Records from 1982 to 1996. Most recent: inspection, 10 October 1996.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 20
10 October 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 842775
16 June 1995
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1404040
15 August 1994
COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1463821
8 October 1992
Hull Examination · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1471646
6 September 1991
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 942909
5 September 1990
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 928849
23 February 1990
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 929049
12 January 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1231492
2 January 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 904242
21 December 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1221925
9 November 1989
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1212203
20 May 1989
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1039381
10 March 1989
Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1208771
10 November 1988
Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 894750
5 October 1988
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1196612
12 September 1988
Hull Examination · COI Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1350129
17 June 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 992362
29 May 1985
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 983698
25 May 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1281237
23 August 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 963803
Construction/Loadline
Issued 8 October 1992
Resolved
MAKE PROPER PERMANENT INSERT TO MAIN DECK IN WAY OF AFT WING TANKS. MAINTAIN TEMPORARY DOUBLER PLATE UNTIL REPAIRS ARE MADE.
Condition: Unknown
Due 8 October 1992
Resolved 8 October 1992
Construction/Loadline
Issued 9 November 1989
Resolved
REMOVE ALL TRIP HAZARDS, DANGEROUSLY PLACED CABLE AND WIRING, AND CLEAN SLIPPERY, OILY FILM FROM FLOOR OF MACHINERY SPACE.
Condition: Unknown
Due 9 November 1989
Resolved 9 November 1989
Construction/Loadline
Issued 9 November 1989
Resolved
MAKE NECESSARY REPAIRS TO ALL BALLAST TANK DECK VENTS TO ALLOW FREE MOVEMENT OF HIGH WATER PLUGS TO COMPLY WITH 46 CFR 56.50-85(A)6(II).
Condition: Unknown
Due 9 November 1989
Resolved 9 November 1989
Construction/Loadline
Issued 9 November 1989
Resolved
REWELD THE CRACKED WELD AT THE BASE OF THE "D6" VOID VENT.
Condition: Unknown
Due 9 November 1989
Resolved 9 November 1989
Fire Fighting
Issued 9 November 1989
Resolved
PROVIDE ON BOARD IN MACHINERY SPACE THREE (3) B-II FIRE EXTINGISHERS PRIOR TO OPERATION OF BARGE MACHINERY TO COMPLY WITH 46 CFR 95.05-15.
Condition: Unknown
Due 9 November 1989
Resolved 9 November 1989
Deck/Cargo
Issued 9 November 1989
Resolved
INSTALL PERSONNEL PROTECTIVE GUARDS ON ALL EXPOSED, MOVING MACHINERY PRIOR TO OPERATING BARGE MACHINERY TO COMPLY WITH 46 CFR 92.25-15(A).
Condition: Unknown
Due 9 November 1989
Resolved 9 November 1989
Electrical
Issued 9 November 1989
Resolved
PROVE PROPER OPERATION OF EMERGENCY LIGHTING SYSTEM IN BELOW DECK MACHINERYSPACE TO COMPLY WITH 46 CFR 112.01-10.
Condition: Unknown
Due 9 November 1989
Resolved 9 November 1989
Deck/Cargo
Issued 9 November 1989
Resolved
PROVE PROPER OPERATION OF THE RELIEF VALVE ON THE SERVICE AIR RECEIVER LOCATED IN THE MACHINERY SPACE TO COMPLY WITH 46 CFR 91.25-10(A).
Condition: Unknown
Due 9 November 1989
Resolved 9 November 1989
Construction/Loadline
Issued 9 November 1989
Resolved
LOCATE, MARK AND PROVIDE A 30X30 MESH FLAME SCREEN ON THE BALLAST SYSTEM FUEL OIL TANK VENT TO COMPLY WITH 46 CFR 56.50-85(A)(7).
Condition: Unknown
Due 9 November 1989
Resolved 9 November 1989
Documentation
Issued 10 November 1988
Resolved
PRIOR TO EMBARKING ON AN INTERNATIONAL VOYAGE MAKE SUBJECT VESSEL AVAILABLETO A COAST GUARD MARINE INSPECTOR FOR THE PURPOSE OF CONDUCTING A IOPP SURVEY AND IN CASE LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 10 November 1988
Resolved 10 November 1988
Documentation
Issued 5 October 1988
Resolved
PRIOR TO EMBARKING ON AN INTERNAL VOYAGE MAKE SUBJECT VESSEL AVAILABLE TO ACOAST GUARD MARINE INSPECTOR FOR THE PURPOSE OF CONDUCTING A IOPP SURVEY AND NO CASE LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 5 October 1988
Resolved 5 October 1988
Construction/Loadline
Issued 12 September 1988
Resolved
MAKE PERMANENT REPAIRS TO AND PROVE PROPER OPERATION OF BOW LUBE OIL PRESSURE SHUTDOWNS ON ALL BALLAST PUMP PRIME MOVERS TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 12 September 1988
Resolved 12 September 1988
Construction/Loadline
Issued 12 September 1988
Resolved
PROVIDE AND INSTALL APPROVED FUEL LINES ON THE AFT PORT BALLAST PUMP PRIME MOVER AND ACHOR WINDLASS PRIME MOVER TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR AND THE COGNIZANT OCMI PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 12 September 1988
Resolved 12 September 1988