Records from 2003 to 2026. Most recent: inspection, 27 May 2026.
Inspection history · 21
27 May 2026
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8368820
31 March 2025
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8102768
4 February 2025
Internal Structural Exam · COI Inspection · Examination of Repairs · Construction Oversight · Deficiency Check · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8090173
7 May 2024
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7908078
31 July 2023
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7757235
9 February 2023
Deficiency Check · Examination of Repairs · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7633814
1 February 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7629524
23 February 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7401032
11 February 2021
DAPI Audit · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7139351
12 January 2021
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7123099
25 July 2020
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7017178
24 June 2020
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6991608
5 February 2020
COI Inspection · Internal Structural Exam · DAPI Audit · Administrative Inspection · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6904089
10 July 2019
Annual Inspection · DAPI Audit · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6746215
16 April 2019
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6663553
10 May 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6415174
21 September 2017
Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6294347
11 July 2017
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6325539
5 July 2017
DAPI Audit · Annual Inspection · Deficiency Check · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6341702
17 January 2017
Examination of Repairs · Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6107838
25 May 2016
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5882114
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 May 2026
Resolved
Replace raw water exhaust line on the Port side engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 June 2026
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 May 2026
Resolved
FWD railing needs missing hardware replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 June 2026
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 May 2026
Resolved
Replace 2 missing fire buckets.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 June 2026
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 27 May 2026
Resolved
Renew solas tape on life ring.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 June 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 February 2025
Resolved
Life jacket donning placard needs to be posted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2025
Resolved 28 April 2025
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 4 February 2025
Resolved
Vessel needs to have Emergency Instruction placard posted with Manover board, Fire and Heavy weather instructions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2025
Resolved 28 April 2025
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 4 February 2025
Resolved
Drills need to be conducted before vessel can come out of laid up status.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2025
Resolved 28 April 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 May 2024
Resolved
Vessel's COI has an anniversary date of 2/2 with expiration of 2/6/2026. Vessel is required to have an annual inspection conducted within 90 days before or 90 days after anniversary date. Last day of the 90 window was May 6st 2024 to have annual inspection completed. Vessel failed to have annual inspection completed within the 6 month window. Vessel must have inspection completed prior to carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2024
Resolved 28 April 2025
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 February 2023
Resolved
Pre-Engineered fixed gas fire extinguishing system was last serviced in Jan 2021. Fire extinguishers/systems must be serviced annually. Fireboy system must be serviced and cleared prior to carrying passengers to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2023
Resolution: Monroe County Fire & Equipment installed new fireboy system and tested SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 February 2023
Resolved
Oil temp gauge was missing. Main RPM gauge was showing rpm's but could not read the oil psi and water temp. Must replace missing oil pressure gauge and or make repairs to the main rpm gauge that can read oil and water temps.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2023
Resolved 10 February 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 February 2023
Resolved
Port main diesel engine was missing the engine guard. Must replace missing guard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2023
Resolved 6 April 2023
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 9 February 2023
Resolved
Unable to conduct drills due to weather/small craft advisory. Must schedule drills sometime in the next 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2023
Resolved 6 April 2023
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 23 February 2022
Resolved
Fixed gas system (fireboy) will shut the MDE's down, but will not allow restart with the overide. Make repairs and test with the satisfaction of attending CG Marine Inspector.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2022
Resolved 3 March 2022
Resolution: Replaced switch, tested SAT
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 23 February 2022
Resolved
STBD MDE ventilation cover will not latch shut. Make repairs to the broken latch so that the cover will stay closed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2022
Resolved 3 March 2022
Resolution: Installed new latch
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 23 February 2022
Resolved
Both life floats are faded/worn and black. Must repaint both life floats and re label with passenger count and vessels name.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2022
Resolved 13 April 2022
Resolution: Received pictures of life float repainted and labeled correctly
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 23 February 2022
Resolved
Front window in cabin is cracked/broken. Must replace window.
46 CFR 177.1010
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2022
Resolved 24 March 2022
Resolution: Replaced window
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 5 February 2020
Resolved
Engine room bilge pump is inoperable. Repair/renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 February 2020
Resolution: Engine room bilge pump was renewed with a new float switch.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 5 February 2020
Resolved
High level alarm in Lazerette is inoperable. Repair/renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 February 2020
Resolution: High level alarm was renewed with a new float switch.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 February 2020
Resolved
Stern light is extinguished, Repair/renew. Prior to night operations.
Action required: 705 - Other - as specified
Resolved 16 February 2020
Resolution: Stern light was renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 February 2020
Resolved
6 adult PFDs are have broken clips and need new reflective material. Repair/Renew. Prior to carrying more than 30 passengers.
Action required: 705 - Other - as specified
Resolved 10 February 2020
Resolution: 6 PFD’s purchased and renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 February 2020
Resolved
Painter line for the life float is wasted and must be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 February 2020
Resolution: Painter line for life float was renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 February 2020
Resolved
Second Life float is required to be attached to the vessel or linked to the first life float. The painter/lanyard is missing. Provide.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 February 2020
Resolution: Second life float was linked to the first with proper size and length of lanyard/tether.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 10 July 2019
Resolved
Life float strobe lanyard wasted on both life floats. Replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 July 2019
Resolution: Both Life float strobe lanyards were replaced and allsat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 10 July 2019
Resolved
Retro tape on life floats are wasted. Replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 July 2019
Resolution: Retro tape on life floats were replaced and allsat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 July 2019
Resolved
Contents of first aid kit were expired. Replace contents or purchase new.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 July 2019
Resolution: Expired contents were purchased and replaced.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 10 July 2019
Resolved
Navigation chart out of date. Update chart card or provide up-to-date charts.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 July 2019
Resolution: An updated chart was purchased.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 10 July 2019
Resolved
No audible alarm on fire boy system. Repair/Replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 July 2019
Resolution: Fireboy teck corrected audible alarm malfunction.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 July 2019
Resolved
All PFD’s need repairs or replacement.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 July 2019
Resolution: PFD's have been repaired or replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 July 2019
Resolved
FWD center window is broken. Replace window or glass.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 July 2019
Resolution: FWD center window was replaced and allsat.
Lifesaving › Lifefloat › Painter
Issued 10 May 2018
Resolved
Painter was not attached to each individual life float as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2018
Resolved 11 May 2018
Resolution: Painter attached to each lifefloat
Documentation › Certificates/Documents › FCC SSL
Issued 10 May 2018
Resolved
Vessel did not have valid ship station license
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2018
Resolved 11 May 2018
Resolution: Owner provided in SSL
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 5 July 2017
Resolved
Aduible alarm is inoperable. Renew/repair
Action required: 705 - Other - as specified
Due 15 July 2017
Resolved 22 August 2017
Resolution: New alarm was installed and tested all sat.
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 July 2017
Resolved
Vessel has no high level alarm in the aft compartment. This space has a rudder penetration and must have a high level alarm.
Action required: 705 - Other - as specified
Due 15 July 2017
Resolved 5 July 2017
Resolution: Alarm was installed and tested all sat.
Lifesaving › Lifebuoys › Serviceable
Issued 5 July 2017
Resolved
Life ring has holes and cracks and must be renewed.
Action required: 705 - Other - as specified
Due 15 July 2017
Resolved 5 July 2017
Resolution: New life ring was marked and placed into service.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 5 July 2017
Resolved
Life jacket storage must be marked with size and number.
Action required: 705 - Other - as specified
Due 15 July 2017
Resolved 22 August 2017
Resolution: Storage was marked.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 July 2017
Resolved
First aid kit is missing contents. Renew kit or replace missing contents
Action required: 705 - Other - as specified
Due 25 July 2017
Resolved 22 August 2017
Resolution: New first aid kit was provided.
Documentation › Logs/Records › Logbook (official)
Issued 5 July 2017
Resolved
Logs for survival craft maintainance and drills is not being properly kept. Provide new logs and maintain per 46CFR185.
Action required: 705 - Other - as specified
Due 15 July 2017
Resolved 22 August 2017
Resolution: New logs have been created and are being utilized.