MAURY USCG vessel records Sign in
← All vessels

TRANSOCEAN AMIRANTE

TRANSOCEAN AMIRANTE is a 1978 mobile offshore drilling unit. The Coast Guard has recorded 28 inspections since 1997, most recently in February 2010, along with 24 deficiencies.

Records from 1997 to 2010. Most recent: inspection, 28 February 2010.

Built
1978
Last inspected
28 February 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8752582 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
HP8666
452970
Flag
PANAMA
—
Maury page id
psix-452970

Inspections, by type

…with no type recorded11
Years with a record 10 calendar years (1997–2010)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it12285 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 28

28 February 2010 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3689043
26 September 2008 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3333032
29 July 2008 COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3282879
9 September 2007 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3053208
28 February 2007 COC-MODU Renew
Type not classified · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2879465
26 October 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2808306
2 October 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2791806
18 September 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2781137
9 September 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2781094
9 September 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2791724
5 May 2006 COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2641303
5 June 2005 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2390086
26 May 2005 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2384929
19 May 2005 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2382984
28 February 2005 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2301409
16 February 2005 COC-MODU Renew
Type not classified · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2292482
28 January 2002 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1489293
14 September 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 120181
25 August 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073140
13 May 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1064154
26 March 2001 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1066447
24 February 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1058541
13 February 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1466743
29 October 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1361195
11 June 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 808491
30 October 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1388770
23 July 1997 Letter of Compliance (Initial/Renewal)
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1467018
1 July 1997 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1113793

Deficiency record · 24

Engineering › Bilge Water Management System › Pump
Issued 17 February 2005 Resolved
Prior to departing the Port of Mobile, correct all outstanding "No Sail" conditions of class and provide class report to the attending marine inspector.
Action required: 705 - Other - as specified
Resolved 28 March 2005
Resolution: Examined DNV class report clearing "No Sail" conditions of class.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 February 2005 Resolved
Properly focus all four obstruction lights.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 February 2005
Resolved 17 February 2005
Resolution: All four obstruction lights were focused.
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 17 February 2005 Resolved
Prove proper operation of fog horn.
Action required: 705 - Other - as specified
Due 17 February 2005
Resolved 17 February 2005
Resolution: The fog horn was tested satisfactorily.
Deck/Cargo › Ballast › Valves
Issued 16 February 2005 Resolved
Prior to departing the Port of Mobile, prove proper operation of the ballast control indicator panel for the trim tanks.
Action required: 705 - Other - as specified
Resolved 28 February 2005
Resolution: Witnessed proper operation of all trim tank indicators.
Lifesaving › Launching Appliances › Winch Brake
Issued 16 February 2005 Resolved
Properly align brake assembly and prove proper operation of brake for lifeboat No. 4.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2005
Resolved 17 February 2005
Resolution: Witnessed operation of brake and examined assembly.
Construction/Loadline › Structures › Air Pipe
Issued 16 February 2005 Resolved
Provide positive closure on vent closure to potable room.
Action required: 705 - Other - as specified
Due 17 February 2005
Resolved 17 February 2005
Resolution: The vent had a closure attached.
Lifesaving
Issued 13 February 2001 Resolved
Lifeboat #2 to be placed out of service, station bill updated, until repaired and tested.
Condition: Unknown
Due 9 April 2001
Resolved 28 January 2002
Resolution: CLEARED AT COC INSP.
Lifesaving
Issued 13 February 2001 Resolved
Provide evidence of suitability of drillers A/C & heating unit for hazardous location.
Condition: Unknown
Due 9 April 2001
Resolved 28 January 2002
Resolution: CLEARED AT COC INSP
Electrical
Issued 29 October 1999 Resolved
PROVIDE GENERAL ALARM LIGHT IN SHAKER HOUSE (DUE TO HIGH NOISE LEVEL).
Condition: Unknown
Due 29 November 1999
Resolved 12 January 2000
Lifesaving
Issued 29 October 1999 Resolved
SECURE ALL PFD BOXES.
Condition: Unknown
Due 29 November 1999
Resolved 12 January 2000
Fire Fighting
Issued 29 October 1999 Resolved
PROVIDE INSTRUCTIONS FOR CO2 ACTUATION.
Condition: Unknown
Due 29 November 1999
Resolved 12 January 2000
Electrical
Issued 29 October 1999 Resolved
PROVIDE EVIDENCE OF SUITABILITY OF GENERAL ALARM SWITCH IN DRILLERS BOOTH FOR HAZARDOUS (CLASSIFIED) LOCATIONS.
Condition: Unknown
Due 29 November 1999
Resolved 12 January 2000
Fire Fighting
Issued 29 October 1999 Resolved
CLARIFY SEPARATION OF CO2 CONTROLS WITH CLASS/FLAG JUSTIFICATION.
Condition: Unknown
Due 29 November 1999
Resolved 12 January 2000
Fire Fighting
Issued 29 October 1999 Resolved
PROVIDE CO2 FOR HELIDECK PER MODU CODE 9.11.2.3.
Condition: Unknown
Due 29 November 1999
Resolved 3 November 1999
Documentation
Issued 30 October 1998 Resolved
Provide full term IOPP Certificate.
Condition: Unknown
Due 3 November 1999
Resolved 3 November 1999
Electrical
Issued 30 October 1998 Resolved
Install purge alarm on bulk system control panel in mud pit room.
Condition: Unknown
Due 20 November 1998
Resolved 5 April 1999
Fire Fighting
Issued 30 October 1998 Resolved
Remove vent located outside sack hatch.
Condition: Unknown
Due 20 November 1998
Resolved 5 April 1999
Construction/Loadline
Issued 30 October 1998 Resolved
Complete repair of starboard ballast tank guages.
Condition: Unknown
Due 31 December 1998
Resolved 5 April 1999
Documentation
Issued 30 October 1998 Resolved
Provide full term MODU Code Safety Certificate.
Condition: Unknown
Due 3 November 1999
Resolved 3 November 1999
Documentation
Issued 30 October 1998 Resolved
Provide full term Loadline Certificate.
Condition: Unknown
Due 3 November 1999
Resolved 3 November 1999
Fire Fighting
Issued 30 October 1998 Resolved
Install self-closing device on door separating division 2, hazardous location and break room.
Condition: Unknown
Due 20 November 1998
Resolved 5 April 1999
Documentation
Issued 30 October 1998 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 7 April 1999
Resolved 5 April 1999
Construction/Loadline
Issued 30 October 1998 Resolved
Provide on board vessel construction portfolio.
Condition: Unknown
Due 31 December 1998
Resolved 5 April 1999
Construction/Loadline
Issued 30 October 1998 Resolved
Install hydraulic hand pumps for hydraulic doors (aft port and starboard) in pump room.
Condition: Unknown
Due 31 December 1998
Resolved 5 April 1999

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.