Records from 2016 to 2026. Most recent: inspection, 17 March 2026.
Inspection history · 18
17 March 2026
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8328007
4 March 2026
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8319504
26 February 2025
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8085095
8 March 2024
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7875988
20 February 2024
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7867626
22 February 2023
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7640035
8 February 2022
Drydock Exam · Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7392463
3 November 2021
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7344732
23 February 2021
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7144855
19 February 2020
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6911359
19 February 2020
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6911362
15 March 2019
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6643211
5 April 2018
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6385611
15 March 2018
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6399805
28 February 2017
Simplified Stability Test
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6103629
15 December 2016
COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6058174
20 March 2016
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5853113
16 March 2016
Internal Structural Exam · Plan Review "T" Boat · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5834202
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 20 February 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts, U.S. Coast Pilot. Vessel charts not up-to-date and missing U.S. Coast Pilot.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2024
Resolved 8 March 2024
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 8 March 2023
Resolved
FCC Safety Certificate has expired. Provide current certificate. Operations restricted to no more than 1000 feet from shore. 46 CFR 80.401
Action required: 705 - Other - as specified
Resolved 30 March 2023
Resolution: Current certificate provided.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 8 March 2023
Resolved
Emergency instructions not on board. Create and post vessel's emergency instructions. 46 CFR 185.510
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2023
Resolved 30 March 2023
Resolution: Instructions posted.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 March 2023
Resolved
COI and stability letter not posted. Post both documents at or near operating station. 46 CFR 176.302 & 306
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2023
Resolved 30 March 2023
Resolution: COI and Stability letter posted.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 8 March 2023
Resolved
Aspirin not provided in first aid kit. Provided current aspirin. 46 CFR 160.041
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2023
Resolved 30 March 2023
Resolution: Current aspirin provided.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 8 December 2021
Resolved
EPIRB HRU is expired. HRU to be replaced with current unit prior to carrying passengers. 46 CFR 185.740(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 December 2021
Resolution: HRU replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 December 2021
Resolved
1 adult life jacket found to be in non-serviceable condition. Replace life jacket with approved type. Max persons reduced to 52. 46 CFR 180.71
Action required: 705 - Other - as specified
Resolved 10 January 2022
Resolution: 1 life jacket provided.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 8 December 2021
Resolved
Alcohol test strips expired. Provided 3 current alcohol test strips. 46 CFR 16.201
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 January 2022
Resolution: Test strips provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 December 2021
Resolved
Bottom set of batteries' terminals are not covered. Terminals to be covered. 46 CFR 183.350
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 January 2022
Resolved 8 December 2021
Resolution: Terminals covered.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 8 December 2021
Resolved
No aspirin provided in first aid kit. Provided current aspirin as part of first aid kit. 46 CFR 160.041
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 January 2022
Resolution: Aspirin provided.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 8 December 2021
Resolved
Emergency instructions not posted. Post emergency instructions at of near operating station. 46 CFR 185.510
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 January 2022
Resolution: Instructions posted.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 December 2021
Resolved
COI and stability letter not posted. Post both documents at or near operating station. 46 CFR 176.302 & 306
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 January 2022
Resolution: Documents posted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 March 2021
Resolved
Four adult life jackets found in non-serviceable condition. Replace life jackets with approved type. Total persons reduced to 49. 46 CFR 180.71
Action required: 705 - Other - as specified
Resolved 2 April 2021
Resolution: Life jackets replaced.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 March 2021
Resolved
Starboard forward and port aft bilge high level visual alarms inoperable. Repair alarms to allow for operator to see alarm when energized. 46 CFR 182.530(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 2 April 2021
Resolution: Alarms operate sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 March 2021
Resolved
Batteries not covered. Provide covers or battery boxes to prevent exposure from water. 46 CFR 183.350(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 2 April 2021
Resolution: Batteries covered.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 March 2021
Resolved
Battery connections do not have permanent type connectors. Install permanent type connectors at battery terminals.
46 CFR 153.350(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 2 April 2021
Resolution: Connections sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 March 2021
Resolved
Label location of port side accomodation space fire extinguisher or move extinguisher to allow for passengers and crew to see extinguisher. 46 CFR 181.520
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 2 April 2021
Resolution: Location labeled sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 March 2021
Resolved
Life ring retro-reflective tape in non-serviceable condition. Apply new and approved type retro-reflective tape to life ring. 46 CFR 180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 2 April 2021
Resolution: Approved tape applied sat.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 10 March 2021
Resolved
Emergency instructions not posted. Post vessel's emergency instructions at or near operating station. 46 CFR 185.510
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 2 April 2021
Resolution: Instructions posted.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 March 2021
Resolved
COI and stability letter not posted. Post COI and stability letter at or near operating station. 46 CFR 1763.02-306
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 2 April 2021
Resolution: Documents posted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 March 2020
Resolved
Life float inoperable. Restricted to daytime only operations. 46 CFR 180.70(d)
Action required: 705 - Other - as specified
Resolved 7 May 2020
Resolution: New life-float installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 March 2020
Resolved
Seal hole in life ring. 46 CFR 180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2020
Resolved 10 April 2020
Resolution: Hole sealed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 March 2020
Resolved
Separate child and adult life jackets. 46 CFR 180.71
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2020
Resolved 10 April 2020
Resolution: Life jackets separated.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 21 March 2019
Resolved
Conduct drills. 46 CFR 185.520-524
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2019
Resolution: Conducted drills SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 March 2019
Resolved
Replace non-serviceable life jackets. Total person allowed reduced to 42. 46 CFR 180.71
Action required: 705 - Other - as specified
Due 4 April 2019
Resolved 5 April 2019
Resolution: All life jackets in serviceable condition.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 March 2019
Resolved
Replace wasted throttle cables on port side outboard engine.
46 CFR 182.200
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2019
Resolved 5 April 2019
Resolution: Throttle cables replaced.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 21 March 2019
Resolved
Connect radio to GPS or install a GPS integrated radio.
47 CFR 80.905
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2019
Resolved 5 April 2019
Resolution: Radio connected to GPS SAT.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 21 March 2019
Resolved
Program MMSI number into radio. 47 CFR 80.905
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2019
Resolved 5 April 2019
Resolution: MMSI number programmed in radio.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 21 March 2019
Resolved
Install rail courses or equivalent at openings at fantail and bow of vessel. 46 CFR 177.900
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2019
Resolved 5 April 2019
Resolution: Course equivalent installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 March 2019
Resolved
Tighten battery cable connections and install permanent type connectors on terminals. 46 CFR 183.350
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2019
Resolved 5 April 2019
Resolution: Permanent type connectors installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 March 2019
Resolved
Life ring life-line to be immediately deployable.
46 CFR 180.175
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2019
Resolved 5 April 2019
Resolution: Throw bag installed and made imediately available.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 5 April 2018
Resolved
Pay user fees prior to credit drydock.
Due 18 April 2018
Resolved 16 April 2018
Resolution: Showed proof of payment of user fees.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 15 March 2018
Resolved
Provide pre-employment test result for Kristin prior to using as deckhand.
Due 26 May 2018
Resolved 23 May 2018
Resolution: Provided pre employment test result.
Communications › Alarms/Indicators › Fire Alarm
Issued 15 December 2016
Resolved
Provide 2 UL approved smoke detectors as discussed with CGMI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 December 2016
Resolved 16 December 2016
Resolution: Provided 2 UL smoke detectors.
Communications › Radio Communications › EPIRB
Issued 15 December 2016
Resolved
Provide new 406 epirb prior to going beyond the shoreline.
Due 15 January 2017
Resolved 16 January 2017
Resolution: Provided new epirb.
Lifesaving › Hand Flares › Not on Board
Issued 15 December 2016
Resolved
Provide 12 approved hand flares.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2016
Resolution: Provided approved hand flares.
Communications › Alarms/Indicators › Bilge Alarm
Issued 15 December 2016
Resolved
Prove proper operation of port aft high water alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2016
Resolution: Proved proper operation of bilge alarm.
Navigation › Piloting/Steering › Magnetic Compass
Issued 15 December 2016
Resolved
Provide magnetic compass with light.
Due 16 January 2017
Resolved 16 January 2017
Resolution: Installed compass with light.
Documentation › Certificates/Documents › Stability Letter
Issued 16 March 2016
Resolved
Submit weight change calculations to MSC for stability approval in regards to removing the mast and all of the rigging.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2017
Resolution: Vessel has completed new SST test and sucessfully passed for 49 passengers and 4 crew. total persons allowed is 53.
Stability › Watertight Integrity › General
Issued 16 March 2016
Resolved
Repair main deck hatch gaskets on aft two deck hatches.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 April 2016
Resolution: Owner has replaced the hatch gaskets.
Engineering › Bilge Water Management System › Pump
Issued 16 March 2016
Resolved
Provide UL approved bilge pumps.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 April 2016
Resolution: Owner has installed UL approved bilge pumps.
Stability › Unintentional Flooding › General
Issued 16 March 2016
Resolved
Repair STBD hull collision bulkhead.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 April 2016
Resolution: Vessel has replaced STBD collision bulkhead in kind.
Stability › Unintentional Flooding › General
Issued 16 March 2016
Resolved
Install metallic caps on engine room through hull valves that are not being used.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 April 2016
Resolution: Owner has installed metellic caps.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 March 2016
Resolved
Use or remove any loose wiring from engine room where the diesel engines have been removed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 April 2016
Resolution: Owner has removed all loose wiring.