DAIWA PACIFIC

DAIWA PACIFIC is a 1966 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 2016, most recently in August 2026, along with 36 deficiencies — 1 with no resolution recorded — and 5 casualty investigations between 2004 and 2012.

Records from 2004 to 2026. Most recent: inspection, 3 August 2026.

Built
1966
Last inspected
3 August 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 August 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WTC9421
Flag
UNITED STATES
Maury page id
psix-45313

Documentation record

Registered dimensions (L × B × D)55.0 ft × 17.9 ft × 6.8 ft
Registered tonnagegross 49 / net 33
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEAWAY BOAT CO · LONG BEACH, CA, UNITED STATES · built 1966
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 4 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it49 - Regulatory (Subpart C or D), Gross Ton
33 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

23 inspections, each with its date, unit and type; 36 deficiencies with the resolution recorded against each; 5 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 23

3 August 2026 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8453710
9 July 2025 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8178375
30 April 2025 Damage Survey · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8124157
7 January 2025 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8059415
19 November 2024 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8037025
7 October 2024 In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8015823
21 May 2024 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7916759
21 June 2023 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7719936
21 June 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7854019
14 November 2022 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7594234
2 May 2022 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7439570
10 March 2022 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7540850
12 April 2021 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7173472
5 April 2021 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7169158
5 May 2020 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6950575
23 September 2019 In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6819307
7 May 2019 DAPI Audit · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6678671
3 April 2019 Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6655018
30 April 2018 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6402417
4 May 2017 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6131444
27 March 2017 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6112187
9 August 2016 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5967325
4 May 2016 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5868795

Deficiency record · 36

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 August 2026 Resolved
A pre-engineered fixed gas fire extinguishing system must: automatically shut down all engines that draw intake air from within the protected space. Fireboy override switch did not function correctly. Correct issue and notify local OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2026
Resolved 19 August 2026
Resolution: MI attended vessel to conduct test. All SAT.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 3 August 2026 Resolved
All vessels with overnight accommodations must be equipped with a general alarm system. The public address system required by § 184.610 of this chapter may be used to sound the general alarm signal. No PA system in berthing area. Install PA or general alarm in berthing area.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2026
Resolved 19 August 2026
Resolution: MI attended vessel to conduct test. All SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 August 2026 Resolved
The OCMI may require the vessel to get underway. Get underway in presence of marine inspector to conduct drills. Conduct drills in presence of MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2026
Resolved 19 August 2026
Resolution: MI attended vessel to conduct drills. All SAT.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 August 2026 Resolved
The owner, charterer, master, or managing operator of a vessel carrying overnight passengers shall have a suitable number of watchmen patrol throughout the vessel during the nighttime, whether or not the vessel is underway, to guard against, and give alarm in case of, a fire, man overboard, or other dangerous situation. Vessel watchman system was not tested, test watchman system during drills.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2026
Resolved 19 August 2026
Resolution: MI attended vessel to conduct test. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 3 August 2026 No resolution recorded
Vessel's man overboard ladder was found to be 2 feet short of water line and not ridged. Provide vessel with a ridged metal ladder that fits vessel railings, and is rated to carry the weight of a crew member and a helpless victim.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2026
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 9 July 2025 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Forepeak bilge alarm light and audible alarm are not operational.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2025
Resolution: Received video of alarm and light functioning properly. All SAT.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 9 July 2025 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2025
Resolved 11 July 2025
Resolution: Received photo of new publications. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 9 July 2025 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel EPIRB registration was expired and new owners name needs to replace old owner. Notify local OCMI once updated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2025
Resolved 10 July 2025
Resolution: Received photo of new EPIRB registration. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 July 2025 Resolved
Child size life jackets equal to 10% of the number of persons permitted on board must be provided. Vessel needs to provide required number of child size life jackets. Notify local OCMI once completed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2025
Resolved 11 July 2025
Resolution: Received photo of new lifejacket. All SAT.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 7 January 2025 Resolved
Excavate and repair small area of rot found in forepeak, stbd side longitudinal stringer at collision bulkhead.
Action required: 705 - Other - as specified
Resolved 12 May 2025
Resolution: Area of concern was excavated and repaired with graving piece and epoxy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 October 2024 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Starboard exhaust piping has pinhole where daylight can be seen at transom. Make repairs to exhaust piping. 46 CFR 182.100
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 October 2024
Resolution: Weld completed on starboard exhaust. All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 7 October 2024 Resolved
At each inspection of a vessel, the owner or managing operator shall be prepared to conduct tests including the following: Inspection and operation of through hull fittings and sea valves. Sea valves located in laz port side above the waterline was removed and through hull was capped using plastic bag with zip tie. Install proper cap/plug on through hull. 46 CFR 176.802(a)(2)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 October 2024
Resolution: Through hull capped.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 7 October 2024 Resolved
The construction and arrangement of a vessel must allow the safe operations of the vessel in accordance with the terms of the COI giving consideration to provisions for a seaworthy hull. Port exhaust wooden piece holding exhaust flange rotted away. Remove rotted wood and make repairs as necessary. 46 CFR 177.100
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 October 2024
Resolution: No repairs necessary. Rott removed, flange wtill held in place.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 June 2023 Resolved
Provide vessel with an interlock device that prevents vessel generator and shore power from being energized at the same time.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2023
Resolved 22 June 2023
Resolution: Vessel rep installed an operable interlock device.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 21 June 2023 Resolved
Repair minor fuel leak on the vessel's generator.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 June 2023
Resolution: New component was replaced on fuel manifold and found to be free of leaks.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 21 June 2023 Resolved
Vessel was found with 02 fire buckets, provide vessel with an additional fire bucket.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 June 2023
Resolution: An additional fire bucket was provided.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 21 June 2023 Resolved
The foothold for crew to access the cabin top was found to be inadequate. Provide larger sized footholds for crew to access the cabin top.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2023
Resolved 22 June 2023
Resolution: New / larger footholds were installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 June 2023 Resolved
As stated in letter dated March 22, 2024, vessel must comply with Fire Safety of Small Passenger Vessels Interim Final Rule requirements by the next scheduled dry dock or 01JAN2026, whichever comes first. Vessel does not meet requirements and is restricted from carrying overnight passengers in accommodation spaces. National Defense Authorization Act for Fiscal Year 2024 (H.R. 2670), Section 3531(b)
Action required: 705 - Other - as specified
Resolved 25 June 2025
Resolution: Ran egress drills. All SAT
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 May 2022 Resolved
Electrical junction boxes and distribution panel in space fwd of pilothouse found to be missing protective covers. Install covers to prevent persons and vessel from electrical hazards.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2022
Resolved 3 May 2022
Resolution: POC provided protective covers for electrical hazards noted.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 May 2022 Resolved
Three five gallon fire buckets missing 2.5 gallon water mark with holes above waterline.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2022
Resolved 3 May 2022
Resolution: POC Drilled holes to accomodate 2.5 gallon limit.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 2 May 2022 Resolved
Three inch PVC piping not properly supported; broken strap. Repair.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2022
Resolved 3 May 2022
Resolution: POC installed support for identified PVC piping.
07 - Fire Safety › N/A - No Subsystem › Emergency Escape Breathing Device and disposition
Issued 2 May 2022 Resolved
Emergency escape placard missing on both port and STBD exterior accesses.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2022
Resolved 3 May 2022
Resolution: POC installed emergency escape labeling on exterior access.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 2 May 2022 Resolved
Port Main diesel engine forward belt drive unit missing guard. Install machinery guard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2022
Resolved 3 May 2022
Resolution: POC installed guard for port main engine.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 5 April 2021 Resolved
VESSELS PRE ENGINEERED FIRE EXTINGUISHING SYSTEM (FIREBOY) OVERRIDE SWITCH IS FAULTY AND NOT OPERATING AS INTENDED / DESIGNED. ENGINES COULD RESTART WITHOUT BEING MANUALLY OVERRIDDEN AS PER MANUFACTURER'S INSTRUCTIONS. HAVE SERVICED TO ENSURE PROPER OPERATION OF OVERRIDE SWITCH WITHIN 30 DAYS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2021
Resolved 3 May 2021
Resolution: Fully operational
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 5 April 2021 Resolved
VESSEL HAS NO RAILING AT FORWARD AREA OF BOW. AN EQUIVALENT LEVEL OF PROTECTION OR RAILING SHALL BE INSTALLED WITHIN 30 DAYS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2021
Resolved 3 May 2021
Resolution: Chain installed with signage
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 May 2020 Resolved
Observed port running nav light not operational. Must fix to the satisfaction of the CG Marine Inspector.
Action required: 10 - Deficiency Rectified
Due 12 May 2020
Resolved 5 May 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 May 2020 Resolved
Observed lube oil leaking from primary filter on port main engine. Must fix to the satisfaction of the CG Marine Inspector.
Action required: 10 - Deficiency Rectified
Due 12 May 2020
Resolved 5 May 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 September 2019 Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, and over current protection.
Action required: 705 - Other - as specified
Due 24 December 2019
Resolved 24 January 2020
Resolution: Plans submitted to Inspections for review-[name withheld]
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 September 2019 Resolved
All escape hatches and emergency exits used as means of escape must be marked on both sides in clearly legible letters that says "EMERGENCY EXIT, KEEP CLEAR". Emergency exit hatch from accommodation space was not marked on the top side in the galley. Mark emergency escape hatch with proper marking on both sides.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 October 2019
Resolved 14 January 2020
Resolution: Escape hatch marked on both sides.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 September 2019 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, and vessel from electrical hazards. Vessel shore tie cable was chafed at entrance to engine room. Repair or replace chafed section of shore tie cable.
Action required: 705 - Other - as specified
Due 24 December 2019
Resolved 12 February 2020
Resolution: Shore power cable replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 May 2019 Resolved
Provide new 60ft line for ring buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2019
Resolved 9 May 2019
Resolution: New line for buoy installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 May 2019 Resolved
Secure wash down pump center/starboard engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2019
Resolved 7 May 2019
Resolution: Pump secured.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 May 2019 Resolved
Provide markings for all life jacket storage.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2019
Resolved 7 May 2019
Resolution: Marking provided.
Construction/Loadline › Hull › Hull Plating
Issued 9 August 2016 Resolved
Provide detailed written plan for repairs to damaged hull section of the starboard bow. (for approval)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 August 2016
Resolution: Rcvd plan and discussed with boatwright. All sat
Construction/Loadline › Hull › Hull Plating
Issued 9 August 2016 Resolved
Crop and renew damaged section of the starboard bow hull plating in accordance with the approved plan. (permanent repairs)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 August 2016
Resolution: Inspected final repairs; all satisfactory
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 4 May 2016 Resolved
Provide 08 adult sized life jackets(vessel is restricted to 36 persons while operating on a limited coastwise route)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2016

Casualty record · 5

31 January 2004Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 1998786
31 January 2004Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 1998901
17 August 2008Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 4811209
18 October 2008Routine · role: Involved in a Marine Casualty · activity 3360112
30 September 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4493439
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.