← All vessels
HAKUNA MATATA
Passenger (Inspected) · Passenger Ship class · Built 1990s · USCG Southeast District (CGD-SE) · Other hulls named HAKUNA MATATA
HAKUNA MATATA is a 1996 passenger vessel (inspected). The Coast Guard has recorded 48 inspections since 1996, most recently in March 2026, along with 113 deficiencies and 1 operational control.
Records from 1996 to 2026. Most recent: inspection, 17 March 2026.
- Built
- 1996
- Last inspected
- 17 March 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 113 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1050979
WDD4772
452821
Flag
UNITED STATES
367765110
Maury page id
psix-452821
Inspections, by type
…with no type recorded1
Years with a record
26 calendar years (1996–2026)
The 48 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)50.0 ft × 26.0 ft × 6.0 ft
Registered tonnagegross 11 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCAT AMERICA, INC. · SARASOTA, FL, UNITED STATES · built 1996
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeNot recorded
Hull configurationTwin Hull
Hailing portPALM BEACH, FL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 24 February 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11 - Simplified, Gross Ton
9 - Simplified, Net Ton
9 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDJ3132MMSI 367765110 · active · compulsorily equipped · granted 13 December 2016, expires 13 December 2026
WDD4772MMSI 367148840 · expired · compulsorily equipped · granted 3 November 2006, cancelled 7 January 2017
WCX3418MMSI not assigned · expired · compulsorily equipped · granted 25 March 1997, cancelled 27 May 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 48
17 March 2026
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8328007
4 March 2026
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8319504
26 February 2025
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8085095
8 March 2024
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7875988
20 February 2024
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7867626
22 February 2023
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7640035
8 February 2022
Drydock Exam · Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7392463
3 November 2021
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7344732
23 February 2021
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7144855
19 February 2020
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6911359
19 February 2020
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6911362
15 March 2019
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6643211
5 April 2018
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6385611
15 March 2018
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6399805
28 February 2017
Simplified Stability Test
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6103629
15 December 2016
COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6058174
20 March 2016
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5853113
16 March 2016
Internal Structural Exam · Plan Review "T" Boat · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5834202
24 March 2014
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4821977
3 March 2014
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4809144
21 February 2012
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4248047
22 December 2011
COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4212554
17 March 2010
Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3697106
23 May 2008
Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3232628
22 May 2008
Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3213381
20 May 2008
Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3211579
29 October 2006
Type not recorded
No type recorded · Station Marathon · USCG Southeast District (CGD-SE) · Activity 2812053
29 August 2006
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2744321
14 March 2006
Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2601453
15 February 2005
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2315043
22 January 2004
Deficiency Check · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1993486
25 November 2002
Hull Examination · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1705453
10 December 2001
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 773061
19 November 2001
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1384923
6 October 2000
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1054851
1 September 2000
Deficiency Check · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1413796
21 August 2000
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1432374
17 April 2000
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 816470
4 February 2000
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1045693
23 January 2000
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 814938
17 December 1999
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 812365
27 August 1999
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1375929
26 March 1999
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 808076
31 August 1998
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1433426
9 June 1998
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1400829
15 May 1997
Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1414851
24 December 1996
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1377899
4 December 1996
Initial Construction-Excluding Oversight · Plan Review "T" Boat
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1398693
Deficiency record · 113
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 20 February 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts, U.S. Coast Pilot. Vessel charts not up-to-date and missing U.S. Coast Pilot.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 8 March 2023
Resolved
FCC Safety Certificate has expired. Provide current certificate. Operations restricted to no more than 1000 feet from shore. 46 CFR 80.401
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 8 March 2023
Resolved
Emergency instructions not on board. Create and post vessel's emergency instructions. 46 CFR 185.510
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 March 2023
Resolved
COI and stability letter not posted. Post both documents at or near operating station. 46 CFR 176.302 & 306
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 8 March 2023
Resolved
Aspirin not provided in first aid kit. Provided current aspirin. 46 CFR 160.041
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 8 December 2021
Resolved
EPIRB HRU is expired. HRU to be replaced with current unit prior to carrying passengers. 46 CFR 185.740(b)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 December 2021
Resolved
1 adult life jacket found to be in non-serviceable condition. Replace life jacket with approved type. Max persons reduced to 52. 46 CFR 180.71
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 8 December 2021
Resolved
Alcohol test strips expired. Provided 3 current alcohol test strips. 46 CFR 16.201
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 December 2021
Resolved
Bottom set of batteries' terminals are not covered. Terminals to be covered. 46 CFR 183.350
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 8 December 2021
Resolved
No aspirin provided in first aid kit. Provided current aspirin as part of first aid kit. 46 CFR 160.041
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 8 December 2021
Resolved
Emergency instructions not posted. Post emergency instructions at of near operating station. 46 CFR 185.510
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 December 2021
Resolved
COI and stability letter not posted. Post both documents at or near operating station. 46 CFR 176.302 & 306
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 March 2021
Resolved
Four adult life jackets found in non-serviceable condition. Replace life jackets with approved type. Total persons reduced to 49. 46 CFR 180.71
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 March 2021
Resolved
Starboard forward and port aft bilge high level visual alarms inoperable. Repair alarms to allow for operator to see alarm when energized. 46 CFR 182.530(c)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 March 2021
Resolved
Batteries not covered. Provide covers or battery boxes to prevent exposure from water. 46 CFR 183.350(b)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 March 2021
Resolved
Battery connections do not have permanent type connectors. Install permanent type connectors at battery terminals.
46 CFR 153.350(d)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 March 2021
Resolved
Label location of port side accomodation space fire extinguisher or move extinguisher to allow for passengers and crew to see extinguisher. 46 CFR 181.520
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 March 2021
Resolved
Life ring retro-reflective tape in non-serviceable condition. Apply new and approved type retro-reflective tape to life ring. 46 CFR 180.70
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 10 March 2021
Resolved
Emergency instructions not posted. Post vessel's emergency instructions at or near operating station. 46 CFR 185.510
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 March 2021
Resolved
COI and stability letter not posted. Post COI and stability letter at or near operating station. 46 CFR 1763.02-306
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 March 2020
Resolved
Life float inoperable. Restricted to daytime only operations. 46 CFR 180.70(d)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 March 2020
Resolved
Seal hole in life ring. 46 CFR 180.70
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 March 2020
Resolved
Separate child and adult life jackets. 46 CFR 180.71
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 21 March 2019
Resolved
Conduct drills. 46 CFR 185.520-524
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 March 2019
Resolved
Replace non-serviceable life jackets. Total person allowed reduced to 42. 46 CFR 180.71
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 March 2019
Resolved
Replace wasted throttle cables on port side outboard engine.
46 CFR 182.200
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 21 March 2019
Resolved
Connect radio to GPS or install a GPS integrated radio.
47 CFR 80.905
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 21 March 2019
Resolved
Program MMSI number into radio. 47 CFR 80.905
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 21 March 2019
Resolved
Install rail courses or equivalent at openings at fantail and bow of vessel. 46 CFR 177.900
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 March 2019
Resolved
Tighten battery cable connections and install permanent type connectors on terminals. 46 CFR 183.350
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 March 2019
Resolved
Life ring life-line to be immediately deployable.
46 CFR 180.175
Documentation › Certificates/Documents › Certificate of Inspection
Issued 5 April 2018
Resolved
Pay user fees prior to credit drydock.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 15 March 2018
Resolved
Provide pre-employment test result for Kristin prior to using as deckhand.
Communications › Alarms/Indicators › Fire Alarm
Issued 15 December 2016
Resolved
Provide 2 UL approved smoke detectors as discussed with CGMI.
Communications › Radio Communications › EPIRB
Issued 15 December 2016
Resolved
Provide new 406 epirb prior to going beyond the shoreline.
Lifesaving › Hand Flares › Not on Board
Issued 15 December 2016
Resolved
Provide 12 approved hand flares.
Communications › Alarms/Indicators › Bilge Alarm
Issued 15 December 2016
Resolved
Prove proper operation of port aft high water alarm.
Navigation › Piloting/Steering › Magnetic Compass
Issued 15 December 2016
Resolved
Provide magnetic compass with light.
Documentation › Certificates/Documents › Stability Letter
Issued 16 March 2016
Resolved
Submit weight change calculations to MSC for stability approval in regards to removing the mast and all of the rigging.
Stability › Watertight Integrity › General
Issued 16 March 2016
Resolved
Repair main deck hatch gaskets on aft two deck hatches.
Engineering › Bilge Water Management System › Pump
Issued 16 March 2016
Resolved
Provide UL approved bilge pumps.
Stability › Unintentional Flooding › General
Issued 16 March 2016
Resolved
Repair STBD hull collision bulkhead.
Stability › Unintentional Flooding › General
Issued 16 March 2016
Resolved
Install metallic caps on engine room through hull valves that are not being used.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 March 2016
Resolved
Use or remove any loose wiring from engine room where the diesel engines have been removed.
Construction/Loadline › Structures › Deck Plating
Issued 21 February 2012
Resolved
Tighten deck frame fasteners and replace missing lock nuts.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 21 February 2012
Resolved
Replace stbd propeller.
Construction/Loadline › Hull › Side Shell
Issued 21 February 2012
Resolved
Repair damaged FRP located port side aft/dove tail.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 22 December 2011
Resolved
Show proof of EAP 1 hour training.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 22 December 2011
Resolved
Install belt guards on both MDE's.
Engineering › Fuel Oil Service System › Hose
Issued 22 December 2011
Resolved
Double hose clamp all fuel lines.
Engineering › Fuel Oil Service System › Filter
Issued 22 December 2011
Resolved
Install filter bowl on port Raccor.
Lifesaving › Lifefloat › Lifeline
Issued 8 April 2010
Resolved
Provide new webing lines for port and stbd lifefloats. Provide retroreflective tape for both lifefloats. Stencil and teather paddles to both lifefloats. Provide painter securing ring for each lifefloat. Patch top of both lifefloats.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 8 April 2010
Resolved
Renew shaft packing on the stbd shaft.
Documentation › Logs/Records › Logbook (official)
Issued 8 April 2010
Resolved
Provide training and EPRIB logs and provide a lifesaving maintenance records.
Fire Fighting › Fire Bucket › Quantity
Issued 8 April 2010
Resolved
Provide 3 2-1/2 gallon fire buckets with lanyards and stencil the fire buckets "fire bucket".
Electrical › Electric Supply System (service) › Battery Installation
Issued 8 April 2010
Resolved
Secure the batteries in the port side engine room.
Engineering › Bilge Water Management System › Hose
Issued 8 April 2010
Resolved
Provide a hose for the portable hand bilge pump.
Navigation › Piloting/Steering › Deviation Table/Graph
Issued 8 April 2010
Resolved
Provide a compass deviation table.
Construction/Loadline › Structures › Superstructure
Issued 17 March 2010
Resolved
Provide a sail rigging report.
Fire Fighting › Fixed Gas Fire Extinguishing System › Control Valve
Issued 17 March 2010
Resolved
Provide a manual actuation from outside the space for each pre-engineered fixed gas fire extinguishing systems for each space protected and a separate means to reset each devise.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 22 May 2008
Resolved
Provide rail courses or mesh screen IAW 46 cfr 177.900. Rail courses to be spaced at not more than 4 inches or mesh screen with no opening more than 4 inches.
Engineering › Bilge Water Management System › Pump
Issued 22 May 2008
Resolved
Provide approved electric submersible bilge pumps.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 22 May 2008
Resolved
Install cargo nets on forward part of vessel between catamaran hulls.
Documentation › Markings/Placards › Lifejacket Placard
Issued 22 May 2008
Resolved
Display and mount life jacket donning placard directly adjacent to stowage location.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 22 May 2008
Resolved
Demonstrate engine room fixed fire fighting activates individual alarm for port and starboard engine room and when system activates it shuts down the affected engine.
Communications › Alarms/Indicators › Bilge Alarm
Issued 22 May 2008
Resolved
Mount bilge alarm at same level as the engine mounts.
Documentation › Markings/Placards › Lifejacket Placard
Issued 22 May 2008
Resolved
Properly label directly adjacent to childs life jackets, CHILDS LIFE JACKETS.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 March 2006
Resolved
Prior to the carriage of passengers, provide a rigging report. O/O never provided a rigging report from dry dock.
Construction/Loadline › Structures › Superstructure
Issued 14 March 2006
Resolved
Prior to the carriage of passengers, reconfigure or repair midship bench supports/deck tie-ins. Reconfigure rigging supports to mitigate future bench/deck seperation. O/O was using a seat for a tie-down for his sail rigging, which in turn, tore the bech up from the deck.
Construction/Loadline › Structures › Superstructure
Issued 14 March 2006
Resolved
Prior to the carriage of passengers, repair STBD rail stanchions. (Last two AFT.) O/O used railing to tie off sail rigging, which in turn tore railing apart.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 14 March 2006
Resolved
Prior to the carriage of passengers, make shaft seals in engine room visible for inspection. O/O had misc. debris all over shaft.
Operations/Management › Drills/Instruction › Not Conducted
Issued 14 March 2006
Resolved
Conduct a complete Certificate Of Inspection.
Communications › Radio Communications
Issued 22 January 2004
Resolved
REPLACE HYDROSTATIC RELEASE ON 406 MHZ EPIRB PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: EPIRB
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 22 January 2004
Resolved
REPAIR PORT ENGINE ROOM EXHAUST HOSE PRIOR TO CARRIAGEOF PASSENGERS. LEGACY COMPONENT DESC: Ventillation
Engineering › Bilge Water Management System
Issued 22 January 2004
Resolved
REPAIR PORT ENGINE ROOM AUTO BILGE SWITCH PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Pump
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 22 January 2004
Resolved
PROVIDE ONE B-II TYPE MARINE FIRE EXTINGUISHER PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Number
Engineering › Fuel Oil Storage/Transfer System
Issued 22 January 2004
Resolved
INSTALL METALLIC PLUGS ON FUEL STRAINERS. LEGACY COMPONENT DESC: Filter/Strainer
Operations/Management › Drills/Instruction
Issued 22 January 2004
Resolved
INITIATE EPIRB TESTING LOG. LEGACY COMPONENT DESC: Epirb
Engineering › Bilge Water Management System
Issued 25 November 2002
Resolved
Repair Lights for high bilge level water alarms.
Lifesaving › Liferaft Equipment
Issued 25 November 2002
Resolved
Label life ring and life float paddles with vessel's name.
Lifesaving › Buoyant Apparatus
Issued 25 November 2002
Resolved
Prior to operating at night, replace battery for life ring light.
Communications › Radio Communications
Issued 25 November 2002
Resolved
Prior to utilizing your Limited Coastwise Route, replace EPIRB battery and hydrostatic release. LEGACY COMPONENT DESC: EPIRB
Stability
Issued 25 November 2002
Resolved
REMOVE PORTABLE BALLAST FROM VESSEL TO REMAIN IN COMPLIANCE WITH VESSEL STABILITY LETTER PRIOR TO CARRIAGE OF PASSENGERS. ANY CHANGE IN VESSEL CONFIGURATION MUST BE SUBMITTED TO AND APPROVED BY USCG MARINE SAFETY CENTER. LEGACY COMPONENT DESC: ballast
Engineering › Fuel Oil Service System
Issued 15 November 2002
Resolved
INSTALL METALLIC FLAME BOWL AND METALLIC TAPERED PLUG ON STARBOARD FUEL STRAINER. LEGACY COMPONENT DESC: Filter
Engineering › Fuel Oil Service System
Issued 15 November 2002
Resolved
INSTALL METALLIC FUEL STRAINER ON PORT MAIN FUEL LINE. LEGACY COMPONENT DESC: Filter
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 15 November 2002
Resolved
REPAIR ENGINE INTAKE AIR VENTS TO PREVENT WATER ENTRY. LEGACY COMPONENT DESC: Piping (air intake)
Construction/Loadline › Hull
Issued 15 November 2002
Resolved
REPAIR AREA OF DELAMINATION IN PORT FOREPEAK. LEGACY COMPONENT DESC: Bottom Plating
Engineering
Issued 19 November 2001
Resolved
REPAIR/REPLACE JACKET WATER TEMP GAUGE ON PORT ENGINE.
Lifesaving
Issued 19 November 2001
Resolved
REPAIR REPLACE HAND LINES ON ONE LIFERING PRIOR TO CARRIAGE OF PASSENGERS.
Fire Fighting
Issued 19 November 2001
Resolved
CONDUCT ANNUAL SERVICE OF PORT ENGINE ROOM FIXED FIREFIGHTING SYSTEM PRIOR TO CARRIAGE OF PASSENGERS.
Fire Fighting
Issued 19 November 2001
Resolved
REPAIR/REPLACE SMOKE DETECTION IN PORT/STBD ENGINE ROOM PRIOR TO CARRIAGE OF PASSENGERS.
Construction/Loadline
Issued 1 September 2000
Resolved
INSTALL POSITIVE CLOSURE DEVICES ON 03 BILGE DISCHARGE LINES.
Construction/Loadline
Issued 21 August 2000
Resolved
INSTALL HIGH LEVEL BILGE ALARMS IN EACH ENGINE ROOM.
Documentation
Issued 21 August 2000
Resolved
PROVIDE PROOF OF ANNUAL USER FEE PAYMENT.
Documentation
Issued 21 August 2000
Resolved
PROVIDE PROPER DOCUMENTATION OF CURRENT CHEMICAL TESTING PROGRAM.
Fire Fighting
Issued 4 February 2000
Resolved
INSTALL APPROVED MANUAL PULL FOR FIXED FIRE FIGHTING SYSTEM.
Engineering
Issued 4 February 2000
Resolved
INSTALL SAE-J FLEX HOSE ON ENGINE INTAKE.
Lifesaving
Issued 27 August 1999
Resolved
PROVIDE AND POST COPY OF EMERGENCY INSTRUCTIONS.
Engineering
Issued 27 August 1999
Resolved
INSTALL WARNING DEVICE FOR LOSS OF COOLING WATER FLOW TO THE ENGINES EXHAUST.
Documentation
Issued 27 August 1999
Resolved
PROVIDE DOCUMENTATION THAT CREW ARE IN DRUG TESTING PROGRAM IN ACCORDANCE WITH 46CFR16.
Fire Fighting
Issued 27 August 1999
Resolved
SUBMIT PLANS FOR AND INSTALL MANUAL RELEASE FOR FIXED FIRE FIGHTING SYSTEM IN PORT AND STBD MACHINERY SPACES.
Documentation
Issued 27 August 1999
Resolved
PROVIDE AND POST COPY OF STABILITY LETTER.
Engineering
Issued 27 August 1999
Resolved
INSTALL DOUBLE HOSE CLAMPS ON ALL FUEL HOSES THROUGH-OUT THE VESSEL.
Fire Fighting
Issued 27 August 1999
Resolved
INSTALL 4 ADDITIONAL SMOKE DETECTORS THAT MEET UL217 THROUGH-OUT VOID SPACES IN THE VESSEL.
Lifesaving
Issued 27 August 1999
Resolved
PROVIDE DOCUMENTED PROOF OF REPLACEMENT DATE FOR HYDROSTATIC RELEASE FOR EPIRB.
Fire Fighting
Issued 26 March 1999
Resolved
PROVE PROPER OPERATION OF FIXED FIRE FIGHTING EXTINGUISHING SYSTEM AT NEXT COAST GUARD INSPECTION.
Unknown
Issued 9 June 1998
Resolved
PROVIDE PROOF OF DRUG TESTING/RANDOM DRUG TESTING IAW 46CFR PART 16._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 9 June 1998
Resolved
INSTALL 2-3' PADDLES IN EACH LIFEFLOAT, LABEL WITH VESSEL'S NAME._x001C_ _x001C_ _x001C_ _x001C_
Fire Fighting
Issued 9 June 1998
Resolved
PROVIDE HAND FIRE/BILGE PUMP._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 9 June 1998
Resolved
PROVIDE 2 ADDITIONAL ADULT TYPE I PFDS. VESSEL MAY ONLY CARRY 50 TOTAL PERSONS UNTIL COMPLETE._x001C_ _x001C_ _x001C_
Fire Fighting
Issued 15 May 1997
Resolved
PROVIDE ONE B-II FIRE EXTINGUISHER.
Documentation
Issued 15 May 1997
Resolved
PROVIDE VALID RADIO TELEPHONY CERTIFICATE. VESSEL'S ROUTE RESTRICTED TO NOTMORE THAN 1000 FEET FROM SHORE.
Documentation
Issued 15 May 1997
Resolved
PROVIDE AND POST EMERGENCY CHECKOFF LIST.