Communications
Issued 13 February 2004
Resolved
Meet FCC MF radio requirements for 100 mile route. LEGACY COMPONENT DESC: MF Radio
Documentation › Logs/Records
Issued 24 March 2003
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Engineering › Bilge Water Management System
Issued 21 March 2003
Resolved
Replace deteriorated flexible hose on bilge suction piping in engine room, just forward of yellow suction valve. LEGACY COMPONENT DESC: Hose
Engineering › Bilge Water Management System
Issued 21 March 2003
Resolved
Replace corroded bilge suction piping in bow, forward of collision bulkhead. LEGACY COMPONENT DESC: Piping
Engineering › Bilge Water Management System › Piping
Issued 21 March 2003
Resolved
Replace corroded bilge suction piping in Engine room which takes suction from lazarette.
Construction/Loadline › Hull › Stiffener
Issued 21 March 2003
Resolved
Replace all fasteners on both butt blocks in bunk room, just aft of bilge pump, on the first plank above keel on both port and stbd sides.
Operations/Management › Drug and Alcohol Testing
Issued 9 May 2002
Resolved
EAP, program not implemented. LEGACY COMPONENT DESC: EAP Display Requirements
Electrical › Electrical Distribution System (service)
Issued 9 May 2002
Resolved
Engineroom fuse bank not installed with cover, as required. LEGACY COMPONENT DESC: Fuse
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 9 May 2002
Resolved
Documentation to certify inspection, missing. LEGACY COMPONENT DESC: Tanks
Lifesaving › Buoyant Apparatus
Issued 9 May 2002
Resolved
Waterlight inoperable.
Engineering › Bilge Water Management System
Issued 9 May 2002
Resolved
Bilge piping, suction line in engineroom burst/hole. LEGACY COMPONENT DESC: Piping
Lifesaving › Lifejacket/PFD (Type II)
Issued 9 May 2002
Resolved
missing one lifejacket. LEGACY COMPONENT DESC: Quantity
Fire Fighting › Emergency Fire Pumps
Issued 9 May 2002
Resolved
Fire buckets, not provided. LEGACY COMPONENT DESC: Capacity
Accommodation/Occupational Safety
Issued 11 May 2000
Resolved
Make emergency escape hatch from bunk room easily openable from underneath.
Fire Fighting
Issued 11 May 2000
Resolved
Provide a means to secure vents between engine room and lazarette (port andstarboard) and make holes on starboard side gas tight.
Construction/Loadline
Issued 11 May 2000
Resolved
Make all automatic bilge pumps indicate operation at the operating station or disable float switches and remove wiring.
Engineering
Issued 11 May 2000
Resolved
Label both fuel shut off valves with 1 inch lettering and direction of operation.
Fire Fighting
Issued 11 May 2000
Resolved
Have all three B-II fire extinguishers on board that are overdue for 12 year hydrostatic test undergo this test or replace with new extinguishers.
Construction/Loadline
Issued 11 May 2000
Resolved
Ensure lazarette bilge alarm functions (light does not illuminate) and provide audible alarm for all high bilge level lights.
Documentation
Issued 11 May 2000
Resolved
Post all pages of the COI visible to passengers.
Lifesaving
Issued 11 May 2000
Resolved
Provide proof of EPIRB registation with NOAA.
Navigation
Issued 11 May 2000
Resolved
Provide currently corrected charts, light list, and new tide table.
Lifesaving
Issued 11 May 2000
Resolved
Attach each life float to the painter with lines of suitable length to keepthe life floats separate when floating.
Lifesaving
Issued 11 May 2000
Resolved
Provide 3 to 6 foot lanyard for waterlight on the ring buoy.
Electrical
Issued 22 March 1999
Resolved
Provide 15 amp breaker for fixed CO2 system in accordance with 46 CFR 183.340.
Fire Fighting
Issued 22 March 1999
Resolved
Provide ventilation shut down for vents leading to the engine room.
Construction/Loadline
Issued 26 May 1998
Resolved
Rleplace section of missing worm shoe._x001C_ _x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 26 May 1998
Resolved
Repair area of hull, port and stasrboard, along keel affected by worms._x001C_ _x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 26 May 1998
Resolved
Repair engine room hatch coaming to original strength._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 26 May 1998
Resolved
Provide retro-reflective tape as needed for lifejackets prior to 16 JUN 98._x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 26 May 1998
Resolved
At next drydock, have all paint removed fromm exterior hull from the vessel's keel to the turn of the chine.
Lifesaving
Issued 26 May 1998
Resolved
Provide Coast Guard approved first Aid Kit or equivalent prior to 16 Jun98.
Accommodation/Occupational Safety
Issued 29 May 1996
Resolved
Provide locking device for marine sanitation device.
Navigation
Issued 29 May 1996
Resolved
Provide updated local charts.
Lifesaving
Issued 29 May 1996
Resolved
Provide proper size weak link for lifefloats.
Lifesaving
Issued 29 May 1996
Resolved
Provide proper amount of retroreflective tape on lifefloats.
Lifesaving
Issued 29 May 1996
Resolved
Provide proper painters for lifefloats.
Lifesaving
Issued 29 May 1996
Resolved
Provide proper lifelines for lifefloats.
Lifesaving
Issued 29 May 1996
Resolved
Provide proper lifeline on lifering buoy.
Lifesaving
Issued 29 May 1996
Resolved
Replace lanyards attached to lifefloat waterlights.
Construction/Loadline
Issued 25 August 1995
Resolved
Repair leak in hull located in starboard engine room bottom center.
Electrical
Issued 25 August 1995
Resolved
Mount circuit breaker in battery charger in port engine room.
Electrical
Issued 25 August 1995
Resolved
Provide bonding system from all major electrical equipment as per 46CFR183.10-20 and 46CFR183.05-50.
Navigation
Issued 17 May 1995
Resolved
PROVIDE UPDATED CHARTS, COAST PILOT, AND LIGHT LIST.
Engineering
Issued 18 February 1994
Resolved
INSTALL MACHINERY GUARDS ON THE INBOARD SIDE OF BOTH ENGINES AND THE FORWARD SIDE OF THE GENERATOR.
Deck/Cargo
Issued 18 February 1994
Resolved
PROPERLY DOUBLE CLAMP THE HOSE FOR THE FILL STATION PUMP.
Electrical
Issued 18 February 1994
Resolved
CLEAN THE CORROSION ON THE TERMINAL BOARD IN THE BATTERY CHARGER ISOLATOR.
Electrical
Issued 18 February 1994
Resolved
INSTALL PROPER WIRE SUPPORTS ON THE PORT SIDE OF THE ENGINE ROOM.
Construction/Loadline
Issued 18 February 1994
Resolved
CLEAN AND TREAT ROT IN THE ENGINEROOM AND THE LAZZERETE.
Electrical
Issued 18 February 1994
Resolved
REPLACE THE LID ON THE STARBOARD BATTERY BOX.
Deck/Cargo
Issued 18 February 1994
Resolved
PROPERLY MOUNT THE FRESH WATER PUMP IN THE FOREPEAK.
Construction/Loadline
Issued 18 February 1994
Resolved
SECURELY MOUNT THE WIRING AND THE SWITCH TO THE BILGE PUMP IN THE FOREPEAK.
Construction/Loadline
Issued 18 February 1994
Resolved
INSTALL A STOP VALVE NEAR THE COLLISION BULKHEAD IN ACCORDANCE WITH 46 CFR 182.25-5(d).
Unknown
Issued 30 December 1993
Resolved
LOCATE AND ELIMINATE ALL OIL LEAKS IN ENGINE ROOM MACHINERY PRIOR TO CARRYING PASSENGERS.
Unknown
Issued 30 December 1993
Resolved
REMOVE OILY WATER FROM BILGES AND CLEAN OIL RESIDUE FROM BILGES.
Electrical
Issued 2 June 1993
Resolved
PROVIDE BLANK FOR 115 VOLT ELECTRICAL PANEL IN ENGINE ROOM.
Accommodation/Occupational Safety
Issued 2 June 1993
Resolved
PROVIDE LOCK FOR MARINE SANITATION DEVICE HOLDING TANK OVERBOARD DISCHARGE VALVE.
Engineering
Issued 2 June 1993
Resolved
PROVIDE LAGGING FOR PORT/STBD MAIN DIESEL ENGINE EXHAUSTS.
Electrical
Issued 2 June 1993
Resolved
PROVIDE VENTILATION HOLES FOR PORT/STBD BATTERY BOXES IN ENGINE ROOM.
Documentation
Issued 2 June 1993
Resolved
PROVIDE EVIDENCE OF PARTICIPATION IN A RANDOM DRUG TESTING PROGRAM, AS DESCRIBED IN 46 CFR 16.
Construction/Loadline
Issued 2 June 1993
Resolved
INSTALL BILGE MANIFOLD VALVE IDENTIFICATION PLACARD IN ENGINE ROOM.
Fire Fighting
Issued 2 June 1993
Resolved
ENSURE THAT ALL PORTABLE FIRE EXTINGUISHERS ARE PROFESSIONALLY SERVICED.
Navigation
Issued 2 June 1993
Resolved
PROVIDE CURRENT CHART OF NORMAL AREA OF OPERATION, 1993 TIDE TABLES, AND MEANS OF UPDATING/CORRECTING CHARTS/PUBLICATIONS, SUCH AS LOCAL NOTICES TO MARINERS.
Engineering
Issued 27 May 1992
Resolved
RE-LABEL EMERGENCY FUEL SHUT-OFFS.
Engineering
Issued 27 May 1992
Resolved
PROVE PROPER OPERATION OF STARBOARD ENGINE.
Lifesaving
Issued 27 May 1992
Resolved
CONDUCT MAN OVERBOARD AND FIRE DRILLS UNDERWAY, TO THE SATISFACTION OF A COAST GUARD MARINE INSPECTOR.
Electrical
Issued 7 June 1990
Resolved
PROPERLY SUPPORT WIRING IN ENGINE ROOM WITH METALLIC WIRE SUPPORTS.
Construction/Loadline
Issued 7 June 1990
Resolved
SEAL COLLISION BULKHEAD WHERE A/C PIPING PENETRATES UPPER STARBOARD SIDE.
Construction/Loadline
Issued 26 May 1989
Resolved
CLEAN AND TREAT ROT IN ENGINE ROOM AND LAZARETTE OVERHEAD.
Navigation
Issued 26 May 1989
Resolved
REPAIR/REPLACE STBD RUDDER LOG.
Construction/Loadline
Issued 8 June 1988
Resolved
CAP OVERBOARD DISCHARGE, STARBOARD SIDE FORWARD IN ENGINEROOM.
Documentation
Issued 17 November 1987
Resolved
PROVIDE VESSEL WITH A CURRENT FCC STATION LICENSE IAW 46CFR184.25-1, A COPYOF WHICH SHALL BE SENT TO MSO LA/LB.
Electrical
Issued 10 June 1986
Resolved
DESIGN EMERGENCY LIGHTS TO ENERGIZE UPON LOSS OF MAIN POWER.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.