Records from 1985 to 1992. Most recent: inspection, 17 April 1992.
Documentation record
Registered dimensions (L × B × D)41.8 ft × 12.5 ft × 6.5 ft
Registered tonnagegross 30 / net 22
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHUNTER BOAT WORKS · SUISUN CITY, CA, UNITED STATES · built 1966
Hull materialWood
PropulsionGasoline Engine
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN FRANCISCO, CA
Trade endorsementsRecreational
DocumentationValid · issued 22 September 2022 · expires 31 October 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it30 - Regulatory (Subpart C or D), Gross Ton
22 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 17
17 April 1992
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1269178
27 February 1992
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 956030
29 October 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1004340
19 August 1991
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1250827
7 December 1990
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1231838
14 November 1990
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1244927
30 August 1990
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 928886
7 August 1989
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1205466
11 April 1989
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1204089
24 August 1988
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1043011
13 July 1988
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1339323
10 August 1987
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1338396
5 March 1987
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1007356
7 August 1986
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1003180
17 July 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1301256
3 June 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 984385
5 March 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 977925
Engineering
Issued 19 August 1991
Resolved
INSTALL GUARDS ON BOTH MAIN ENGINE PULLEY & BELT ASSEMBLIES._x001C_ _x001C_
Condition: Unknown
Due 19 August 1991
Resolved 19 August 1991
Navigation
Issued 19 August 1991
Resolved
DRILL & PIN OR DOUBLE NUT AS APPROPRIATE ALL STEERING LINKAGE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 1991
Resolved 19 August 1991
Construction/Loadline
Issued 19 August 1991
Resolved
PROPERLY SEAL OFF THROUGH HULL FITTINGS PORT SIDE AFT IN E/R AT DRY DOCK._x001C_
Condition: Unknown
Due 19 August 1991
Resolved 19 August 1991
Documentation
Issued 19 August 1991
Resolved
SHOW PROPER DOCUMENTATION OF DRUG TESTING PROGRAM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 1991
Resolved 19 August 1991
Engineering
Issued 19 August 1991
Resolved
PROPERLY INSTALL OUTBOARD AFT ENGINE MOUNT ON PORT MAIN ENGINE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 1991
Resolved 19 August 1991
Lifesaving
Issued 19 August 1991
Resolved
SEPERATE AND MARK MORE CLEARLY THE LOCATION OF THE CHIL LIFE PRESERVERS.
Condition: Unknown
Due 19 August 1991
Resolved 19 August 1991
Accommodation/Occupational Safety
Issued 19 August 1991
Resolved
PROPERLY SECURE COFFEE POT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 1991
Resolved 19 August 1991
Construction/Loadline
Issued 30 August 1990
Resolved
PERMANENTLY REPAIR 9 INCH DENT AND CRACK IN HULL, AFT, STBD SIDE, 2 FT FROM STERN, AND 23 INCHES ABOVE WATERLINE. REPAIR TO BE MADE BY REPLACING TWO PLANKS DAMAGED.
Condition: Unknown
Due 30 August 1990
Resolved 30 August 1990
Engineering
Issued 30 August 1990
Resolved
REPLACE ALL FLAME SCREENS WITH PROPER 30X30 MESH.
Condition: Unknown
Due 30 August 1990
Resolved 30 August 1990
Navigation
Issued 30 August 1990
Resolved
PROVIDE COMPASS DEVIATION CARD.
Condition: Unknown
Due 30 August 1990
Resolved 30 August 1990
Construction/Loadline
Issued 30 August 1990
Resolved
REPLACE TWO FRAMES, PORT SIDE, AT KEEL, BENEATH FWD. HEAD AND COMPANIONWAY. FRAMES ARE ROTTEN. ROT HAS NOT BEEN ARRESTED
Condition: Unknown
Due 30 August 1990
Resolved 30 August 1990
Navigation
Issued 30 August 1990
Resolved
REPAIR ANCHOR LIGHT.
Condition: Unknown
Due 30 August 1990
Resolved 30 August 1990
Documentation
Issued 30 August 1990
Resolved
PROVIDE VALID FCC LICENSE.
Condition: Unknown
Due 30 August 1990
Resolved 30 August 1990
Engineering
Issued 13 July 1988
Resolved
INSTALL FUEL VENT SCREENS.
Condition: Unknown
Due 13 July 1988
Resolved 13 July 1988
Lifesaving
Issued 13 July 1988
Resolved
STENCIL CAPACITY OF LIFEFLOAT.
Condition: Unknown
Due 13 July 1988
Resolved 13 July 1988
Electrical
Issued 13 July 1988
Resolved
RESPLICE ANCHOR WINDLESS WIRES.
Condition: Unknown
Due 13 July 1988
Resolved 13 July 1988
Electrical
Issued 13 July 1988
Resolved
INSTALL COVER BOX ON WIRE TERMINAL.
Condition: Unknown
Due 13 July 1988
Resolved 13 July 1988
Electrical
Issued 13 July 1988
Resolved
LINE BATTERY BOX OF MAIN ENGINES.
Condition: Unknown
Due 13 July 1988
Resolved 13 July 1988
Engineering
Issued 13 July 1988
Resolved
REPAIR AMP & TEMP. GAUGES FOR STBD. MAIN ENGINE.
Condition: Unknown
Due 13 July 1988
Resolved 13 July 1988
Lifesaving
Issued 10 August 1987
Resolved
REPLACE ALL PENDANTS ON BOUYANT APPARATUS
Condition: Unknown
Due 10 August 1987
Resolved 10 August 1987
Lifesaving
Issued 10 August 1987
Resolved
PROVIDE ONE ADULT PFD.
Condition: Unknown
Due 10 August 1987
Resolved 10 August 1987
Unknown
Issued 3 June 1985
Resolved
CONDUCT A STABILITY TEST OR REQUEST AN EXEMPTION.
Condition: Unknown
Due 3 June 1985
Resolved 3 June 1985